This is a Questions and Answers document for Request for Quotation 15B41226Q00000006 addressing an above ground tank installation project at FMC Rochester. The document does not address specific pricing terms, response dates, award dates, or contract vehicles, as it serves solely to clarify technical and procedural aspects of the solicitation.

The Q&A clarifies key project parameters including the existing underground storage tank capacities (4,000 gallons for gasoline and 2,000 gallons for diesel) and the quantities to be removed during the project (less than 1,000 gallons of gasoline to be transferred to temporary storage and approximately 1,200 gallons of diesel to be pumped out and disposed of). Regarding project scope, the BOP confirmed there are no project drawings available, but specifications are contained within the solicitation document with a site map to be added. The response indicates that concrete, bollards, and electrical work are addressed in the specifications on pages 3 and 4 respectively, clarifying that these elements are the responsibility of the bidding contractor rather than a separate cement contractor.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Request for Quotation 15B41226Q00000006 Install Above Ground Tanks – FMC Rochester Questions and Answers

Question 1:

What are the capacities/sizes of the two existing underground storage tanks for gasoline and diesel?

BOP Response: Clarification or Change Gasoline tank is 4000 gallons.

Diesel tank is 2000 gallons.

Question 2:

Approximately how many gallons of gasoline and diesel are currently remaining and expected to be pumped out and removed?

Depending on start date, we will plan on having less than 1000 gallons of gasoline to be transfered to a temp tank for the duration of the project.

Roughly 1200 gallons of diesel will need to be pumped out and disposed of.

Question 3:

Are the concrete and bollards by the cement contractor? Also, what about electrical?

BOP Response: Clarification or Change There are no project drawings. Concrete and Bollards- see page 3 of the specs. Electrical- See page 4 of the specs.

Question 4:

Are there specs and drawings available for the bid process?

BOP Response: Clarification or Change The specs are located in the solicitation. A site map will be added to the solicitation.

Question 5: