Final_Medicine_Creek_Dam_Sources_Sought_Notice_5-7-2024_1.pdf

PDF 4 MB Posted

Attached to
Medicine Creek Dam Concrete Spillway Repair
Solicitation number
140R6024R0020
Issued by

About this file

This document is a Sources Sought Announcement for the Medicine Creek Dam Concrete Repair of damaged spillway concrete and Access Improvements project. The Bureau of Reclamation is seeking information on potentially interested contractors with specialized knowledge, experience, and resources to successfully complete this project, which has an estimated value between $1,000,000 and $5,000,000. The principal components of work include construction management, site access road construction, concrete removal and replacement within the spillway chute and outlet works stilling basin, and spillway bridge pier repairs. Capability statements are due by May 17, 2024, and should include details on the contractor's qualifications and past relevant projects. This announcement is not a solicitation for proposals, and a contract will not be awarded as a result of this notice. The government will use the responses to develop an acquisition strategy for this project.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

This is a Sources Sought Announcement for Medicine Creek Dam Concrete Repair of damaged spillway concrete and Access Improvements. The purpose of this notice is to gain knowledge regarding the types of interested contractors and their qualifications. The Bureau of Reclamation will use information obtained through this notice to develop an acquisition strategy. Proposals are not requested and will not be accepted from this Sources Sought Notice. THIS IS NOT A SOLICITATION

FOR PROPOSALS AND A CONTRACT WILL NOT BE AWARDED AS A RESULT OF THIS NOTICE.

Work is located at Medicine Creek Dam, which is approximately 11 miles north of Cambridge, Nebraska in Frontier County and forms Harry Strunk Lake. This earthfill embankment dam has a structural height of 165 feet and an uncontrolled spillway on the left abutment which empties back into Medicine Creek. The outlet works through the dam is controlled by a high-pressure gate and releases flow into an armored channel downstream.

The principal components of work that would be completed under this project include the following:

A. Provide construction management, including submittal preparation, transmittal, comment incorporation, and resubmittal process;

B. Construct a site access road, including culverts at the outlet works discharge channel crossing;

C. Saw cut and remove existing concrete from damaged areas within the spillway chute and along the outlet works stilling basin walls;

D. Furnish and place new concrete in repair areas, and raise the outlet works walls by 2 feet;

E. Repair cracked concrete on the spillway bridge piers;

F. Project closeout and lessons learned.

See attached drawings and pictures for more information.

The Government is seeking potentially interested contractors who have the specialized knowledge, experience and resources required to successfully complete a project of this size, scope and complexity particularly as it relates to specialized dam concrete spillway repairs. The NAICS Code for this project is 237990 – Other Heavy and Civil Engineering Construction with a business size standard of $45 million. In accordance with FAR 36.204, the estimated magnitude of this proposed construction project is between $1,000,000 and $5,000,000.

If your business believes it is qualified and able to perform the work required under this proposed project, please submit a capability statement demonstrating its ability to successfully manage and accomplish the various components of work outlined above. Potential contractors shall furnish a list of no more than three (3) Federal, State, local government, or commercial projects completed within the last 10 years, which are similar in scope and complexity to the work identified under this Sources Sought Notice. You must clearly demonstrate in your capability statement the ability to successfully complete projects in a timely manner, manage a variety of construction disciplines and work collaboratively with owners. Projects similar in scope and complexity are those projects having similar principal components of work, with a contract dollar value previously identified.

Interested businesses shall also include the following information with their capability statement:

1) Company Name:

2) Address:

3) Point of Contact:

4) Phone Number:

5) Email:

6) Business type (Socio-economic classification under the NAICS 237990):

7) Unique Entity Identifier (UEI):

8) Confirm active registration in System for Award Management (SAM):

If you intend to utilize subcontractors for specified work activities, you should demonstrate the subcontractor’s experience with these identified work activities on similar projects. The Government requests the following information be provided to the maximum extent possible for each potential subcontractor’s project(s):

1) Name and location of project;

2) Description of work;

3) Whether the potential subcontractor was the prime contractor, what portion of the work was performed by the potential subcontractor, and what portion of the work was performed by subcontractors;

4) Original completion date and actual dates and duration for each project (including modifications);

5) Initial contract amount and final contract amount (including modifications);

6) Name, address, and phone number of CO/owner/COR/point-of-contact who may verify information for the project(s); and,

7) Any problems encountered in performance of the work and corrective actions taken.

