2-2026-07-07 26-0014 RACC Warehouse Issued for Bid.pdf
PDF 2 MB Posted
- Attached to
- FY-26-27-03 STEM Equipment
- Solicitation number
- Not on record
- Issued by
- Berks County, Reese CDP, Pennsylvania
About this file
This is a construction document set for warehouse renovation work at Reading Area Community College (RACC) located at 111 Spruce Street, Reading, Pennsylvania 19607. The project, identified as Commission No. 26-0014, involves comprehensive renovations to create a theatrical storage room within the existing warehouse space, including selective demolition, new metal framing, insulation, doors and hardware, structural steel modifications for High-Volume, Low-Speed (HVLS) ceiling fans, storage shelving, a walk-in cooler and freezer, resilient wall base, and associated electrical work including lighting, power, controls, data infrastructure, and installation of two HVLS ceiling fans. The project is structured as a multi-prime contract with two prime contractors designated for General Trades and Electrical work. An optional pre-bid conference is scheduled for Monday, July 13, 2026, from 10:00 to 11:00 AM at the project site to review requirements and permit inspection of existing conditions. Requests for Information and Substitution requests must be submitted no later than 5:00 PM on Wednesday, July 22, 2026, with responses issued via Addendum no later than 3:00 PM on Friday, July 24, 2026. The existing building is approximately 18,957 square feet on the first floor and is classified as a one-story warehouse building with mezzanine and sprinkler system under IBC 2021 Type IIB construction.
The project documents were prepared by Muhlenberg Greene Architects, Ltd., with Project Manager Brad Blankenbiller and Architect Scott Graham (AIA, LEED AP+). All work must comply with the 2021 International Building Code, ICC A117.1 (2017 Edition), local City of Reading ordinances, and OSHA standards. Bidders must demonstrate successful track record in similar work and submit a Contractor's Qualifications Statement (AIA Document A305) and Qualified Contractor Certification Form with their bid proposals. The General Contractor is designated as the lead prime contractor responsible for coordinating all construction activities, maintaining site security, managing waste disposal, performing final cleaning, and ensuring compliance with all applicable codes and regulations. All refuse must be properly disposed of off-site, and contractors are responsible for repairing any damage caused by their demolition and construction activities. The project emphasizes protection of existing finishes, dust control during construction, and coordination among multiple prime contractors and the owner's staff.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ID DESCRIPTION DATE
B00 ISSUED FOR BID/PERMIT 6/30/2026
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
GENERAL
INFORMATION
A-001
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
ABBREVIATIONS
PROJECT DRAWING LIST
GENERAL & CODE INFO
ARCHITECTURAL DEMOLITION & ABATEMENT PLANS
PLANS
ENLARGED PLANS
DETAILS
A-001
A-002
AD-101
A-101
A-401
A-501
GENERAL INFORMATION
CODE SUMMARY AND LIFE SAFETY PLAN
DEMOLITION PLAN
FLOOR PLANS
INTERIOR ELEVATIONS
DETAILS
OFFICE
1.
A-401
B2
C3
D4
A1
6" TYPICAL, UNLESS
OTHERWISE NOTED
1.01.01
1.01.01
101.1
GRAPHIC SYMBOLS
INTERIOR ELEVATION MARKER
INDICATES ELEVATION
LOCATION ON SHEET
INDICATES SHEET
ON WHICH DRAWING
IS SHOWN
ELEVATION / SECTION MARKER
INDICATES ELEVATION
LOCATION ON SHEET
INDICATES SHEET
ON WHICH ELEVATION
IS SHOWN
XX
XX
YY
DETAIL / ENL. PLAN MARKER
ROOM DESIGNATION
WINDOW MARKER
DOOR IDENTIFIERS
ROOM NAME
ROOM NUMBER
WALL TYPE MARKER 4B
SKYLIGHT MARKER
DOOR IDENTIFIER
(ELEVATIONS/SECTIONS)
ENLARGED PLAN
REFERENCE
KEYNOTE IDENTIFIERS
XX
YY
DOOR
IDENTIFIER
(PLANS)
KEYNOTE;
SEE KEYNOTE LEGEND
ON DRAWING'S LAYOUT
ALTERNATE KEYNOTE;
SEE KEYNOTE LEGEND
ON DRAWING'S LAYOUT
(SEE PARTITION LEGEND)
REVISION No.
DRAWING REVISION MARKER
CLOUD DENOTES
CURRENT REVISION ISSUE
PAST REVISION MARKER
(REFERENCE ONLY)
INDICATES DETAIL
LOCATION ON
SHEET
INDICATES SHEET
ON WHICH DETAIL
IS SHOWN
Untitled map
Untitled layer
Untitled layer
Untitled layer
C-CAN (OPTIONAL)
CONSTRUCTION
WASTE DUMPSTER
CHESTNUT STREET
S 2N
D
ST
RE
ET
SPRUCE STREET
LOT 'H'
CONSTRUCTION
ENTRANCE
DOOR #3
WORK AREA
RACC
WAREHOUSE
1 SITE PLAN
BERKS COUNTY
CITY OF READING
PROJECT
LOCATION
111 SPRUCE STREET READING, PA 19607
WAREHOUSE RENOVATIONS
A.D. AREA DRAIN
ABV. ABOVE
ADA ACCESSIBLE / AMERICANS
WITH DISABILITIES ACT
ADJ. ADJUSTABLE
A.o.R. AREA OF REFUGE
ALUM. ALUMINUM
ALT. ALTERNATE
A.F.F. ABOVE FINISHED FLOOR
AC. ACOUSTIC / ACOUSTICAL
A.F. ALUMINUM FACE
APPX. APPROXIMATE /
APPROXIMATELY
ASBO AS SELECTED BY OWNER
BD. BOARD
BLK. BLOCK / BLOCKING
BLDG. BUILDING
B.O. BOTTOM OF
B.O.S. BOTTOM OF STEEL
CAB. CABINET
C.C. CENTER-TO-CENTER
CLG. CEILING
CLOS. CLOSET
C.M. CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
C.J. CONTROL JOINT
CONC. CONCRETE
CORR. CORRIDOR
COL. COLUMN
CONT. CONTINUE / CONTINUOUS
CONTR. CONTRACTOR
DIA. DIAMETER
DTL. DETAIL
DN DOWN
DWG. DRAWING
DEPT. DEPARTMENT
DBL. DOUBLE
DIM. DIMENSION
DR. DOOR
EXIST. EXISTING
EQ. EQUAL
E.C. ELECTRICAL CONTRACTOR
EL. ELEVATION
ELEV. ELEVATOR
ELEC. ELECTRIC / ELECTRICAL
EXP. EXPANSION
EXT. EXTERIOR
EA. EACH
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
FIN. FINISH / FINISHED
FLR. FLOOR
F.O. FACE OF
F.P./FP FILLER PANEL
FT. FEET / FOOT
FLUOR. FLUORESCENT
GYP. GYPSUM
GALV. GALVANIZED
GA. GAUGE
G.C. GENERAL CONTRACTOR
HR. HOUR
H.P. HIGH POINT
HVAC HEAT, VENTILATION, AIR-
CONDITIONING
HORIZ. HORIZONTAL
HT. HEIGHT
INSUL. INSULATION / INSULATING
I.D. INSIDE DIAMETER
INCAND. INCANDESCENT
JAN. JANITOR
JT. JOINT
LBS. POUNDS
LAV. LAVATORY
LAM. LAMINATE
L.P. LOW POINT
MAX. MAXIMUM
MFR. MANUFACTURER /
MANUFACTURED
MTL. METAL
MIN. MINIMUM
MIRR. MIRRORED
MTD. MOUNTED
M.O. MASONRY OPENING
MISC. MISCELLANEOUS
MECH. MECHANICAL
N.I.C. NOT IN CONTRACT
NO. NUMBER
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OPP. OPPOSITE
OPG. OPENING
P.C. PLUMBING CONTRACTOR
P.F. PANEL FACE
PR. PAIR
P.T. PRESSURE TREATED
PL. LAM PLASTIC LAMINATE
QTY. QUANTITY
R RISER
R.W.C. RAIN WATER CONDUCTOR
REINF. REINFORCING / REINFORCED
REQ. REQUIRED
R.O. ROUGH OPENING
REV. REVISED / REVISION
REFL. REFLECTED
REC. RECESSED
RAD. RADIUS
S.S. STAINLESS STEEL
ST. STREET
SIM. SIMILAR
STL. STEEL
SQ. SQUARE
SAN. SANITARY
SUSP. SUSPENDED
STD. STANDARD
SPEC. SPECIFICATION
TEL. TELEPHONE
T.O. TOP OF
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TOIL. TOILET
TYP. TYPICAL
THK. THICK
TMP. TEMPERED
T.S.G. TEMPERED SAFETY
GLASS
U.N.O. UNLESS NOTED
OTHERWISE
U.L. UNDERWRITERS
LABORATORIES
VEST. VESTIBULE
V.C.T. VINYL COMPOSITION
TILE
W/ WITH
W.C. WATER CLOSET
WD WOOD
& AND
@ AT
± PLUS OR MINUS
° DEGREE
∠ ANGLE
[ CHANNEL
# NUMBER
□ SQUARE
Ø ROUND / DIAMETER
℄ / C.L. CENTER LINE
⅊ / PL. PLATE
∏ U-BAR
∟ LEG-BAR
OWNER
READING AREA COMMUNITY COLLEGE
10 SOUTH SECOND STREET READING PA 19602
CONTACT: DOLORES PETERSON, SENIOR VP
PHONE: 610.607.6265
EMAIL: DPETERSON@RACC.EDU
ARCHITECT
MUHLENBERG GREENE ARCHITECTS LTD.
