62828-90149 REV E.pdf
PDF 449 KB Posted
- Attached to
- Surge Connectors
- Solicitation number
- 142082-25-0058
About this file
This is a specification control drawing (document number 62828-90149 Rev E) detailing requirements for an RJ-11 telephone RFI/surge adapter. The adapter must function as a filter/surge suppressor providing EMI and lightning protection for telephone signals, with specifications including operation at 200 VAC, 0.5 amperes per pin current rating, and DC resistance of 0.2 ohms or less. The device requires RJ-11 socket connectors on both ends with a mounting flange containing two #4-40 screw inserts.
The related federal contract opportunity (142082-25-0058) is a solicitation from NOAA's National Logistics Support Center in Grandview, MO for EMI Surge Connectors. It is structured as a firm-fixed-price contract and total small business set-aside, with award to be made to the responsive, responsible small business offering best value. Vendors must be registered in SAM.gov to be considered for award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 62828-90148 REV E.pdf | ||
| 032-1 Solicitation.pdf | ||
| Instructions to Offerors.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| | 62828-40340| ASOS | REVISIONS |
| | 62828-40290| ASOS |REV| DESCRIPTION | DATE | APPROVED |
|--| 62828-40061| ASOS | A | INC A01 (ECN 15397), | | |
| | 62828-40374| ASOS | | A02 (ECN 19029) |92-10-11| TBN |
| | 62828-40044| ASOS | B | INC B01 (ECN 20578) |93-03-22| TBN |
| | 62828-40000| ASOS | C | INC C01 (ECN 25908) |95-06-15| CDR |
| | NEXT ASSY | USED ON | D | INC D01 (ECN 28484) |96-05-21| CDR |
| | APPLICATION | E | INC E01 (ECN 31214) |97-06-11| CGF |
---| This item also appears as a line callout on the following drawings: 62828-40044 | | 62828-40070 |
| SPECIFICATION CONTROL DRAWING |
| REV | | | | | | | | | | | | | | | | | | | | | | | | | | |
| SHEET |23|24|25|26|27|28|29|30|31|32|33|34|35|36|37|38|39|40|41|42|43|44|45|46|47|48 |
| REV STATUS | REV | E| E| E| E| E| E| E| E| E| E| | | | | | | | | | | | |
| OF SHEETS |SHEET| 1| 2| 3| 4| 5| 6| 7| 8| 9|10|11|12|13|14|15|16|17|18|19|20|21|22 |
| UNLESS OTHERWISE |CONTR | |
| SPECIFIED, DIM. | 50-SANW-1-00050 | AAI CORPORATION |
| ARE IN INCHES. |----------------------| |
| |DFTG P COLLINS | HUNT VALLEY, MD 21030-0126 |
| | 91-07-18 | | | UNLESS OTHERWISE |CHECKING T NGUYEN |-------------------------------------------|
| SPECIFIED, TOL. | 91-07-18 | |
| ON ALL DIM. .01 |----------------------| |
| |ENGRG J ROWE | ADAPTER, RFI/SURGE, RJ-11 |
| | 91-07-18 | |
| |PROJ A LAYMAN |-------------------------------------------|
| | 91-07-18 |SIZE |CAGE CODE |DWG. NO. |
| |----------------------| A | 97384 | 62828-90149 |
| | |SCALE NONE |SHEET 1 OF 10 |
1.0 SCOPE
1.1 SCOPE. This specification covers the requirement for a RJ-11 telephone, RFI (Radio Frequency Interference) surge adapter.
2.0 APPLICABLE DOCUMENTS
2.1 ISSUE OF DOCUMENTS. The following documents of the issue in effect on date of invitation for bids or request for proposal form a part of this specification.
2.2 MILITARY STANDARDS.
DOD-STD-100 Engineering Drawing Practices
MIL-STD-129 Marking for Shipment and Storage
2.3 OTHER DOCUMENTS.
NATIONAL WEATHER SERVICE, TRANSIENT SUSCEPTIBILITY STANDARD
3.0 REQUIREMENTS
3.1 ORDER OF PRECEDENCE. This drawing takes precedence over documents referred to herein and shall be interpreted in accordance with DOD-
STD-100.
3.2 VISUAL. The adapter shall meet the dimensional requirements of
Figure 1.
3.3 SPECIFICATIONS.
3.3.1 GENERAL DESCRIPTION. The adapter shall be a filter/surge suppressor to perform EMI (Electromagnetic Interference) and surge protection (lightning) on telephone signals.
3.3.2 DETAIL SPECIFICATION. The filter/suppressor shall operate with normal switched telephone signal levels. It must pass the AC
(Alternate Current) ring voltage of approximately 170 VAC (Volts
Alternating Current) as well as audio up to 4 kHz). There shall be
4 pins on each filter. All four pins shall be filtered and protected for surge. Surge protection shall be shunted to case ground.
3.3.3 POWER REQUIREMENTS.
Current rating: load current, 0.5 amperes per pin.
Operating voltage: 200 VAC.
DC (Direct Current) resistance : 0.2 ohms or less.
3.3.4 PHYSICAL REQUIREMENTS. The input end of the housing shall have a
RJ-11 socket telephone connector and a mounting flange. The flange shall have two #4-40 screw inserts. The output end shall also have a RJ-11 connector. The pins shall be wired pin to pin (i.e., pin 1 to pin 1, pin 2 to pin 2, pin 3 to pin 3, and pin 4 to pin 4).
| SIZE A | DRAWING NUMBER 62828-90149 |
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 3 |
3.3.5 EMI FILTER CHARACTERISTICS The adapter shall include EMI filters.
All 4 pins shall meet the filter requirements stated below.
3 dB point shall be 1.6 MHz .1 Mhz.