The Government will not reimburse any costs associated with responding to this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract nor does it restrict the Government to a particular acquisition approach. The Government will not be bound to this information if a solicitation is issued. A determination by the Government not to compete this proposed contract action, based on the responses to this notice is at the discretion of the Government.

Capability statements shall be submitted to Kent Munro at kmunro@usbr.gov by close of business on May 17, 2024.

For record keeping purposes, telephonic inquiries will not be accepted.

Spillway

Stilling Basin

Spillway face concrete crack repair area

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0-

3-

R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-0 1-

LA

S T

S A V

ED

B Y

N

LO

W E

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

SITE PLAN

BILLINGS, MT

328-600-60063

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

Enzenbacher, Dominick R

Walsh, Christie S

Lowe, Nathan J

Outlet works Stilling BasinCR 728

Republican River

Existing access road

To CR 73A and Borrow Area (see Note 3)

See Note 1

New Access Road

Existing Access Roads

Whooping Crane Habitat Area

Contractor Staging Area (see Note 2)

LEGEND

0 400'200'

CR 73A (see Note 3)

Borrow Area

Borrow Area (see Note 3)

New Access Road & Culvert

REFERENCE DRAWINGS

Medicine Creek Dam

Spillway - Floor Repair - General Plan 328-600-60064 Spillway - Wall Repair - Profile 328-600-60075 Spillway - Bridge Pier Concrete Repairs - Plan, Profiles, and Sections 328-600-60077 Outlet Works - Stilling Basin Wall Repair - Plan, Profile, Sections, and Details 328-600-60078 Spillway - Access Road - Site Plan 328-600-60079

NOTES

1. Existing access road around north of outlet works shall be used for light vehicle access only

(i.e. no heavy equipment or trailers).

2. Strip and stockpile for contractor staging as necessary.

3. Borrow area is approximately 1 mile north of the intersection of Road 728 and CR73A.

Take the next left after Trail 4 Road.

R el ea se d

AutoCAD SHX Text

ALWAYS THINK

AutoCAD SHX Text

SAFETY

.0

.0

.0

Dimensions symmetrical about Spillway ℄

50433629221581

2 9 16 23 30 37 44 51

3 10 17 24 31 38 45 52

5 12 19 26 33 40 47 54

6 13 20 27 34 41 48 55

7 14 21 28 35 42 49 56

0 15' 30'

95 96

4 11 18 25 32 39 46 53

89 90

S ta

S ta

S ta

S ta

S ta

S ta

S ta

S ta

.1

GENERAL PLAN

Normal to Surface

.0

S ta

FLOW

Left wall repairs (see Dwg. 328-600-60075)

Right wall repair (see Dwg. 328-600-60075)

28.86' 29.06' 29.06' 26.32' 27.11' 28.50' 29.07' 27.95'

LEGEND

Concrete Repairs

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway

Site Plan 328-600-60063 Floor Repair - Details 328-600-60065 Floor Repair - Panels 1 to 96 328-600-60066 to -60074 Wall Repair - Profile 328-600-60075 Plan and Sections 328-D-580 Floor - Sta. 10+98 to Sta. 13+40 - Plan and Sections 328-D-731 Floor - Panels 1 to 24 - Reinforcement 328-D-732 to -735 Walls - Plan, Elevation and Sections 328-D-738 and -739 Walls - Sta. 10+80 to Sta. 13+12 - Reinforcement 328-D-746, -747, -750, and -754

GENERAL NOTES

1. Dimensions of repair areas are based on previous investigations as recent as 2021, and will be field adjusted as needed by the Contracting Officer's Representative.

2. Existing concrete shall be clean and saturated surface dry prior to installing replacement concrete.

3. Replacement concrete shall be finished to provide a smooth surface that is even with the existing concrete, and to the original lines and grades as shown on Drawing No. 328-D-580.

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

FLOOR REPAIR

GENERAL PLAN

BILLINGS, MT

328-600-60064

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Enzenbacher, Dominick R

Enzenbacher, Dominick R

Lowe, Nathan J

Lowe, Nathan J P.E.

Skinner, Norris (David)Skinner, Norris (David) ivi n ineer o e, Na an e e a s e d

AutoCAD SHX Text

ALWAYS THINK

No kerfs allowed beyond tangents of corner cores

Core 2"Ø holes at corners

90°

2" Saw cut around perimeter

90° min.

