da2_5100_ins_opls06fw May 2006 Rev. E 40-5100
Installation and Operation Manual
Including 5100 Control Panel, 5105-E Keypad and 5100 Wireless Components
See Also: Assembly Instructions and Quick Start Guide
AES Corporation 285 Newbury Street Peabody, Massachusetts 01960-1315 USA
Tel (978) 535-7310 Fax (978) 535-7313
Copyright 2006
AES 5100
Control/Communicator
Installation Manual
Table of Contents
AES Corporation
USA (978) 535-7310
General Description
Ordering Information
Feature Definitions............................................................................................ 4-7
Programming the 5105-E LCD Keypads
Using the Function Menu
Programming the 5100
Types of Programming Data
Enrolling the Modules & Keypads
Quick Start Installations
Communicator Formats
Reporting Events to Phone #1, #2, & #3 ..................................................... 16-21
Default Zone Types
Zone Doubling
Programming the Outputs ........................................................................... 27-28
Programming Worksheets ........................................................................... 41-54
SIA and Contact ID Formats ......................................................................... 55-56
Expander Trouble Reporting Information
Wiring Diagram
Terminal Description
Telephone Interface Information
Underwriters Laboratories Information
Specifications & Warranty
General Description
The 5100 from AES Corporation represents a new approach to security systems design. AES has developed a flexible, durable, and user-friendly control. Featuring sophisticated software, which allows up to 99 users to interface with 48 zones, 8 partitions, and a host of integrated fire, access, verification, and input/output modules, all reported with the most comprehensive and fast SIA and Contact ID formats. The 5100 design allows a fully loaded system to be housed in one single metal enclosure, establishing, a logical solution and design response to modular systems. Up to 32 modules can be added to expand the capabilities of the 5100.
ORDERING INFORMATION
AES PART # DESCRIPTION
Control Panels
5100 Control Panel, Including 5105-E LCD Keypad, 52-5100-R08 8 Zone Wireless Receiver, 725
110/220 Power Supply and Locking steel case.
5100-EX Control Panel, Including 5105-E LCD Keypad, 52-5100-R48 48 Zone Wireless Receiver, 725 110/220 Power Supply and Locking steel case.
Standard Accessories
5104 Single 12-Volt Relay Module
5105-E Alphanumeric LCD Keypad
5110 Keyfob / Keychain Touchpad Transmitter
5115 Pendant Panic Transmitter
5120 Door / Window Transmitter
5135 Smoke Detector Transmitter
5155 PIR Motion Detector Transmitter
5182 AES IntelliNet Radio interface
02-1008 3.3K (3300 Ohm) 1/2W 5% Resistor
02-1005 680 (680 Ohm) 1/2W 5% Resistor
Replacement Parts – Special Order
52-5100-R08 8 Zone Wireless Expansion Module
52-5100-R48 48 Zone Wireless Expansion Module
56-5100 5100 Control Only Including Locking steel case
725 18 VDC 2A Power Supply, 110/220v, 50/60 Hz.
Other Accessories – Special Order
5101 24 Zone LED Keypad (not available at this time)
5100-1200 Hayes Smart Modem 1200 (Pg. 6)
Call Seven Relay Module Call Eight Output Module Call Fire Supervision Module Call 16 Zone Expander Module Call Zone Doubling Kit (Includes 100 3.74k and 100 6.98k resistors) Call Smart Power Supply and Buss Extender Call Two-Way Listen-In Module Call Two-Way Voice Module
FEATURE DEFINITIONS
Abort - If enabled, the 5100 will wait the programmed number of seconds in location 40 prior to sending an alarm.
During this delay time, the “Cancel” LED will flash. To abort the report, type in a code and press the [Cancel] key. The LED will extinguish. If the report is not aborted within the allotted time, the LED will extinguish when the report is sent.
“Dialer Delay” must be enabled in the “Characteristic Select” of locations 110-149.
(See locations 40 and 110-149, pages 26 and 37)
AC Fail / Low Battery Report/Warning- The 5100 can be programmed to report AC failure and/or Low Battery conditions to the central station. It can also be programmed to sound the keypad immediately upon detection of the condition. The AC failure report/warning can be delayed. (See locations 37 and 39, page 25)
AC Power / Low Battery Sounder Alert- If enabled, the 5100 will beep the keypad sounder upon arming or disarming if the AC power is missing or a low battery has been detected. (See location 23, page 21)
Arm / Disarm Codes - The 5100 can have 99 four-digit codes or 66 six-digit codes to arm/disarm the control. All codes must have the same number of digits. The factory default for User #1 is [1]-[2]-[3]-[4] when using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. This code can then be used to enter the new arm/disarm codes.
(See location 41, page 26)
Automatic Arming - If programmed, the 5100 will Auto Arm at a specified time. At this time, the keypad will beep for 50 seconds before the panel arms. The arming process will be stopped if a code is entered on the keypad. The 5100 will attempt to arm after every 45 minutes of inactivity until the next “opening” time (loc. 52), or until the system is armed. The 45-minute timer will be extended when there is activity in the building causing the “Ready” LED to turn off and on. If closing reports are sent, the user code will be 97. (See locations 23, and 52-55, pages 21 and 29) NOTE: For UL installations, this feature shall be disabled.
