2-26-10-12 Construction Plans.pdf

PDF 3 MB Posted

Attached to
Lifestyle Center Spray Irrigation Project
Solicitation number
US.254150
Issued by
Lehigh County, Pennsylvania

About this file

This construction plans document pertains to the Lifestyle Center Spray Irrigation Project for Upper Macungie Township in Lehigh County, Pennsylvania, designed by Michael K. Hartley, Certified Irrigation Designer. The project encompasses the design and installation of a comprehensive storm water spray irrigation system with associated controls and mechanical components. The system is designed to utilize 76,611 cubic feet from an existing detention basin within seven days of each storm event and includes 10 sprinkler zones with varying precipitation rates ranging from 0.75 to 7.25 inches per hour, a 200 GPM pump operating at 75 PSI, mainline and lateral HDPE piping, electric valves with decoder controls, and a control panel with VFD pressure regulation. The irrigation system covers two primary areas totaling approximately 68,000 square feet (1.56 acres combined). Installation requirements include trenching at 24 inches deep for mainline pipes and 18 inches for lateral pipes, with all trenches to be backfilled and compacted the same day they are excavated. The system is designed to operate from March 15 through November 15, weather dependent, and shall not be activated until 24 hours after significant precipitation events or until receiving areas are well vegetated. The contractor must provide one year of irrigation maintenance post-installation, with annual startup and monthly maintenance procedures detailed in the specifications.

The design specifications require a contractor with minimum five years of documented experience specializing in irrigation system installation and HDPE pipe welding. Key mechanical components include a stainless steel intake screen, automatic drain valves at low points, air release valves at high points, surge protection with grounding systems, and a Davis rain sensor with freeze protection capabilities. All wiring must comply with NEC standards and be installed with minimum 18 inches of cover, with decoder wire splices made only at valve locations using waterproof UL-listed connectors. The system incorporates Toro equipment throughout, including 835B-02 sprinkler heads, electric valves with DC latching solenoids, and a Sentinel decoder cabinet controller. The project is subject to Pennsylvania Prevailing Wage Act requirements and the Public Works Employee Verification Act. Bids are due electronically via the PennBid Program by 9:00 AM on Monday, October 12, 2026, with bid security required at 10 percent of the total bid price in the form of a certified check or bond from a qualified surety.

View the file

Other files

File Type Posted
1-26-10-12 Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W W

W W W

W W

WW

S S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

N

TEST 1

1.75"/HR

TEST 2

7.25"/HR

TEST 3

3.00"/HR

TEST 4

0.75"/HR

TEST 5

3.50"/HR

TEST 6

1.50"/HR

TEST 7

0.75"/HR

TEST 8

1.00"/HR

TEST 9

3.75"/HR

T

E

S

T

C

H

R

T

E

B

H

R

T

E

A

H

R

#1

#2

#3 #4

#5

#6

#7

#8

#9 #10

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

W

P

AREA TOTAL

39,713 sqft

0.912 acres

AREA TOTAL

28,276 sqft

0.649 acres

F

Pump:

200 GPM @

75 PSI Required

Stainless

Steel Intake

Screen

3" Winter

Bypass

S

S

C

G

RSP

TEST 5

3.50"/HR

NORTH

#1

WP1

F

0 50 100 150

SCALE IN FEET

1.5" Toro P220 Scrubber Electric Valve W/Pressure regulation on a HDPE fitting -Line Sized, within a 12" x 18" valve box and with Nibco Bronze Gate Valve Threaded

1. This schematic is intended only as a guide for the installation and does not depict exact placement of the components. Final location of all components shall be determined in the field by the Owner /

Engineer in conjunction with the installer.

2. See the note at each pump location for system parameters. Elevations have been provided on base files by others.

3. This irrigation design is based on uniform water distribution throughout the piping system.

4. Non-irrigation components of this drawing have been provided by others.

5. Pipe crossing at roads shall be ductile iron or approved equal. Wire crossing at roads shall be sleeved with pvc pipe (refer to job specifications).

6. Air release valves shall be installed at the highest points of the irrigation system in locations agreed upon by the owner's representative and project manager.

7. Automatic drain valves shall be installed at the lowest point in piping of each zone in locations agreed upon by the owner's representative and project manager.

8. Should a discrepancy exist between this schematic and the written specification, the written specification will prevail.

9. This design represents an irrigation system which is not inherently protected from freezing weather.

Proper winterization is necessary to prevent damage from freezing, based on local weather conditions.

10. Pipe sizing on this plan has been determined by the following:

- Velocity is not to exceed 5.0 fps Mains & 5.5 fps on Laterals

- Sprinkler use is evenly distributed across the irrigated area.

- All mainline and lateral gate valves assumed open

11. The system should be designed to completely drain when it is off.

12. 76,611 cu ft for Basin shall be utilized within 7 days of the beginning of each storm event.

13. The system shall not be activated until the receiving areas are well vegetated.

14. This system shall not be connected to any domestic water system.

15. System Operation Time: Initialized March 15th and winterized after November 15th, weather dependent.

16. The spray irrigation system shall not be activated until approximately 24 hours after any significant precipitation storm event.

17. The applicant/owner is responsible to monitor and record flow through the spray irrigation system to ensure the required volume is being applied.

AC In line Surge protection #SB-BLA With Specified Grounding

Quick Coupling Valve - Toro 474-00 1"

IRRIGATION MAINTENANCE SCHEDULE

Sprinkler Counts

AC Single Station Decoder #SB-DAC-1

Zone or Station Number

MECHANICAL / GENERAL NOTES

4" 4710 DR 13.5 HDPE Pipe - MAIN

Air Release Valve in a Jumbo Valve Box

#SBDBWS1U - Sentinel Two Wire Decoder Cabinet Satellite

1. Before final grading and topsoil has been installed, trench for all pipe sizes 18”lateral pipes and 24” deep for mainline pipes as specified.

2. Install all pipe, fittings, valves, valve boxes, quick coupler valves, sprinklers and wire in the trench as specified.

3. Back fill all trenches in lifts of 6” and compact the backfill so there is no settling.

4. All trenched shall be trenched and backfilled of the same day. There shall be no trenches open overnight.

5. Locate and mark all irrigation material prior to installing and grading top soil.

6. Install topsoil as specified.

7. Seed or sod as specified.

3" 4710 DR 13.5 HDPE Pipe - MAIN

Pump - (See Details Sheet) Designed at 200 GPM @ 75 PSI

2" 4710 DR 13.5 HDPE Pipe - LATERAL

Toro 835B-02-315 Sprinkler, Full Circle (360) - 50' Spacing @ 50 PSI 10

IRRIGATION CONSTRUCTION SCHEDULE

IRRIGATION LEGEND SENTINEL DECODER WIRING NOTES

Ground Location

Data Industrial Flow meter - 2" (See Pump on Details Sheet)

1. All wiring to be install in accordance with NEC and/or authority having jurisdiction.

2. Contractor shall verify all routings of wire in and around features with owner prior to installation.

3. All wire must be buried with a minimum of 18" of cover.

4. Each Toro decoder cable run from the controller the field, shall have a different colored stripe.

5. Each electric valve shall have a DC latching solenoid installed.

6. Each electric valve shall be controlled by a Toro decoder located inside the valve box.

7. Decoder wire splices shall be made at valves location or in valve boxes only.

8. At all splice locations, provide sufficient slack to allow the splice to be raised a minimum of 24"(in.)

above grade. Neatly bundle slack together with wire ties and secure decoder to side of valve box with box

9. All decoder wire splices shall be made with 3M DBR/Y-6 direct burial water proof UL listed splice kits rated for 600 volts.

10. A Toro DEC-SG-Line surge protector and specified grounding shall be installed within 500' of any decoder location and at 1000' intervals along paths without decoders.

11. Final location of all control equipment shall be determined in the field by the Owner / Engineer.

12. The owner shall supply 120 vac power to the controller location.

13. The contractor shall supply all the necessary conduits from the controller to the field.

Isolation Gate Valve, Line Sized, with 10" round valve box

Toro Wireless Rain and Freeze Sensor and Davis Rain Collector II. Rain Bucket

AC decoder wire #Paige 180116 Blue 2 pair

SECTION – STORM WATER SPRAYFIELD MAINTENANCE PROCEEDURES SUMMARY

Section includes storm water spray field irrigation maintenance recommendations.

GENERAL REQUIREMENTS

The Contractor shall provide irrigation maintenance for one calendar year. After the first year the contractor can provide service contract with the owner or the owner shall continue irrigation maintenance on their own.

ANNUAL START UP

Inspect wet well pump, float switches, intake screen and, or verify operations for current year, repair as required.

Power up controller verify operations repair and as required. Clear out old volume and pre-pair for current year volumes.

Inspect electric valves. Check and verify correct electric connections to controller decoders and Solenoids.

Inspect sprinklers to verify pop up operations rotation, and spray correct spray pattern arcs.

Inspect flow meter and verify correct flow data.

Inspect rain switch check batteries and correct operations.

Inspect and test high pressure blow off valve.