270° max.

(typ.)

90°

Transverse joint

Longitudinal joint

A

C

B

Limits of damaged concrete

TYPICAL FLOOR PANEL REPAIR

av g.

m in

See Note 4

80° (typ.)

3" se e

N ot e 3)

8" se e

N ot e 5)

#8@12" o.c.e.w.

(see Note 2)

See Note 6

See Note 7

2" se e

N ot e 3)

℄ corner cores Saw cut

REPAIR EDGEA

6" (see Note 8)

1-5/8"5- 5/

8"

1- 5/

8"

1/ 2"

1/2" formed chamfer

8" se e

N ot e 5)

Slope varies 16:1 to 2:1

Varies (3" min.)

Varies (3" min.)

TRANSVERSE JOINTB

See Note 6

See Note 7

CrJ

4" 3-

5/ 8"

3"

1-5/8"

8" se e

N ot e 5)

2"

2" 2"

Alternate position of key

3" 3"

3"3"

LONGITUDINAL JOINTC

See Note 6

See Note 7CrJ

LEGEND

Saw cut

Normal concrete removal

Existing reinforcement

NOTES

1. For general concrete outline notes, refer to Drawing No. 328-600-60064.

2. Preserve existing reinforcement per Specifications.

3. Depth of existing reinforcement (where present) is assumed to be 3 inches. Saw cut and drill cores around repair perimeters to a maximum depth of 2 inches.

4. Where existing reinforcement is exposed by concrete removal, adjust location of repair edge as necessary to provide a minimum clear distance of 1.5 times the new concrete's maximum aggregate size behind existing reinforcement.

5. Remove spillway floor concrete to a depth of (a) 8 inches from the existing surface, OR (b) 1.5 times the maximum aggregate size of new concrete below existing reinforcement (where present), OR (c) to sound concrete as determined by COR, whichever is greater.

6. Clean and dry existing concrete to saturated surface dry condition prior to installing replacement concrete.

7. Finish new concrete to provide a smooth, even surface and a flush interface with the existing concrete. Unless otherwise noted, match original lines and grades.

8. When placing new concrete immediately downstream of transverse joints, bevel finish from original grade at 6 inches downstream of the joint to a depth of 1/2 inches below original grade at the joint.

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway

Floor Repair - General Plan 328-600-60064 Plan and Sections 328-D-580 Floor - Sta. 10+98 to Sta. 13+40 - Plan and Sections 328-D-731 Floor - Panels 1 to 24 - Reinforcement 328-D-732 to -735

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

FLOOR REPAIR

DETAILS

BILLINGS, MT

328-600-60065

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Enzenbacher, Dominick R

Enzenbacher, Dominick R

Lowe, Nathan J

Lowe, Nathan J P.E.

Skinner, Norris (David)Skinner, Norris (David) ivi n ineer o e, Na an e e a s e d

AutoCAD SHX Text

ALWAYS THINK

EL

EV

A

TI

O N

STATION

11+00 11+20 11+40 11+60 11+80 12+00 12+20 12+40 12+60 12+80 13+00 13+20 13+40

Existing spillway joint (typ.)

Existing spillway floor

El ev

.9

S ta

.0

El ev

.0

S ta

.0

El ev

.2

S ta

.0

El ev

.2

S ta

.0

El ev

.6

S ta

.0

El ev

.0

S ta

.0

El ev

.0

S ta

.0

El ev

.5

S ta

.0

El ev

.7

S ta

.5

Panels 1 to 7 Panels 8 to 14 Panels 15 to 21 Panels 22 to 28

Panels 29 to 35

Panels 36 to 42

Panels 43 to 49

Panels 50 to 56

Limits of Floor Repairs

(see Drawing No. 60064)

60076

60076

EL

EV

A

TI

O N

STATION

12+00 12+20

60076

GENERAL NOTES

1. Dimensions of repair areas are based on previous investigations as recent as 2021, and will be field adjusted as needed by the Contracting Officer's Representative.

2. Existing concrete shall be clean and saturated surface dry prior to installing replacement concrete.

3. Replacement concrete shall be finished to provide a smooth surface that is even with the existing concrete, and to the original lines and grades as shown on Drawing Nos. 328-D-738 and -739.

