This document comprises structural plans and general notes prepared by Midwest Engineering for the City of Sioux Falls Public Works Division of Engineering pertaining to Fire Station No. 1 Alley and Wall Repairs (Bid Request No. 26-1086, CIP #11014). The project encompasses retaining wall repairs, helical tie back installations, and concrete pavement repairs in the alley located between West 9th Street and West 10th Street at the Central Fire Station (100 S Minnesota Ave, Sioux Falls, SD 57104). The scope includes removal and replacement of concrete pavement repair areas totaling approximately 256.6 square yards in four distinct repair types (T, W, Z configurations), installation of helical tie backs at specified depths with minimum 20-foot embedment, placement of reinforced concrete walls with #5 rebar reinforcement, and associated joint sealing and asphalt patching work. The project is governed by the 2021 International Building Code and requires contractor verification of all dimensions prior to construction, with contractors responsible for obtaining a building permit (zero cost), maintaining OSHA compliance, and protecting existing structures from damage during installation.
The project is estimated at $148,000 and will be funded through CIP No. 11014. The plans specify detailed concrete material requirements including 4,000 to 4,500 PSI compressive strength at 28 days, maximum water-to-cement ratios of 0.42 to 0.45, and entrained air content specifications. Helical pier installers are required to provide sealed structural calculations, installation logs, torque calibration reports, and evidence of minimum ten previous tie back installations of similar size prior to work commencement. Special inspection requirements mandate third-party inspection by qualified professionals meeting IBC Section 1704 standards, with the City responsible for employing independent inspectors. Shop drawings for reinforcing steel and helical pier installations require general contractor review and stamping prior to engineer review, with a minimum five working-day review period. For inquiries regarding the bid, contractors should contact Robbie Veurink at 605-481-1649 or John Osman at 605-367-8640.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Bid Form-Specs (2).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NO:
PLOT DATE:
SCALE:
S0
DRAWING TITLE:
GENERAL NOTES
STRUCTURAL
ENGINEER:
PLAN NUMBER:
MIDWEST
ENGINEERING
24x36D
46752 269TH ST
SIOUX FALLS, SD 57106
605-481-1649
WWW.MIDWENG.COM
PROJECT:PROJECT:
OWNER:
CITY OF
SIOUX FALLS
5.5.2026
26-3002
FIRE STATION NO.1
ALLEY AND WALL
REPAIRS
DESIGN CRITERIA
1. GOVERNING BUILDING CODE:
IBC 2021
GENERAL
1. ALL CONSTRUCTION SHALL BE IN
CONFORMANCE WITH THE
GOVERNING BUILDING CODE
AND SUPPLEMENTS UNLESS
HIGHER STANDARD IS REQUIRED
BY LOCAL BUILDING OFFICIAL.
2. THE CONTRACTOR SHALL VERIFY
ALL DIMENSIONS AND
CONDITIONS AT THE SITE.
3. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR SAFETY AND
PROTECTION WITHIN AND
ADJACENT TO THE JOB SITE.
4. THE CONTRACTOR IS
RESPONSIBLE FOR MEETING ALL
APPLICABLE OSHA SAFETY
REQUIREMENTS DURING
CONSTRUCTION.
5. DURING AND AFTER
CONSTRUCTION THE
CONTRACTOR AND/OR OWNER
SHALL KEEP LOADS ON THE
STRUCTURE WITHIN THE LIMITS
OF THE DESIGN LOADS.
CONSTRUCTION MATERIAL
SHALL BE SPREAD OUT IF
PLACED ON FRAMED FLOORS OR
ROOF.
6. IF DIMENSIONS ARE IN
QUESTION, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR
OBTAINING CLARIFICATION
FROM THE ENGINEER BEFORE
CONTINUING WITH
CONSTRUCTION.
7. SHOP DRAWINGS SHALL BE
SUBMITTED TO THE GENERAL
CONTRACTOR PRIOR TO START
OF CONSTRUCTION. THE
GENERAL CONTRACTOR SHALL
SUBMIT ONE (1) COPY OF ALL
SHOP DRAWINGS TO THE
STRUCTURAL ENGINEER FOR
REVIEW PRIOR TO FABRICATION
OR ERECTION. FIVE (5)
WORKING DAYS (MINIMUM)
SHALL BE ALLOWED FOR THE
REVIEW OF THESE SHOP
DRAWINGS BY THE ENGINEER.
8. THE TYPICAL DETAILS SHALL BE
USED WHEREVER APPLICABLE
UNLESS OTHERWISE NOTED ON
THE DRAWINGS. SPECIFIC
NOTES AND DETAILS ON
DRAWINGS SHALL TAKE
PRECEDENCE OVER GENERAL
NOTES AND TYPICAL DETAILS.