1268 PENN AVENUE WYOMISSING PA 19610
PHONE: 610.376.4927
CONTACT: SCOTT GRAHAM AIA, LEED AP+
EMAIL: SCOTTG@MG-ARCHITECTS.COM
PROJECT DIRECTORY
REGIONAL MAP COUNTY MAP SITE LOCATION
SITE PLAN NOTES
1. GC TO PROVIDE PROTECTION AT ALL CURBS AND
EXISTING PAVING TO REMAIN IN CONSTRUCTION
CIRCULATION ZONES AND ACCESS ROUTES.
2. CONTRACTOR SHALL COORDINATE FINAL SITE
LOGISTICS WITH INPUT FROM OTHER PRIMES AND
OWNER.
GENERAL NOTES
1. EACH PRIME CONTRACTOR AND ITS SUBCONTRACTORS SHALL
VERIFY EXISTING CONDITIONS AND ALL DIMENSIONS BEFORE
PROCEEDING WITH THE WORK OR PURCHASING ANY MATERIALS.
VERIFY LAYOUT IN RELATION TO PROPERTY LINES, BENCH MARKS,
OR OTHER FIXED CONDITIONS AND REPORT DISCREPANCIES TO
ARCHITECT IMMEDIATELY UPON DISCOVERY.
2. ALL CONTRACTOR(S) SHALL COMPARE AND COORDINATE THE
DRAWINGS AND SPECIFICATIONS WITH THEIR OWN WORK AND
ADJACENT WORK. EACH IS REQUIRED TO NOTIFY ARCHITECT OF
DISCREPANCIES OR INCOMPLETE INFORMATION WITHIN THE
CONTRACT DOCUMENTS OR DESIGN INTENT IMMEDIATELY UPON
DISCOVERY. EACH CONTRACTOR SHALL OBTAIN CLARIFICATION
PRIOR TO PROCEEDING WITH THE WORK OR RELATED WORK.
3. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
MAINTAINING THE WORK SITE IN A CLEAN AND ORDERLY
MANNER AND ALLOW FOR SAFE USE OF PREMISES BY THE OWNER,
OCCUPANTS AND VISITORS. EACH PRIME AND/OR SUBCONTRACTOR
SHALL BE RESPONSIBLE TO MAINTAIN CLEANLINESS AND PROTECTION
OF ITS OWN WORK AREAS, WORKMANSHIP, AND PROTECTION OF
ADJACENT WORK.
4. EACH PRIME CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES,
PROCEDURES, SITE SAFETY, EROSION AND SEDIMENTATION CONTROL,
AND COORDINATING WITH THE WORK OF OTHER TRADES.
5. GENERAL CONTRACTOR IS THE DESIGNATED LEAD PRIME CONTRACTOR
AND SHALL COORDINATE CONSTRUCTION ACTIVITIES AND EXTENTS OF
WORK WITH OTHER PRIME CONTRACTORS, OWNER'S STAFF AND
VENDORS WHEN REQUIRED FOR FULL EXECUTION OF THE WORK.
HE SHALL COORDINATE WORK AREAS, LOGISTICS AND SCHEDULES
WITH THE OWNER AND ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
6. ALL REFUSE SHALL BE PROPERLY DISPOSED OF OFF-SITE IN A LEGAL MANNER.
SEE THE PROJECT SPECIFICATIONS FOR WASTE DISPOSAL ASSIGNMENTS
AND RESPONSIBILITIES.
7. EACH PRIME CONTRACTOR SHALL PROVIDE WORKERS EXPERIENCED IN
THE TRADES AND ACTIVITIES TO BE PERFORMED AND BE FAMILIAR WITH THE
PRODUCTS, MATERIALS, AND FINISHES INVOLVED IN THE SCOPE OF WORK
OF THIS PROJECT. CONTRACTORS SHALL PROVIDE INSTALLERS CERTIFIED
OR ACCREDITED BY APPLICABLE MANUFACTURERS AND/OR TRADE ASSOCIATIONS
WHERE SPECIFIED.
8. EACH PRIME CONTRACTOR SHALL PERFORM DEMOLITION CUTTING IN
SUCH A MANNER THAT PATCHED AREAS MAY BE RETURNED TO UNIFORM CONDITION
AND APPEARANCE WITH SURROUNDINGS. EACH CONTRACTOR SHALL REPAIR
OR REPLACE ANY DAMAGE TO THE SITE CAUSED BY ITS DEMOLITION AND
CONSTRUCTION ACTIVITIES.
9. GENERAL CONTRACTOR SHALL PLAN THE SCHEDULE OF ACTIVITIES TO MAINTAIN
THE SECURITY OF THE BUILDING THROUGHOUT THE CONSTRUCTION PROCESS.
GENERAL CONTRACTOR SHALL LOCK AND SECURE PROJECT AREA AT THE END
OF EACH WORK DAY.
10. EACH PRIME CONTRACTOR SHALL ENSURE THAT ALL WORK AREAS ENCOMPASSED WITHIN
ITS SCOPE OF WORK, INCLUDING THOSE ON ROOFS, SHALL BE IN COMPLIANCE WITH
OSHA STANDARDS AND REQUIREMENTS, INCLUDING ANY FLAGGING, TIE-OFFS,
AND TEMPORARY BARRIERS.
11. THE OWNER RESERVES THE RIGHT TO KEEP ANY ITEMS REMOVED AS SCHEDULED
IN THE DOCUMENTS FOR REMOVAL OR LATER IDENTIFIED IN THE FIELD.
ALL OTHER REMOVED ITEMS SHALL BE COME THE PROPERTY AND RESPONSIBILITY
OF THE CONTRACTOR FOR LEGAL DISPOSAL.
12. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND
FEDERAL CODES, ORDINANCES AND REGULATIONS AS APPLICABLE.
13. THE ARCHITECT AND OWNER ACCEPTS NO RESPONSIBILITY FOR CHANGES OR
DEVIATIONS FROM THE PROJECT DOCUMENTS UNLESS AUTHORIZED VIA
WRITTEN CORRESPONDENCE FROM THE ARCHITECT OR OWNER.
14. THE SERVICES TO BE PERFORMED BY THE ARCHITECT UNDER THE OWNER-ARCHITECT
AGREEMENT ARE INTENDED SOLELY FOR THE BENEFIT OF THE OWNER. NOTHING CONTAINED
HEREIN SHALL CONFER ANY RIGHTS UPON OR CREATE ANY DUTIES ON THE PART OF THE
ARCHITECT TOWARD ANY PERSON(S) NOT A PARTY TO THE OWNER-ARCHITECT AGREEMENT
INCLUDING, BUT NOT LIMITED TO ANY CONTRACTOR, SUBCONTRACTOR, SUPPLIER, OR
THE AGENTS, OFFICERS, EMPLOYEES, INSURERS OR SURETIES OF ANY SUCH PERSON(S).
15. ANY DAMAGE TO EXISTING CONDITIONS OR NEW WORK SHALL BE IMMEDIATELY REPORTED
TO THE OWNER'S REPRESENTATIVE, CONTRACTOR RESPONSIBLE FOR THE DAMAGED WORK,
GENERAL CONTRACTOR AND ARCHITECT. REPAIR OF THE WORK SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR THAT COMMITTED THE DAMAGE. SEE MULTIPLE-CONTRACT SUMMARY
FOR FURTHER INFORMATION.
16. GENERAL CONTRACTOR SHALL FULLY CLEAN WORK SITE AT COMPLETION OF WORK USING
MANUFACTURER RECOMMENDED PRODUCTS AND METHODS. CLEANING SHALL BE COMPLETED
IN ALL WORK AND WORK-ADJACENT AREAS IMPACTED BY CONSTRUCTION. CLEANING SHALL
INCLUDE REMOVAL OF ALL TRASH AND DEBRIS; SWEEPING, VACUUMING AND MOPPING OF
FLOORS; DUSTING OF ALL HORIZONTAL AND VERTICAL SURFACES; CLEANING, POLISHING AND
SANITIZATION OF ALL FIXTURES AND ACCESSORIES; REMOVAL OF SEALANT AND PAINT RESIDUE;
EXTERIOR AND INTERIOR CLEANING OF CASEWORK/MILLWORK; AND CLEANING OF ALL
WINDOWS AND GLASS SURFACES.
17. WHERE APPLICABLE, GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY SIGNAGE FOR
OBSTRUCTED PATHWAYS INDICATING SAFE ROUTES. GENERAL CONTRACTOR TO PROVIDE
TEMPORARY PROTECTION OF ALL WALKWAYS THROUGH FINISHED AREAS WITHIN WORK AREA,
AND THOSE USED FOR ACCESS TO AND FROM THE WORK AREA (INCLUDING ADJACENT GRASS
AND PLANTING) TO PREVENT DAMAGE FROM EQUIPMENT AND CONSTRUCTION ACTIVITIES.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING SITE AT COMPLETION OF THE WORK.
18. EACH PRIME CONTRACTOR/VENDOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS, EQUIPMENT, TEMPORARY FACILITIES, AND APPLICABLE SUB-CONTRACTORS AS REQUIRED TO
PERFORM THE SCOPE OF WORK IDENTIFIED IN THESE DOCUMENTS. SEE SPECIFICATIONS FOR
FURTHER INFORMATION AND SPECIAL EXEMPTIONS.
19 THE PROJECT SHALL HAVE TWO (2) PRIME CONTRACTORS.
GENERAL TRADES (GC)
ELECTRICAL (EC)
SEE ALSO SPECIFICATION SECTION 011200 "MULTIPLE CONTRACT SUMMARY".