LEGEND

Concrete Repairs

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway

Site Plan 328-600-60063 Floor Repair - General Plan 328-600-60064 Wall Repair - Details 328-600-60076 Plan and Sections 328-D-580 Walls - Plan, Elevation and Sections 328-D-738 and -739 Walls - Sta. 10+80 to Sta. 13+12 - Reinforcement 328-D-746, -747, -750, and -754

LEFT SPILLWAY WALL PROFILE

0 10' 20'

RIGHT SPILLWAY WALL PROFILE

0 10' 20'

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

WALL REPAIR

PROFILE

BILLINGS, MT

328-600-60075

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Enzenbacher, Dominick R

Enzenbacher, Dominick R

Lowe, Nathan J

Lowe, Nathan J P.E.

Skinner, Norris (David)

R

EV

N O 1

C O

N C R

ET

E C O

A

TI

N G

R

EM

O V

ED

AutoCAD SHX Text

ALWAYS THINK

Sta. 12+45.25 Contraction Joint

4'-4" (see Note 4)

1'

4' -8

(s ee N ot e

4)

2'-5" (see Note 4)

3' se e

N ot e 4)

LEFT WALL REPAIR DETAIL

60075

Station 12+45

90°

90°

1'

1'-7" (see Note 4)

B

C

10°

Repair SectionC Station 12+45

Sta. 12+45.25 Contraction Joint

2" Sawcut & core (see Note 3, typ.)

10°

Corner cores

Reinf. not shown

FLOW

Sta. 12+06.50 Contraction Joint

1'

2'-6" (see Note 4)

B

2' se e

N ot e 4)

2' -6

(s ee N ot e

4)

A

6" (see Note 5)

10°

Corner core

LEFT WALL REPAIR DETAIL

60075

Station 12+08

REPAIR SECTIONA Station 12+08

REPAIR SECTIONB Stations 12+08 and 12+45

90°

Sta. 12+06.50 Contraction Joint

2" Sawcut & core (see Note 3, typ.)

#5@12" o.c.e.w.

(see Note 2)

See Note 7

See Note 6

2" Sawcut

2'-4" (see Note 4)

Reinf. not shownFLOW

9"

9"

3"12"

Sta. 12+06.50 Contraction Joint

℄ Embedded guardrail post (see Note 8)

REPAIR SECTIOND Station 12+06.5

RIGHT WALL REPAIR DETAIL

60075

Station 12+06.5

D

1/4" Batter

FLOW

12"12"

3/8" Batter

Corner core

E

2" Sawcut (typ.)

6"

Corner core

REPAIR SECTIONE Station 12+06.5

Reinf. not shown

1' -3

See Note 9

See Note 2 (typ.)

Repair Station Core Drill Holes (EA)

Saw Cut Length (LF) Area (SF) Est. Volume

(CY)

12+08 (Left Wall) 1 5.5 5.9 0.11

12+06.5 (Right Wall) 4 8.2 2.4 0.09

12+45 (Left Wall) 2 13.8 19.7 0.36

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway

Wall Repair - Profile 328-600-60075 Walls - Sta. 10+80 to Sta. 13+40 - Plan, Elevation, and Sections 328-D-738 and -739 Walls - Sta. 10+80 to Sta. 13+68 - Reinforcement 328-D-726, -746, -747, -750, -754, -768, -779, -781, -783, and -798 Handrail 328-D-775

NOTES

1. For general concrete outline notes, refer to Drawing No. 328-600-60075.

2. Preserve existing reinforcement per Specifications.

3. Depth of existing reinforcement (where present) is assumed to be 3 inches. Sawcut and drill cores around repair perimeters to a maximum depth of 2 inches.

4. Where existing reinforcement is exposed by concrete removal, adjust location of repair edge as necessary to provide a minimum clear distance of 1.5 times the new concrete's maximum aggregate size behind existing reinforcement.

5. Remove spillway wall concrete to a depth of (a) 6 inches from the existing surface, OR (b) 1.5 times the maximum aggregate size of new concrete below existing reinforcement (where present), OR (c) to sound concrete as determined by COR, whichever is greater.

6. Clean and dry existing concrete to saturated surface dry condition prior to installing replacement concrete.

7. Finish new concrete to provide a smooth, even surface and a flush interface with the existing concrete. Unless otherwise noted, match original lines and grades.

8. Remove, form, and replace concrete around existing embedded guardrail post. Slope surface to drain away from base of post.