Auto Cancel / Abort - If enabled, the Cancel and/or Abort features will be automatic (pressing the [Cancel] button is not required). The Cancel and Abort features, in locations 23 and 40 respectively, must be enabled to permit this Auto feature to work. For proper operation of these features, “Dialer Delay” must be enabled in the “Characteristic Select” of locations 110-149 Zone Types. (See location 41, page 26)
Automatic Bypass / Instant Arming - When enabled, the control panel can automatically bypass interior follower zones if an exit is not detected during the exit delay time. Entry delay zones can also be made instant.
(See location 23, segments 1 and 3, page 21)
Auto Test- This feature will cause the panel to call the central station to report a communicator test at a specified interval. (See location 51, page 29)
Auxiliary Outputs- The 5100 has four programmable outputs that can be used to activate relays, LED’s, etc.
(See the terminal description on page 59 and locations 45-50, pages 27)
Auxiliary Power Over current- The 5100 will illuminate the "Service" display on the keypad whenever too much current is drawn from any device powered by the system. This condition can be reported to the central station.
(See location 37, page 25)
Box Tamper- The 5100 has a two terminal input on the circuit board for a normally closed tamper switch (see terminal drawing). The Box Tamper can be programmed to report and/or sound the siren and/or the keypad. These terminals can be enabled or disabled in programming. (See locations 37 and 39, page 25)
Built In Siren Driver - The 5100 has a built-in 112db-siren driver. When desired, this built-in driver can be easily converted to a 1-amp voltage output through programming. (See location 37, page 25)
Bypass Toggle- This feature will enable the end user to toggle (turn on or off) the bypass of an interior zone with the system armed by pressing the [Bypass] key. (See location 23, page 21)
Call Back- When enabled, the control will use the call back phone number to call the download computer before beginning a download. (See location 21, page 20)
Cancel - If enabled, the 5100 will send a “Cancel” report if when the system is disarmed and the [Cancel] button is pressed within 5 minutes of an alarm. Once the [Cancel] key is pressed, the “Cancel” LED will illuminate until the central station acknowledges the “Cancel” report. “Dialer Delay” must be enabled in the “Characteristic Select” of locations 110-149. (See location 23, page 21)
Code Required Options- The 5100 can be programmed to require a code for bypassing zones and/or initiating a download using the []-[9]-[8] or []-[9]-[9] function. (See locations 23 and 41, pages 21 and 26)
Communication Formats- The 5100 can report in multiple formats. It is recommended that you use Contact ID or SIA formats if possible. If you wish to report to a pager or in a 4+2 format to a central station, you must program each code to be reported. (See locations 56-83 and 111-149, pages 30-33 and 37-40)
Cross Zoning - This feature requires two or more trips on a zone or zones programmed as "cross zones" within a specified time before reporting an alarm. During the time between trips, the 5100 can be programmed to sound the keypad and/or the siren. The 5100 can also be programmed to report an alarm after two or more trips on the same zone. (See locations 37, 39, 40 and 110-149, pages 25 - 26, 37 - 40)
Dual / Split / Multiple Reports - The 5100 can send communication reports to three different phone numbers for dual, split or multiple reports selectable by event or partition. (See locations 4, 10, and 16, pages 16-19)
Duress Code- If a duress code is programmed the 5100 will send a duress signal whenever the panel is armed or disarmed with this code. If open/close reports are sent, the user code will be 254. (See location 44, page 27)
Dynamic Battery Test - The 5100 can be programmed to perform a Dynamic Battery Test for a selected duration the first time the panel is armed or disarmed every day, as well as by pressing [][4][4] Test Function. If the panel is not armed or disarmed during the day, it will perform the test at midnight. The 5100 can also be programmed to perform a missing battery test every 12 seconds. (See locations 37 and 40, pages 25 and 26)
Entry-Guard - This unique low level arming mode has been developed to reduce the most common source of false alarms. When armed with the “Instant” LED on, the opening of any zones designated as “Entry Guard zone” will initiate the keypad sounder and start the entry delay before creating an alarm. All other zones will function as normal.
This arming mode will encourage system owners to use their system more frequently when the premises are occupied.
(See locations 111-149, pages 37-40) NOTE: For UL installations, this feature shall be disabled.
Exit Error - If enabled, the 5100 will send an “Exit Error Report” if an entry/exit zone is faulted at the instant the exit delay expires. This report will be sent along with the user number that armed the system, if the panel is not disarmed before the entry delay expires. The alarm report will also be sent. Even if this feature is not enabled, the siren will sound if any entry/exit zone is faulted at the instant the exit delay expires. (See location 23, page 21)
Expander Trouble - The 5100 will report expander trouble to the central station if enabled. This condition will illuminate the “Service” display on the keypad even if not reported. NOTE: The keypads are considered expanders.
The number of the expansion devices reported can be found on page 53. (See location 37, page 25)
Fail to Communicate- The 5100 will illuminate the “Service” display if a report fails to reach the central station. If enabled, when the next report is successfully communicated, a Fail to Communicate code will be reported.