20. THROUGHOUT THESE DRAWINGS SCOPES OF WORK ARE ASSIGNED TO EACH
PRIME CONTRACTOR WHERE THE ASSIGNED CONTRACTOR MAY OTHERWISE BE AMBIGUOUS
OR THE ARCHITECT HAS INTENTIONALLY ASSIGNED THE WORK TO A PRIME CONTRACTOR.
EACH PRIME CONTRACTOR SHALL REVIEW THE PROJECT DOCUMENTS AND REQUEST
CLARIFICATION FOR ANY SCOPES OF WORK NOT CLEARLY ASSIGNED OR COMMONLY
INTERPRETED TO BE WITHIN ITS SCOPE OF WORK. IF NO PRIME CONTRACTOR IS SPECIFIED,
THE WORK IS NOT ASSIGNED TO "BY OWNER" OR "BY OTHERS"; AND THE WORK IS NOT
INHERENTLY ATTRIBUTABLE TO A PRIME CONTRACTOR, IT SHALL BE INTERPRETED AS
WITHING THE SCOPE OF THE GENERAL TRADES PRIME CONTRACT.
SEE ALSO SPECIFICATIONS SECTIONS 011200 "MULTIPLE CONTRACT SUMMARY"
AND 011200.01 "WORK COORDINATION SUMMARY" AS APPLICABLE.
21. EXISTING BUILDING DIMENSIONS AND CHARACTERISTICS DEPICTED ARE BASED ON
LIMITED FIELD MEASUREMENTS. SOME DIMENSIONAL VARIATION IS EXPECTED.
IN CASES WHERE CRITICAL DIMENSIONS ARE NOTED SUCH AS MINIMUM ACCESSIBLE
CLEARANCES, GENERAL CONTRACTOR IS TO VERIFY REQUIRED DIMENSIONS PRIOR
TO CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS.
22. DURING DEMOLITION AND CONSTRUCTION, GC SHALL PROTECT ALL EXISTING FINISHES
TO REMAIN, AND PROVIDE TEMPORARY DUST BARRIERS TO PREVENT THE MIGRATION
OF DUST TO PREVIOUSLY FINISHED AREAS OF THE BUILDING. GC SHALL BE RESPONSIBLE
FOR CLEANING ANY AND ALL AREAS AFFECTED BY IMPROPER DUST CONTROL.
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
CODE SUMMARY
AND LIFE SAFETY
PLAN
A-002
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
BUILDING CODE
SUMMARY
INTERNATIONAL BUILDING CODE - 2021
CONSTRUCTION TYPE
AUTOMATIC SPRINKLER SYSTEM
SECTION 602 AND TABLE 601
SECTION 903
TYPE IIB
MEANS OF EGRESS IBC 2021 REQUIRED PROVIDED
MEANS OF EGRESS SIZING
STAIRWAYS
OTHER EGRESS COMPONENTS
STAIRWAYS
ACCESSIBLE STAIRWAY WIDTH
AREA OF REFUGE
EXTERIOR AREA FOR ASSISTED RESCUE
MAXIMUM PATH OF COMMON EGRESS TRAVEL
MAXIMUM EXIT ACCESS TRAVEL DISTANCE
MINIMUM CORRIDOR WIDTH
MAXIMUM DEAD END
MINIMUM NUMBER OF EXITS
SECTION 1005
SECTION 1005.3.1
SECTION 1005.3.2
SECTION 1009 & 1011
SECTION 1009.3
SECTION 1009.6
SECTION 1009.7
SECTION 1006.2.1
SECTION 1017 & TABLE 1017.2
SECTION 1020.2
SECTION 1020.4
SECT.1006 & TABLE 1006.3.1
0.3 INCHES PER OCCUPANT
0.2 INCHES PER OCCUPANT
48"
NO
NO
100' (B/S) / 75' (A)
250'
44"
50'
N/A
SEE LIFE SAFETY PLANS
SEE PLANS
N/A
N/A
SEE LIFE SAFETY PLANS
SEE LIFE SAFETY PLANS
SEE PLANS
N/A
USE AND OCCUPANCY CHAPTER 3
CLASSIFICATION OF WORK
INTERNATIONAL EXISTING BUILDING CODE - 2021
CHAPTER 3
BUILDING AND PROJECT DATA
LEVEL 2
S-1
TABLE 601, 602 & SECTION 705
TABLE 601
TABLE 705.8
TABLE 705.8
SECTION 706
SECTION 707
SHAFT ENCLOSURES (< 4 STORIES)
PRIMARY STRUCTURAL FRAME TABLE 601 AND SECTION 704
BEARING WALLS
EXTERIOR
INTERIOR
EXTERIOR WALL OPENINGS (DIST. > 30 FEET)
FIRE WALLS
FIRE BARRIERS 3 HOURS
3 HOURS
NO LIMIT
FIRE RESISTANCE RTG - IIB IBC 2021 REQUIRED PROVIDED
NONBEARING WALLS AND PARTITIONS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
UNPROTECTED, SPRINKLERED
PROTECTED
FIRE PARTITIONS
SMOKE BARRIERS
SMOKE PARTITIONS
CORRIDOR FIRE RESISTIVE RATING
EXIT PASSAGEWAYS
HORIZONTAL EXITS
OPENING PROTECTIVES
TABLE 601, 602 & SECTION 705
TABLE 601
TABLE 601
TABLE 601
SECTION 708
SECTION 709
SECTION 710
SECTION 708 & TABLE 1020.1
SECTION 1024
SECTION 1026
SECTION 716 & TABLE 716.5
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
NO LIMIT
N/A
N/A
1 HOURS
1 HOUR
NO RATING
1 HOUR
1+ HOURS
1+ HOURS
0 HOURS N/A
1 HOUR
N/A
1 HOUR
PER SECT. 707 | 2 HOURS MIN. N/A
BUILDING DESCRIPTION AND USE 1 STORY WAREHOUSE
BUILDING WITH MEZZANINE,
SPRINKLERED.
EXISTING WAREHOUSE BUILDING W/ MEZZANINE AND
ACCESSORY STORAGE FUNCTIONS.
REQUIRED PROVIDED
REQUIRED
BUILDING AREA BREAKDOWN
1ST FLOOR
YES (EXISTING)
APPLICABLE CODES AND ORDINANCES
2021 IBC: ALL APPLICABLE CHAPTERS
ICC A117.1, 2017 EDITION: ALL APPLICABLE CHAPTERS
ALL APPLICABLE SUB-CODES AND STANDARDS AS AMENDED BY
THE CITY OF READING
PROJECT SCOPE:
COMPREHENSIVE RENOVATIONS TO A PORTION OF THE EXISTING WAREHOUSE SPACE TO CREATE A THEATRICAL STORAGE ROOM WITHIN THE EXISTING BUILDING FOOTPRINT. WORK INCLUDES INTERIOR MODIFICATIONS AND RELATED ADJUSTMENTS TO BUILDING SYSTEMS AS REQUIRED.
NO CHANGE OF OCCUPANCY IS PROPOSED. THE EXISTING SPRINKLER SYSTEM SHALL REMAIN.
EXTERIOR
INTERIOR
18,957 SQ. FT.
NO LIMIT
NO LIMIT
SECTS. 713, 707, 711 & 703.2.1
STAIRWAY WIDTH SECTION 1011.2 44" (36" IF OCC. < 50) N/A
1+ HOURS
CHAPTERS 5, 6, 7, 8 & 9
NOTE: IEBC CRITERIA FOR CHAPTERS 7, 8, 9 & 10 NOT LISTED ABOVE SHALL COMPLY WITH THE NEW CONSTRUCTION REQUIREMENTS SET FORTH IN THE 2018 INTERNATIONAL BUILDING CODE, NFPA 70, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL FUEL GAS CODE, AND ALL LOCAL AMENDMENTS OR OTHER EFFECTIVE CODES/ORDINANCES.
NO CHANGECHAPTER 10
RISK CATEGORY CATEGORY IISECTION 1604
BUILDING HEIGHTS AND AREAS IIB, ONE-STORY, SPRINKLERED, S-1 USE
OCCUPANCY GROUP
CHAPTER 3
HEIGHT
TABLE 504.3
STORIES
TABLE 504.4
FLOOR AREA
TABLE 506.2
ADJ. FLOOR AREA*
SECTION 506.3
* FRONTAGE INCREASE CALCULATION:
W = 30'-0" (ALL FACADES > 30' OPEN) F/P = 1 If = [1 - 0.25]* 30/30=0.75 ALLOWABLE INCREASE
S-1 | STORAGE, MODERATE HAZARD 75' 3 52,500 91,875
PROVIDED APPX. 22'-9" 1 950 18,957 (1ST FL)
ALTERATIONS
CHANGE OF OCCUPANCY
GROSS AREA
TOTAL BUILDING AREA 18,957 SQ. FT.
NOTES:
TABLE 508.4OCCUPANCY SEPARATIONS REQUIRED SEPARATION
1 HOURSTORAGE, LOW HAZARD - STORAGE, MODERATE HAZARD
SEE OCCUPANCY SCHEDULE FOR OCCUPANT LOADS
INTERIOR FINISHES IBC 2021
REQ'D. FLAME SPREAD INDEX, SPRINKLERED
GROUP S-1
TABLE 803.13
C
EXIT STAIRWAYS,
RAMPS &
PASSAGEWAYS
CORRIDORS AND EXIT
ACCESS ENCLOSURES
ROOMS & ENCLOSED
SPACES
C C
53'-9" 68'-9"
A .0
1 A .0
C .1
B.