9. ALL OMISSIONS OR CONFLICTS
BETWEEN THE VARIOUS
ELEMENTS OF THE WORKING
DRAWINGS AND/OR
SPECIFICATIONS SHALL BE
BROUGHT TO THE ATTENTION
OF THE STRUCTURAL ENGINEER
BEFORE PROCEEDING WITH ANY
WORK INVOLVED. IN CASE OF
CONFLICT, FOLLOW MOST
STRINGENT REQUIREMENT AS
DETERMINED BY STRUCTURAL
ENGINEER WITHOUT COST TO
OWNER.
10.OBSERVATION VISITS TO THE
JOB SITE BY DESIGN
ENGINEERING FIELD
REPRESENTATIVES SHALL
NEITHER BE CONSTRUED AS
INSPECTION NOR APPROVAL OF
CONSTRUCTION.
11.WHERE REFERENCE IS MADE
TO VARIOUS TEST STANDARDS
FOR MATERIALS, SUCH
STANDARDS SHALL BE THE
LATEST EDITION AND/OR
ADDENDUM.
12.ESTABLISH AND VERIFY ALL
OPENINGS AND INSERTS FOR
ARCHITECTURAL, MECHANICAL,
ELECTRICAL AND PLUMBING
WITH APPROPRIATE TRADES,
DRAWINGS AND
SUBCONTRACTORS PRIOR TO
CONSTRUCTION. DO NOT
PENETRATE ANY STRUCTURAL
ELEMENTS (BEAMS, COLUMNS,
WALLS, SLABS, STEEL DECKS,
ECT.) WITHOUT PRIOR WRITTEN
APPROVAL OF STRUCTURAL
ENGINEER.
13.ANY ENGINEERING DESIGN
PROVIDED BY OTHERS AND
SUBMITTED FOR REVIEW SHALL
BEAR THE SEAL OF A CIVIL OR
STRUCTURAL ENGINEER
REGISTERED IN THE STATE IN
WHICH THE PROJECT IS
LOCATED.
14.LARGE-SCALE, MORE SPECIFIC
DETAILS TAKE PRECEDENCE
OVER SMALL-SCALE, LESS
SPECIFIC DETAILS AND
INFORMATION. MORE
STRINGENT REQUIREMENTS FOR
CODE, PRODUCTS AND
INSTALLATION TAKE
PRECEDENCE OVER LESS
STRINGENT REQUIREMENTS.
NOTIFY ENGINEER OF ANY
DISCREPANCY CONDITIONS
REQUIRING INFORMATION OR
CLARIFICATIONS BEFORE
PROCEEDING WITH WORK.
15.DETAILS SHOWN ARE
INTENDED TO BE INDICATIVE OF
THE PROFILES AND TYPES OF
DETAILING REQUIRED
THROUGHOUT THE WORK.
DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO
DETAILS SHOWN. WHERE
SPECIFIC DIMENSIONS, DETAIL
OR DESIGN INTENT CANNOT BE
DETERMINED, NOTIFY THE
ENGINEER BEFORE PROCEEDING
WITH WORK.
16.WRITTEN DIMENSIONS TAKE
PRECEDENCE OVER SCALED
DIMENSIONS. NOTIFY ENGINEER
OF ANY DISCREPANCIES OR
CONDITIONS REQUIRING
INFORMATION OR
CLARIFICATIONS BEFORE
PROCEEDING WITH THE WORK.
17.GENERAL CONTRACT
DOCUMENTS SHALL BE ISSUED
TO ALL SUBCONTRACTORS BY
THE GENERAL CONTRACTOR IN
COMPLETE SETS IN ORDER TO
ACHIEVE FULL EXTENT AND
COMPLETE COORDINATION OF
ALL WORK.
SHOP DRAWINGS
1. THE GENERAL CONTRACTOR
WILL REVIEW AND STAMP ALL
SHOP DRAWINGS AND PRODUCT
DATA FOR CONFORMANCE
WITH THE CONSTRUCTION
DOCUMENTS PRIOR TO
SUBMISSION. ANY SHOP
DRAWINGS OR PRODUCT DATA
NOT REVIEWED AND STAMPED
BY THE GENERAL CONTRACTOR
WILL BE RETURNED WITHOUT
REVIEW.
2. ANY SHOP DRAWING NOT
CHECKED AND INITIALED BY THE
SUPPLIER/DETAILER PRIOR TO
SUBMITTING FOR
ARCHITECTURAL AND
ENGINEERING REVIEW, WILL BE
RETURNED WITHOUT REVIEW.
3. THE CONSTRUCTION
DOCUMENTS MAY NOT BE
REPRODUCED FOR USE AS SHOP
DRAWINGS.
4. ELECTRONIC FILES OF
CONSTRUCTION DOCUMENTS
WILL NOT BE MADE AVAILABLE
FOR USE AS SHOP DRAWINGS.