(See location 37, page 25)
Fire Alarm Verification - When enabled, the 5100 will verify a Fire alarm by requiring more than one trip on a smoke detector within a specified time before creating an alarm. (See location 40, page 26) This feature is not approved for residential use in California.
Force Arming - When enabled, the 5100 can be Force Armed with zones violated. Under this condition, if a force armable zone is not secure, the “Ready” LED will flash. At the end of the exit delay, these zones will become bypassed. If these zones become secured any time during the arming cycle, they will be un-bypassed and active in the system. If “Bypass Report” is enabled, the force arming zones can be programmed to report bypass when they are Force Armed (default), or to not report bypass even if “Bypass Report” is enabled. (See locations 37, and 111-149, pages 25 & 37-40) NOTE: For UL installations, this feature shall be disabled.
Ground Fault- If the Fire Supervision Module is used, a fault of the earth ground can be reported to the central station.
If it is not reported, this condition will illuminate the “Service” display on the keypad. (See location 37, page 25)
Group Bypass - A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]- [Bypass] prior to arming. (See locations 111-149, pages 37-40) NOTE: For UL installations, this feature shall be disabled.
Immediate Restore By Zone - The 5100 can be programmed to send alarm and restore reports as soon as they occur, or wait until the siren time has expired. (See location 37, page 25)
Internal Event Log - Up to 185 events can be stored in memory along with the date and time of the event. These events can later be viewed through downloading. All reportable events report to the log.
Keypad Activated Panics- The 5100 has three keypad activated panics that will send reports to the central station:
Auxiliary 1 (Fire), Auxiliary 2 (Medical), and Keypad Panic. Auxiliary 1 will activate the steady (Fire) siren, Auxiliary 2 will sound the keypad, and the Keypad Panic can be programmed to be silent or audible (sound siren).
(See location 23, page 21)
Keypad Sounder Control - The 5100 can be programmed to sound the keypad sounder for certain events (See location 39, page 25)
Keypad Tamper - If enabled, the 5100 will disable the keypad for 60 seconds and communicate a tamper signal to the central station if 30 keypresses are entered without producing a valid code. (See location 23, page 21)
1205 Keyswitch Arm/Disarm - Any zone on the 5100 can be programmed as a keyswitch zone. If this is done, a momentary short on this zone will arm/disarm the control. If opening/closing reports are sent, the user code will be 99.
(See "Default Zone Types", page 22)
LED Extinguish - This feature will extinguish all LED’s on the keypad, except the “Power” LED, after 60 seconds without a keypress. Pressing any numeric key will illuminate all LED’s. (See location 23, page 21)
Local Programming Lockout- This feature will disable programming of all locations or specified locations from the keypad. (See location 21, page 20)
Log Full Report - A report can be sent to the central station when the event log is full. (See location 37, page 25)
Lost Clock Service Light - The 5100 can be programmed to illuminate the “Service” display when the internal clock has an invalid time due to power loss. (See location 37, page 25)
Manual Test - The 5100 can be programmed to perform a bell and/or communicator test when []-[4][4] is entered while the system is in the disarmed state. (See location 37, page 25)
On Board Zone Disable - The eight hardwired zones on the 5100 panel can be disabled in order to have a completely wireless alarm system. (See location 37, page 25)
Partitions - The 5100 can be partitioned into a maximum of eight separate systems with distinct reporting codes, user codes, and operating features for each system. (See locations 26 - 36, pages 23 - 24)
Program Code - The factory default for the “Go To Program” code is [9]-[7]-[1]-[3] when using a 4-digit code or, if the 6-digit option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code can also be used as an Arm/Disarm code.
If used as an Arm/Disarm code, and open/close reports are sent, the user code will be 255. (See location 43, page 26)
Quick Arm Feature - The 5100 has a one-button “Quick Arm” feature, which can be used to arm the system by pressing the [Exit] key or the [Stay] key on the keypad. If closing reports are sent, the user code will be 98.
(See location 23, page 21)
Recent Closing - If enabled, the 5100 will send a “Recent Closing Report” to the central station if an alarm occurs within 5 minutes after the panel is armed. The user number that armed the system will also be sent. (See location 23, page 21)
Re-exit - The 5100 has the ability to restart the exit delay for a quick exit without disarming the system by pressing the [Exit] key while the system is armed. (See location 23, page 21)
Shutdown - This mode will cause the keypads to turn off all LED’s, except the “Power” LED, and not accept keypresses. (See location 21, page 20)
Siren Blast For Arming –The 5100 can be programmed to give a one second siren blast when the panel is armed, at the end of the exit delay, or when the central station receiver acknowledges the closing report. It can also give one blast for wireless or remote (key-switch) arming and two blasts for wireless or remote disarming. (See location 37, page 25)
Siren Supervision - The 5100 has a “Siren Supervision” circuit that will constantly monitor the siren on the 5100 and can be programmed to report if the wires are cut. (See location 37, page 25)
Silent Exit Option - The exit delay can be silenced by pressing []-[Exit] before arming the control panel or when using the re-exit feature. The exit delay can also be silenced permanently in all partitions. (See location 37, page 25)
Start/End Programming and End Downloading - A report can be sent when local programming is started and ended. A report can also be sent when a download session ends. (See location 37, page 25)
Swinger Shutdown - This feature allows a zone or zones to be automatically bypassed after a specified number of alarms. If immediate restore is enabled in location 37, the alarms (and restores, if enabled) will be sent as they occur.
