This document is a Safety Data Sheet (SDS) for the hydraulic fluid Mobil DTE 10 EXCEL 32, which is being procured under Solicitation Number 14501FY24CPPOIL for the USCGC Polar Star. The Polar Star is soliciting 2,563 gallons of this hydraulic fluid, to be delivered to the US Coast Guard Base in Seattle, WA. The vendor will be responsible for onloading the oil via a truck with a 200-foot hose and 2-inch camlock fittings. Technical inquiries should be directed to Trevor Davenport, while contracting inquiries should be addressed to Joseph Legan.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Product Name: MOBIL DTE 10 EXCEL 32 Revision Date: 06 Oct 2021
SAFETY DATA SHEET
SECTION 1 PRODUCT AND COMPANY IDENTIFICATION
PRODUCT
Product Name: MOBIL DTE 10 EXCEL 32
Product Description: Base Oil and Additives
Product Code: 201560103630, 622621
Intended Use: Hydraulic fluid
COMPANY IDENTIFICATION
Supplier: AMPOL AUSTRALIA PETROLEUM PTY LTD
ABN 17 000 032 128
29-33 Bourke Rd Alexandria New South Wales 2015 Australia
24 Hour Emergency Telephone 1800 033 111
Product Technical Information 1300364169
Supplier General Contact +612 9250-5000
FAX +612 9250-5742
SECTION 2 HAZARDS IDENTIFICATION
This material is not hazardous according to regulatory guidelines (see (M)SDS Section 15).
Other hazard information:
Physical / Chemical Hazards:
No significant hazards.
Health Hazards:
High-pressure injection under skin may cause serious damage. Excessive exposure may result in eye, skin, or respiratory irritation.
Environmental Hazards:
No significant hazards.
NOTE: This material should not be used for any other purpose than the intended use in Section 1 without expert advice. Health studies have shown that chemical exposure may cause potential human health risks which may vary from person to person.
SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS
This material is defined as a mixture.
Hazardous Substance(s) or Complex Substance(s) required for disclosure
Name CAS# Concentration* GHS Hazard Codes 2,6-DI-TERT-BUTYLPHENOL 128-39-2 0.1 - < 1% H315, H400(M factor 1), H410(M factor 1) ALKYL DITHIOPHOSPHATE Confidential 0.1 - < 1% H361(D), H361(F), H400(M factor 1), H410(M factor 10)
HYDROTREATED LIGHT PARAFFINIC DISTILLATES,
PETROLEUM
64742-55-8 20 - < 30% H304
SEVERELY HYDROTREATED HEAVY PARAFFINIC
DISTILLATE
64742-54-7 1 - < 5% H304
SOLVENT DEWAXED HEAVY PARAFFINIC DISTILLATE 64742-65-0 1 - < 5% H304
* All concentrations are percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume. Other ingredients determined not to be hazardous up to 100%.
SECTION 4 FIRST AID MEASURES
INHALATION
Immediately remove from further exposure. Get immediate medical assistance. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. Give supplemental oxygen, if available. If breathing has stopped, assist ventilation with a mechanical device.
SKIN CONTACT
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
EYE CONTACT
Flush thoroughly with water. If irritation occurs, get medical assistance.
INGESTION
Seek immediate medical attention.
NOTE TO PHYSICIAN
None
SECTION 5 FIRE FIGHTING MEASURES
EXTINGUISHING MEDIA
Appropriate Extinguishing Media: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Inappropriate Extinguishing Media: Straight streams of water
FIRE FIGHTING
Fire Fighting Instructions: Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel.
Unusual Fire Hazards: Pressurised mists may form a flammable mixture.
Hazardous Combustion Products: Aldehydes, Incomplete combustion products, Oxides of carbon, Smoke, Fume, Sulphur oxides
FLAMMABILITY PROPERTIES
Flash Point [Method]: >200°C (392°F) [ASTM D-92] Flammable Limits (Approximate volume % in air): LEL: 0.9 UEL: 7.0 Autoignition Temperature: N/D
SECTION 6 ACCIDENTAL RELEASE MEASURES
NOTIFICATION PROCEDURES
In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations.