EXISTING ILLUMINATED
EXIT SIGN AND LTG TO
REMAIN
EXISTING ILLUMINATED
EXIT SIGN AND LTG TO
REMAIN
FE
A .0
DOOR #4
DOOR #3
DOOR #2
DOOR #1
EXIT
EX
IT
EX
IT
EX
IT
THEATRICAL
STORAGE
ROOM
A: 950 SF
WAREHOUSE
A: 17,765 SF
WAREHOUSE
VESTIBULE
A: 182 SF
A
B
C
D
A .0
B.
EXISTING FIRE
EXTINGUISHER
TO REMAIN
OFFICE
A: 163 SF
<LOAD>
AGGREGATE EGRESS LOAD AT EXIT
ALLOWABLE EGRESS LOAD
CLEAR EGRESS WIDTH
LIFE SAFETY LEGEND
OCCUPANTS
ROOM AREA
EGRESS INFORMATION
AREA (sf) PER OCCUPANT
ROOM NUMBER
ROOM NAME
COMMON PATH OF TRAVEL DISTANCE
PRIMARY EGRESS PATH
POINT OF ACCESS TO MULTIPLE EXITS
EXIT ACCESS TRAVEL DISTANCE
SECONDARY EGRESS PATH
APPLICABLE CODES: IBC 2021, IFC 2021, ICC A117.1 - 2017, ADA 2010, OSHA STD. 1910
SIGN TYPE
ID SIGN DESCRIPTION CODE REFERENCE TACTILE TEXT
& BRAILLE PICTOGRAMS
A - LIFE SAFETY & EGRESS
A.01 ACCESSIBLE EXIT IFC 1013.4 YES ISA
B - BUILDING INFORMATION AND WAYFINDING
B.12 ROOM IDENTIFICATION - ID & NAME YES
C - FIRE SAFETY
C.12 FIRE EXTINGUISHER LOCATION IFC 906.6 NO
ICC A117.1
NOTES
ISA
ARROWS KNOCKOUTS TO MATCH EGRESS DIRECTIONA.08 EXIT SIGN (ILLUMINATED; SEE ELEC. DWGS) IFC 1013.1 NO
A.05 NOT AN EXIT YESICC A117.1
SIGN TYPE SCHEDULE
GENERAL SIGNAGE NOTES
1. ALL SIGNS SHALL FOLLOW THE REQUIREMENTS SET FORTH IN THE REFERENCED CODES AND SECTIONS.
2. ALL ACCESSIBLE SIGNAGE TEXT, COLORS, PICTOGRAMS/SYMBOLS, AND BRAILLE SHALL CONFORM TO THE REQUIREMENTS OF THE 2017 ICC A117.1.
3. GENERAL CONTRACTOR SHALL VERIFY ALL SIGNAGE QUANTITIES AND LOCATIONS.
4. REFER TO THE LIFE SAFETY AND/OR SIGNAGE PLANS FOR SIGN LOCATIONS.
5. GENERAL CONTRACTOR SHALL VERIFY/CONFIRM FINAL LOCATIONS OF ALL SIGNS PER CODE REQUIREMENTS AND THE AUTHORITY HAVING JURISDICTION.
6. SIGNAGE FOR RATED BARRIERS SHALL BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL OR PARTITION, AND SPACED AT INTERVALS NOT EXCEEDING 30 FEET
ALONG THE LENGTH OF THE WALL OR PARTITION. THE LETTERING SHALL NOT BE LESS THAN 3" IN HEIGHT WITH A MINIMUM OF 3/8-INCH STROKE IN A CONTRASTING COLOR.
7. ALL SIGNAGE INDICATED FOR INSTALLATION ON GLAZED SURFACES TO BE PROVIDED WITH MATCHING BACK PLATE TO BE INSTALLED ON OPPOSITE SIDE OF GLAZING.
8. ALL TEXT SHALL COMPLY WITH VISUAL CHARACTER REQUIREMENTS OF ICC A117.1 UNLESS EXEMPTED.
9. EXIT SIGNS LOCATED IN EXIT ACCESS CORRIDORS OR EXIT PASSAGEWAYS SHALL BE INSTALLED NO FURTHER THAN 100' FROM NEAREST VISIBLE EXIT SIGN.
10. PICTOGRAMS AND NON-PERMANENT ROOM IDENTIFICATION TEXT ARE NOT REQUIRED TO BE RAISED/TACTILE. ROOM IDs/NUMBERS AND PERMANENT ROOM INFORMATION
TEXT SHALL ALWAYS BE RAISED/TACTILE.
11. OVERALL SIGNAGE DIMENSIONS MAY VARY BY PROJECT-SPECIFIC DESIGN SELECTIONS, USE-CASE AND MANUFACTURER. SIGN DIMENSIONS SHALL BE ADEQUATE TO
CONTAIN ALL REQUIRED MESSAGING IN A MANNER COMPLIANT WITH ALL APPLICABLE CODES CITED IN THESE DRAWINGS AND THE AUTHORITY HAVING JURISDICTION.
FE
lb s.
5' -0
" M A
X.
FE
lb s.
3'
-6 " M
A X.
4" M
IN
WALL MOUNTED
FIRE EXTINGUISHER
<40 lbs.
FACE OF WALL
BRACKET
" M
A X
45.00°
" M
IN
9" MIN.
18" MIN.
" M
IN
FIGURE 703.3.10 : HEIGHT OF RAISED CHARACTERS ABOVE FLOOR
SEE FIGURE 703.4.5 FOR BRAILLE REQUIREMENTS
CL
FIGURE 703.3.11 : LOCATION OF SIGNS AT DOORS
LETTERING
HERE
CL
CLEARANCE CENTERED ON
RAISED CHARACTERS
RECESSED BRAILLE PANEL
ISA (WHERE APPLICABLE)
RAISED LETTERING
RED .040" POLYSTYRENE
5/8" FLAT PRINTED
LETTERING
ACRYLIC PLATE
ACRYLIC PLATE
1" RAISED LETTERING
RECESSED BRAILLE PANEL
RAISED LETTERING
ACRYLIC PLATE
RECESSED BRAILLE PANEL
RAISED LETTERING
ROOM IDENTIFICATION SIGNAGE NOTES:
1. REPRESENTATIONS OF SIGNS ARE APPROXIMATE. MATCH OWNER SIGN STANDARDS.
2. MATCH OWNER'S EXISTING SIGN STANDARD FONTS & COLORS
EXIT
TYPE A.01
FIRE
E X T I N G U I S H E
RSTORAGE
104C
1 LINE
TYPE A.05
NOT AN
EXIT
TYPE B.12 TYPE C.12
1 LIFE SAFETY PLAN
SCALE: 1/8" = 1'-0"
SCALE: 1/2" = 1'-0"2 FIRE EXTINGUISHER DETAIL
SCALE: 1/2" = 1'-0"3 SIGNAGE MOUNTING DETAIL
SCALE: 3" = 1'-0"4 SIGNAGE ELEVATIONS
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
DEMOLITION
PLAN
AD-101
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
AD-101
AD-101
2.41.01
2.01.01
2.01.01
2.01.02 2.41.05 2.01.02 2.41.05
2.41.01
2.01.03
2.01.03
2.01.01
2.01.10
2.01.10
2.01.10
2.01.10
2.01.10
2.01.10
2.41.05
2.01.10
2.01.16
2.41.04
2.41.05
2.
.0
2.41.07
2.01.19
2.01.192.01.19
2.01.212.01.21
2.01.21
WAREHOUSE
VESTIBULE
EXIST.
EXIST.
EXIST.
EXIST.
STORAGE
ROOM
A
B
C
D
2.01.12
2.
.1
2.01.04
2.01.05 2.41.02 2.01.05 2.01.06
2.41.03 2.41.03
2.41.03
2.41.03
2.41.032.41.03
2.01.082.01.08
2.01.082.01.08
2.01.07
2.01.07
2.01.07
2.41.02
TYP. FOR 8
WAREHOUSE
VESTIBULE
CLG 9'-0"
STORAGE
ROOM
CLG 23'-6 1/2"
A
B
C
D
2.01.04
2.01.06
2.41.02
EXISTING DOOR TO REMAIN
REMOVE EXISTING WALL FROM FLOOR
TO 6" BELOW EXISTING CEILING
FLOOR PLAN DEMOLITION LEGEND
REMOVE EXISTING DOOR
EXISTING WALL TO REMAIN
REMOVE EXISTING WINDOW
DEMOLITION RCP LEGEND
2.01.03
2.01.01
2.01.01
2.01.02
2.41.01
2.01.03
2.41.03 2.41.032.41.03
2.41.022.41.02
2.01.08
2.01.07
2.01.082.01.082.01.08
2.41.04
2.41.05
2.01.02
2.01.09
2.01.04
2.01.16
2.01.15
2.01.09 2.01.062.01.06
2.41.05
2.41.01
2.01.022.01.02
2.41.04
2.01.01
2.01.07
2.41.02
2.01.09
2.01.082.01.08
2.01.08
2.01.04
2.41.01
2.41.05
2.41.03
2.41.03
2.01.06
2.01.06
AREA OF
WORK
.1
.1
KEYED NOTES
02 DEMOLITION
2.01 EXISTING CONDITIONS
2.01.01 EXISTING COLUMN TO REMAIN.
2.01.02 EXISTING CONCRETE SLAB TO REMAIN.
2.01.03 EXISTING DOOR TO REMAIN.
2.01.04 EXISTING GAS-FIRED (REZNOR) UNIT HEATER TO REMAIN.
PROTECT FROM DAMAGE DURING CONSTRUCTION.
COORDINATE WITH MECHANICAL.