Inspect and verify operation of auto drain valve.

Inspect and clean out valve boxes from soil or critters.

Inspect and check grounding to controller.

Check the pressure of system.

Replace broken valve box lids.

MONTHLY MAINTENANCE

Confirm controller operation and programming.

Inspect electric valves, manual valves quick coupler valves, sprinklers for proper operation.

Clear the vegetation around valve boxes and sprinklers.

Inspect and check screen at pump intake. Vegetation and pond bottom to be no less than 18” inches from the intake screen at all times.

Collect Monthly flow totals.

If the vegetation is not maintained weekly by mowing around sprinklers then once a month sprinklers and valve boxes shall be cleared by mechanical means (ie. weed eater, pruning shears) of vegetation by a minimum distance of 3’-0” in diameter.

Perform an annual irrigation audit to determine efficiency of the system. Select a sample area and rotate location annually.

END OF SEASON WINTERIZATION

Follow Toro manufacturer recommendation for winterization.

Manually drain system as much as possible.

Keep a zone open when the compressor starts up at all times when transitioning from station to station.

Use an air compressor that produces 30-50 psi maximum.125 CFM for a 3” main or less and 250 CFM for 4” or larger.

Installer: Company specializing in performing Work of this section with minimum five years documented experience.

One cycle is enough per zone. Stop when majority of the mist is complete.

Collect total flows for each month

Test Pit Location

Toro 835B-02-315 Sprinkler, Part Circle (180) - 50' Spacing @ 50 PSI 22

S

C

G

RS

P

Mechanical Plan

IRR-1

2021 Turf Equipment & Supply Co., Inc.C

U

PP

ER

M

A

CU

N

GI

E

TO

W N

SH

IP

L

EH

IG

H V

A

LL

EY

P

EN

N

SY

LV

A N

IA

GR

A N

GE

R O A D P

A

RK

E A

ST

D A T E

N O

R E V I S I O N S

J e s s u p

M a r y l a n d

D o r s e y

R u

R a d

I r r i g a t i o n

D e s i g n e d

B y

AN

D

S

UP

PL

Y

CO

M

PA

N

Y

TU

R

F

EQ

UI

PM

EN

T

MIC

HA

E L K H

AR

TL

EY

MMMIIICCC

HHHAAA

EEE

LLL

KKK

HHH

AAAR

RRTTT

LLLEEEYYY

GO

L F

C O U R S

E

GGGOOO

LLL

FFF

CCC

OOO

UUU

RRR

SSS

EEE

CERTIF

IE

D I R R

I G

AT I ON

D E S

IG

N E R

C I

E A

L

AutoCAD SHX Text

GARAGE

AutoCAD SHX Text

SHED

AutoCAD SHX Text

1" IP

AutoCAD SHX Text

CM (TO BE SET)

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

5/8" IP

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

IP. 2'HIGH

AutoCAD SHX Text

GARDEN

AutoCAD SHX Text

WETZEL STREET

AutoCAD SHX Text (T-540)

AutoCAD SHX Text N/F TY B. & DIANE A. MUTH TAX MAP J7NW2, BLOCK 04, LOT 01 DEED BOOK VOL. 1660, PG. 0260

AutoCAD SHX Text N/F DELORES A. WETZEL TAX MAP J7NW2, BLOCK 04, LOT 02 DEED BOOK VOL. 1649, PG. 0270

AutoCAD SHX Text N/F RANDOLPH J. & JUDY D. PARKS TAX MAP J7NW2, BLOCK 04, LOT 04 DEED BOOK VOL. 1291, PG. 0756

AutoCAD SHX Text N/F COMMUNITY FOUNDATION HUMAN DEVELOPMENT INC. TAX MAP J7NW2, BLOCK 04, LOT 06 DEED BOOK VOL. 1493, PG. 0543

AutoCAD SHX Text N/F JOSEPH G. & PATTIE L. OVERTON TAX MAP J7NW2, BLOCK 04, LOT 07 DEED BOOK VOL. 1132, PG. 0426

AutoCAD SHX Text N/F RONALD P. & RUTH E. REHRIG LIVING TRUST TAX MAP J7NW2, BLOCK 04, LOT 08 DEED BOOK VOL. 1697, PG. 0291

