The related federal contract opportunity is for the relining of seven different coreless induction furnaces at the Naval Foundry and Propeller Center (NFPC) located in Philadelphia, PA. The furnaces range in size from 3 tons to 85 tons. The contractor will be responsible for performing the tasks outlined in the Statement of Work of the attached solicitation to ensure the furnaces are fully operational and in good working condition after the repair.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A A
B B
C C
D D
STD
REVTOT. SHT'S.SHT. #DRAWING NO.SCALEDATE:APPR. BY:DRAWN BY:
BORDER SIZE
DRAWING TYPE
SEPARATE BOM:
IDW
YES NO
COPYRIGHT ©
AJAX TOCCO MAGNETHERMIC 2017
CORPORATE
HEADQUARTERS
1745 OVERLAND AVE
WARREN, OH. 44483
330-372-8511
THIS DRAWING IS PROPERTY OF
AJAX TOCCO MAGNETHERMIC
AND MAY CONTAIN PROPRIETARY INFORMATION. IT IS NOT TO BE COPIED OR DUPLICATED
IN ANY MANNER OR SUBMITTED TO OUTSIDE PARTIES FOR EXAMINATION WITHOUT THE KNOWLEDGE
& CONSENT OF AJAX TOCCO MAGNTHERMIC. IT SHALL BE USED ONLY AS A MEANS OF REFERENCE
FOR WORK FURNISHED BY AJAX TOCCO MAGNETHERMIC. THE DESIGNS HEREIN MAY BE COVERED BY
ONE OR MORE PATENTS OWNED BY AJAX TOCCO MAGNETHERMIC. TRANSFER OF THIS DRAWING DOES
NOT IMPLY ANY LICENSE. IT IS NOT TO BE USED TO BUILD, REBUILD, REPAIR OR RECONSTRUCT A
PRODUCT OF AJAX TOCCO MAGNETHERMIC EXCEPT FOR IN HOUSE MAINTENANCE & REPAIR
TOLERANCES
DIMENSIONS IN PARENTHESIS ARE REFERENCE ONLY.
BUILD TO PRIMARY DIMENSIONS.
TOLERANCES UNLESS OTHERWISE SHOWN:
HOLES & MACH
.X
.XX
.XXX
FABRICATION
X
X.X
.XX UNDER 36"
.XX 36" & OVER
ANGLES
±.01
±.005
±.25
±.125
±.0625
±.125
±.5°
±.25
±.13
±6
±3
±1.6
±3
±.5°
INCH MM
jax TOCCO
Magnethermic
A UNIT OF PARK OHIO INDUSTRIES
1JCWKMS
11/22/2017
M-16-70323
85 TON FURNACE CROSS-SECTION
D
X
X
1 : 20
5/18/2018
JCWDRBGENERAL UPDATE3
4/17/2018
RAFCHANGE CUSTOMER BILLET DIAMETER TO 74 FROM 75 AND HEIGHT TO 143.38 FROM 139.52
3/23/2018
JCWRAFADDED TAPERED LINING AND CHANGED DIAMTER TO 87"1
3/23/2018
JCWKMSINITIAL RELEASE0
DATEAPPR.BYDESCRIPTIONNo.
A
A
SECTION A-A
SCALE 1 : 20
249682#
Ø
COG
H
O T
F A C E
T O
P
C A S T
8.00
MIN
8.00
MIN
Ø
B T M
M
E L T
D
I A
20.00
12.93
REF
.50154.50 SHUNTS
.50155.00 COIL1.18
20.00
1.68
26.50
225.18
SLIP PANE BETWEEN
GROUT & HOT FACE
Ø
C O
I L
I D
155.00 GROUT TAPER
MK
A
85 TON FURNACE CROSS-SECTION
M
I
N n
C U
S T O
M E R
B I L L E T
143.38 CUSTOMER BILLET
n
C O
I L
G
R O
U T
T O
P n
C O
I L
G
R O
U T
B O
T T O
M
113.32
I N
³
L B S
L B S I N
³
44.68
AS BUILT
AutoCAD SHX Text
ESTIMATED WEIGHT =
| Sheets and Views |