This document is a Statement of Work (SOW) for a federal contract opportunity. The Bureau of Reclamation, Davis Dam and Power Plant, has a requirement for two (2) direct drive rotary-screw air compressors and one (1) 1000 CFM desiccant air dryer. The compressors and dryer must meet specific salient characteristics and be able to maintain a modulating, rotating lead/lag configuration to provide service air throughout the Davis Dam Power Plant. The vendor awarded the contract must deliver the approved equipment, provide factory-trained technician support for programming and commissioning, and any necessary training. Delivery is required approximately 45 days after award to the Davis Dam location in Bullhead City, Arizona. The North American Industry Classification System (NAICS) code for this acquisition is 333912 Air and Gas Compressor Manufacturing. The solicitation number is 140R3024Q0119 and offers are due by September 10, 2024.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 – Statement of Work
(SOW)
Document No.
140R3024Q0119
Document Title
Davis Dam Station Service Air Compressors 1 of 1
Attachment 1 – Statement of Work
Davis Dam Station Service Air Compressors and Air Dryer
1.0 Background
The Bureau of Reclamation, Davis Dam and Power Plant located on Davis Dam Rd. Bullhead City
Arizona has a requirement for two (2) Direct Drive Rotary Air Compressors, one (1) 1000 CFM
Desiccant Air Dryer. These air compressors will work in a modulating, rotating lead lag configuration to provide all service air to the Davis Dam Power Plant and auxiliary equipment. The Davis power plant existing compressors have reached their end of life. The Davis Station Service Air System supplies air throughout the plant, to include generator condensing operations, pneumatic valve operation, and generator auxiliary equipment operation. Davis also uses large volumes of air during the year in support of sandblasting operation for cavitation repair, gate overhauls and penstock rehabilitation.
2.0 Scope of Work
This is a requirement for two (2) identical direct drive rotary-screw compressors fixed speed and one (1)
1000 CFM Desiccant Air Dryer. The compressors and dryers must meet the salient characteristics and be able to maintain a modulating, rotating LEAD/LAG configuration. Shipping to Davis Dam Field
Division included.
3.0 Term of the Contract.
Vendor that is awarded this contract must deliver an approved rotary-screw compressors, dryer, materials, and spare parts that meet all requirements listed in this solicitation to Davis Dam, a factory trained technician to provide WS controller lead/ lag programming at time of commissioning, and any necessary training to constitute acceptable fulfillment of this requirement.
4.0 Facilities Location.
1 Davis Dam Road Bullhead City, AZ 86429-9707
5.0 Facility Hours of Operation.
Facility receiving hours are 7:30 A.M. to 4:00 P.M. PT. Monday through Thursday. All receiving hours listed exclude weekends and federal holidays.
6.0 Equipment Information.
See Required Salient Characteristics for equipment specifications.