AutoCAD SHX Text N/F GEORGE T. JR. & LINDA MALAFARINA TAX MAP J7NW2, BLOCK 04, LOT 09 DEED BOOK VOL. 1452, PG. 0100

AutoCAD SHX Text N/F BRIAN HINDERLITER TAX MAP J7NW2, BLOCK 04, LOT 05 DEED BOOK VOL. 1639, PG. 0763

AutoCAD SHX Text

N/F CARL W. DORSEY TAX MAP J7NW2, BLOCK 04, LOT 03 DEED BOOK VOL. 1092, PG. 0775

AutoCAD SHX Text

DRIVEWAY

AutoCAD SHX Text

UP 59926 S45747

AutoCAD SHX Text

UP 59945 S45740

AutoCAD SHX Text

UP 59968 S46530 BELL SERVICE

AutoCAD SHX Text

UP 59980 S45724 BELL SERVICE

AutoCAD SHX Text

UP BELL SERVICE

AutoCAD SHX Text

UP 59923 S45808

AutoCAD SHX Text

UP 59923 S45808

AutoCAD SHX Text

UP 60013 S45710 BELL SERVICE

AutoCAD SHX Text

UP BELL SERVICE

AutoCAD SHX Text

UP 59980 S45724 BELL SERVICE

AutoCAD SHX Text

UP 59968 S46530 BELL SERVICE

AutoCAD SHX Text

UP 59945 S45740

AutoCAD SHX Text

UP 59926 S45747

AutoCAD SHX Text

DRIVEWAY

AutoCAD SHX Text S

AutoCAD SHX Text

30" RCP

AutoCAD SHX Text

WETZEL STREET

AutoCAD SHX Text

EDWARD STREET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EX. DETENTION POND WITH WATER QUALITY BASIN AS PER NPDES PERMIT

AutoCAD SHX Text

IP. FND

AutoCAD SHX Text

IP. FND

AutoCAD SHX Text

IP. FND

AutoCAD SHX Text

IP. 2'HIGH

AutoCAD SHX Text

5/8" IP

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

1" IPE

AutoCAD SHX Text

SHED

AutoCAD SHX Text

GARAGE

AutoCAD SHX Text

SHED

AutoCAD SHX Text

EDWARD STREET

AutoCAD SHX Text

MOUNTAIN VIEW COURT

AutoCAD SHX Text

BUILDING RESTRICTION LINE

AutoCAD SHX Text

BUILDING RESTRICTION LINE

AutoCAD SHX Text

GRANGE ROAD

AutoCAD SHX Text

STONE DWY. TO BE PAVED

AutoCAD SHX Text

EX. DETENTION POND

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text

N/F UPPER MACUNGIE TOWNSHIP

AutoCAD SHX Text

DRAINAGE AND UTILITY EASEMENT

AutoCAD SHX Text

DRAINAGE AND UTILITY EASEMENT

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

15" TREE

AutoCAD SHX Text

12" TREE

AutoCAD SHX Text

12" TREE

AutoCAD SHX Text

12" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

24" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

18" TREE

AutoCAD SHX Text

21" TREE

AutoCAD SHX Text

(2)-15" TREE

AutoCAD SHX Text

EX. DWELLING

AutoCAD SHX Text

EX. DWELLING

AutoCAD SHX Text S

AutoCAD SHX Text

INV. 439.20

AutoCAD SHX Text

INV. 439.00

AutoCAD SHX Text

15" HDPE

AutoCAD SHX Text

(4) 4" CONDUITS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text x

AutoCAD SHX Text S

AutoCAD SHX Text

2" TREE

AutoCAD SHX Text

2" TREE

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

42"DIA. TREE

AutoCAD SHX Text

15 MPH

AutoCAD SHX Text

PLAYGROUND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SWINGS

AutoCAD SHX Text

ARCH-SWINGS

AutoCAD SHX Text

48" DIA. TREE

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

EXISTING RESTROOM FACILITY F.F. 446.15

AutoCAD SHX Text

EXISTING PAVILION F.F. 445.25

AutoCAD SHX Text

PAVED PATHWAY

AutoCAD SHX Text

CONCRETE SIDEWALK

AutoCAD SHX Text

ARCHITECTURAL BOULDER (TYP.)