PROTECTIVE MEASURES
Avoid contact with spilled material. See Section 5 for fire fighting information. See the Hazard Identification Section for Significant Hazards. See Section 4 for First Aid Advice. See Section 8 for advice on the minimum requirements for personal protective equipment. Additional protective measures may be necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders.
For emergency responders: Respiratory protection: respiratory protection will be necessary only in special cases, e.g., formation of mists. Half-face or full-face respirator with filter(s) for dust/organic vapor or Self Contained Breathing Apparatus (SCBA) can be used depending on the size of spill and potential level of exposure. If the exposure cannot be completely characterized or an oxygen deficient atmosphere is possible or anticipated, SCBA is recommended. Work gloves that are resistant to hydrocarbons are recommended.
Gloves made of polyvinyl acetate (PVA) are not water-resistant and are not suitable for emergency use.
Chemical goggles are recommended if splashes or contact with eyes is possible. Small spills: normal antistatic work clothes are usually adequate. Large spills: full body suit of chemical resistant, antistatic material is recommended.
SPILL MANAGEMENT
Land Spill: Stop leak if you can do so without risk. Recover by pumping or with suitable absorbent.
Water Spill: Stop leak if you can do so without risk. Confine the spill immediately with booms. Warn other shipping. Remove from the surface by skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants.
Water spill and land spill recommendations are based on the most likely spill scenario for this material;
however, geographic conditions, wind, temperature, (and in the case of a water spill) wave and current direction and speed may greatly influence the appropriate action to be taken. For this reason, local experts should be consulted. Note: Local regulations may prescribe or limit action to be taken.
ENVIRONMENTAL PRECAUTIONS
Large Spills: Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
SECTION 7 HANDLING AND STORAGE
HANDLING
Avoid all personal contact. Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. However, bonding and earthing may not eliminate the hazard from static accumulation. Consult local applicable standards for guidance.
Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity).
Static Accumulator: This material is a static accumulator.
STORAGE
The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers. Keep away from incompatible materials.
Material is defined under the National Standard [NOHSC:1015] Storage and Handling of Workplace Dangerous Goods.
SECTION 8 EXPOSURE CONTROLS / PERSONAL PROTECTION
EXPOSURE LIMIT VALUES
Exposure limits/standards (Note: Exposure limits are not additive)
Substance Name Form Limit/Standard Note Source
HYDROTREATED LIGHT
PARAFFINIC DISTILLATES,
PETROLEUM
TWA 5 mg/m3 Australia WES
HYDROTREATED LIGHT
PARAFFINIC DISTILLATES,
PETROLEUM
Inhalable fraction.
TWA 5 mg/m3 ACGIH
SEVERELY HYDROTREATED
HEAVY PARAFFINIC DISTILLATE TWA 5 mg/m3 Australia WES
SEVERELY HYDROTREATED
HEAVY PARAFFINIC DISTILLATE
Inhalable fraction.
TWA 5 mg/m3 ACGIH
SOLVENT DEWAXED HEAVY
PARAFFINIC DISTILLATE TWA 5 mg/m3 Australia WES
SOLVENT DEWAXED HEAVY
PARAFFINIC DISTILLATE
Inhalable fraction.
TWA 5 mg/m3 ACGIH
Exposure limits/standards for materials that can be formed when handling this product:
NOTE: Limits/standards shown for guidance only. Follow applicable regulations.
Biological limits
No biological limits allocated.
ENGINEERING CONTROLS
The level of protection and types of controls necessary will vary depending upon potential exposure conditions.
Control measures to consider:
No special requirements under ordinary conditions of use and with adequate ventilation.
PERSONAL PROTECTION
Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation. Information on the selection of protective equipment for use with this material, as provided below, is based upon intended, normal usage.
Respiratory Protection: If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include:
Particulate No special requirements under ordinary conditions of use and with adequate ventilation.
For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode.
Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
Hand Protection: Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions.
Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include:
Nitrile,Viton Chemical resistant gloves are recommended.
Eye Protection: If contact is likely, safety glasses with side shields are recommended.
Skin and Body Protection: Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include:
Chemical/oil resistant clothing is recommended.
Specific Hygiene Measures: Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. Discard contaminated clothing and footwear that cannot be cleaned.
Practise good housekeeping.
