1TX2620 - RLP Amendment 1.pdf

PDF 70 KB Posted

Attached to
1TX2620 RLP Amendment #1
Solicitation number
1TX2620_1
Issued by

About this file

This document is an Amendment to Request for Lease Proposal (RLP) No. 1TX2620 for a federal contract opportunity in San Antonio, TX. The amendment revises the space breakdown and requirements, including the ABOA square footage, HVAC requirements, and ceiling requirements for the office, light industrial, and warehouse space types. Specifically, the office space requires 9,000 ABOA SF with a complete acoustical ceiling system, the light industrial space requires 8,000 ABOA SF with a minimum 14' clear ceiling height and no acoustical ceiling requirement, and the warehouse space requires 7,000 ABOA SF with a minimum 20' clear ceiling height and no acoustical ceiling requirement. The federal agency involved is the General Services Administration (GSA) Public Buildings Service. The original RLP was issued on October 30, 2024.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA Public Buildings Service

US General Services Administration

Lessor______ Gov’t______

AMENDMENT NO. 1 to REQUEST FOR LEASE PROPOSAL (RLP)

RLP NO. 1TX2620

San Antonio, TX

November 5, 2024

The following amendment is hereby made to Request for Lease Proposal (RLP) 1TX2620, issued October 30, 2024:

1. Section 5.04 SPACE BREAKDOWN AND REQUIREMENTS of RLP No. 1TX2620, is hereby deleted in its entirety and replaced with the following:

The table below provides a breakdown of the approximate space requirements, types and shell requirements for each type of space.

Space Type ABOA SF HVAC Requirements Ceiling Requirements Office 9,000 Office Area Complete acoustical ceiling system (Lease Section

3.20) Light Industrial 8,000 Office Area The ceiling must be a minimum of 14’ clear.

Acoustical ceiling system not required.

Warehouse 7,000 Warehouse or Garage Area The ceiling must be a minimum of 20’ clear.

Acoustical ceiling system not required.

2. Section 7.07 SPACE BREAKDOWN AND REQUIREMENTS of Exhibit A: Lease No. GS-07P-LTX01159 of

RLP No. 1TX2620, is hereby deleted in its entirety and replaced with the following:

The table below provides a breakdown of the approximate space requirements, types and shell requirements for each type of space.

Space Type ABOA SF HVAC Requirements Ceiling Requirements Office 9,000 Office Area Complete acoustical ceiling system (Lease Section

3.20) Light Industrial 8,000 Office Area The ceiling must be a minimum of 14’ clear.

Acoustical ceiling system not required.

Warehouse 7,000 Warehouse or Garage Area The ceiling must be a minimum of 20’ clear.

Acoustical ceiling system not required.

FOR THE LESSOR: FOR THE GOVERNMENT:

Name: Name:

Title: Title: Lease Contracting Officer Entity Name: General Services Administration, Public Building Service Date: Date:

File details come from the government source that posted it. Updated .