This engineering drawing is a detailed cross-section diagram for the 2022 Boulder City Fiber Cable Upgrades project by the Bureau of Reclamation, located in Boulder City, Nevada. The drawing (Project Number 45-301-T765) shows a proposed telecommunications conduit installation across Colorado Street, featuring precise technical specifications including:

The cross-section details multiple underground utility placements, including 4-3" PVC conduits embedded in flowable concrete, a 20" BC water line, and a 2½" sewer pipe. The design includes specific dimensional requirements for trench depth, conduit placement, and surface restoration, with notes indicating that restoration limits will be determined by the City of Boulder City. The drawing references Uniform Standard Drawings for Clark County and includes provisions for removing and replacing existing asphalt concrete pavement while matching existing depth, and installing a #4 bare copper wire alongside the new conduits.

View the file

Other files

File Type Posted
Dwg_45-301-T760_Site_Plan_0001.pdf PDF
Dwg_45-301-T761_Detail_Sheet_1_0001.pdf PDF
Sol_140R3025Q0024_Amd_0001.pdf PDF
Statement_of_Work_Subsurface_Utility_Investigations.doc DOC document
Combined_Synopsis.docx DOCX document
Sol_140R3025Q0024.pdf PDF
Wage_Determination_2015-5593.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0+

0+

0+

0+

0+

0+

0+

0+

0+

ELEV 100

ELEV 95

LOOKING

WEST

CL

EXISTING

CURB EXISTING

PAVEMENT

21" SNWA PIPE

@STA 20+47 +/-

4-3" PVC CONDUITS

IN FLOWABLE CONCRETE

20" BC WATER LINE

3' M

IN

M

IN

1' -4

M

IN

A

A

10" WATER

3'-0" *

2'-6"

0'-3" 0'-2"

0'-3" 0'-3"

#4 BARE

COPPER WIRE

REMOVE AND REPLACE

EXISTING A.C

MATCH EXISTING DEPTH

(PLUS 1 INCH)

2'-0" MIN

TYP.

0'-3"

EXISTING

AGGREGATE BASE

PRIME COAT PER

SECTION 408

MILL AND OVERLAY

RESTORATION LIMITS TO BE

DETERMINED BY CITY OF BOULDER CITY

REFER TO UNIFORM STANDARD

DRAWINGS FOR CLARK COUNTY

DRAWINGS 500 SERIES

4-3 INCH

NEW CONDUITS

CLSM

FLOWABLE CONCRETE

Fo r

In te rn al

U se

O nl y D ra ft

N ot F or D is tr ib ut io n

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-3

-T

7- R D

-1 R

EV

.D

W G

LA

S T

S A V

ED

D A

TE

-0 7-

LA

S T

S A V

ED

B Y

JS

W

A

TZ

EL

L

¦D_DT¦

¦STATUS¦

B O

U

LD

ER

C

A N

YO

N

P R O

JE

C T

B O

U

LD

ER

C

IT

Y, N V

B O

U

LD

ER

C

IT

Y

TE

LE

PH

O

N E

LI

N

E

B

O U

LD

ER

C

IT

Y

FI

B

ER

C A B

LE

U

PG

R A D

ES

PR

O

JE

C T

CROSS SECTION ON

COLORADO STREET

BOULDER CITY, NV

45-301-T765

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

KMM

FPB

KMM

JO

SUPERVISORY GENERAL ENGINEER

CCV

SUPERVISORY CIVIL ENGINEER

SECTION B-B CROSSING COLORADO STREET FOR TELECOMMUNICATION CONDUITS

SCALE: 1" = 2'

SECTION A-A OF TELECOMM CONDUITS TRENCH

SCALE: 1" - 1'

CROSSING COLORADO STREET

* FIELD VERIFY DIMENSION

File details come from the government source that posted it. Updated .