FIRE STATION NO. 1 ALLEY AND WALL REPAIRS
SIOUX FALLS, SOUTH DAKOTA
BID REQUEST NO. 26-1086
CIP #11014
CITY OF SIOUX FALLS
PUBLIC WORKS - DIVISION OF ENGINEERING
224 WEST 9TH STREET
SIOUX FALLS, SD 57104 (605) 367-8601
APPROVED
CITY ENGINEER DATE
CENTRAL FIRE STATION
100 S MINNESOTA AVE
SIOUX FALLS, SD 57104
AutoCAD SHX Text
ALLEY MAP
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text S0
AutoCAD SHX Text
RobbieVeurink Snapshot
RobbieVeurink Text Box 5-11-2026
SCALE:
S01
DRAWING TITLE:
GENERAL NOTES
STRUCTURAL
ENGINEER:
PLAN NUMBER:
MIDWEST
ENGINEERING
24x36D
46752 269TH ST
SIOUX FALLS, SD 57106
605-481-1649
WWW.MIDWENG.COM
PROJECT:PROJECT:
OWNER:
CITY OF
SIOUX FALLS
5.5.2026
26-3002
FIRE STATION NO.1
ALLEY AND WALL
REPAIRS
APPLICABLE CODES AND STANDARDS:
1. 2021 INTERNATIONAL BUILDING CODE (IBC)
DESIGN LOADS:
1. RETAINING WALL
A. EFP: 50 PSF/FT
CAST-IN-PLACE CONCRETE:
1. CONCRETE SHALL CONFORM TO ALL REQUIREMENTS OF ACI 318-14 "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE", EXCEPT AS MODIFIED BY THE
SUPLEMENTAL REQUIREMENTS BELOW:
A. FOOTINGS, FOUNDATION WALLS, COLUMNS, BEAMS, SUSPENDED SLABS,
BEARING WALLS, PIERS - LOW ALKALI PER ASTM C150, MAX WATER TO
CEMENT RATIO = 0.45.
B.
C.
EXTERIOR SLABS ON GRADE - AIR CONTENT TO BE 6 1/2% +/- 1 1/2% PER
ASTM C20 WITH MAXIMUM SIZE AGREGATE 1 1/2" PER ASTM C33, MAX WATER
TO CEMENT RATIO = 0.45.
INTERIOR SLABS ON GRADE - TYPE 2 LOW ALKALI PER ASTM C150, MAXIMUM
AIR CONTEN 3 1/2% +/- 1 1/2% PER ASTM C20 WITH CAX SIZE AGGREGATE 1
1/2" PER ASTM C33, MAX WATER TO CEMENT RATIO = 0.45 - NO WATER TO BE
ADDED TO CONCRETE ON SITE. SUPERPLASTICIZER MAY BE ADDED TO
INCREASE SLUMP AS REQUIRED FOR PLACEMENT. HIGH RANGE WATER
REDUCING ADMIXTURE AS PER ASTM C494 TYPE G.
D. CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE
STRENGTH AT 28 DAYS:
a.
b.
FOOTING AND FOUNDATION WALLS - 4000 PSI
EXTERIOR SLABS ON GRADE, SUSPENDED SLABS, BEAMS, COLUMNS,
BEARING WALLS - 4500 PSI
c.
E.
2.
3.
INTERIOR SLAB-ON-GRADE - 4000 PSI
A STATEMENT OF MIX DESIGN FOR ALL CONCRETE SHALL BE SUBMITTED
AND APPROVED BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO
COMMENCING WORK.
ALL SLABS ON GRADE SHALL BE PLACED WITH CONSTRUCTION JOINTS OR SAW
CUTS AT 10'-0" ON CENTER MAXIMUM OR AS SHOWN OR NOTED ON THE DRAWINGS.
CONCRETE TESTS SHALL BE MADE ON MAJOR POURS AND AT SUCH OTHER TIMES
AS MAY BE REQUIRED BY THE STRUCTURAL ENGINEER OF RECORD. EACH TEST
SHALL CONSIST OF 3 CYLINDERS OF WHICH (1) SHALL BE TESTED AT (7) DAYS, (2)
SHALL BE TESTED AT (28) DAYS, AND (1) SHALL BE RETAINED IN RESERVE FOR
LATER TESTS, IF REQUIRED.
4. IN GENERAL, ONE TEST SHALL BE MADE FOR EACH 150 CUBIC YARDS OF CONCRETE,
NOR LESS THAN ONCE EACH 5000 SF OF SURFACE AREA FOR SLABS OR WALLS ON
EACH DAY'S POUR. SPECIMENS SHALL BE MADE AND TESTED IN ACCORDANCE WITH
ASTM C-31 AND ASTM C-39 STANDARDS. SLUMP AND AIR ENTRAINMENT TESTS
SHALL ALSO BE MADE WITH EACH SET OF CYLINDERS TAKEN. AIR SHALL BE ADDED
TO ALL CONCRETE EXPOSED TO WEATHER. CONCRETE TESTS SHALL BE PROVIDED
PER ACI-318.