ENVIRONMENTAL CONTROLS
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
Note: Physical and chemical properties are provided for safety, health and environmental considerations only and may not fully represent product specifications. Contact the Supplier for additional information.
GENERAL INFORMATION
Physical State: Liquid Colour: Amber Odour: Characteristic Odour Threshold: N/D
IMPORTANT HEALTH, SAFETY, AND ENVIRONMENTAL INFORMATION
Relative Density (at 15 °C): 0.847 Flammability (Solid, Gas): N/A Flash Point [Method]: >200°C (392°F) [ASTM D-92] Flammable Limits (Approximate volume % in air): LEL: 0.9 UEL: 7.0 Autoignition Temperature: N/D Boiling Point / Range: > 316°C (600°F) Decomposition Temperature: N/D Vapour Density (Air = 1): > 2 at 101 kPa Vapour Pressure: < 0.013 kPa (0.1 mm Hg) at 20 ºC Evaporation Rate (n-butyl acetate = 1): N/D pH: N/A Log Pow (n-Octanol/Water Partition Coefficient): > 3.5 Solubility in Water: Negligible Viscosity: 32.7 cSt (32.7 mm2/sec) at 40 ºC | 6.6 cSt (6.6 mm2/sec) at 100°C [ASTM D 445] Oxidizing Properties: See Hazards Identification Section.
OTHER INFORMATION
Freezing Point: N/D Melting Point: N/A Pour Point: -45°C (-49°F) DMSO Extract (mineral oil only), IP-346: < 3 %wt
SECTION 10 STABILITY AND REACTIVITY
STABILITY: Material is stable under normal conditions.
CONDITIONS TO AVOID: Excessive heat. High energy sources of ignition.
INCOMPATIBLE MATERIALS: Strong oxidisers
HAZARDOUS DECOMPOSITION PRODUCTS: Material does not decompose at ambient temperatures.
POSSIBILITY OF HAZARDOUS REACTIONS: Hazardous polymerization will not occur.
SECTION 11 TOXICOLOGICAL INFORMATION
INFORMATION ON TOXICOLOGICAL EFFECTS
Hazard Class Conclusion / Remarks
Inhalation Acute Toxicity: No end point data for material.
Minimally Toxic. Based on assessment of the components.
Irritation: No end point data for material. Negligible hazard at ambient/normal handling temperatures.
Ingestion Acute Toxicity: No end point data for material.
Minimally Toxic. Based on assessment of the components.
Skin Acute Toxicity: No end point data for material.
Minimally Toxic. Based on assessment of the components.
Skin Corrosion/Irritation: No end point data for material.
Negligible irritation to skin at ambient temperatures. Based on assessment of the components.
Eye Serious Eye Damage/Irritation: No end point data for material.
May cause mild, short-lasting discomfort to eyes. Based on assessment of the components.
Sensitisation Respiratory Sensitization: No end point data for material.
Not expected to be a respiratory sensitizer.
Skin Sensitization: No end point data for material.
Not expected to be a skin sensitizer. Based on assessment of the components.
Aspiration: Data available. Not expected to be an aspiration hazard. Based on physico-chemical properties of the material.
Germ Cell Mutagenicity: No end point data for material.
Not expected to be a germ cell mutagen. Based on assessment of the components.
Carcinogenicity: No end point data for material.
Not expected to cause cancer. Based on assessment of the components.
Reproductive Toxicity: No end point data for material.
Contains a substance that may be a reproductive toxicant. Based on assessment of the components.
Lactation: No end point data for material. Not expected to cause harm to breast-fed children.
Specific Target Organ Toxicity (STOT) Single Exposure: No end point data for material.
Not expected to cause organ damage from a single exposure.
Repeated Exposure: No end point data for material.
Not expected to cause organ damage from prolonged or repeated exposure. Based on assessment of the components.
OTHER INFORMATION
Contains:
Base oil severely refined: Not carcinogenic in animal studies. Representative material passes IP-346, Modified Ames test, and/or other screening tests. Dermal and inhalation studies showed minimal effects; lung non-specific infiltration of immune cells, oil deposition and minimal granuloma formation. Not sensitising in test animals.
IARC Classification:
The following ingredients are cited on the lists below: None.
