Amendment 001 modifies the FBI's Request for Proposal (RFP) for a multiple-award Indefinite Delivery Indefinite Quantity (IDIQ) contract for 5.56 NATO/223 Remington Ammunition. The amendment extends the proposal submission deadline from August 29, 2025, to September 29, 2025, at 1:00 PM EST and updates several technical specifications for the ammunition, including pressure testing requirements, cartridge case markings, and packaging identification.
Key changes include modifications to pressure testing procedures, specifying compliance with SAAMI or EPVAT standards, updating requirements for cartridge case markings (to be applied only after contract award), and changing sheet metal specifications from 316 Stainless Steel to Galvanized metal. The solicitation seeks four ammunition categories: service, training reduced-lead, non-jacketed frangible, and jacketed frangible, with detailed technical requirements for performance, pressure, and environmental testing.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for Proposal (RFP) 15F06725R0000373
5.56 NATO/223 Remington Ammunition IDIQ
Service, Training Reduced-lead, Non-jacketed Frangible, and Jacketed Frangible
AMENDMENT 001
Posted to SAM.gov on July 31, 2025
001:
Section L.10 INSTRUCTIONS FOR SUBMISSION OF PROPOSALS (Page 94)
Remove:
Proposals must be received by 1:00 PM/EST on Friday August 29, 2025.
Replace:
Proposals must be received by 1:00 PM/EST on Monday September 29, 2025.
002:
Section C.4.4 Cartridge Case (Page 11)
Remove:
C.4.4.1 The cartridge case shall bear the manufacturer's name (abbreviations are acceptable) and the caliber. The year of manufacture or a code to indicate the year of manufacture is required.
Replace:
C.4.4.1 Upon contract award, the cartridge case shall bear the manufacturer's name (abbreviations are acceptable) and the caliber. The year of manufacture or a code to indicate the year of manufacture is required upon contract award.
003:
Section D.2. PACKAGING AND IDENTIFICATION (Page 16)
Remove:
D.2.3 The label or markings on the ammunition boxes and cases shall display the ammunition category (e.g., Service, Training Reduced-Lead, Non-jacketed Frangible or Jacketed Frangible) as well as the following:
Replace:
D.2.3 Upon contract award, the label or markings on the ammunition boxes and cases shall display the ammunition category (e.g., Service, Training Reduced-Lead, Non-jacketed Frangible or Jacketed Frangible) as well as the following:
004:
Section C.4.6 Pressure (Page 12)
Remove:
C.4.6.1 Ammunition shall be safe to fire in DOJ-issued firearms at temperatures between -40°F and +140°F.
When fired at temperature extremes (-40°F and +140°F), no single shot shall exceed 66,150 PSI.
C.4.6.2 At ambient temperature, Maximum Probable Sample Mean (MPSM) chamber pressures shall not exceed 58,500 PSI. No single shot shall exceed 66,150 PSI.
Replace:
C.4.6.1 Ammunition shall be safe to fire in DOJ-issued firearms at temperatures between -40°F and +140°F.
When fired at temperature extremes (-40°F and +140°F), no single shot shall exceed 66,150 PSI when tested in accordance with SAAMI or EPVAT procedures.
C.4.6.2 At ambient temperature, Maximum Probable Sample Mean (MPSM) chamber pressures shall not exceed 58,500 PSI when tested in accordance with SAAMI. The maximum lot average chamber pressure shall not exceed 58,700 PSI when tested in accordance with EPVAT. No single shot shall exceed 66,150 PSI when tested in accordance with SAAMI or EPVAT.
005:
Section M.3.5 PHASE II, TEST EVENT 6 - PENETRATION (Page 103)
Remove:
7) Sheet metal - 20 ga (.036”), 316 Stainless Steel, Cold Rolled and Annealed, 2B Finish. Available from Speedy Metals – Milwaukee, 2505 South 162nd Street, New Berlin, WI 53151, telephone (262) 784-4140, www.speedymetals.com.
Replace:
7) Sheet metal - 20 gauge (.036”), Galvanized, Cold Rolled and Annealed, 2B Finish. Available from Speedy Metals – Milwaukee, 2505 South 162nd Street, New Berlin, WI 53151, telephone (262) 784-4140, www.speedymetals.com.
006:
Section M.3.5 PHASE II, TEST EVENT 4 - SAAMI/NATO Pressure (Page 100)
Remove:
The government will review the Offeror-provided pressure test data. The chamber pressure for ten (10) rounds will be evaluated to determine if the submission is compliant with specifications for Maximum Probable Sample Mean not to exceed 58,500 pounds per square inch (PSI). Furthermore, no single round shall exceed 66,150 PSI (90% of the Minimum Average Pressure Value of Proof Cartridges of 73,500 PSI).
Replace:
The government will review the Offeror-provided pressure test data. The chamber pressure for ten (10) rounds will be evaluated to determine if the submission is compliant with SAAMI/EPVAT specifications.
For testing performed to SAAMI specification, Maximum Probable Sample Mean shall not exceed 58,500 pounds per square inch (PSI). For testing performed to EPVAT specification, maximum lot average pressure shall not exceed 58,700 PSI. Furthermore, for rounds tested to either SAAMI or EPVAT specification, no single round shall exceed 66,150 PSI.
007:
Section M.3.5 PHASE II, TEST EVENT 5 - Environmental Pressure (Page 100)
Remove:
The government will review the Offeror-provided pressure test data following exposure to extreme temperatures. The chamber pressure for ten (10) rounds for each temperature extreme will be evaluated to determine if the submission is compliant with the requirement that no single round shall exceed 66,150 PSI (90% of the Minimum Average Pressure Value of Proof Cartridges of 73,500 PSI).
A. High temperature exposure: Rounds shall be heated in an environmental chamber at 140° Fahrenheit
(F) for a period no less than 5 hours and no longer than 8 hours. Once removed from the environmental chamber, rounds shall be fired immediately, and the chamber pressures recorded.
B. Low temperature exposure: Rounds shall be cooled in an environmental chamber at negative (-) 40° F for a period no less than 5 hours and no longer than 8 hours. Once removed from the environmental chamber, rounds shall be fired immediately, and the chamber pressures recorded.
Replace:
The government will review the Offeror-provided pressure test data following exposure to extreme temperatures. The chamber pressure for ten (10) rounds for each temperature extreme will be evaluated to determine if the submission is compliant with the requirement that no single round shall exceed 66,150
PSI.
A. High temperature exposure: Pressure testing procedures shall be conducted in accordance with either SAAMI or EPVAT, except for the temperature and soak duration. Rounds shall be heated in an environmental chamber at 140° Fahrenheit (F) for a period no less than 5 hours and no longer than 8 hours. Once removed from the environmental chamber, rounds shall be fired immediately, and the pressures recorded.
B. Low temperature exposure: Pressure testing procedures shall be conducted in accordance with either SAAMI or EPVAT, except for the temperature and soak duration. Rounds shall be cooled in an environmental chamber at negative (-) 40° F for a period no less than 5 hours and no longer than 8 hours.
Once removed from the environmental chamber, rounds shall be fired immediately, and the pressures recorded.
END OF AMENDMENT 001