AutoCAD SHX Text

EXISTING UNDERDRAIN

AutoCAD SHX Text

BM

AutoCAD SHX Text

GRATE 445.03

AutoCAD SHX Text

EDGE OF CONCRETE

AutoCAD SHX Text

EDGE OF CONCRETE

AutoCAD SHX Text

EDGE OF CONCRETE

AutoCAD SHX Text

EDGE OF CONCRETE

AutoCAD SHX Text

EDGE OF PAVEMENT

AutoCAD SHX Text

1 1/2" PE WATER SERVICE CONNECTION

AutoCAD SHX Text

30 LF

AutoCAD SHX Text

8" PVC

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

35574.9 Sq. Ft.

AutoCAD SHX Text

0.8 Acres

AutoCAD SHX Text

35574.9 Sq. Ft.

AutoCAD SHX Text

0.8 Acres

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

MH 1 RIM 435.25 INV. IN 431.50 INV. OUT 431.25

AutoCAD SHX Text

AutoCAD SHX Text 446.00

AutoCAD SHX Text 446.00

AutoCAD SHX Text 446.00

AutoCAD SHX Text 446.30

AutoCAD SHX Text 446.30

AutoCAD SHX Text D

AutoCAD SHX Text U11-U12

AutoCAD SHX Text

EXISTING PAVED PARKING LOT

AutoCAD SHX Text 446.00

AutoCAD SHX Text 446.30

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING STONE AREA

AutoCAD SHX Text

(EXISTING STONE AREA)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

COURTS

AutoCAD SHX Text

PROPOSED PICKLEBALL

AutoCAD SHX Text 64.00'

AutoCAD SHX Text 20.00'

AutoCAD SHX Text 30.00'

AutoCAD SHX Text 26.00'

AutoCAD SHX Text 64.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=15.00'

AutoCAD SHX Text R=10.00'

AutoCAD SHX Text R=10.00'

AutoCAD SHX Text R=10.00'

AutoCAD SHX Text R=10.00'

AutoCAD SHX Text 64.00'

AutoCAD SHX Text 64.00'

AutoCAD SHX Text

PROPOSED UNDERGROUND- SINGLE PHASE ELECTRIC SERVICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CO

AutoCAD SHX Text

PROP. GAS SERVICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TEST 1 1.75"/HR

AutoCAD SHX Text

TEST 2 7.25"/HR

AutoCAD SHX Text

TEST 3 3.00"/HR

AutoCAD SHX Text

TEST 4 0.75"/HR

AutoCAD SHX Text

TEST 5 3.50"/HR

AutoCAD SHX Text

TEST 6 1.50"/HR

AutoCAD SHX Text

TEST 7 0.75"/HR

AutoCAD SHX Text

TEST 8 1.00"/HR

AutoCAD SHX Text

TEST 9 3.75"/HR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TEST 2020-A 2.0"/HR

AutoCAD SHX Text

TEST 2020-B 3.0"/HR

AutoCAD SHX Text

TEST 2020-C 5.0"/HR

AutoCAD SHX Text

TEST 2020-D 5.5"/HR

AutoCAD SHX Text

TEST 2020-E 3.0"/HR

AutoCAD SHX Text

SHEET 1 OF 2

AutoCAD SHX Text

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text 01/25/21

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

CTS

AutoCAD SHX Text

GJS

AutoCAD SHX Text 1" = 50'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DESIGN BY

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

AutoCAD SHX Text

EML #

AutoCAD SHX Text

AutoCAD SHX Text

REVISED SCHEDULE

AutoCAD SHX Text 02/15/19

AutoCAD SHX Text

AutoCAD SHX Text

REVISED TEST PITS

AutoCAD SHX Text 04/15/19

AutoCAD SHX Text

AutoCAD SHX Text

ADDED ZONES 8,9,10

AutoCAD SHX Text 01/25/21

12" RECTANGULAR VALVE BOX

DECODER

3M DBY/R-6

WIRE CONNECTORS

DECODER

SERVICE

EXPANSION COIL

1.5" ELECTRIC VALVE WITH 1 STATION DECODER

N.T.S.

HDPE mainline - Isolation valve

N.T.S.

CABLE

HDPE ELECTROFUSION OR

MOLDED 90° ELL

HDPE MOLDED TEE OR

BRANCH SADDLE

TRENCH SHALL BE EXCAVATED TO A DEPTH SUFFICIENT TO INCLUDE THE PIPE

FREE OF STONES AND OTHER DEBRIS THAT COULD DAMAGE COMPONENTS OF

SUFFICIENT FOR PIPE AND OTHER MATERIALS TO BE INSTALLED.

LOCATE POWER WIRE AND SIGNAL WIRES NEXT TO PIPE.

NOTES:

AND 24" OF BACKFILL FOR MAINLINE, 18" OF BACKFILL FOR LATERALS.

THE IRRIGATION SYSTEM.

DEPTH-

WIDTH -

BACKILL-

INSTALLATION -

24" 18"

M A

I N

L I N

E

L A

T E

R A

L S

ROCKY/SHALE SOIL

DECODER CABLE(S)

CLEAN SOIL

PIPE

BACKFILL

4" MIN

CLEAN BACKFILL

PIPE

4"

MIN

LESS THAN 1/2" SETTLEMENT REQUIRED

CLEAN

4"

MIN

BACKFILL

CLEAN

3" DETECTABLE TAPE

PAIGE PN: 270328D

DETECTABLE TAPE TO BE INSTALLED HALFWAY BETWEEN PIPE AND FINISHED GRADE.