--REGULATORY LISTS SEARCHED--
1 = IARC 1 2 = IARC 2A 3 = IARC 2B
SECTION 12 ECOLOGICAL INFORMATION
The information given is based on data for the material, components of the material, or for similar materials, through the application of bridging principals.
ECOTOXICITY
Material -- Not expected to be harmful to aquatic organisms.
MOBILITY
Base oil component -- Low solubility and floats and is expected to migrate from water to the land.
Expected to partition to sediment and wastewater solids.
PERSISTENCE AND DEGRADABILITY
Biodegradation:
Base oil component -- Expected to be inherently biodegradable
BIOACCUMULATION POTENTIAL
Base oil component -- Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.
ECOLOGICAL DATA
Ecotoxicity Test Duration Organism Type Test Results Aquatic - Chronic Toxicity 21 day(s) Daphnia magna NOELR 1.05 mg/l: data for similar materials
SECTION 13 DISPOSAL CONSIDERATIONS
Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.
DISPOSAL RECOMMENDATIONS
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products. Protect the environment. Dispose of used oil at designated sites. Minimize skin contact. Do not mix used oils with solvents, brake fluids or coolants.
Empty Container Warning Empty Container Warning (where applicable): Empty containers may contain residue and can be dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed. Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION.
THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.
SECTION 14 TRANSPORT INFORMATION
LAND (ADG) : Not Regulated for Land Transport
SEA (IMDG): Not Regulated for Sea Transport according to IMDG-Code
Marine Pollutant: No
AIR (IATA): Not Regulated for Air Transport
SECTION 15 REGULATORY INFORMATION
This material is not considered hazardous according to Australia Model Work Health and Safety Regulations.
Product is not regulated according to Australian Dangerous Goods Code.
No Poison Schedule number allocated by the Standard for the Uniform Scheduling of Medicines and Poisons (SUSMP) established under the Therapeutic Goods Act.
AS1940 COMBUSTIBLE CLASS: C2
REGULATORY STATUS AND APPLICABLE LAWS AND REGULATIONS
Listed or exempt from listing/notification on the following chemical inventories : AIIC, ENCS, ISHL, KECI, PICCS, TCSI, TSCA
Special Cases:
Inventory Status IECSC Restrictions Apply NDSL Restrictions Apply
SECTION 16 OTHER INFORMATION
KEY TO ABBREVIATIONS AND ACRONYMS:
N/D = Not determined, N/A = Not applicable, STEL = Short-Term Exposure Limit, TWA = Time-Weighted Average
KEY TO THE H-CODES CONTAINED IN SECTION 3 OF THIS DOCUMENT (for information only):
H304: May be fatal if swallowed and enters airways; Aspiration, Cat 1 H315: Causes skin irritation; Skin Corr/Irritation, Cat 2 H361(D): Suspected of damaging the unborn child; Repro Tox, Cat 2 (Develop) H361(F): Suspected of damaging fertility; Repro Tox, Cat 2 (Fertility) H400: Very toxic to aquatic life; Acute Env Tox, Cat 1 H410: Very toxic to aquatic life with long lasting effects; Chronic Env Tox, Cat 1
THIS SAFETY DATA SHEET CONTAINS THE FOLLOWING REVISIONS:
Section 01: Company Mailing Address information was modified.
Section 09: Vapour Pressure information was added.
The information and recommendations contained herein are, to the best of ExxonMobil's knowledge and belief, accurate and reliable as of the date issued. You can contact ExxonMobil to insure that this document is the most current available from ExxonMobil. The information and recommendations are offered for the user's consideration and examination. It is the user's responsibility to satisfy itself that the product is suitable for the intended use. If buyer repackages this product, it is the user's responsibility to insure proper health, safety and other necessary information is included with and/or on the container. Appropriate warnings and safe-handling procedures should be provided to handlers and users. Alteration of this document is strictly prohibited. Except to the extent required by law, re-publication or retransmission of this document, in whole or in part, is not permitted. The term, "ExxonMobil" is used for convenience, and may include any one or more of ExxonMobil Chemical Company, Exxon Mobil Corporation, or any affiliates in which they directly of indirectly hold any interest.
DGN: 7093387DAU (1016056)
Prepared by: Exxon Mobil Corporation EMBSI, Clinton NJ USA Contact Point: See Section 1 for Local Contact number
End of (M)SDS