9. Chamfer all exposed corners 3/4" unless specified otherwise.

LEGEND

Saw cut

Normal concrete removal

Existing reinforcement

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

WALL REPAIR

DETAILS

BILLINGS, MT

328-600-60076

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Enzenbacher, Dominick R

Enzenbacher, Dominick R

Lowe, Nathan J

Lowe, Nathan J P.E.

Skinner, Norris (David)

R

EV

N O 1

C O

N C R

ET

E C O

A

TI

N G

R

EM

O V

ED

AutoCAD SHX Text

ALWAYS THINK

A

Pier 2 Pier 3

SPILLWAY BRIDGE DOWNSTREAM ELEVATION

0 10' 20'

El. 2415.83

El. 2411.00

El. 2369.71

Crest El. 2366.10

Crest El. 2386.20

S pi llw ay

El. 2380.0±

2 2

PIER PROFILEA

14.0'

FLOW

18.1'

Bridge ℄

0 10' 20'

Cap repair on Pier 2 only

Coat exposed portions of front face

1'-6"

6"

D

3" clr.(typ.)

3.

5" c lr

6"

1'-3"

C

PIER 2 CAP REPAIR1 Downstream Elevation

1' 2'0

3" clr. 9"

CrJ

2" Sawcut (typ.)

FLOW

FL

O

W

REPAIR SECTIOND 1' 2'0

REPAIR SECTIONC 1' 2'0

Corner core Corner core

#8 bars (typ.)

PIER 2 BASE REPAIR2 Downstream Elevation

1' 2'0

8" (typ.) 3" clr. (typ.)

#8 bars (typ.)

2' -6

6" (s ee N ot e 1

2" Sawcut (typ.)

F

FLOW

E 2'-6"

(t yp

#8 bars (typ.)

12" (typ.)

FL

O

W

4'-0"

Pier 3 - Oposite Hand

REPAIR SECTIONE

1' 2'0

REPAIR SECTIONF

1' 2'0

Corner core

4'

Spillway floor

6"6"

18"x18" Chamfer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0-

7-

R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

BRIDGE PIER CONCRETE

REPAIRS

PLAN, PROFILES, AND

SECTIONS

BILLINGS, MT

328-600-60077

2023-01-20

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

£TT£

£AT£

£AA£

£TA£

Lowe, Nathan J

Lowe, Nathan J

Enzenbacher, Dominick R

Lowe, Nathan J P.E.

Skinner, Norris (David)

Civil Engineer

NOTES

1. Remove and replace damaged concrete to specified depth. Continue pier base removal to 6" below spillway floor grade.

2. For general concrete outline and reinforcement notes, see Standard

Drawings 40-D-60003 and 40-D-60004.

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway

Site Plan 328-600-60063 Crest and Piers - Plan, Elevation and Sections 328-D-748 Bridge - Plan and Sections 328-D-759 Bridge Piers - Reinforcement 328-D-762 Bridge Piers - Reinforcement Bar List 328-D-774

LEGEND

Saw cut

Normal concrete removal

Existing reinforcement

R

EV

N O

¦R_DT¦ £RA£

C O

N C R

ET

E C O

A

TI

N G

R

EM

O V

ED

6"

6' -6

S ta

8+

.7

S ta

8+

.6

S ta

9+

.6

S ta

9+

.0

S ta

9+

.0

5' -4

A

8'-0"

EJ CrJ CrJ

1' -0

2 3

Dimensions Symmetrical about ℄

Remove and dispose of existing security fencing

Remove and dispose of existing metal cover

1" Flex conduit (see Note 1)

1/2" Rigid conduit (see Note 1)

1-1/2" Rigid conduit (see Note 1)

Remove and dispose of existing rigid conduit

Mounted sign (see Note 1)

2' -0

Outlet works control house

1' -0

"1' -0

C

B

4' -0

Exist. 6" Rubber waterstop

Exist. 6" Metal sealing strip

Sawcut normal to top face

Exist. metal cover

Existing security fencing

PVC retro-fit waterstop and joint filler

PVC waterstop

PVC retro-fit waterstop

Core 2"Ø holes at corners (typ.

both sides)

See Note 7

12 5/8"

See Note 3

12" 3" clr. (typ.)

#5@12"

#6@12" (offset 6")

#5 bars (typ.)

3/4" Chamfer (typ.)