DETECTABLE TAPE -

INSTALLED OVER ALL MAINLINE PIPE 3" & GREATER.

TRENCH CROSS SECTION

N.T.S.

LATERAL PIPE

UNITIZED SWING JOINT

SAME SIZE AS INLET

MANUFACTURED

TORO 835B-02-3X5 SPRINKLER

N.T.S.

INSTALL 1/4" TO 1/2"

BELOW FINISHED GRADE

TORO 835B-02-365 SPRINKLER

BOLT ON SADDLE LASCO

UNITIZED SWING JOINT

SAME SIZE AS INLET

MANUFACTURED

QCV

1" PVC PIPE

MAINLINE PIPE

STABILIZER ELL

BRASS INSERT

SNAP-LOK RING

24" MINIMUM LENGTH

1/2"- 3/8" REBAR

6" ROUND VALVE BOX

QUICK COUPLER VALVE

N.T.S.

BOLT ON SADDLE LASCO

CONTRACTOR MUST HAVE PREVIOUS EXPERIENCE WITH HDPE WELDING

REFER TO SPECIFICATIONS FOR PIPE SIZE AND WELD STYLES.

NOTES:

ELECTROFUSION WELD

SOCKET FUSION WELD

BUTT FUSION WELD

HDPE PIPE

BUTT FUSION

HDPE PIPE

HDPE PIPE

SOCKET FUSION

ELECTROFUSION

HATCH MARKS INDICATE

"SCRAPING" OF PIPE SURFACE

HDPE FUSION TYPES

N.T.S.

8'

SPHERE OF

INFLUENCE

INSULATED - GREEN

#6 SOLID COPPER WIRE

WITH YELLOW STRIPE

INSULATED - GREEN

#6 SOLID COPPER WIRE

GROUND ROD

(5/8" X 8')

NOTES:

1. NO OTHER WIRES OR CABLE SHALL BE

INSTALLED WITHIN THE SPHERE OF

INFLUENCE

2. DO NOT CREATE ANY SHARP BENDS IN

THE #6 WIRES. IF IT IS NECESSARY TO

BEND THE WIRE, DO SO IN A LONG

SWEEPING LINE

COPPER GROUND PLATE

(4" X 8')

C

GROUNDING PROTECTION - TOPVIEW

N.T.S.

NORDSTROM FULL

PORT HDPE BALL

VALVE

BUTT FUSION JOINTBUTT FUSION JOINT

HDPE MAIN LINE

6" HDPE, PVC, OR DRAINAGE

PIPE EXTENSION CENTERED

ON VALVE AND IN VALVE

BOX CUT WITH "MOUSE"

HOLES TO EXTEND TO PIPE

10" ROUND VALVE BOX

4" MIN

LASCO TRANSITION UNION

2" x 1½" MIPT P896-251

IRRITROL 700 SERIES

BRASS GATE

VALVE

DC LATCHING

SOLENOID

LASCO TRANSITION UNION

2" x 1½" MIPT P896-251

1½" ELECTRIC VALVE

S

S

S

DEC-SG-LINE

GREEN

GREEN W/ BLACK

STRIPE

RED

RED W/ BLACK

STRIPE

WHT

BLK

1,000 FEET

MAXIMUM

WHT

BLK

DEC-SG-LINE

500 FEET

MAXIMUM

CDEC-ISP-1

DECODER

MODULE

RED

RED W/ BLACK

STRIPE

3 FEET ±10%

COPPER PLATE /

8 FEET ±10%

COPPER ROD

P

D

D

D E

C O

D E

R

C A

B L

E

P

D

D

D E

C O

D E

R

C A

B L

E

P

D

D

D E

C O

D E

R

C A

B L

E

* (PD7350D) 14/2 JACKETED DECODER CABLE

SEE 1, 2, OR 4 STATION DECODER MODULE

DETAILS

RED

BLACK

RED

BLACK

RED

BLACK

S

RED

RED W/ BLACK

STRIPE

RED

BLACK

DECODER SURGE PROTECTION DIAGRAM

N.T.S.

CDEC-ISP-1

DECODER

MODULE

CDEC-ISP-2

DECODER

MODULE

OPTION A

DRAWING SYMBOL: DRAWING SYMBOL: DRAWING SYMBOL:

DRAWING SYMBOL: DRAWING SYMBOL:

DRAWING SYMBOL:

SENTINEL DECODER FIELD CONTROLLER

N.T.S.