2.01.05 EXISTING ROOF STRUCTURE, INSULATION, AND MEP
SYSTEMS TO REMAIN EXPOSED.
2.01.06 EXISTING SPRINKLER SYSTEM TO REMAIN. PROTECT
EXISTING SPRINKLER HEADS DURING CONSTRUCTION
ACTIVITIES.
2.01.07 EXISTING STEEL BEAM TO REMAIN.
2.01.08 EXISTING STEEL ROOF PURLINS TO REMAIN.
2.01.09 EXISTING CORRUGATED SIDING TO REMAIN.
2.01.10 EXISTING WINDOW TO REMAIN; PROTECT AS REQUIRED.
AT THE COMPLETION OF WORK, CONTRACTOR TO CLEAN
ALL WINDOW FRAMES AND GLAZING THROUGHOUT
SPACE.
2.01.12 EXISTING BATT INSULATION TO REMAIN.
2.01.15 EXISTING F.A. DEVICE TO REMAIN. PROTECT DURING
CONSTRUCTION.
2.01.16 EXISTING THERMOSTAT TO REMAIN. PROTECT DURING
CONSTRUCTION.
2.01.19 EXISTING GYPSUM BOARD SHEATHING AND PLYWOOD
WAINSCOT TO REMAIN.
2.01.21 EXISTING FLOOR ACCESS TO REMAIN.
2.41 SELECTIVE DEMOLITION
2.41.01 REMOVE EXISTING PEGBOARD AND MISCELLANEOUS
WALL FINISHES; PREPARE FOR NEW WALL CONSTRUCTION.
2.41.02 REMOVE EXISTING LIGHT FIXTURES BY E.C.
2.41.03 CAREFULLY REMOVE AND/OR PIN BACK EXISTING ROOF
INSULATION ALONG WALLS AS REQUIRED FOR WORK.
2.41.04 REMOVE WOOD STUD FUR-OUTS.
2.41.05 REMOVE EXISTING PLYWOOD SHEATHING.
2.41.07 REMOVE EXISTING DOOR PANEL. EXISTING FRAME TO
REMAIN.
1 DEMOLITION FLOOR PLAN
SCALE: 1/4" = 1'-0" 2 DEMOLITION REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
3 EXISTING CONDITION PHOTO 4 EXISTING CONDITION PHOTO
KEY PLAN
SCALE: 1/16" = 1'-0"
GENERAL DEMOLITION NOTES
1. PRIOR TO SUBMISSION OF BID EACH CONTRACTOR SHALL VISIT THE SITE TO VERIFY THE EXTENT OF
DEMOLITION WORK REQUIRED AND VERIFY THE EXISTING CONDITIONS AND MATERIALS TO BE
DEMOLISHED. CONTRACTOR TO FIELD-VERIFY ROUTING OF ALL EXISTING CONCEALED UTILITIES
PRIOR TO DEMOLITION.
2. SEE SPECIFICATIONS FOR ASSIGNMENT OF TEMPORARY LIGHTING AND POWER, HVAC, AND
WATER FACILITIES DURING DEMOLITION. USE OF EXISTING MEP INFRASTRUCTURE IS PERMISSIBLE TO EXTENT POSSIBLE BASED ON THE DEPICTED SCOPE OF WORK. !!! VERIFY WITH OWNER !!!!
3. THE DEMOLITION SHOWN AND INDICATED ON THE DEMOLITION DRAWINGS IS NOT A COMPLETE INDICATION OF THE DEMOLITION REQUIRED FOR THIS PROJECT. ALL MISCELLANEOUS DEMOLITION REQUIRED FOR THIS PHASE OF THE PROJECT, AND THE INTENT OF THE CONSTRUCTION DOCUMENTS, SHALL BE COMPLETED.
4. BEFORE PROCEEDING WITH DEMOLITION OF ANY EXISTING CONSTRUCTION, THE CONTRACTOR
MUST VERIFY THAT IT IS NOT SUPPORTING EXISTING CONSTRUCTION WHICH IS TO REMAIN.
IF IN DOUBT, NOTIFY THE ARCHITECT BEFORE REMOVING THE MEMBERS.
5. DEMOLISHING CONTRACTOR TO PROVIDE TEMPORARY BRACING, SHORING, OR OTHER
PROTECTION AS REQUIRED UNTIL THE WORK IS COMPLETE.
6. DEMOLITION IS TO BE DONE IN A MANNER WHICH WILL NOT DAMAGE EXISTING CONSTRUCTION TO REMAIN. PROVIDE TEMPORARY PROTECTION TO EXISTING FINISHES & MATERIALS AS REQUIRED.
7. DEBRIS FROM DEMOLITION MUST NOT BE STORED IN A MANNER WHICH WILL OVERLOAD
THE EXISTING CONSTRUCTION.
8. THE SCOPE OF WORK INCLUDES THE LEGAL DISPOSAL, OFF SITE, OF ALL
CONSTRUCTION/DEMOLITION DEBRIS. NO CONSTRUCTION DEBRIS OR TRASH
IS TO BE PLACED IN THE PROPERTY OWNERS DUMPSTERS WITHOUT AUTHORIZATION.
!!!! VERIFY w/ OWNER !!!!!
9. ALL SOLID WALLS, PARTITIONS, AND FURRED AREAS WHICH ARE SHOWN AS BEING REMOVED
SHALL INCLUDE DOORS, WINDOWS, FRAMES, FINISHES, SHELVING, ETC. THAT ARE PART OF
THOSE WALLS AND PARTITIONS.
10. THE OWNER RESERVES THE RIGHT TO HAVE THE CONTRACTOR TURN OVER ANY
SALVAGED ITEMS OR MATERIALS.
11. PARTIAL REMOVAL OF EXISTING PARTITIONS OR FINISHES IS TO BE PERFORMED AS TO ALLOW
FOR REFINISHING FOR NEW CONSTRUCTION. DEMOLITION OF CMU PARTITIONS THAT WILL
REMAIN EXPOSED SHALL INCLUDE REMOVAL OF ENTIRE BLOCKS AS TO ALLOW FOR
"TOOTHING" OF NEW MASONRY OR INSTALLATION OF BULLNOSE CMU'S.
12. INFILL/PATCH OPENINGS WHERE INDICATED ON THE DRAWINGS WITH SIMILAR, COMPATIBLE
MATERIALS AND METHODS SUCH AS TO ENSURE UNIFORM APPEARANCE AND
PERFORMANCE. SEE SPECIFICATIONS FOR EXTENT OF FINISHING REQUIRED AND
CONTRACTOR ASSIGNMENTS.
13. WHERE FINISHES OR SURFACE-MOUNTED ELEMENTS ARE SCHEDULED FOR REMOVAL
FROM SUBSTRATE SCHEDULED TO REMAIN; CLEAN AND PREPARE SUBSTRATE FOR NEW
FINISHES TO CONDITION COMPLIANT WITH MANUFACTURER'S SPECIFICATIONS.
14. HAZARDOUS MATERIALS REMEDIATION IS NOT ANTICIPATED FOR AREAS OF WORK.
IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED IN THE COURSE OF
DEMOLITION, NOTIFY ARCHITECT AND OWNER IMMEDIATELY.
15. DEMOLITION OF MISCELLANEOUS SURFACE-MOUNTED ITEMS IN SPACES TO RECEIVE
NEW FINISHES OR FINISHES MAINTENANCE SHALL BE INCLUDED AS PART OF THIS SCOPE.
16. UNLESS NOTED OTHERWISE, ALL DEMOLITION DIMENSIONS ARE TAKEN FROM
FINISH FACE OF EXISTING ELEMENTS.
17. OWNER SHALL REMOVE ITEMS STORED IN WORK AREA PRIOR TO DEMOLITION.
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
FLOOR PLANS
A-101
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
1 A-401
'-8
7'-7 1/2" 11'-2 1/2"
3' -0
/2
'-7
/2
'-0
'-0
18'-10"
3.30.01 9.65.01 9.92.01
3.30.01 9.65.01 9.92.01
2.01.01
2.01.01
2.01.03 9.92.02
2.01.01
2.01.03 9.92.02
10.56.01
10.56.02
8.11.01
REPLACE BROKEN
DOOR CLOSER
10.56.02
10.56.02
12.50.01
12.50.01
10.56.01
10.56.01
THEATRICAL
STORAGE
ROOM
EXIST
RB-1
P-1,P-3
EXIST./P.2
WAREHOUSE
EXIST.
EXIST.
EXIST.
EXIST.
WAREHOUSE
VESTIBULE
EXIST.
EXIST.
EXIST.
EXIST.
101.1
102.1
A
B
C
D
A-501
A-501
A-501
'-8
5/
8"
'-7
/4
9.
.0
AREA OF
WORK
.1
.1
ROOM NAME
ROOM NUMBER
FLOOR FINISH
CEILING FINISH
WALL FINISH
WALL BASE
4.
5A
EXISTING DOOR TO REMAIN
EXISTING WALL TO REMAIN
EXISTING WALL TO REMAIN
EXISTING COLUMN TO REMAIN
FLOOR PLAN LEGEND
NEW WALL CONSTRUCTION
NEW DOOR
WALL ID; SEE PARTITION TYPES
DOOR ID; SEE DOOR SCHEDULE
AAA
B
B
B
B
C
C C
D
D
D
D
26.27.01 TYP.
SEE ELECTRICAL NOTE #6
THEATRICAL
STORAGE
ROOM
WAREHOUSE
WAREHOUSE
VESTIBULE
101.1
102.1
A
B
C
D
HDMI
USB
GFI
48" C
D, OS
2, D
O S
D
FAX
C
AE3
SD
POWER-DATA LEGEND
DUPLEX OUTLET, 18" AFF TYP.