If immediate restore is not enabled, a second or subsequent alarm will not be sent until the siren times out. (See location 37 and 38, page 25) NOTE: For UL installations, this feature shall be disabled.
Telephone Line Monitor - The 5100 has a Telephone Line Monitor that monitors the voltage and current of the telephone line for a detection of a faulted phone line. This condition can also be reported to the central station. If the report is enabled, only the Telephone Line Restore will be reported unless the 5182 IntelliNet Interface or Fire Supervision Module is being used. (See locations 37, 39, and 40, pages 25-26)
Temporal Siren Disable - If disabled, the Fire Siren will be steady and Fire Voltage Out will be the same as Burglary (continuous). Otherwise, the Fire Siren will be temporal. (See location 37, page 25) NOTE: For UL installations, do NOT disable.
Tone Sniff Answering Machine Defeat - If enabled, only one call is required to defeat the answering machine. To use this feature you must have a Hayes 1200 Smart Modem or an AES 5100-1200 module. From the computer, call the panel as normal. When the answering machine answers, the panel will hear the tones from the modem and seize the phone line for a download. (See location 21, page 20)
Two Call Answering Machine Defeat - If enabled, to defeat an answering machine, two telephone calls must be made to the premises. On the first call, let the phone ring one or two times. The control panel will detect these rings and start a 45-second timer, during which, the control panel will answer the next call on the first ring. This is not recommended for commercial applications. (See location 21, page 20)
Walk-Test Mode - If enabled, entering [] [Chime] followed by a user code will allow a walk-through zone test where all zones become silent and local (non-reporting). During this test the chime light will flash on the LED keypad. Each time a zone is faulted, the zone light on the LED keypad will illuminate and the chime will sound. The number of the faulted zone(s) will be displayed on the LCD keypad. It will also be entered into alarm memory and the internal log. To exit at any time during this mode, enter a user code. Otherwise the “Walk-Test Mode” will automatically exit after 15 minutes. (See location 41, page 26)
Wireless Sensor Missing/Low Battery - The 5100 will send a report to the central station when a wireless sensor has detected a low battery or has not reported to the receiver. The “Service” display will illuminate when either condition exists. (See location 37, page 25)
Zone Bypassed Sounder Alert - If this feature is enabled, the 5100 will beep the keypad sounder upon arming if a zone is bypassed. (See location 23, page 21)
Zone Doubling - This feature allows you to use the eight zones on the panel as sixteen normally closed zones. When this feature is used zone eight cannot be a two-wire smoke zone, and European double E.O.L. configuration cannot be used on the first sixteen zones. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 48. If one of the sixteen zones must be a fire zone, it must be one of Zones 1 to 8. The corresponding upper zone will become unavailable. For example, if Zone 6 is a fire zone, then Zone 14 will not be available. (See location 37, page 25)
Zone Types (Configurations) - The 5100 has 20 programmable Zone Types that determine how each zone will function and report. The default Zone Types are listed on page 18. (See locations 111-149, pages 37-40)
PROGRAMMING THE 5105-E LCD KEYPADS
Refer to separate AES 5105-E LCD Installation Manual for complete LCD keypad instructions including setting the time, date and custom messages in the keypad.
This section describes how to program the address and partition of each keypad as well as the some of the options that are available. The address of the keypad is important because this is how the panel supervises the keypads.
The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory default for the “Go To Program” code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit code. The factory default is a 4-digit code.
USING THE FUNCTION MENU
The 5105-E keypad has a built in function menu that allows you to scroll through available function and select the one you want. This is easier than having to look up or memorize the function number. Below are instructions on using the Function Menu:
[] Accesses the Function menu.
Tip: If you know the function #s, The display will begin scrolling though available functions.
simply press [ function #].
[]-[Function #] Press the number(s) listed for that function.
[] Displays the next menu item.
[#] Exits the Function Menu.
These are samples of the displays that will scroll automatically in the Function Menu.
Below is a list of available functions accessible through the menu or directly by entering the function number.
[]-[9]-[1] Adjusting the View / Brightness of LCD
1) Enter []-[9]-[1] The LCD Screen will prompt for the “Go To Program” code.
2) Enter [master code] The LCD will now prompt you to raise or lower the viewing angle. Using the scroll keys to the right of the LCD, you can raise or lower the viewing angle of the text
3) To advance to the Brightness option, press [].
The LCD will prompt you to brighten or dim the LCD lighting. Use the scroll keys again to adjust to desired brightness. When completed, exit by pressing []
[]-[9]-[2] Custom Messages
IMPORTANT NOTES
1) When using standard 5100 keypad(s) and 5100-E keypad(s) in the same system, it is necessary to use a
NON-“E” keypad to program the custom messages. The NON-“E” keypads can be identified by the fact that they do not display a menu when is pressed.
2) The messages (custom, zone, and shutdown) are transferred to other LCD keypads after this mode is exited.
All keypads must be addressed and enrolled for this to occur.