5.
6.
7.
BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO ENSURE PROPER
PLACEMENT OF ALL OPENINGS, SLEEVES, CURBS, CONDUIT, BOLTS, INSERTS,
DOWELS, ETC., RELATED TO THE WORK.
DOWEL VERTICAL BARS TO FOOTINGS. IN ADDITION, PROVIDE (2) #5 CONTINUOUS
BARS AT TOP OF WALLS UNLESS OTHERWISE NOTED ON DRAWINGS.
ADD (2) #5 BARS AROUND ALL OPENINGS (UNO) AND EXTEND 24" BEYOND OPENINGS.
REINFORCING STEEL:
1.
2.
4.
ALL CONCRETE SHALL INCLUDE REINFORCEMENT. IF REINFORCEMENT IS NOT
SPECIFICALLY INDICATED ON THE DRAWING VERIFY WITH THE SER.
REINFORCEMENT SHALL CONFORM TO THE FOLLOWING STANDARDS AND MATERIAL
PROPERTIES:
DEFORMED BARS
WELDABLE DEFORMED BARS
EPOXY COATED DEFORMED BARS
WELDED WIRE FABRIC
EPOXY COATED WELDED WIRE FABRIC
3.
A615 – Grade 60 ASTM A706 – Grade 60
ASTM A615/A775
ASTM A185
ASTM A185/A884
U.O.N. ON STRUCTURAL DRAWINGS, PROVIDE MINIMUM CONCRETE PROTECTION
FOR REINFORCING, AS FOLLOWS:
a.
b.
c.
4.
5.
6.
7.
Cast Against Earth:
Exposed To Earth Or Weather i.
ii.
ii.
Slabs And Walls:
#5 And Smaller Bars And WWF:
#6 And Larger Bars:
Not Exposed To Earth Or Weather i.
Columns, Pedestals, Beams:
3”
1-1/2” 2”
3/4" 1-1/2”
WHERE CONSTRUCTION JOINTS ARE PROVIDED, THE REINFORCING MUST PASS
UNINTERRUPTED THROUGH THE JOINT. PROVIDE ADDITIONAL #4 X 4’-0” AT 12” O.C.
DOWELS CENTERED TO AND PERPENDICULAR TO THE JOINT.
6.
WWF SHALL BE PROVIDED IN SHEETS ONLY AND SHALL HAVE ENDS LAPPED 1.5 FULL
PANEL ON ALL SIDES.
DOWELS SHALL MATCH SIZE AND SPACING OF MAIN REINFORCEMENT, UON.
REINFORCING INDICATED AS CONTINUOUS SHALL BE PROVIDED AT LONGEST
PRACTICAL BAR LENGTHS WITH MINIMUM SPLICES.
PROVIDE LAP LOCATIONS AS FOLLOWS, UON ON THE ON THE DRAWINGS:
Beam and Slab Top Reinforcing: At Center Of Span Beam and Slab Bottom Reinforcing: At Supports Wall and Beam Side Horizontal Reinforcement: Stagger Splices Wall Inside Face (Vertical Reinforcement): At Support Wall Outside Face (Vertical Reinforcement): At Mid-Height Of Wall
ALL REINFORCING SPLICES SHALL BE CLASS B LAP SPLICES U.O.N.
3.
4.
SHOP DRAWINGS:
1.
2.
THE GENERAL CONTRACTOR WILL REVIEW AND STAMP ALL SHOP DRAWINGS AND
PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS PRIOR TO
SUBMITTAL. ANY SHOP DRAWING OR PRODUCT DATA NOT REVIEWED AND STAMPED BY
THE GENERAL CONTRACTOR WILL BE RETURNED WITHOUT REVIEW.
ANY SHOP DRAWING NOT CHECKED AND INITIALED BY THE SUPPLIER/DETAILER PRIOR TO
SUBMITTING FOR ARCHITECTURAL AND ENGINEERING REVIEW, WILL BE RETURNED
WITHOUT REVIEW.
THE CONSTRUCTION DOCUMENTS MAY NOT BE REPRODUCED FOR USE AS SHOP
DRAWINGS.
ELECTRONIC FILES OF CONSTRUCTION DOCUMENTS WILL NOT BE MADE AVAILABLE FOR
USE AS SHOP DRAWINGS UNLESS APPROVED BY THE EOR.
C.
5.
C.
D.
E.
GENERAL:
1.
16.
SPECIAL INSPECTION:
1.
2.
3.
17.
15.
4.
5.
6.
7.
2.
3.
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE GOVERNING BUILDING
CODE AND SUPPLEMENTS UNLESS HIGHER STANDARD IS REQUIRED BY LOCAL
BUILDING OFFICIAL.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND PROTECTION WITHIN
AND ADJACENT TO THE JOB SITE.