CEILING-MOUNTED DEVICE; FLUSH MOUNTED
FLOOR-MOUNTED DEVICE; FLUSH GANG BOX w/ COVER
IP PHONE PORT; RJ45; CAT-6 WIRING
DATA PORT; RJ45; CAT-6 WIRING
HDMI PORT; HDMI 2.1 WIRING
USB PORT; USB 3.1-COMPLIANT
QUAD OUTLET; PROVIDE TWO PARALLEL CIRCUITS & CONSISTENTLY
IDENTIFY CIRCUIT A/B EACH LOCATION; 18" AFF TYP.
GFI-PROTECTED DUPLEX OUTLET, 18" AFF TYP.
POWER
SIGNAL
MOUNTING TYPES
WALL-MOUNTED DEVICE GANG BOX; FLUSH MOUNT
(RECESSED BOXES BEHIND WALL-MOUNTED DISPLAYS)
SPECIFIED MOUNTING HEIGHT A.F.F.
"C" DENOTES MOUNTING HEIGHT 8" ABV. ADJ. COUNTERTOP
LIGHTING LEGEND
SINGLE POLE SWITCH - 20 AMP - MOUNT 46" AFF
TWO POLE SINGLE THROW SWITCH - 20 AMP - MOUNT 46" AFF
OCCUPANCY SENSOR LIGHT SWITCH - 20 AMP - MOUNT 46" AFF
DIMMER LIGHT SWITCH w/ INTEGRAL OCC SENSOR
- TYPE & SIZE FOR LOAD SERVED - MOUNT 46" AFF
RECESSED LIGHT
EXIT LIGHT FIXTURE
NORMAL & EMERGENCY POWER
3-WAY DIMMER LIGHT SWITCH - TYPE & SIZE FOR LOAD SERVED
- MOUNT 46" AFF
SUSPENDED HIGH-BAY
LIGHT FIXTURE
DIMMER LIGHT SWITCH - TYPE & SIZE FOR LOAD SERVED
- MOUNT 46" AFF
WIRING - CONCEALED AS SPECIFIED U.N.O.
2-12 or 3-12 AWG WITH SEPARATE GROUND WIRE
AS APPLICABLE TO CIRCUIT TYPE
INTERCONNECTED SMOKE DETECTOR/ALARM TIED
INTO EXISTING BUILDING SYSTEM
ANALOG PHONE PORT; RJ12
A A
A A
A A
A A
A-501
A-501
EQ. EQ.
'-9
/4
'-0
'-8
/4
2.01.04
7.21.01
7.21.01
7.21.01
7.21.017.21.01
2.01.05 2.01.06 9.92.03
2.01.05 2.01.06 9.92.03
23.34.01
2.01.07 9.92.03
2.01.08 9.92.03 2.01.08 9.92.03
2.01.08 9.92.03 2.01.08 9.92.03
2.01.07 9.92.03
2.01.07 9.92.03
23.34.01
26.50.0126.50.01
26.50.0126.50.01
26.50.0126.50.01
26.50.0126.50.01
HVLS-1
HVLS-2
SEE NOTE 4
SEE NOTE 5
SEE NOTE 4
5.12.01 9.92.03 5.12.01 9.92.03
5.12.01 9.92.03 5.12.01 9.92.03
FANX
X
UH
THEATRICAL
STORAGE
ROOM
CLG 23'-6 1/2"
WAREHOUSE
CLG 23'-6 1/2"
WAREHOUSE
VESTIBULE
CLG 9'-0"
A
B
C
D
23.34.02
2.01.04
23.38.01
2.01.06
26.50.01
REFLECTED CEILING
PLAN LEGEND
UH
KEYED NOTES
02 DEMOLITION
2.01 EXISTING CONDITIONS
2.01.01 EXISTING COLUMN TO REMAIN.
2.01.03 EXISTING DOOR TO REMAIN.
2.01.04 EXISTING GAS-FIRED (REZNOR) UNIT HEATER TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION.
COORDINATE WITH MECHANICAL.
2.01.05 EXISTING ROOF STRUCTURE, INSULATION, AND MEP SYSTEMS TO REMAIN EXPOSED.
2.01.06 EXISTING SPRINKLER SYSTEM TO REMAIN. PROTECT EXISTING SPRINKLER HEADS DURING CONSTRUCTION ACTIVITIES.
2.01.07 EXISTING STEEL BEAM TO REMAIN.
2.01.08 EXISTING STEEL ROOF PURLINS TO REMAIN.
03 CONCRETE
3.30 CAST-IN-PLACE CONCRETE
3.30.01 CLEAN EXISTING CONCRETE SLAB.
05 METALS
5.12 STRUCTURAL STEEL FRAMING
5.12 3" x 3" x 1/4" ANGLE IRON AND FAN SUPPORT FRAMING BY GC.
5.12.01
07 THERMAL AND MOISTURE PROTECTION
7.21 THERMAL INSULATION
7.21.01 PATCH, REPAIR, AND SECURE REMAINING AND DISTURBED INSULATION, INCLUDING AREAS AFFECTED BY
DEMOLITION, TO MATCH EXISTING AND PROVIDE A CONTINUOUS AND NEAT APPEARANCE.
08 OPENINGS
8.11 HOLLOW METAL DOORS AND FRAMES
8.11.01 SCHEDULED DOOR AND FRAME, PRIMED AND PAINTED. COORDINATE w/ DOOR SCHEDULE.
09 FINISHES
9.29 GYPSUM BOARD
9.29.03 EXTEND GYPSUM BOARD FROM TOP OF EXISTING GYPSUM BOARD TO UNDERSIDE OF ROOF DECK. MATCH EXISTING
SHEATHING THICKNESS.
9.65 RESILIENT FLOORING
9.65.01 6" HIGH THERMOPLASTIC RUBBER WALL BASE FOR PERIMETER OF ROOM OR CORRIDOR. BASIS OF DESIGN:
JOHNSONITE OR TARKETT; COLOR AS SELECTED BY ARCHITECT.
9.92 INTERIOR PAINTING
9.92.01 PRIME AND PAINT (2 COATS) ALL WALLS IN ROOM, UNLESS SPECIFIC WALLS NOTED OTHERWISE. PAINT, INCLUDING
ALL EXPOSED COLUMNS, FROM FLOOR TO UNDERSIDE OF ROOF DECK.
9.92.02 PREP AND PAINT TWO (2) COATS EXISTING DOOR AND FRAME, INCLUDING ALL CASINGS AND TRIMS.
9.92.03 PREP AND PAINT TWO (2) COATS EXISTING ROOF STRUCTURE IN ITS ENTIRETY w/ DRYFALL PAINT.
10 SPECIALTIES
10.56 STORAGE ASSEMBLIES
10.56.01 PROVIDE AND INSTALL NEW FIVE (5) TIER, 72" LENGTH x 24" DEEP SHELVING SYSTEM. PROVIDE WOOD BLOCKING IN
WALL AS REQUIRED FOR SECURE MOUNTING. BASIS OF DESIGN: E-Z SHELVING SYSTEMS, INC. CANTILEVER METAL
STORAGE SYSTEM, OR EQUAL.
10.56.02 HEAVY DUTY MOBILE GARMENT RACK; BY OWNER.
12 FURNISHINGS
12.50 FURNITURE
12.50.01 WORK TABLE; BY OWNER
23.34 HVAC FANS
23.34.01 NEW HIGH VOLUME, LOW SPEED (HVLS) CEILING FAN MOUNTED TO ROOF STRUCTURE, BY EC. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS. COORDINATE REQUIRED FAN CLEARANCES w/ ALL OTHER CEILING
MOUNTED FIXTURES; SEE ELECTRICAL NOTES 1 & 2.
23.34.02 WALL MOUNTED FAN CONTROLLER. PROVIDE ALL WIRING AND CABLES PER MANUFACTURER'S REQUIREMENTS. SEE
NOTE #5.
26 ELECTRICAL
26.27 WIRING DEVICES
26.27.01 NEW 20A DUPLEX OUTLET AT 18" AFF, TYP.
26.50 LIGHTING
26.50.01 INSTALL NEW HIGH-BAY LINEAR LED LIGHT FIXTURES IN NEW LOCATION AS SHOWN ON PLAN. SEE ELECTRICAL NOTE
#2.
1 FLOOR PLAN
SCALE: 1/4" = 1'-0"
KEY PLAN
SCALE: 1/16" = 1'-0"
2 POWER PLAN
SCALE: 1/4" = 1'-0" 3 REFLECTED CEILING AND LIGHTING PLAN
SCALE: 1/4" = 1'-0"
ELECTRICAL NOTES:
1. BASIS OF DESIGN: BIG ASS FANS E SERIES MODEL: E7
INPUT POWER & BREAKER: 110-125 VAC, SINGLE PHASE, 50/60 Hz, 10 A
PROVIDE EXTENSION TUBE, LENGTH AS REQUIRED TO MEET MOUNTING HEIGHT.
MOUNT UNIT TO STRUCTURE PER MANUFACTURER REQUIREMENTS. PROVIDE SAFETY CABLE
AND ALL REQUIRED ACCESSORIES.
PROVIDE DEDICATED CEILING MOUNTED RECEPTACLE FOR EACH FAN UNIT.
CONTROLLER: WALL MOUNTED w/ SINGLE GANG JUNCTION BOX;
2. E.C. TO PROVIDE AND INSTALL ALL FANS, CONTROL DEVICES AND WIRING PER DRAWINGS
AND MANUFACTURER'S REQUIREMENTS.
