1B20 Proofer Roll-In.docx
DOCX document 53 KB Posted
- Attached to
- Ovens and Proofers Federal contract opportunity
- Solicitation number
- HDEC0418R0050
- Issued by
- Defense Commissary Agency
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 0418R0050 Amended SOL Summary of Changes.pdf | ||
| 0418R0050 Amended SOL.pdf | ||
| Revised 1B15 Oven Mini-Rotary with Proofer.docx | DOCX document | |
| SOW for Site Survey.pdf | ||
| 1B15 Oven Mini-Rotary with Proofer.docx | DOCX document | |
| Released SOL 0418R0050.pdf | ||
| 1B13-A Oven Roll-in Double Rack Electric.docx | DOCX document | |
| 1B12-A Oven Roll-in Single Rack Electric.docx | DOCX document | |
| 1B12-B Oven Roll-in Single Rack Gas.docx | DOCX document | |
| 1B13-B Oven Roll-in Double Rack Gas.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INITIATED
11/29/17
CED
BAKERY
DEPARTMENT
Minimal Acceptable Standards
REVISION
xx/xx/xx
| 1B20 | |
| Proofer, roll-in | |
| PAGE 3 of 3 |
Purpose of this Equipment: To provide optimum atmosphere (temperature and humidity) for proofer stage of production of bakery products.
1 Federal Supply Class: 7310
2 General Operating Specifications:
2.1 Dimensions:
2.1.1 1B20-A (1 door): Not to exceed 100 inches high, 39 inches wide, 44 inches deep.
2.1.2 1B20-B (2 doors): Not to exceed 100 inches high, 79 inches wide, 44 inches deep.
2.2 Salient Characteristics that shall be provided:
2.2.1 Stainless steel construction interior and exterior (aluminum top acceptable).
2.2.2 One rack per door only.
2.2.3 Magnetic door gaskets.
2.2.4 Insulated.
2.2.5 Interior bumpers.
2.2.6 Electronic controls for adjusting temperature and humidity.
2.2.7 Interior Light.
2.2.8 Reversible door.
2.2.9 Must be flush and level with floor.
2.2.10 Water inlet and drain connections.
2.3 Industry Standards / Requirement(s):
2.3.1 Industry Standards: Underwriters Laboratory (UL) listed and National Sanitation Foundation (NSF) certification, or approved equivalent. Conformité Européene
2.3.2 Warranty period shall be for (1) year from date of delivery against defective material and workmanship and shall include parts, service and labor.
2.4 Information Technology requirements: N / A
2.5 Color Requirement(s): N / A
3 Electrical Requirements:
3.1 _____Standard U.S.A electrical specifications: 208 V/ 60 HZ/ 3 PH and
120 V/ 60 HZ/ 1 PH
3.2 _____U.S.A. electrical specifications: 240 V/ 60 HZ/ 3 PH and
120 V/ 60 HZ/ 1 PH
3.3 _____U.S.A. electrical specifications: 480 V/ 60 HZ/ 3 PH and
120 V/ 60 HZ/ 1 PH
3.4 _____ Pacific Theater stores 208/230 V / 50 HZ / 1 PH (Applies to these stores only: Atsugi, Misawa, Sagami, Sagamihara, Yokosuka, Yokota, Camp Zama, and Kanto Plains CDC. All other stores are standard U.S.A. 60 cycle voltages.)
3.5 NOTE: the operating range for 120 volts is 110 to 120 volts; the operating range for 220 volts is 208 to 230 volts.
Standard Contractor Requirements:
3.6 Must be shipped split, ready to assemble, able to fit through a 36 inch opening, make utility connections, and use.
3.7 De-installation of old equipment is required.
3.8 This equipment requires disposal: Contractor to remove from commissary and dispose.
3.9 Installation required by an authorized service technician.
3.10 Operational testing is required.
3.11 Startup assistance required.
3.12 Provide familiarization training.
3.13 Information to be provided by the Contractor to the commissary at the time of delivery:
3.13.1 Point of Contact for Service
3.13.2 Installation and Operating Instructions
3.13.3 Parts List
3.14 Maintenance Sustainability Requirements: Continued parts support is required for the projected life cycle of the equipment plus 5 years.
Special Coordinating / Safety Instructions: De-installation of existing proofer and removal from premises for disposal is requested.
STORE ORDER REQUEST
STORE NAME: __________________________ DODAAC: ____________________
SINGLE OR DOUBLE: _________ QUANTITY: _______
1. DOOR: RIGHT HAND____________________, LEFT HAND________________
1. DRAIN LOCATED FRONT________________, REAR_______________________
1. ADDITIONAL RACKS: ___________________
1. CURRENT PROOFER TO BE REMOVED:
MANUFACTURER______________________ BARCODE____________________
SERIAL NUMBER_______________________ MFR YEAR___________________
FY16r.05 image1.jpeg image2.jpeg
File details come from the government source that posted it. Updated .