THE CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE OSHA SAFETY
REQUIREMNTS DURING CONSTRUCTION.
DURING AND AFTER CONSTRUCTION THE CONTRACTOR AND/OR OWNER SHALL KEEP
LOADS ON THE STRUCTURE WITHIN THE LIMITS OF THE DESIGN LOADS.
CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS
OR ROOFS.
DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ENGINEER
BEFORE CONTINUING WITH CONSTRUCTION.
SHOP DRAWINGS SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR PRIOR TO
FABRICATION OR ERECTION FOR THE FOLLOWING ITEMS:
A.
B.
C.
REINFORCING STEEL
HELICAL PIER DELEGATED SUBMITTAL
THE GENERAL CONTRACTOR SHALL SUBMIT ONE (1) COPIES OF ALL SHOP
DRAWINGS TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO
FABRICATION OR ERECTION. FIVE (5) WORKING DAYS MIMIMUM SHALL BE
ALLOWED FOR THE REVIEW OF THESE SHOP DRAWINGS BY THE ENGINEER.
8.
9.
THE TYPICAL DETAILS SHALL BE USED WHEREVER APPLICABLE UNLESS OTHERWISE
NOTED ON THE DRAWINGS. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL
TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING
DRAWINGS AND/OR SPECIFICATION SHALL BE BROUGHT TO THE ATTENTION OF THE
STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK INVOLVED. IN CASE
OF CONFLICT, FOLLOW MOST STRINGENT REQUIREMENT AS DETERMINED BY
STRUCTURAL ENGINEER WITHOUT COST TO OWNER.
10.
11.
OBSERVATION VISITS TO THE JOBSITE BY ENGINEERING FIELD REPRESENTATIVES
SHALL NEITHER BE CONSTRUED AS INSPECTION NOR APPROVAL OF CONSTRUCTION.
THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION.
THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES.
12. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH
STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM.
13. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL,
MECHANICAL, ELECTRICAL, AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS,
AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. DO NOT PENETRATE ANY
STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC)
WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER THROUGH
ARCHITECT.
14. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW
SHALL BEAR THE SEAL OF A CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE
STATE IN WHICH THE PROJECT IS LOCATED.
ALL EXTERIOR FINISH MATERIALS, DRAINAGE, AND FLASHING DETAILS ARE NOT PART
OF THE STRUCTURAL DRAWINGS. CONTRACT DOCUMENTS ADDRESS STRUCTURAL
DESIGN ONLY.
LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER SMALL-SCALE,
LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT REQUIREMENTS FOR
CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE OVER LESS STRINGENT
REQUIREMNTS. NOTIFY ENGINEER OF ANY DISCREPANCIES, CONDITIONS REQUIRING
INFORMATION, OR CLARIFICATIONS BEFORE PROCEEDING WITH WORK.
DETAILS SHOWN ARE INTEDNED TO BE INDICATIVE OF THE PROFILE AND TYPES OF
DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE SIMILAR
IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS, OR
DESIGN INTENT CANNOT BE DETERMINED, NOTIFY THE ENGINEER BEFORE
PROCEEDING WITH WORK
18. WRITTEN DIMENSIONS SHALL TAKE PRECENDENCE OVER SCALED DIMENSIONS.
NOTIFY ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING
INFORMATION OF CLARIFICATIONS BEFORE PROCEEDING WITH THE WORK.
19. GENERAL CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY
THE GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE FULL
EXTENT AND COMPLETE COORDINATION OF ALL WORK.
SPECIAL INSPECTION AND QUALITY ASSURANCE, AS REQUIRED BY SECTION 1704 OF
THE 2021 IBC, SHALL BE PROVIDED BY AN INDEPENDENT AGENCY EMPLOYED BY
THE OWNER UNLESS WAVED BY THE BUILDING OFFICIAL. THE CONTRACTOR SHALL
COORDINATE AND COOPERATE WITH THE REQUIRED INSPECTIONS.
ALL SPECIAL INSPECTORS SHALL BE UNDER THE SUPERVISION OF A REGISTERED
CIVIL OR STRUCTURAL ENGINEER.
THE QUALIFICATIONS OF ALL SPECIAL INSPECTORS SHALL BE REVIEWED AND
APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
THE MINIMUM QUALIFICATIONS FOR THE SPECIAL INSPECTORS ARE AS FOLLOWS:
A.
B. STRUCTURAL WELDING INSPECTION
a.
b.
CONCRETE INSPECTION - I.C.B.O. OR I.C.C. CERTIFICATION IN REINFORCED
CONCRETE AND PRE STRESSED CONCRETE.
VISUAL TESTING - I.C.B.O. OR I.C.C. CERTIFICATION IN STRUCTURAL
STEEL AND WELDING OR A.W.S. CERTIFIED WELD INSPECTOR (C.W.I.)
NON-DESTRUCTIVE TESTING - A.W.S. C.W.I.