6"

2" Sawcut (typ.)

10 3/4"

See Note 3

3" clr. (typ.)

2" Sawcut (typ.)

#5@12"

#6@12" (offset 6")

#5 bars (typ.)

Top of exist. wall 12"

3/4" Chamfer (typ.)

13 1/4"

6"

#5@12" (offset 6")

9"

#5@12"

6" 9"

Lap splices per Standard Dwg.

40-D-60004 (typ.)

PVC Retro-fit waterstop system (see Note 4)

3/4" Chamfer (typ.)

Existing 6" rubber waterstop

(see Note 4) 5"

6"

#5 bars (typ.)

Joint filler (see Note 5)

3" clr. (typ.)

3"

Existing metal sealing strip/ New PVC waterstop (see Note 4)

6"

6"

6"

6"6" #5@12"

Existing metal sealing strip

6" #5@12"

3"

PVC Retro-fit waterstop system (see Note 4)

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0-

8-

R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

O U

TL

ET

W O

R K S

STILLING BASIN WALL

REPAIR

PLAN, PROFILE,

SECTIONS, AND DETAILS

BILLINGS, MT

328-600-60078

2023-01-20

NOTES

1. Prior to construction and wherever possible, remove existing features that may impede concrete removal and placement, and re-install them afterwards at original locations.

2. Remove all damaged concrete.

3. Match existing batter (5/8" per foot) on outer faces.

4. Remove exposed portions of existing rubber waterstop or

6" metal sealing strip and install PVC waterstop to 6" below new top of wall.

5. Remove and replace existing 3/4" preformed joint filler, extending it to new top of wall.

6. For general concrete outline and reinforcement notes, see Standard Drawings 40-D-60003 and 40-D-60004.

PROFILEA

PLAN

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

£TT£

£AT£

£AA£

£TA£

Carter, Amy J

Lowe, Nathan J

Enzenbacher, Dominick R

Lowe, Nathan J P.E.

Skinner, Norris (David)

Civil Engineer

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway - Site Plan 328-600-60063 Medicine Creek Dam - Outlet Works

Control House 328-D-433 Stilling Basin 328-D-436 Stilling Basin - Reinforcement 328-D-437 and -518 Reinforcement List 328-BM-D-437

General Notes for Concrete Outline and Reinforcement 40-D-60003 Minimum Requirements for Detailing Reinforcement 40-D-60004

LEGEND

Remove

New

Existing reinforcement

New reinforcement

WALL SECTIONB Sta. 8+57.77 to Sta. 9+19.69

0 5' 10'

0 5' 10'

0 6" 12"

WALL SECTIONC Sta. 9+19.69 to Sta. 9+50.00

0 6" 12"

Left Wall (Right Wall mirrored)

0 6" 12"

EXPANSION JOINT DETAIL1 Sta. 8+57.77

0 6" 12"

CONTRACTION JOINT DETAIL2 Sta. 8+88.69

0 6" 12"

CONTRACTION JOINT DETAIL3 Sta. 9+19.69

#5@12"

Left Wall (Right Wall mirrored)

#5@12"

#5@12"

#5@12"

Left Wall (Right Wall mirrored)

Left Wall (Right Wall mirrored) Left Wall (Right Wall mirrored)

R

EV

N O 1

C O

N C R

ET

E C O

A

TI

N G

R

EM

O V

ED

AutoCAD SHX Text

ALWAYS THINK

A

TI

O N

STATION

1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 11+50

V

PI

S ta

1+

El

.9

V

PI

S ta

2+

.6

El

.9

V

PI

S ta

3+

.3

El

.7

V

PI

S ta

4+

.0

El

.7

V

PI

S ta

5+

.3

El

.0

V

PI

S ta

El

.5

S=0.00557 S=-0.04772

S=0.02891 S=0.01338 S=0.08206

℄ Culverts (see 60082)