DRAWING SYMBOL:

PUMP

200 GPM @ 75 PSI

High brush

5'

SPRINKLER CLEARING

N.T.S.

3'

Ground cover to remain undisturbed

Upper canopy to trees remain

S p r a y

S p r a y

Clear high brush

Clear ground cover

Clear high brush

MAINTAIN VEGETATION TO ACHIEVE THE SPRAY

IRRIGATION RADIUS SHOWN ON THE PLAN.

10 OHMS RES.

5/8" X 8' COPPER CLAD

GROUND ROD TO ACHIEVE

SOIL AS BACKFILL

1' ABOVE COPPER PLATE

4" PERFORATED PVC PIPE

FINISH GRADE

DEEP WITH GOOD

30" TO 36"

PENTEK 6" ROUND VALVE BOX

#6 SOLID COPPER

WITH 6" SLEEVE

NDS 4" GREEN GRATE

INSULATED WIRES

4" X 8' GROUNDING PLATE

ONE BAG OF POWER FILL GROUND

ENHANCEMENT MATERIAL SHALL BE PLACED

ABOVE, AND ONE BELOW THE GROUNDING

PLATE.

NOTE: MAKE SURE THAT THE MATERIAL

COMPLETELY COVERS THE WELD JOINT AND ANY

BARE COPPER BETWEEN THE WELD JOINT AND

THE GREEN/YELLOW INSULATION.

ROD - GREEN

PLATE - GREEN WITH

YELLOW STRIPE

8'

11'

10'

8' MIN.

6" CONCRETE FOOTING

DECODER CABLE

1 1/2" CONDUIT

1 1/2" SWEEP FOR POWER WIRE

1 1/2" CONDUIT FOR

OPTIONAL SENSORS

1 1/2" SWEEP FOR GROUND WIRES

HAMMOND CABINET

PN:HN4FM604812SS

RAIN SWITCH

SB12WS1U - SENTINEL

WALL MOUNT CABINET

SATELLITE

DAVIS RAIN BUCKET

INCOMING DISCONNECT

PUMP VFD DRIVE PANEL

HAMMOND CABINET

PN:HN4FM604812SS

3 X 3" CONDUITS

VENTED CABINET

6" CONCRETE PAD

INCOMING DISCONNECT

CELLULAR MODEM

TRANSFORMER

STATION COMPONENTS:

A PUMP AND MOTOR

B CHECK VALVE

C PRESSURE TRANSDUCER WITH GAUGE

D HDPE FLOW INDUCER SLEEVE

E FLOW SENSOR

F FLOAT & LEVEL TRANSDUCER

G DEAD-FRONT STATION CONTROL BOX

H SELF-CLEANING INLET STRAINER

I QUICK COUPLER VALVE

J PUMP ISOLATION VALVE

K MOUNTING CHANNEL

L REMOTE DISCONNECT SWITCH

M STAINLESS STEEL ISOLATION VALVE

12"

MIN SUBMERGENCE &

LOW LEVEL SHUT DOWN

G

4" PIPE TO SYSTEM

FIELD WIRE SCHEDULE:

PRESSURE TRANSDUCER: 8AWG (2) COND. SHIELDED

LEVEL FLOAT: 14 AWG (2) COND.

MOTOR WIRE: 10 AWG (3) COND. PLUS GROUND

FLOW SENSOR: 14AWG (2) COND. SHIELDED

DO NOT RUN MOTOR WIRE IN SAME CONDUIT AS FLOAT

SENSOR WIRE, PRESSURE TRANSDUCER WIRE OR MAG

METER CABLE..

PUMP ON LEVEL

CONTROL PANEL TO INCLUDE:

-MULTI-LINE LCD OPERATOR INTERFACE

-FLOW SENSOR DISPLAY AND TOTALIZER

-PSI DISPLAY AND SET POINT

-PUMP RUNNING STATUS & RUN-TIME HRS

-USER ABILITY TO ADJUST ALL SYSTEM PARAMETERS

-VFD PRESSURE REGULATION FOR ENERGY EFFICIENCY

-BRANCH CIRCUIT PROTECTION

-U.L. 508 LISTED ELECTRICAL PANEL ASSEMBLY

-FUSABLE MAIN DISCONNECT

-TORO SB12WS1U CONTROLLER

A

D

L

K

B

F

J

ELEV. 427.0

ELEV. 439.0

ELEV. 433.0

VALVE BOX

GATE VALVES

IN VALVE

BOXES

SCREEN

48"

24"

36"

3" WINTER BYPASS

8" HDPE INTAKE PIPE

ELEV. 433.0

DESCRIPTION OF OPERATION:

WHEN HOA SWITCH IS IN AUTO THE PUMP WILL START WHEN

WATER LEVEL REACHES THE USER SETABLE PUMP START

LEVEL. THE PUMP WILL RETIRE WHEN THE WATER LEVEL

REACHES THE LOW LEVEL SHUT DOWN.