HIGH STRENGTH BOLTING INSPECTION - I.C.B.O. OR I.C.C. CERTIFICATION IN
STRUCTURAL STEEL AND WELDING.
EXPANSION/ADHESIVE ANCHOR INSPECTION - I.C.B.O. OR I.C.C.
CERTIFICATION IN REINFORCED CONCRETE AND MASONRY.
SPECIAL CASES - EXPERIENCE ACCEPTABLE TO THE STRUCTURAL
ENGINEER OF RECORD.
DUTIES OF THE SPECIAL INSPECTOR:
A.
B.
THE SPECIAL INSPECTOR SHALL REVIEW ALL WORK LISTED BELOW FOR
CONFORMANCE WITH THE CONTRACT DOCUMENTS AND THE GOVERNING
BUILDING CODE.
THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE
BUILDING OWNER, BUILDING OFFICIAL, ENGINEER OF RECORD, ARCHITECT,
AND CONTRACTOR. ALL ITEMS NOT IN COMPLIANCE SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN
IF UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL.
ONCE CORRECTIONS HAVE BEEN MADE BY THE CONTRACTOR, THE SPECIAL
INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER
THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE
INSPECTOR'S KNOWLEDGE, IN CONFORMANCE TO THE APPROVED PLANS
AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF
THE GOVERNING BUILDING CODE.
DUTIES AND RESPONSIBILITIES OF THE CONTRACTOR.
A.
B.
NOTIFY THE RESPONSIBLE INSPECTOR THAT WORK IS READY FOR
INSPECTION AT LEAST ONE WORKING DAY (24 HOURS MINIMUM) BEFORE
SUCH INSPECTION IS REQUIRED.
ALL WORK REQUIRING SPECIAL STRUCTURAL INSPECTION SHALL REMAIN
ACCESSIBLE ANDEXPOSED UNTIL IT IS OBSERVED BY THE SPECIAL
STRUCTURAL INSPECTOR.
HELICAL PIERS:
1. ALL HELICAL COMPONENTS TO BE HDG AND MFG TO PROVIDED LOADS AS LISTED IN
THE PLANS.
2. HELICAL PIER INSTALLER TO PROVIDE SIGNED AND SEAL STRUCTURAL CALCULATIONS
AND PLANS TO PROVIDE THE LOADS AS LISTED IN THE PLANS. INSTALLATION PLANS
TO INCLUDE TORQUE OF PROCEDURE OF THE TIE BACKS AFTER INSTALLATION WITH
RECOMMENDATIONS FROM THE DESIGN ENGINEER.
3. HELICAL PIER INSTALLER TO PROVIDE INSTALLATION LOGS AFTER INSTALLATION AND
CALIBRATION REPORTS FOR INSTALLATION EQUIPMENT (TORQUE HUB) BEFORE
INSTALLATION.
4. HELICAL PIER INSTALLER TO PROVIDE A MINIMUM OF (10) PREVIOUS TIE BACK
INSTALLATIONS OF SIMILAR SIZE PRIOR TO START OF WORK. EXPERIENCE IS NOT
ALLOWED TO BE SUBSTITUTED AND MUST BE COMPLETED BY THE CREW COMPLETING
THE WORK.
2. DOT STANDARD SPECIFICATIONS TO GOVERN ALLEY PAVEMENT, BASE
COURSE, STEEL BARS (FOR PAVEMENT), ETC.
NONREINFORCED PCC PAVEMENT REPAIR:
1.
CONCRETE REPAIRS SHALL MATCH THE EXISTING 9" TO 10" PAVEMENT THICKNESS.
PAYMENT SHALL BE AT THE CONTRACT UNIT PRICE PER SQUARE YARD,
REGARDLESS OF VARIATIONS IN THICKNESS.
THE CONTRACTOR SHALL SAW THE EXISTING CONCRETE TO FULL DEPTH, REMOVE
AND DISPOSE OF THE EXISTING CONCRETE OR ASPHALT, SHAPE, AND RECOMPACT
THE REMAINING GRANULAR MATERIAL PRIOR TO REPLACEMENT OF THE CONCRETE.
ANY ADDITIONAL GRAVEL CUSHION REQUIRED TO PREPARE THE AREA SHALL BE
FURNISHED AND PLACED BY THE CONTRACTOR.
2.
3. IN FULL WIDTH OR HALF WIDTH REPAIR AREAS, A WORKING CONTRACTION JOINT
WILL BE RECONSTRUCTED AT ONE END AND A TIED JOINT AT THE OTHER END OF
THE PAVEMENT REPLACEMENT AREA. A BOND BREAKER WILL BE REQUIRED AT
LONGITUDINAL JOINTS.