℄ Exist. Access Road 2 ℄ Exist. Access Road 1

EL

EV

A

TI

O N

STATION

15+00 16+00 17+00 18+00 18+88

EL

EV

A

TI

O N

STATION

15+00 16+00 17+00 18+00 18+88

S=-0.04495 S=-0.07535 S=-0.01597S=0.01485 S=0.02926

V

PI

S ta

El

.1

V

PI

S ta

.1

El

.5

V

PI

S ta

.3

El

.1

V

PI

S ta

.8

El

.5

V

PI

S ta

.8

El

.6

V

PI

S ta

.7

El

.5

℄ New Access Road EL

EV

A

TI

O N

STATION

20+00 21+00 22+0022+12

V

PI

S ta

El

.0

V

PI

S ta

.5

El

.9

V

PI

S ta

.8

El

.5

V

PI

S ta

.5

El

.6

V

PI

S ta

.1

El

.0

V

PI

S ta

.2

El

.0

V

PI

S ta

.6

El

.4

V

PI

S ta

.3

El

.2

V

PI

S ta

.7

El

.6

℄ New Access Road

Line Table: Alignments

Line #

L1

L2

L3

L4

L5

L6

Length

100.21

250.00

699.79

42.34

39.97

29.44

Direction

N64° 15' 11.55"E

N53° 46' 12.72"E

N61° 35' 04.79"E

S47° 04' 06.40"E

S51° 01' 02.79"E

S46° 35' 52.59"E

Line Table: Alignments

Line #

L7

L8

L9

L10

L11

Length

38.97

39.76

39.22

29.02

29.34

Direction

S42° 13' 15.69"E

S35° 59' 45.45"E

S71° 04' 01.36"E

S77° 11' 30.46"E

S73° 32' 55.55"E

95 230023

231823

231023

232324

15+00

16+00

17+00

18+00 22+12

20+00

+00

22+00

15 23

23112311

19 23

L1

L4 L5

L6 L7

L8

L9

L10

L11

L2

2326 2327 2328

N197951.75 E1579357.09

N198186.06 E1579482.54

N198315.36 E1579477.74

L3

22 2323

PI

PI

1+

2+ 00 3+

00 4+

5+

6+

7+

8+

9+

0 40' 80'20'

ACCESS ROADS - PLAN

NEW ACCESS ROAD - PROFILE

0 40' 80'20'

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway and Outlet Works Concrete Repairs

Access Road - Site Plan 328-600-60079 Access Road - Sections 328-600-60081

EXISTING ACCESS ROAD 1 - PROFILE

0 40' 80'20'

EXISTING ACCESS ROAD 2 - PROFILE

0 40' 80'20'

℄ Existing Access Road 1

℄ Existing Access Road 2

℄ New Access Road

XXXX

LEGEND

Existing Contour

Proposed Contour

Existing Grade

Final Grade

Gravel Surfacing

Riprap

Grouted Riprap

XXXX

NOTES

1. Horizontal locations are based on the North American Datum of 1983 (NAD 83) Nebraska State Plane coordinate system. Topography is referenced from a local datum on the dam embankment, which is based on the North American Vertical Datum of 1988 (NAVD 88).

2. Northings, eastings, and distances provided for alignments are given in U.S. feet, and bearings are based on NAD 83 Nebraska State Plane coordinates.

3. Replace topsoil over disturbed areas not covered by gravel surfacing, and reseed.

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

ACCESS ROAD

PLAN AND PROFILES

BILLINGS, MT

328-600-60080

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Carter, Amy J

Walsh, Christie S

Lowe, Nathan J

Lowe, Nathan J

Skinner, Norris (David)

See Note 2

Skinner, Norris (David) ivi n ineer o e, Na an e e a s e d

A

TI

O N

OFFSET

Sta. 2+15.97

0 10 20 30 400-10-20-30-40

2.0' (See Note 1, typ.)

El. 2303.0 El. 2303.0

Match existing grade

See Note 2 (typ.)

Limits of excavation (typ.)

Geotextile to bottom of slope (typ.)

1:1 (m ax., typ.)

Replace topsoil and reseed above El. 2303.0 (typ.)

EL

EV

A

TI

O N

OFFSET

Sta. 2+39.98

0 10 20 30 400-10-20-30-40

2:1

Existing grade

Final grade

El. 2293.8

18.0'

Inv. El. 2295.3

El. 2303.0

El. 2295.8

2:1

1.0'

1.

0'

2.0'

2.

0'

R ip ra p

1:1 (m ax.)

Slope varies

Geotextile

Limits of excavation

EL

EV

A

TI

O N

STATION

2+15 2+20 2+30 2+40 2+50 2+60 2+70 2+80 2+90 3+00 3+10 3+20 3+30 3+40 3+50

25.0' Riprap 25.0' Riprap81.8' Culvert

El. 2303.0 El. 2303.0

2:1 (typ.)