3) Use the []-[9]-[4] function to set the keypad numbers prior to programming custom messages.
4) If a keypad is added after messages are programmed, you should either program ALL messages in it, or enter custom message programming on an existing keypad and make changes. This is to prevent accidentally overwriting existing messages. Refer to []-[9]-[3] option to prevent overwriting the custom message only.
Select an Option Press for help
Select an Option = Zone Review
[]-[9]-[2] Custom Messages (continued)
1) Enter []-[9]-[2] Prompts to “Please Enter Your Code".
2) Enter []-[program code] The LCD will now prompt you to enter message number followed by #.
Zones 1 through 192 custom messages are message numbers 1-192.
Message 193 - Custom message top line.
Message 194 - Custom message bottom line.
Message 195 - Shutdown message top line.
Message 196 - Shutdown message bottom line.
3) Enter [message number] # The LCD will display the zone number on the top line and the description will be on the bottom line.
Use the instructions on page 12 for editing character data.
4) Enter [EXIT] Any changes will automatically be copied to all other LCD keypads in the system.
If you desire an LCD keypad to have a different custom message, you must enable Custom Message Lock under the []-[9]-[3] function (below).
[]-[4]-[9] Custom messages in language 2 (Spanish)
1) Enter []-[4]-[9] Keypad is now toggled to the second language.
[]-[9]-[3] Set keypad options
1) Enter []-[9]-[3] The LCD Screen will prompt for the “Go To Program” code.
2) Enter [program code] The LCD will now prompt you through the options listed on the following chart. The current state of the option will be shown in the lower right corner of the display. Press [] to exit the current state unchanged. Otherwise, follow the directions on the bottom line to select the desired option. When finished, press [] to move to the next option.
Option
Keypad Features
NOT USED. DO NOT PROGRAM THIS AT ALL!
SILENT KEYPAD? Enable Silent Keypad Option. If enabled, only the entry/exit and sounder chime are silenced.
DING DONG CHIME? Enable Ding Dong Sound for Chime. If off, chime will be a single tone (see, location 40, page 22)
5 SEC. SILENCE? Enable Keypress Silence Option. Silences the pulsing keypad sounder for 5 seconds when a key is pressed.
ARMED ZONE INFO? Enable Armed Zone Information. If on, the LCD keypad will display faulted or bypassed zone information when the system is armed.
BEEP ON PANICS? Enable Panic, Fire, Medical Beeptone. Will sound a short beep to verify that the keypress was accepted.
DISABLE SERVICE? Suppresses the “Service” Message. This will not allow the “Service” Message to be displayed for any reason. If there is a system trouble, []-[2] will still show the “Service” menu.
MASTER KEYPAD? Enable Multi-partition Mode
CUSTOM MESSAGE? Enable Custom Message Display
CLOCK? Enable Clock Display
CUSTOM MSG. LOCK? Enable Custom Message Lock. Prevents over-writing the custom message during keypad copy.
SELECT AN OPTION: Programs special characteristics.
1=Display “Press For Help”
2=Disable LED Extinguish on this keypad
3=On if PIN should be hidden when programming
4=On suppresses beeps when an RF transmission is lost
5-8=RESERVED (Do not program!)
[]-[9]-[4] Set Keypad Number and Partition
1) Enter []-[9]-[4] The LCD Screen will prompt for the “Go To Program” code.
2 Enter [program code] The LCD will now prompt you for the keypad number followed by []. The current keypad number will be displayed in the lower right hand corner.
3) Enter the keypad number followed by [] The LCD will now prompt you for the partition number followed by []. The current partition will be displayed in the lower right hand corner.
4) Enter the partition number for the keypad The keypad will automatically exit this mode now.
[]-[9]-[0] Reading the Event Log
1) Enter []-[9]-[0] Prompts to “Please Enter Your Code".
2) Enter [master code] Shows the most recent event.
3) Enter Views the events from newest to oldest.
4) Enter Views the events from oldest to newest.
The following are possible log messages.
TXlobat Transmitter Low Battery - The transmitter has a low battery.
ZN Lost Zone Lost - A wireless or multiplexed zone device is not reporting to the control.
Duress Duress - The control has been armed or disarmed with a Duress code.
Man Fire Manual Fire - Keypad “Fire” has been activated.
Aux 2 Auxiliary 2 - Keypad “Medical” has been activated.
Panic Panic - Keypad “Panic” has been activated.
KP Tamper Keypad Tamper - The keypad tamper has been activated.
BoxTamp Box Tamper - The box tamper circuit has been activated.
AC Fail AC Fail - AC failure has been detected.
OverCur Over Current - A short circuit of a power supply has occurred.
Srn Tamp Siren Tamper - A siren or speaker tamper has been detected.
Tel Flt Telephone Fault - A telephone fault or tamper has been detected.
Exp Trb Expansion Trouble - An expansion device or keypad is not reporting to the control.
Log Full Log Full - The event log is full.
Open Open - Reports user number, date, time and partition of opening.
Close Close - Reports user number, date, time and partition of closing.
Exit Err Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Rec Close Recent Close - An alarm occurred within 5 minutes after the control was armed.
Autotest Auto Test - Sending a communicator test at a specified interval.