3. E.C. CONNECT ALL EMERGENCY LIGHT FIXTURES, BATTERY PACKS, AND EXIT SIGNS
TO AN UNSWITCHED HOT LEG OF THE AREA LIGHTING CIRCUIT.
4. E.C. MOUNT DISCONNECT SWITCH ON STRUCTURE WITHIN SIGHT OF UNIT. COORDINATE
EXACT LOCATION IN FIELD.
5. E.C. ROUTE BRANCH CIRCUIT WIRING FOR FANS VIA CONTROLLER.
6. E.C. TO PROVIDE FOUR (4) 20A CIRCUITS CORRESPONDING TO THE LOCATIONS A THROUGH D
ON THE POWER PLAN. INSTALL CIRCUITS AND BREAKERS IN NEAREST AVAILABLE PANEL WITH
SUITABLE CAPACITY.
FINISH LEGEND
RB-1 RUBBER BASE
COLOR AS SELECTED BY ARCHITECT FROM MANUF. FULL RANGE
P-1 PAINT - WALLS
P-2 PAINT - STEEL
P-3 PAINT - DOORS AND FRAMES
ALL PAINT COLORS AS SELECTED BY ARCHITECT
ELECTRICAL GENERAL NOTES
1. THE CONTRACTOR SHALL PROVIDE ALL CIRCUITS (FEEDER AND BRANCH) WITH AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. TABLE 250-122
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY MISCELLANEOUS STEEL REQUIRED FOR MOUNTING ELECTRICAL EQUIPMENT.
3. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DRAWINGS AND DETAILS TO COORDINATE THE EXACT LOCATION OF ALL ELECTRICAL DEVICES OR EQUIPMENT
TO BE INSTALLED. DRAWINGS SHALL NOT BE SCALED.
4. ALL WIRING TO BE INSTALLED IN CONDUIT, BY E.C. ALL CONDUIT TO BE PAINTED TO MATCH ADJACENT WALL OR CEILING SURFACE, BY G.C.
5. SURFACE RACEWAY FOR WIRING SHALL BE PERMITTED AT OWNER'S DISCRETION. EXPOSED WIRING SHALL ONLY BE PERMITTED IN UNFINISHED AREAS AS ALLOWABLE BY THE NEC.
6. OUTLETS MOUNTED BACK-TO-BACK AND/OR THE USE OF THROUGH BOXES IS NOT PERMITTED.
7. THE CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING AND PATCHING OF EXISTING SURFACES REQUIRED FOR HIS WORK. PATCHING SHALL INCLUDING ALL LABOR AND
MATERIALS EXCEPT FINAL FINISHES.
8. THE CONTRACTOR SHALL COORDINATE ALL DEVICES ASSOCIATED WITH MECHANICAL AND ARCHITECTURAL EQUIPMENT INDICATED TO HAVE POWER CONNECTIONS WITH CONTRACTOR PROVIDING EQUIPMENT PRIOR TO ORDERING DEVICES AND ROUGH-INS. THE CONTRACTOR SHALL REQUEST SHOP DRAWINGS
AND/OR DATA SHEETS FOR ALL EQUIPMENT REQUIRING POWER PRIOR TO ROUGH-IN.
9. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL PROVIDE FINAL POWER CONNECTIONS TO ALL POWERED EQUIPMENT FURNISHED BY OTHER CONTRACTORS AND THE OWNER INCLUDING, BUT NOT LIMITED TO, AIR HANDLING EQUIPMENT, COOLING EQUIPMENT, ETC.
NOTE: SUPPORT FRAMING FOR CEILING FANS
TO BE PROVIDED AND INSTALLED BY GC.
FANS AND MOUNTING BRACKETS TO BE
PROVIDED AND INSTALLED BY EC.
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
INTERIOR
ELEVATIONS
A-401
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
2.01.01 9.92.01
2.01.01 9.92.01
2.01.01 9.92.01
9.29.02 9.92.01
2.01.07 9.92.03
2.01.07 9.92.03
9.65.01
9.29.02 9.92.01
26.50.0126.50.0126.50.01 26.50.01
2.01.10
2.01.10
7.21.01
6.16.01 9.92.01 6.16.01 9.92.01
2.01.04
23.34.01 23.34.01TYP.
TYP.
2.01.07 9.92.03
T.O. PLYWOOD
8'-0" A.F.F.
FINISH FLOOR
0'-0"
FAN MOUNTING HT.
18'-6" A.F.F.
B.O. LIGHT FIXTURE
20'-6" A.F.F.
A-501
2.01.08 9.92.03
6.16.01 9.92.01 6.16.01 9.92.01
2.01.07 9.92.03
9.65.01
26.50.01 26.50.01
9.29.02 9.92.01 9.29.02 9.92.01
T.O. PLYWOOD
8'-0" A.F.F.
FINISH FLOOR
0'-0"
A-501
7.21.01
A-401
A-401
2.01.07 9.92.03
2.01.07 9.92.03
2.01.07 9.92.03
2.01.14 9.92.04
9.65.01
10.56.01 10.56.0110.56.01
23.34.01
26.50.01 26.50.0126.50.0126.50.01
23.34.01
8.11.02
101.1
7.21.01
9.29.02 9.92.01 9.29.02 9.92.01
6.16.01 9.92.01 6.16.01 9.92.01
9.29.03 9.92.01 9.29.03 9.92.01
2.01.19 9.92.01 2.01.19 9.92.01
SEE:
SEE:
5.12.01 9.92.03
5.12.01 9.92.03
EXISTING PLYWOOD
WAINSCOT TO REMAIN
T.O. PLYWOOD
8'-0" A.F.F.
FINISH FLOOR
0'-0"
FAN MOUNTING HT.
18'-6" A.F.F.
B.O. LIGHT FIXTURE
20'-6" A.F.F.
9.92.01
A-501
10'-0 1/4"
2.01.19 9.92.01 2.01.19 9.92.01
2.01.08 9.92.03
2.01.03 9.92.02
9.65.01
9.22.02 9.29.01
2.01.08 9.92.03
26.50.0126.50.01
10.56.01
2.01.03 9.92.02
7.21.01
2.01.19 9.92.01 2.01.19 9.92.01
2.01.04
2.01.16
2.01.20
EXISTING DUCTWORK
3' -1
1/
2"
EXISTING PLYWOOD
WAINSCOT TO REMAIN
B.O. OPENING
14'-4" +/-
FINISH FLOOR
0'-0"
2'-0"
3'-0" 3'-0"
6'-0"
7' -0
1' -6
1'
-6
1' -6
1'
-6
PROVIDE IN WALL
BLOCKING AS
REQUIRED FOR
SECURE MOUNTING
SHELF UPRIGHT
CANTILEVERED
SHELF BRACKET
SOLID 16ga. GALVANIZED STEEL SHELF w/ FRONT BENT FASCIA AND
BENT BACK EDGE
ANTI-SWAY STEEL STRAP
CROSS BRACES PER MANUF.
REQUIREMENTS
FULL HT. SOLID END PANELS;
MATCH SELF DEPTH
FOOT BRACKET w/
BASE CLOSURE
FOOT BRACKET w/
BASE CLOSURE
10.56.01
10.56.01
SECTION A-A ELEVATION
KEYED NOTES
02 DEMOLITION
2.01 EXISTING CONDITIONS
2.01.01 EXISTING COLUMN TO REMAIN.
2.01.03 EXISTING DOOR TO REMAIN.
2.01.04 EXISTING GAS-FIRED (REZNOR) UNIT HEATER TO REMAIN. PROTECT
FROM DAMAGE DURING CONSTRUCTION. COORDINATE WITH
MECHANICAL.
2.01.07 EXISTING STEEL BEAM TO REMAIN.
2.01.08 EXISTING STEEL ROOF PURLINS TO REMAIN.
2.01.10 EXISTING WINDOW TO REMAIN; PROTECT AS REQUIRED. AT THE
COMPLETION OF WORK, CONTRACTOR TO CLEAN ALL WINDOW
FRAMES AND GLAZING THROUGHOUT SPACE.
2.01.14 EXISTING DOOR FRAME TO REMAIN.
2.01.16 EXISTING THERMOSTAT TO REMAIN. PROTECT DURING
CONSTRUCTION.
2.01.19 EXISTING GYPSUM BOARD SHEATHING AND PLYWOOD WAINSCOT
TO REMAIN.
2.01.20 EXISTING FIRE STROBE TO REMAIN.
05 METALS
5.12 STRUCTURAL STEEL FRAMING
5.12 3" x 3" x 1/4" ANGLE IRON AND FAN SUPPORT FRAMING BY GC.
5.12.01
06 WOODS, PLASTICS AND COMPOSITES
6.16 SHEATHING
6.16.01 1/2" FIRE-RATED PLYWOOD STRUCTURAL SHEATHING; PAINTED.
07 THERMAL AND MOISTURE PROTECTION
7.21 THERMAL INSULATION
7.21.01 PATCH, REPAIR, AND SECURE REMAINING AND DISTURBED
INSULATION, INCLUDING AREAS AFFECTED BY DEMOLITION, TO
MATCH EXISTING AND PROVIDE A CONTINUOUS AND NEAT
APPEARANCE.
08 OPENINGS
8.11 HOLLOW METAL DOORS AND FRAMES
8.11.02 SCHEDULED DOOR PANEL; COORDINATE w/ DOOR SCHEDULE.
09 FINISHES
9.22 NON-STRUCTURAL METAL FRAMING
9.22.02 INFILL EXISTING OPENING w/ NEW 20 ga. METAL STUDS @ 16" O.C.
MATCH EXISTING FRAMING DEPTH TO ALLOW WALL SURFACE TO
FINISH FLUSH w/ EXISTING WALL SURFACE ON BOTH SIDES.