2.0' (See Note 1)See Note 2 (typ.)

Limits of excavation (typ.)

Geotextile to bottom of slope (typ.)

Match existing grade

Sta. 2+41.60 El. 2293.80

Sta. 2+43.60 El. 2294.80

S ta

2+

.6

El

.8

Sta. 3+19.37 El. 2294.80 Sta. 3+21.37

El. 2293.80

S ta

3+

.3

El

.7

Sta. 2+40.60 Inv. 2295.30 Sta. 3+22.37

Inv. 2295.30 Match existing grade

2:1 (ty p.)

2.0' (See Note 1)

S=0.00

6"

103"x71" CMP per ASTM A760

2.

5'

OUTLET WORKS CHANNEL SECTION

60082

A Sta. 2+15.60

OUTLET WORKS CHANNEL SECTION

60082

B Sta. 2+40.60

LEGEND

Existing Grade

Limits of Excavation

Final Grade

Geotextile

Subgrade

TYPICAL UPPER KEY FOR GEOTEXTILE

Not to Scale

0 10'5'

0 10'5'

CULVERT PROFILE

60082

0 10'5'

REFERENCE DRAWINGS

Medicine Creek Dam - Spillway and Outlet Works Concrete Repairs

Access Road - Outlet Works Channel Plan and Profile 328-600-60082

NOTES

1. Measure riprap thickness vertically from the excavation surface.

2. Place CLSM within voids throughout invert riprap until flush with top of riprap.

Compacted Backfill

Topsoil

Riprap

Grouted Riprap

Controlled Low-Strength Material (CLSM)

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

8-

0- T1

-M X -0

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

A

LS

H

¦D_DT¦

¦STATUS¦

PI

C K -S

LO

A N

M

IS

S O

U R I

B A S

IN

P R O

G R A M

FR

EN

C H

M A N

-C A M

B R

ID

G E

D

IV

IS

IO

N

M

ED

IC

IN

E C R

EE

K D

A M

S

PI

LL

W

A Y

ACCESS ROAD

CULVERT PROFILE,

SECTIONS, AND DETAILS

BILLINGS, MT

328-600-60083

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

Carter, Amy J

Lowe, Nathan J

Lowe, Nathan J

Lowe, Nathan J

Skinner, Norris (David)Skinner, Norris (David) ivi n ineer o e, Na an e e a s e d

Medicine Creek Dam Concrete Repair and Access Improvement

Photographs 51 03 30 - 2

Figure 1. View of Medicine Creek Dam Spillway facing upstream (north) from the right side of the downstream channel. April 14, 2021

51 03 30 - 6

Figure 5. View of concrete damage and exposed waterstop or sealant along a longitudinal joint.

April 14, 2021

51 03 30 - 8

Figure 7. View of the spillway notch, facing upstream. Note that water seeps from the transverse joint at the base of the crest structure. Water stains along the side of the notch are a result of leakage past the flash boards on its crest, which will not be an issue during construction.

April 14, 2021

51 03 30 - 9

Figure 8. View of drainage through the left wall of the spillway chute and stilling basin. Similar drainage emanates from a drain on the right wall. April 14, 2021

51 03 30 - 28

Figure 27. View of the right wall of the outlet works stilling basin. The top 24 inches of both walls are to be removed and replaced, and between the outlet works house and the second contraction joint they are to be raised two feet. April 14, 2021

51 03 30 - 32

Figure 31. View facing east from the top of bank on the right side of the outlet works channel at the location of the new crossing. March 30, 2022

51 03 30 - 34

Figure 33. View facing downstream (southeast) along the outlet works channel from the location of the new crossing. March 30, 2022

END OF SECTION

Medicine Creek Dam Sources Sought Notice 5-7-2024
Selcted Drawings for Sources Sought
328-600-T12402-RD-1
328-600-60064-RD-1
328-600-60065-RD-1
328-600-60075-RD-1
Sheets and Views
328-600-60075-RD-1
328-600-60076-RD-1
Sheets and Views
328-600-60076-RD-1
328-600-60077-RD-1
Sheets and Views
328-600-60077-RD-1
328-600-60078-RD-1
Sheets and Views
328-600-60078-RD-1
328-600-60080-RD-1
328-600-60083-RD-1

Selcted Photographs for Sources Sought

File details come from the government source that posted it. Updated .