4. IN PARTIAL WIDTH REPAIR AREAS WHERE THE REPAIR IS ENTIRELY ON EITHER SIDE
OF THE EXISTING CONTRACTION JOINT, THE LOCATION OF THE ONE THE WORKING
JOINTS WILL BE AT THE ORIGINAL LOCATION. ANY EXISTING DOWEL BAR
ASSEMBLIES SHALL BE SAWED OFF OR REMOVED. IN OTHER PARTIAL WIDTH REPAIR
AREAS, A TIED JOINT SHALL BE RECONSTRUCTED AT BOTH ENDS OF EACH
PAVEMENT REPLACEMENT AREA. AT REPAIR AREAS WHERE BOTH ENDS HAVE BEEN
TIED, A SAWED JOINT WILL BE REQUIRED TO REESTABLISH THE WORKING JOINT.
5. THE STEEL BARS SHALL BE INSTALLED IN THESE JOINTS IN ACCORDANCE WITH THE
STEEL BAR INSTALLATION NOTES AND DETAILS IN THESE PLANS.
6. ALL CONCRETE SHALL MEET THE REQUIREMENTS OF SECTION 380 OF THE
STANDARD SPECIFICATIONS, EXCEPT AS MODIFIED BY THE FOLLOWING NOTES:
1. THE COARSE AGGREGATE SHALL BE CRUSHED LEDGE ROCK.
2. THE FINE AGGREGATE MAY REQUIRE SCREENING AS DETERMINED BY THE
ENGINEER.
3. THE CONCRETE FOR THE NONREIFORCED PCC PAVEMENT REPAIR SHALL BE
OF APPROVED JOB MIX. THE DESIGN MIX SHALL MEET A MINIMUM 4000 PSI
COMPRESSIVE STRENGTH IN 28 DAYS.
4. CONCRETE USED IN PORTLAND CEMENT CONCRETE PAVEMENT REPAIR SHALL
HAVE A MINIMUM CEMENTITIOUS MATERIAL CONTENT OF 600 POUNDS PER
CUBIC YARD, WITH A FLY ASH CONTENT OF 20% TO 25%. ANY VARIATIONS
MUST BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO ANY CONCRETE
PLACEMENT. FLY ASH SHALL MEET THE REQUIREMENTS OF SECTION 605 OF
THE SDDOT STANDARD SPECIFICATIONS FOR ROADS AND BRIDGEES. THE
MAXIMUM ALLOWABLE WATER/CEMENT RATIO SHALL BE 0.42. THE SLUMP WILL
BE LIMITED TO 3" MAXIMUM AND THE CONCRETE SHALL CONSTRAIN 5.0% TO
7.5% ENTRAINED AIR.
7. ALL JOINTS (LONGITUDINAL AND TRANSVERSE) THROUGH AND AROUND THE REPAIR
AREAS SHALL BE SAWED AND SEALED IN ACCORDANCE WITH THE DETAILS SHOWN
IN THESE PLANS.
8. COST FOR PERFORMING THE AFOREMENTIONED WORK INCLUDING SAWING,
FURNISHING AND PLACING CONCRETE, SAWING AND SEALING JOINTS, LABOR,
TOOLS, AND EQUIPMENT SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE PER
SQUARE YARD FOR THE "NONREINFORCED PCC PAVEMENT".
9. COST FOR PERFORMING CONCRETE OR ASPHALT REMOVAL SHALL BE INCLUDED IN
THE CONTRACT UNIT PRICE PER SQUARE YARD FOR "REMOVE CONCRETE
PAVEMENT (FULL DEPTH REPAIRS)".
10. ALL REPAIR AREAS IN NEED OF PROTECTION FROM PEDESTRIAN, BICYCLE AND
VEHICLE TRAFFIC SHALL BE PROTECTED WITH SAFETY TAPE OF OTHER MEANS TO
ENSURE THE SAFETY OF THE WORK ZONE.
RobbieVeurink
SCALE:
S1
DRAWING TITLE:
STRUCTURAL
ENGINEER:
PLAN NUMBER:
MIDWEST
ENGINEERING
24x36D
46752 269TH ST
SIOUX FALLS, SD 57106
605-481-1649
WWW.MIDWENG.COM
PROJECT:PROJECT:
S1
OWNER:
CITY OF
SIOUX FALLS
S1
GENERAL NOTES:
1. CONTRACTOR TO VERIFY ALL DIMENSIONS
BEFORE START OF CONSTRUCTION.
2. CONTRACTOR TO PULL A BUILDING PERMIT
BEFORE STARTING WORK, PERMIT WILL BE
ZERO COST.
3. CONTRACTOR RESPONSIBLE FOR SAFE
CONSTRUCTION PRACTICES AND ALL OSHA
REQUIREMENTS TO COMPLETE THIS WORK.
4. SOILS ASSUMED TO BE CAPABLE TO
SUPPORT 1500 PSF, CITY TO HAVE 3RD PARTY
GEOTECHNICAL ENGINEER VERIFY WHEN
SOILS ARE EXPOSED.