Minimum no load insertion loss (approximate) 2 dB:
FREQUENCY (MHz) dB
25 MHz 23
50 29
100 35
300 45
500 49
1000 55
3.3.6 SURGE SUPPRESSION CHARACTERISTICS. Surge suppression shall be in accordance with the National Weather Service, Transient
Susceptibility Standard.
Cross talk transients:
Quotation from National Weather Service (NWS), Transient
Figure 1. Dimensional Diagram
Adapter, RFI/Surge, RJ-11
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 4 |
Susceptibility Standard.
"Cross talk can result from the transients on AC power lines being coupled into adjacent signal or control lines. Therefore, the same transient pulse used in the power line test shall be inductively coupled to the signal/control line." Figures 2 and 3 show the voltage transient and test setup. The test filters shall be subjected to
50 repetitions of the above transient. The filter must protect the
"equipment under test" from permanent damage when subjected to this transient; i.e., the "equipment under test" shal continue to operate normally after the transient has been applied.
Lightning: "Some equipment in use by the NWS will be interconnected by signal or control lines susceptible to pickup from lightning strikes in the vicinity and as such, could experience transients of the same as those introduce on power lines. For equipment in this category, provision is customarily made in the design or procurement specification to provide protective devices such as absorbers, by-passes, gas discharge components, etc. The purpose of this standard is to provide a uniform and repeatable test method to objectively assess the protective suitability of these devices for the purpose intended. The lightning transient consists of a 800 V peak voltage with a 2 μsec rise time and a decay time greater than
25 μsec." Figures 4, 5, and 6 depict the lightning transient testing setup. The filter must protect the equipment under test from permanent damage when subjected to this transient. Common mode and transverse mode testing shall be preformed (see Figures 5
& 6). Test filters will be subjected to 30 such pulses in each mode of test. The test filters must survive these tests and protect the equipment under test. The surge protection shall be a minimum of 1200 amperes per signal line.
Figure 2. Power Line Transient
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 5 |
Figure 3. Signal Line Test Set-Up
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 6 |
Figure 4. Lightning Spike Specifications
Figure 5. Common Mode Lightning Transient
Figure 6. Transverse Mode Lightning Transient
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 7 |
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 8 |
3.4 ENVIRONMENTAL.
3.4.1 OPERATING.
Temperature.................. -17C to +49C
3.4.2 STORAGE.
Temperature.................... -51C to +60C
3.5 IDENTIFICATION MARKING. Each part or package containing the part shall be identifiable from markings applied to the part/package.
The markings shall be applied as described in options A or B.
Unless otherwise stated in contract or purchase order, Option A shall be the default marking option.
Option A: Each part or package containing the part shall be marked with the vendor's CAGE code or name or trademark and complete part number.
Option B: Each part shall be marked as indicated in Option A. Additionally, each part procured shall be individually packaged and marked with the following information on the package in accordance with MIL-
STD-129: National Stock Number (NSN), Weather Service Number
(WSN), Project Number and Item Number, Serial Number, Contractor
Part Number and Contractor and Government Entity (CAGE) Code, Item
Nomenclature, Quantity in Package and Unit of Issue (U/I), Contract
Number and Contract Line Item Sequence Number, Shelf Life
Expiration Life (S/L EXP) (if no shelf life, state "None"), and
Hazardous Material Identification (HAZ MATL).
The following shows the format of this information, as it shall be applied to the packaging. Information to be included in this format shall be provided in the purchase order or contract placed with the vendor.
NSN:XXXXXXXXXX
WSN:XXXXXXXXXX
Proj.No: XXXXXXXXXX Item:XXX
S/N: XXXXXXXXXX
P/N: XXXXX-XXXXX-XCAGE: XXXXX
ADAPTER, RFI/SURGE, RJ11
QTY: XXXU/I:EA
CONT: XX-XXXX-X-XXXXX
CLIN:XXXX
S/L EXP: NONE
HAZ MATL: NONE
3.6 WORKMANSHIP. Each adapter shall be manufactured and processed in a careful and workmanlike manner in accordance with acceptable manufacturing practice. All adapters shall be thoroughly clean of all foreign material. There shall be no defects that would adversely affect life, serviceability, performance, or appearance.
4.0 QUALITY ASSURANCE PROVISIONS
| SCALE NONE | CAGEC 97384 | REVISION E | SHEET 9 |
4.1 RESPONSIBILITY FOR INSPECTION. Unless otherwise specified in the contract, the supplier is responsible for the performance of all inspection requirements specified herein. The supplier may use his own or any other facilities suitable for the performance of the inspection.
4.2 METHODS OF INSPECTION.
4.2.1 VISUAL AND MECHANICAL. The adapter shall be visually examined to verify that the materials and workmanship are in accordance with this specification.
5.0 PREPARATION FOR DELIVERY
5.1 GENERAL. The adapter shall be free of dirt and contaminants that would contribute to or cause deterioration during shipment and storage or would have to be removed by the customer prior to use.
5.2 SHIPMENT. Shipment shall be by best commercial practice to assure safe delivery via common carrier.
6.0 NOTES
6.1 SUGGESTED SOURCES OF SUPPLY.
| AAI | SUPPLIER DATA |
| CONTROL |---------------------------------------------------------------|
| NUMBER | CAGEC | PART NUMBER | VENDOR NAME & ADDRESS |
| 62828-90149-1 | 0D3H0 | 52-21-01 | Caron Enterprises, Inc. |
| | | | Girard, PA 16417 |
6.2 Identification of the suggested source(s) of supply hereon is not to be construed as a guarantee of present or continued availability as a source of supply for the item described on the drawing.
File details come from the government source that posted it. Updated .