N64498-22-SIMACQ-PD-1410-0005_E5b_Drawing_85T FCE Cross section.pdf

PDF 2 MB Posted

Attached to
Furnace Reline IDIQ
Solicitation number
1410-0005
Issued by

About this file

This document appears to be a drawing for an 85-ton furnace cross-section. The drawing provides detailed specifications and dimensions for the furnace, including the hot face, coils, grout, and billet size.

The related federal contract opportunity is for the relining of seven different coreless induction furnaces at the Naval Foundry and Propeller Center (NFPC) located in Philadelphia, PA. The furnaces range in size from 3 tons to 85 tons. The contractor will be responsible for performing the tasks outlined in the Statement of Work of the attached solicitation to ensure the furnaces are fully operational and in good working condition after the repair.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

C C

D D

STD

REVTOT. SHT'S.SHT. #DRAWING NO.SCALEDATE:APPR. BY:DRAWN BY:

BORDER SIZE

DRAWING TYPE

SEPARATE BOM:

IDW

YES NO

COPYRIGHT ©

AJAX TOCCO MAGNETHERMIC 2017

CORPORATE

HEADQUARTERS

1745 OVERLAND AVE

WARREN, OH. 44483

330-372-8511

THIS DRAWING IS PROPERTY OF

AJAX TOCCO MAGNETHERMIC

AND MAY CONTAIN PROPRIETARY INFORMATION. IT IS NOT TO BE COPIED OR DUPLICATED

IN ANY MANNER OR SUBMITTED TO OUTSIDE PARTIES FOR EXAMINATION WITHOUT THE KNOWLEDGE

& CONSENT OF AJAX TOCCO MAGNTHERMIC. IT SHALL BE USED ONLY AS A MEANS OF REFERENCE

FOR WORK FURNISHED BY AJAX TOCCO MAGNETHERMIC. THE DESIGNS HEREIN MAY BE COVERED BY

ONE OR MORE PATENTS OWNED BY AJAX TOCCO MAGNETHERMIC. TRANSFER OF THIS DRAWING DOES

NOT IMPLY ANY LICENSE. IT IS NOT TO BE USED TO BUILD, REBUILD, REPAIR OR RECONSTRUCT A

PRODUCT OF AJAX TOCCO MAGNETHERMIC EXCEPT FOR IN HOUSE MAINTENANCE & REPAIR

TOLERANCES

DIMENSIONS IN PARENTHESIS ARE REFERENCE ONLY.

BUILD TO PRIMARY DIMENSIONS.

TOLERANCES UNLESS OTHERWISE SHOWN:

HOLES & MACH

.X

.XX

.XXX

FABRICATION

X

X.X

.XX UNDER 36"

.XX 36" & OVER

ANGLES

±.01

±.005

±.25

±.125

±.0625

±.125

±.5°

±.25

±.13

±6

±3

±1.6

±3

±.5°

INCH MM

jax TOCCO

Magnethermic

A UNIT OF PARK OHIO INDUSTRIES

1JCWKMS

11/22/2017

M-16-70323

85 TON FURNACE CROSS-SECTION

D

X

X

1 : 20

5/18/2018

JCWDRBGENERAL UPDATE3

4/17/2018

RAFCHANGE CUSTOMER BILLET DIAMETER TO 74 FROM 75 AND HEIGHT TO 143.38 FROM 139.52

3/23/2018

JCWRAFADDED TAPERED LINING AND CHANGED DIAMTER TO 87"1

3/23/2018

JCWKMSINITIAL RELEASE0

DATEAPPR.BYDESCRIPTIONNo.

A

A

SECTION A-A

SCALE 1 : 20

249682#

Ø

COG

H

O T

F A C E

T O

P

C A S T

8.00

MIN

8.00

MIN

Ø

B T M

M

E L T

D

I A

20.00

12.93

REF

.50154.50 SHUNTS

.50155.00 COIL1.18

20.00

1.68

26.50

225.18

SLIP PANE BETWEEN

GROUT & HOT FACE

Ø

C O

I L

I D

155.00 GROUT TAPER

MK

A

85 TON FURNACE CROSS-SECTION

M

I

N n

C U

S T O

M E R

B I L L E T

143.38 CUSTOMER BILLET

n

C O

I L

G

R O

U T

T O

P n

C O

I L

G

R O

U T

B O

T T O

M

113.32

I N

³

L B S

L B S I N

³

44.68

AS BUILT

AutoCAD SHX Text

ESTIMATED WEIGHT =

Sheets and Views
M-16-70323-1-Layout1

File details come from the government source that posted it. Updated .