5. CONTRACTOR IS RESPONSIBLE FOR ALL
DAMAGE DONE TO WALLS, PARKING LOG,
EXISTING BUILDINGS, ETC FOR HELICAL
INSTALLATION. ANY DAMAGE WILL BE
REPAIRED FOR THE OWNER AT NO COST.
5.5.2026
26-3002
FIRE STATION NO.1
ALLEY AND WALL
REPAIRS
RETAINING WALL
PLAN
S1 55
'-0
S1
7'-0" 7'-0" 7'-0" 7'-0"
TIE BACK
LOCATION PER
4/S1
4" HDG PL,
18"x18"
4" HDG PL,
12"x12"
HELICAL TIE BACK (2-7/8"x0.217" WALL), 20 KIP SERVICE TENSION
AND 40 KIP ULTIMATE, MINIMUM 20' DEPTH (FINAL DEPTH TO BE
DETERMINED BY HELICAL PIER DESIGNER). PROVIDE TIE BACK
ASSEMBLY HDG ATTACH TO PLATES.
CORE DRILL 16" DIAMETER
THROUGH WALL, SPRAY WITH 4
LB/CF GROUND CONTACT FOAM
TO FILL VOID AFTER HELICAL
INSTALLATION.
'-0
1'-
0"
4'-0"
#5 REBAR 12"
OCEW TOP &
BOTTOM
#5 REBAR 12" OC
VERTICALS AND
18" OC
HORIZONTALLY.
4" CHAMFER ON
ALL OUTSIDE
CORNERS.
INFILL WITH 8"
CONCRETE
WALL, DOWELED
INTO NEW
CONCRETE
WALL.
TIE BACK
LOCATION PER
4/S1
TIE BACK INTO GRANITE WALL BEFORE
REMOVAL OF PERPENDICULAR WALL FOR NEW
CONCRETE WALL. CONTRACTOR RESPONSIBLE
FOR ALL NECESSARY TEMPORARY SHORING
TO COMPLETE THIS WALL.
28'-0" 27'-0"
9'- 0"
'-0
'-5
1'-
0"
2" EXPANSION
JOINT
ALLEY
ELEVATION
FIRE STATION
PARKING LOT
ELEVATION.
NEW
ALLEYWAY
CONCRETE
5" ASPHALT CONCRETE FOR
PATCHING - WORK TO BE
COMPLETED BY CITY OF
SIOUX FALLS STREET
DEPARTMENT
10"
SEE SHEETS J1 FOR
PAVING PLAN AND
DETAILS
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
WALL TIE BACKS
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
RETAINING WALL
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
TIE BACKS
AutoCAD SHX Text
SCALE: 3/4"=1'-0"
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
RETAINING WALL CROSS SECTION
AutoCAD SHX Text
SCALE: 3/4"=1'-0"
AutoCAD SHX Text S1
AutoCAD SHX Text
RobbieVeurink
Remove and replace concrete Repair (T) type 40SQYD (20), Place 3\4" plain round epoxy coated bar.
(7), Drilled 3\4" plain round epoxy coated bar.
(26), Drilled No. 5 x 24" epoxy coated deformed tie bar.
Remove and replace concrete Repair (W) type 87SQYD (33), Placed no 6 x 24" epoxy coated deformed tie bars.
(45), Place 3\4" plain round epoxy coated bar.
(15), Drilled 3\4" plain round epoxy coated bar.
Remove and replace concrete Repair (T) type 92.7SQYD (80), Drilled No 6 x 24" epoxy coated deformed tie bars.
(56), Placed No 6 plain round epoxy coated bar.
(5), Drilled No 6 Plain round epoxy coated bar.
Remove and replace concrete Repair (Z) type 36.9SQYD
(109), Drilled no 6 x 24" epoxy coated deformed tie bars.
(32), Placed 3\4" plain round epoxy coated bar.
W 9th S treet
S Minnesota Ave
W 10th S treet
42" grabber cones
SHEET NO.
J1
P U
B L
I C
W O
R K
S
C
IT
Y O
F S
IO
U
X F
A L L S
Concrete repair area
PAVEMENT REPAIRS FIRE
STATION #1
E O
F M
IN
N E S O T A A
V E B
E T W
E E N W
T H S
T
W T H S
T
F
IR
E S
T A T
IO
N
C O N C R E T E P
A V E M E N T R
E P A
IR
S P A V E M E N T L
A Y O U T
RE
VI
SI
O
N S:
CH
EC
KE
D
B Y:
D
RA
W N
B Y:
D
ES
IG
N
ED
B
Y:
D W
D W
D W
AC
AD
F
IL
E:
D
AT
E:
BY
4/ 8/
D
AT
E:
BY
D
AT
E:
(2) , R11-2 48"x30"
(4), TYPE III BARRICADE
ROAD
CLOSED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
40 FT
File details come from the government source that posted it. Updated .