Start Prog Start Programming - Local programming is started.
End Prog End Programming - Local programming is ended.
Start Dnld Start Download - Download session is started.
End Dnld End Download - Download session is ended.
Cancel Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm.
Gnd Flt Ground Fault - A short to ground has been detected.
Man Test Manual Test - Bell and/or communicator test while system is in disarmed condition.
Re-exit Re-Exit - The exit delay has been re-started without disarming the system.
Output Trip Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost Data Lost - Communication of a signal has failed (log only event).
Walk-test Walk-Test - A zone “Walk-Test” mode has been activated.
End Test End Test - Test has been ended.
Cross-Trip Cross Trip - The first zone of a cross zone has been tripped (log only event).
Expansion Event An expansion module has created an undefined event.
Partial Arm Partial Arm - Reports a closing in the stay mode.
Listen In Listen In - A listen in function has been activated.
Service Start Service Start - Technician is on site.
Service End Service End - Technician is off site.
Code Entry Code Entry - A code has been entered.
First Open First Open - Reports when the first partition is disarmed.
possible log messages (continued)
Last Close Last Close - Reports when the last partition is armed.
Sprnklr Sprinkler - Instant sprinkler supervisory report
Clock Set Clock Set - Clock has been reset.
RF Jammed RF Jammed - A wireless expansion module is jammed
CleanMe Clean Me - A smoke detector requires cleaning.
[]-[9]-[5] Set Elapsed Time in Minutes Since Last Autotest
1) Enter []-[9]-[5] Prompts for a code.
2) Enter [program code] Displays the elapsed time screen.
3) Enter [0]-[0]-[5] 100's digit] [10's digit] [1's digit] “005” is an example only.
4) Enter [#] Saves and exits
[]-[9]-[7] Set System Time and Date
1) Enter []-[9]-[7] Prompts to “Please Enter Your Code".
2) Enter [master code] Displays date and time with the current hour flashing.
3) Enter or Scroll to select the proper hour.
4) Enter Advances to the selection for the minutes.
Repeat the last two steps until the entire time and date is set.
[]-[0] Adjust the Keypad Tones
1) Enter []-[0] Prompts to use the scroll keys (right of the display) to raise or lower the tone.
2) Enter to lower the tone The keypad will emit a continuous tone to allow or Enter to raise the tone you to hear the current selection.
3) Enter [#] Saves the tone and exits the mode.
[] View Zone Status
1) Enter []- Displays the zone status.
2) Enter or Displays the list of ALL zones in sequential order by zone number.
3) Enter [#] Exits the mode
[]-[3] View Alarm Memory
1) Enter []- Displays the zone status.
2) Enter or Displays the alarm memory in sequential order by zone number.
3) Enter [#] Exits the mode
[]-[4]-[4] Test Function
Enter []-[4]-[4] Test will be performed as programmed.
If the siren test is performed, enter a user code to silence the siren.
[]-[4]-[5] Display Test Function
Enter []-[4]-[5] All display pixels and LED indicators will flash.
Press any key to end test.
[]-[5] CHANGING USER CODES
Note: For partitioned systems, someone changing the code of another person must have access to all or more partitions than the user being changed.
1) Enter []-[5]
The LCD Screen will prompt for a code.
2) Enter [master code]
The LCD Screen will prompt for a user Number.
3) Enter the 2 digit user number (always 2 digits, i.e. "03" for user 3)
The LCD screen will prompt for a new code.
4) Enter the new user code designated for that individual. The sounder will beep 3 times if it rejects the code.
5) If another user code needs to be programmed, return to step 3.
6) To exit Code Programming, press [#] while the LCD screen is prompting for a new user number.
[]-[6] ASSIGNING AUTHORITY LEVEL
Note: You must have authority to the partition you wish to add or remove from another person’s authority.
1) Enter []-[6]
The LCD Screen will prompt for a code.
2) Enter [master code]
The LCD Screen will prompt for a user Number.
3) Enter the 2 digit user number (always 2 digits, i.e. "03" for user 3)
The LCD screen will prompt for a new code. The LCD will now prompt you for the first in the following list of attributes.
PROMPTS
If Prompt #1 ("Outputs used?") is answered NO, the LCD will display the four messages below.
If Prompt #1 ("Outputs used?") is answered YES, the LCD will display the four messages below.
(#1) Outputs used?
Open / Close Rprt?
Bypass enable?
Arm / Disarm?
Master code?
Output 4 enable?
Sched arm only?
Output 3 enable?
Arm only?
Output 2 enable?
Reserved
Output 1 enable?
4) Enter a partition number. Note: The default allows access to all partitions. The first keypress will remove access to the partition. To reestablish access, press the partition number again. When completed, press [].
The LCD Screen will prompt you for the next user code.
5) If another user code needs to be programmed, return to Step 3.
6) To exit this feature, press [#].
NOTE: Any master arm/disarm code can add or change a user code if the master code has access to the same partitions as the code being added/changed. Consequently, when programming the user codes for a partitioned system, leave at least one code (can be “go to program code” if enabled in location 43) access to all partitions or you will not be able to add new users. If you desire the end user to be able to add new codes, you must remove the partition authority from all blank codes.