9.29 GYPSUM BOARD
9.29.01 5/8" GYPSUM BOARD. FINISH FLUSH w/ ADJACENT WALL SURFACE.
TYPICAL FOR BOTH SIDES OF WALL INFILL.
9.29.02 5/8" GYPSUM BOARD FROM TOP OF PLYWOOD SHEATHING TO
UNDERSIDE OF ROOF DECK.
9.29.03 EXTEND GYPSUM BOARD FROM TOP OF EXISTING GYPSUM BOARD
TO UNDERSIDE OF ROOF DECK. MATCH EXISTING SHEATHING
THICKNESS.
9.65 RESILIENT FLOORING
9.65.01 6" HIGH THERMOPLASTIC RUBBER WALL BASE FOR PERIMETER OF
ROOM OR CORRIDOR. BASIS OF DESIGN: JOHNSONITE OR
TARKETT; COLOR AS SELECTED BY ARCHITECT.
9.92 INTERIOR PAINTING
9.92.01 PRIME AND PAINT (2 COATS) ALL WALLS IN ROOM, UNLESS
SPECIFIC WALLS NOTED OTHERWISE. PAINT, INCLUDING ALL
EXPOSED COLUMNS, FROM FLOOR TO UNDERSIDE OF ROOF DECK.
9.92.02 PREP AND PAINT TWO (2) COATS EXISTING DOOR AND FRAME,
INCLUDING ALL CASINGS AND TRIMS.
9.92.03 PREP AND PAINT TWO (2) COATS EXISTING ROOF STRUCTURE IN ITS
ENTIRETY w/ DRYFALL PAINT.
9.92.04 PREP AND PAINT TWO (2) COATS EXISTING DOOR FRAME IN ITS
ENTIRETY.
10 SPECIALTIES
10.56 STORAGE ASSEMBLIES
10.56.01 PROVIDE AND INSTALL NEW FIVE (5) TIER, 72" LENGTH x 24" DEEP
SHELVING SYSTEM. PROVIDE WOOD BLOCKING IN WALL AS
REQUIRED FOR SECURE MOUNTING. BASIS OF DESIGN: E-Z
SHELVING SYSTEMS, INC. CANTILEVER METAL STORAGE SYSTEM, OR
EQUAL.
23.34 HVAC FANS
23.34.01 NEW HIGH VOLUME, LOW SPEED (HVLS) CEILING FAN MOUNTED
TO ROOF STRUCTURE, BY EC. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. COORDINATE REQUIRED FAN CLEARANCES
w/ ALL OTHER CEILING MOUNTED FIXTURES; SEE ELECTRICAL NOTES 1 & 2.
26 ELECTRICAL
26.50 LIGHTING
26.50.01 INSTALL NEW HIGH-BAY LINEAR LED LIGHT FIXTURES IN NEW
LOCATION AS SHOWN ON PLAN. SEE ELECTRICAL NOTE #2.
SCALE: 1/4" = 1'-0"1 INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"2 INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"3 INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"4 INTERIOR ELEVATION
SCALE: 3/4" = 1'-0"5 SHELVING DETAIL
W A
RE
H
O
US
E
RE
N O
V A
TIO
N
S
READING AREA
COMMUNITY COLLEGE
CONSTRUCTION DOCUMENTS
REVISION HISTORY
DETAILS
A-501
PROJ. MGR.: BRAD BLANKENBILLER
PROJECT #:
26-0014
PROFESSIONAL SEAL
1 2 6 8 P E N N A V E N U E W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 . 3 7 6 . 4 9 2 7 w w w . M G - A r c h i t e c t s . c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
SHEET TITLE:
DRAWN BY: EMG
CLIENT PROJ #: 26-27-001
SCOTT GRAHAM AIA, LEED AP+
SCOTTG@MG-ARCHITECTS.COM
RE
A
D
IN
G A
RE
A
C O
M M
UN
ITY
C O
LL
EG
E
SP
RU
C E
ST
RE
ET
R
EA
D
IN
G
, P A contact: DOLORES PETERSON, SENIOR VP
10 SOUTH SECOND STREET
READING, PA 19602
610.607.6265
DPETERSON@RACC.EDU
VERIFY SCALE
e-MAIL: BRADB@MG-ARCHITECTS.COM
RACC Warehouse.pln | P:\26-0014.0_RACC_Warehouse\1-Design\RACC Warehouse.pln | 7/7/2026 | 10:27 AM
A R C H I T E C T U R A L D E S I G N I N T E R I O R D E S I G N C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S H I S T O R I C P R E S E R V A T I O N
COPYRIGHT © 2026 ALL RIGHTS RESERVED. NEITHER ALL NOR
ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MG ARCHITECTS, LTD. THESE PLANS, DESIGNS AND SUBJECT
MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN
ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO
ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN
PERMISSION AND CONSENT OF MUHLENBERG GREENE
ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF SERVICE
AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MG ARCHITECTS, LTD.
45º 45º
45°
GUY WIRE
GUY WIRE
GRIPPLE
FINISH FLOOR
0'-0"
B.O. EXISTING ROOF
23'-6 1/2"
T.O. PLYWOOD SHEATHING
8'-0" A.F.F.
2.01.07 9.92.03
2.01.01
2.01.18
9.22.01
6.16.01
2.01.11
7.21.01
9.65.01
FACE OF EXISTING CORRUGATED
STEEL SIDING
9.22.03
9.22.03
9.22.03
9.29.02
9.22.04
FINISH FLOOR
0'-0"
B.O. EXISTING ROOF
23'-6 1/2"
2.01.10
2.01.17 7.21.03
9.65.01
7.21.01 2.01.05 9.92.03
2.01.17 7.21.03
2.01.10
RETURN WALL SURFACE
INTO JAMB AND SILL; TYPICAL
FOR ALL WINDOWS
RETURN WALL SURFACE
INTO JAMB AND SILL; TYPICAL
FOR ALL WINDOWS
T.O. PLYWOOD SHEATHING
8'-0" A.F.F.
6.16.01
9.29.02
RETURN WALL SURFACE
INTO JAMB AND SILL; TYPICAL
FOR ALL WINDOWS
RETURN WALL SURFACE
INTO FRAME HEAD; TYPICAL
FOR ALL WINDOWS
RETURN WALL SURFACE
INTO JAMB AND SILL; TYPICAL
FOR ALL WINDOWS
RETURN WALL SURFACE
INTO FRAME HEAD; TYPICAL
FOR ALL WINDOWS
DOOR SCHEDULE
DOOR
NUMBER
101.1
102.1
ROOM NAME
THEATRICAL STORAGE
ROOM
WAREHOUSE VESTIBULE
OPENING
WIDTH
5'-6"
6'-0"
OPENING
HEIGHT
6'-8"
7'-0"
HANDING
RHA
LRA
FRAME DATA
ELEVATION
EXISTING
F1
MATERIAL
EXISTING
HM
GLAZING
DOOR DATA
ELEVATION
F
F
THICKNESS
1 3/4"
1 3/4"
MATERIAL
STL
STL
GLAZING
THRESHOLD/
SADDLE
HEAD
6/A-501
JAMB
7/A-501
SILL
REMARKS
EXISTING FRAME; VERIFY DIMENSIONS IN FIELD.
ONE (1) 3'-0" PANEL, ONE (1) 2'-6" PANEL
INFILL HOST WALL AROUND FRAME AS REQUIRED
FINISH FLOOR
0'-0"
2"
SCHEDULED BASE
2.01.07 9.92.03
EXISTING WALL CONSTRUCTION
TO REMAIN
T.O. PLYWOOD SHEATHING
8'-0" A.F.F.
B.O. GIRT
11'-11 3/4" A.F.F.
B.O. EXISTING DECK
23'-6 1/2"
9.22.01
2.01.12
2.01.13
7.21.01
9.22.04
6.16.01
9.29.02
DOOR HARDWARE SCHEDULE
DOORS
101.1
102.1
LOCK/LATCH FUNCTION
PASSAGE w/ DOUBLE CYLINDER
STOREROOM
PREP
CYLINDER
HARDWARE OUTSIDE
LEVER
LEVER
HARDWARE INSIDE
LEVER
EXIT DEVICE, CONCEALED
VERT. RODS
HINGE
3 PAIR
3 PAIR
ELECTRIC LOCK
POSITION
SWITCH
CARD/KEY
FOB READER
CLOSER
SURFACE, PARALLEL ARM
STOP/BUMPER
WALL STOP
FLOOR STOP
KICK PLATE
48; x 2 LDW
GASKET
FLOOR
SWEEP
THRESHOLD
ACCESSORY
CONCEALED FLUSH BOLTS, TOP
& BOTTOM
FINISH
US32D
US32D
REMARKS
SEE NOTES 12, 13, 14, &17
SEE NOTES 12, 15, &16
DOOR FRAME MATERIAL LEGEND
HM HOLLOW METAL (STEEL)
ALUM.1 ALUMINUM BY STOREFRONT/CURTAINWALL MFR.
WD WOOD FRAME
INSUL INSULATED/THERMALLY BROKEN AT EXTERIOR LOCATIONS
EXIST EXISTING DOOR TO REMAIN
DOOR MATERIAL LEGEND
STL HOLLOW METAL (STEEL) DOOR
STL-INSUL. INSULATED CORE, STEEL DOOR
WD FLUSH WOOD DOOR
ALUM ALUMINUM-FRAMED…
This is the start of the file's text. The full file is on GovTribe.