LOW LEVEL ALARM WILL AUTOMATICALLY RESET FOR PUMP

TO START.

PUMP SYSTEM WILL TOTALIZE ALL WATER PUMPED.

SYSTEM SHALL HAVE THE FOLLOWING ALARMS AT MINIMUM

-HIGH DISCHARGE PRESSURE

-LOW DISCHARGE PRESSURE

-VFD FAULT

-LOW LEVEL SHUT DOWN (SOFT FAULT)

-LOSS OF PHASE OR PHASE REVERSAL

-HIGH VOLTAGE

-LOW VOLTAGE

SUMP AREA W/ STONE BASE

ELEV. 433.0

HUGGER

BAND

STAINLESS STEEL SCREEN

WRAPPED AROUND HDPE PIPE

WITH 54 ea. 2" HOLES DRILLED

ON THE BOTTOM HALF OF PIPE

& END SCREEN

ATTACHED

WITH 3 EACH

SS U BOLTS

24" DIA. ADS

DRAIN TEE

SS U BOLT

STAINLESS STEEL SCREEN

WRAPPED AROUND HDPE

PIPE WITH 54 ea. 2" HOLES DRILLED

ON THE BOTTOM HALF OF PIPE &

END SCREEN

INTAKE

HDPE DR

13.5

24" DIA. ADS

DRAIN TEE

ELEV. 430.0

STAINLESS STEEL WETWELL

ISOLATION VALVE & FLOATING

INTAKE PIPE DISCONNECT WITH

STAINLESS STEEL BOLTS

TOP VIEW

ENDWALL

CONCRETE

BASE

STAINLESS STEEL

WETWELL ISOLATION

VALVE & FLOATING INTAKE

PIPE DISCONNECT WITH

STAINLESS STEEL BOLTS

M

M

MINIMUM 25'

VENT

VENT

DAVIS RAIN BUCKET

RAIN SWITCH

20" x 20" x 2' FIBERGLASS BOX

FOR IRRIGATION CONTROLS

54" x 40" x 21" METAL CABINET

LOCKABLE LID - W1S3030

TOP VIEW

HALLIDAY

ACCESS

HATCH -

W1S3030

30"

30"

MANHOLE

STEPS

PRESSURE

BLOW OFF

VALVE

C E

I

S

S

S

C

G

G

G

G

P

Details

IRR-2

C

D A T E

N O

R E V I S I O N S

J e s s u p

M a r y l a d r s e y

R u

R a d

I r r i g a t i o n

D e s i g n e d

B y

AN

D

S

UP

PL

Y

CO

M

PA

N

Y

TU

R

F

EQ

UI

PM

EN

T

MIC

HA

E L K H

AR

TL

EY

MMMIIICCC

HHHAAA

EEE

LLL

KKK

HHH

AAAR

RRTTT

LLLEEEYYY

GO

L F

C O U R S

E

GGGOOO

LLL

FFF

CCC

OOO

UUU

RRR

SSS

EEE

CERTIF

IE

D I R R

I G

AT I ON

D E S

IG

N E R

C I

E A

L

2021 Turf Equipment & Supply Co., Inc.

U

PP

ER

M

A

CU

N

GI

E

TO

W N

SH

IP

L

EH

IG

H V

A

LL

EY

P

EN

N

SY

LV

A N

IA

GR

A N

GE

R O A D P

A

RK

E A

ST

AutoCAD SHX Text

SHEET 2 OF 2

AutoCAD SHX Text

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

CTS

AutoCAD SHX Text

GJS

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DESIGN BY

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

AutoCAD SHX Text

EML #

AutoCAD SHX Text 01/25/21

AutoCAD SHX Text

AutoCAD SHX Text

REVISED SCHEDULE

AutoCAD SHX Text 02/15/19

AutoCAD SHX Text

AutoCAD SHX Text

REVISED TEST PITS

AutoCAD SHX Text 04/15/19

AutoCAD SHX Text

AutoCAD SHX Text

ADDED ZONES 8,9,10

AutoCAD SHX Text 01/25/21

Grange Road Park - East_b04-S1-MECH
Grange Road Park - East_b04-S2-DETAILS

File details come from the government source that posted it. Updated .