The system must be disarmed to perform these functions.
[]-[7] Reset Function
[]-[7] The smoke detectors, zone troubles, and zone tampers have now been reset.
If the keypad begins beeping, the reset did not execute properly. Enter your code to silence the keypad.
Wait a few minutes and repeat step to attempt another reset.
[]-[9]-[8]
Pressing []-[9]-[8] while the system is disarmed will cause the control to do a callback for a download. NOTE:
A valid user code may be required after []-[9]-[8] if enabled in location 41, page 22.
[]-[9]-[9]
Pressing []-[9]-[9] while the system is disarmed will cause the control panel to seize the phone line for a download. NOTE: A valid user code may be required after []-[9]-[9] if enabled in location 41.
PROGRAMMING THE 5100 CONTROL
ENTERING THE PROGRAM MODE: To enter the Program Mode, press []-[8]. At this time, the LCD screen will prompt you for the programming code. Next, enter the "Go To Program Code" (FACTORY DEFAULT IS [9]-[7]-[1]-
[3]). If the "Go To Program Code" is valid, the LCD screen will prompt you for the device address you wish to program.
You are now in the Program Mode and ready to select the module to program.
SELECTING THE MODULE TO PROGRAM: Since all modules connected to the 5100 are programmed through the keypad, the module you are programming should be the first entry. To program the 5100 Control Panel, enter [0]-[#].
The [0] is the module number of the control and the [#] is the entry key. Other module entry numbers can be found in their corresponding manuals.
PROGRAMMING A LOCATION: Once the number of the module to be programmed has been entered, the LCD screen will prompt you for a location number. Any location can be accessed by directly entering the desired programming location followed by the pound [#] key. If the location entered is a valid location, the top line of the LCD screen will display the location number on the left and the segment number on the right. The bottom line of the display will show the current data. This data will be displayed and entered according to the type of data used (numerical, binary, or character data). Follow the instructions below for each type of data.
• NUMERICAL DATA: The top line of the display will show the current location number on the left and the segment number on the right. The data will be displayed on the bottom line. The hex equivalent will be shown in parenthesis. To change the data in the current location enter the number followed by []. The data will be entered and the segment will be incremented by 1. The data for this segment will now be displayed. Continue this process until the last segment is programmed. When the last segment is reached, the keypad will prompt you for the next location. If you wish to exit this location before the last segment is reached, press the [#] key. This keypress will not save the changes made to current segment, but will exit the location. To proceed to the next location, press the [Police] key. To return to the previous location, press the [Fire] key. To re-enter the last location, press the [Medical] key.
• BINARY DATA: The top line of the display will show the current location number on the left and the segment number on the right. The data will be displayed on the bottom line with the numbers 1-8 in the first 8 characters. If the number appears, this binary switch is on. If a minus sign ( -) appears where the number should be, this switch is off. Toggle numbers on or off using the corresponding number digit (1 to toggle 1; 8 to toggle 8). When the numbers are in the desired state, enter the [] key. The data will be entered and the segment will be incremented by 1. The data for this segment will now be displayed. Continue this process until the last segment is programmed. When the last segment is reached, the keypad will prompt you for the next location. If you wish to exit this location before the last segment is reached, press the [#] key. This keypress will not save the changes made to current segment, but will exit the location.
To proceed to the next location, press the [ Police] key. To return to the previous location, press the [Fire ] key. To re-enter the last location, press the [Medical] key.
• CHARACTER DATA: Character Data is used to enter LCD text when programming. (See []-[9]-[2] feature for custom messages, page 4.of LCD manual) Custom zone descriptions and messages are stored character or ASCII data type. This information is programmed using the bottom line of the display as a text editor. Once a character location has been entered, the current data will be displayed on the bottom line. As is always the case, the top line will display the current location and segment number. The five (5) function keys, as well as the up and down arrow to the right of the display, are now used to edit the message prior to saving it back to the location storage. An underscore (_) in the display indicates the current cursor location. To move the cursor to the right, press the [] key. To move the cursor to the left, press the [Cancel] key. To change the character at the current cursor location, press the Up or
Down Arrow until the desired character is displayed. To accept this character, press the [] key. The character will remain and the cursor will be advanced one space to the right. To insert spaces, press the [Stay] key. To delete characters, press the [Chime] key. To access the library, press the [Exit] key. Once in the library, the Up and Down
Arrow can now be used to scroll through the library. To make a character flash, press the [Bypass] key. While in the library mode, entering the flash [Bypass] key will cause the entire word to flash. To enter the word or character being displayed, enter the [] key. When done editing the line, enter the [#] key to escape from the edit mode.
• FEATURE SELECTION DATA: Feature selection data will display the current condition of eight features associated with the programming location and segment selected. Pressing a button on the touchpad (1 thru 8) that corresponds to the "feature number" within a segment, will toggle (on/off) that feature. Pressing any numeric key between [1] and [8] for selection of a feature, will make the corresponding number display (feature ON). Press the number again, and a hyphen (-) will be displayed (feature OFF). You will see that numerous features can be selected from within one segment. For instance, if all eight features of a segment are desired, pressing [1]-[2]-[3]-[4]-[5]-[6]-[7]-[8] will display numbers 1 thru 8 as you press the keys, indicating that those features are enabled. The features not enabled will display a hyphen (-). After the desired setting of features is selected for this segment, press the [] key. This will enter the data and automatically advance to the next segment of the location. When you are in the last segment of a location and press the [] to enter the data, you will exit that location. As before, you are now ready to enter another programming location.
