Annex A - networking requirements measurements 2.pdf
PDF 224 KB Posted
- Attached to
- GUATEMALA - NETWORK CABLING
- Solicitation number
- 19GT5025Q0042
About this file
This document is a detailed networking outlet installation plan for Office 401, covering three distinct areas with specific network connection requirements. The plan provides comprehensive documentation of network outlet placements, including single and double outlet configurations across Areas 1, 2, and 3, with precise specifications for cable and connector types.
Area 1 requires 26 double outlets and 18 single outlets, centered around a central cable termination point in the server room. Area 2 has 2 double outlets and 13 single outlets, while Area 3 has the most extensive network infrastructure with 45 double outlets and 15 single outlets. All network connections will utilize CAT6 network cables terminating in RJ45 connectors, with outlet placement guidelines specifying mounting heights between 30 cm and 2.5 meters depending on location and type of outlet. The overall networking plan covers a total space with dimensions of 25.20 meters in length, with varying area widths of 4.20 and 8.40 meters.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Office 401 Networking
AREA # 1
AREA # 2AREA # 3
25.20 mts.
8.40 mts.8.40 mts.4.20 mts. 4.20 mts.
8.
m ts
4.
m ts
Central cable termination point
Server Room
Double network outlet located on wall at at height of 2.5 mts.
Double network outlet.
• If symbol is next to a wall, locate on wall at a height no more than 30 cm.
• If symbol is not next to a wall, locate on floor.
Symbol description
Single network outlet located on wall at a height of 1.5 mts.
Same as above.
Same as above.
Same as above.
Single network outlet located on wall/ceiling at a height over 3 mts.
Single network outlet.
• If symbol is next to a wall, locate on wall at a height no more than 30 cm.
• If symbol is not next to a wall, locate on floor.
Same as above.
AREA 1 26 double outlets 18 single outlets
Central cable termination point
8.40 mts. 4.20 mts.
8.
m ts
Server Room
AREA 2 2 double outlets 13 single outlets
8.40 mts.
4.
m ts
AREA 3
45 double outlets 15 single outlets
8.
m ts
4.
m ts
8.40 mts.4.20 mts.
The single or double network outlets indicates the number of connections required by area.
Single as one network connection or Double for 2 network connections.
Each of those network connections must be installed using a network cable. The type of network cable is cat6 (category 6) which is the usual type of cable used for network connections.
Each of the network cables will end on RJ45 connectors.