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the program mode using the procedure on page 9, then type [9]-[1]-[0]-[#]. The keypad will beep 3 times indicating that the loading is in progress. The loading takes about 6 seconds. To load the factory defaults for the LCD keypad, enter the Program Mode from a different keypad, and follow the procedures mentioned previously.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the 5100 control panel has the ability to automatically find and store in its memory the presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal.
This allows these modules to be supervised by the control panel. NOTE: All modules should be connected and set to unique addresses prior to enrolling modules. To enroll the modules, enter the Program Mode of the 5100 control panel as described on page 9. When the Program Mode is exited, the control will enroll the devices. The enrolling process takes about 12 seconds, during which time the "Service Screen" will be displayed. User codes will not be accepted during the enrolling process. Once a module is enrolled, if it is not detected by the control, the "Service Screen” will be displayed.
QUICK START INSTALLATION
For most routine installations that will use the internal digital communicator to call a digital central station utilizing a telephone line, the "Quick Start" option will allow for enabling a majority of the options available with the 5100, when communicating in Contact ID or SIA formats and without partitioning. The "Quick Start" locations can be identified by the symbol. If you are using the 5100 in a local only configuration, see separate “Quick Start Installation
Guide”.
CONTROL PANEL PROGRAMMING LOCATIONS
LOCATION 0 - PHONE NUMBER 1 (20 segments, numerical data)
The first telephone number is programmed in location 0. A "14" indicates the end of the phone number. Delays of four seconds can be programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing, program a "15" in the first segment. Program an “11” for a “”, and a “12" for a “#”.
LOCATION 1 - ACCOUNT CODE FOR THE PHONE #1 (6 segments, numerical data)
The account code sent when Phone #1 is dialed is programmed in location 1. Program a “10" in the segment immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments.
LOCATION 2 - COMMUNICATOR FORMAT FOR PHONE #1 (1 segment, numerical data)
Location 2 contains the communicator format used to transmit to the receiver connected to Phone #1. Consult the instructions for your central station receiver to determine which format is compatible. Select a format from the list on the following page. If you require a format other than those listed, review the override options described in location 18, to build the appropriate format. A "15" must be programmed in location 2 in addition to the entries in location 18 in order to create a special format. If this location contains a "0", the built-in communicator will be disabled, and the 5100 will function as a local only control.
LOCATION 3 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE # 1 (2 segments, numerical data)
Segment 1- Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts) the communicator will make to Phone #1 before ending the notification process. Factory default is "8" and the communicator will make eight (8) attempts to the first number.
Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the 5100 to make the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop reporting.
Programming a "1" in this segment will cause the 5100 to stop trying to communicate after the designated number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the 5100 to make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two attempts to Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
FORMAT SELECTIONS
DATA
FORMAT
DESCRIPTION
Local
Communicator is disabled
Universal 4+2
Two digit event code 1800hz transmit 2300hz handshake double round parity 40pps
3+1 fast (or 4+1)
One digit event code 1900Hz transmit 1400Hz handshake double round parity 20pps
Pager
2 digit event code DTMF transmission
3/1 or 4/1 slow
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
3/1 or 4/1 slow
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
3/1 or 4/1 fast
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
3/1 or 4/1 fast
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
3/1 or 4/1 fast with parity
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
3/1 or 4/1 fast with parity
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
4+2 express
2 digit event code DTMF transmission
4+2 fast
Two digit event code 1900hz transmit 1400hz handshake double round parity 20 p.p.s.
Ademco Contact ID
DTMF (see pages 51-52)
SIA
FSK (see pages 51-52)
Custom format
(See location 18, page 16)
REPORTING EVENTS TO PHONE NUMBER 1
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should be reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be programmed as "0" (disabling all options).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1: 1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
Segment 2: 1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Over current, Ground Fault, and Restore for both.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Zone Activity Monitor 8 = Reserved.
LOCATION 5 - PARTITIONS REPORTED TO PHONE #1 (1 segment, feature selection data) Location 5 is used when events to be reported to a phone number are based upon the partition regardless of the event.
If this location is used, location 4 should be programmed as "0".
Segment 1: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8
LOCATION 6 - PROGRAMMING PHONE #2 (20 segments, numerical data)
Phone #2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing, program a "15" in the first segment. Program an “11" for a “”and a “12” for a “#”.
LOCATION 7 - ACCOUNT CODE FOR THE PHONE #2 (6 segments of numerical data)
The account code sent when Phone #2 is dialed is programmed in location 7. Program a “10” in the segment immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If this location is left unprogrammed, account code 1 will be used when the second phone number is dialed.
LOCATION 8 - COMMUNICATOR FORMAT FOR PHONE # 2 (1 segment, numerical data)
Location 8 contains the communicator format used to transmit to the receiver connected to Phone #2.