This document provides technical specifications and installation details for a metal roofing system. It includes drawings and part numbers for various roof components like eave plates, gutter systems, ridge and hip flashing, closure details, and fastener patterns. The specifications cover material requirements and installation procedures for a Mirage II standing seam metal roof across different roof configurations, such as simple eaves, eaves with gutters, rake start and end details, and tie-in details. This level of technical specification and drawing appears to support a solicitation for roof repair services included to replace or repair an existing Mirage II metal roof system. The related federal contract opportunity is for roof repairs at an unnamed facility for the Department of the Interior Bureau of Reclamation, but no further details are provided on response dates, award timing, or pricing requirements.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TABLE OF CONTENTS
A-1
PAGE NUMBER: DETAIL DESCRIPTION
A-1........................................TABLE OF CONTENTS
A-2........................................GENERAL NOTES
B-1.........................................FASTENER PATTERN
B-2.........................................GENERAL INFORMATION
C-1.........................................SIMPLE EAVE DETAIL
C-2.........................................EAVE with 5" GUTTER DETAIL
C-3.........................................SCULPTURED EAVE DETAIL
C-4.........................................HIGH-SIDE EAVE DETAIL (5" BARGE)
C-5.........................................RAKE START DETAIL (5" BARGE)
C-6.........................................RAKE END DETAIL (5" BARGE)
C-7.........................................EAVE w/ 7" GUTTER DETAIL
C-8.........................................HIGH-SIDE EAVE DETAIL (7" BARGE)
C-9.........................................RAKE START DETAIL (7" BARGE)
C-10.......................................RAKE END DETAIL (7" BARGE)
C-11.......................................RAKE START TIE-IN DETAIL
C-12.......................................RAKE END TIE-IN DETAIL
C-13.......................................HIGH-SIDE TIE-IN DETAIL
C-14.......................................FLOATING RIDGE DETAIL
C-15.......................................FIXED RIDGE DETAIL
C-16.......................................FLOATING HIP DETAIL
C-17.......................................FIXED HIP DETAIL
C-18.......................................SIDE-LAP DETAIL
C-19.......................................BARGE TRIM LAPS
GENERAL NOTES
A-2
The details shown on the following pages are suggestions or guidelines for installing the Mirage II roof panel system. The installation details shown here are proven methods of construction, but they are not intended to cover all building requirements, designs or codes. The details may require changes or revisions due to individual project conditions.
Installation procedures shall be in accordance with the manufacturer's printed instructions, details or approved shop drawings. Installers should thoroughly familiarize themselves with all instructions prior to beginning the installation process.
The designer/installer is responsible to ensure the following:
That the details here meet the particular building requirements.
Awareness of and allowance for expansion/contraction of the roof panels.
That adequate water tightness is maintained.
That a proper uniform substructure is used to avoid panel distortion and that the substructure meets necessary code requirements.
That all supporting members have been examined and are straight, level and plumb.
McElroy Metal can provide all flashings and accessories shown in the installation drawings unless noted otherwise. Panels, flashing and trim shall be installed true and in proper alignment with any exposed fasteners equally spaced for the best appearance. Sealant shall be field applied on a clean, dry surface.
Some field cutting and fitting of panels and flashings is to be expected and to be considered a part of normal installation work. Workmanship shall be of the best industry standards and with installation performed by experienced metal craftsmen.
Oil canning of metal panels is in the product and is not a cause for rejection. Striated panels are recommended as they reduce the appearance of oil canning.
Contents of this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy Metal's website at www.mcelroymetal.com.
http://www.mcelroymetal.com./
GENERAL INFORMATION
B-1
FASTENER PATTERNS
1/4-14 X 1 1/4" TEK2 ZAC
FASTENERS
GENERAL INFORMATION
B-2
PANEL FOLDING
SIMPLE EAVE DETAIL
NOTES: 1. Eave Plate to run from steel line to steel line. Attach to Eave Structural Member with
2. Simple Eave Trim to run from out of wall to out of wall. Attach to Eave Plate with #10-16 x 1" Pancake
EAVE TRIM
C-1
3. Install Inside Closure with continuous run of 1" Roll Tape Sealant on bottom and Butyl Tube Sealant
4. Attach roof panel to Eave Plate with 1/4-14 x 1 1/4" TEK2 ZAC. Fasteners must penetrate sealant.
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SIMPLE EAVE
TRIM
EAVE STRUCTURAL
MEMBER
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
ROOF LINE
UTILITY EAVE
PLATE
OUTSIDE CLOSURE
(RECOMMENDED)
MIRAGE II
PANEL
WALL PANEL
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
SIMPLE EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE)
EAVE STRUCTURAL
MEMBER
UTILITY EAVE
PLATE
MIRAGE II
PANEL
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
OUTSIDE CLOSURE
(RECOMMENDED)
BUYTL TUBE SEALANT
(TOP OF CLOSURE)
FIELD FORM
DRIP EDGE
FIELD FORM
DRIP EDGE
5. Field form Drip Edge on panel using panel bending tool.
Head Fasteners at 5'-0" O.C.
#10-16 x 1" Pancake Head Fasteners at 1'-0" O.C.
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/ 1" ROLL TAPE
SEALANT (BOTTOM OF CLOSURE
& BUTYL TUBE SEALANT
(TOP OF CLOSURE)
on top.
EAVE w/ 5" GUTTER DETAIL
2. Simple Eave Trim to run from out of wall to out of wall. Attach to Eave Plate with #10-16 x 1"
EAVE TRIM
C-2
3. Install Inside Closure with continuous run of 1" Roll Tape Sealant on bottom and Butyl Tube Sealant
4. Attach roof panel to Eave Plate with 1/4-14 x 1 1/4" TEK2 ZAC. Fasteners must penetrate sealant.
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SIMPLE EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE) &
BUTYL TUBE SEALANT
(TOP OF CLOSURE)
EAVE STRUCTURAL
MEMBER
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
ROOF LINE
UTILITY EAVE
PLATE
OUTSIDE CLOSURE
(RECOMMENDED)
MIRAGE II
PANEL
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SIMPLE EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE)
EAVE STRUCTURAL
MEMBER
UTILITY EAVE
PLATE
MIRAGE II
PANEL
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
OUTSIDE CLOSURE
(RECOMMENDED)
BUTYL TUBE SEALANT
(TOP OF CLOSURE)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (1 PER STRAP)
GUTTER STRAP
(@ EVERY OTHER SEAM)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (2 PER PANEL)
GUTTER
5. Gutter straps are to be placed between the two roof sheets and in line from end to end as show.
NOTE: SLIDING SNOW AND ICE COULD
CAUSE DAMAGE TO GUTTER SYSTEM.
6. The gutter is not required to be fastened to the gutter straps on pitches less than 2:12.
GUTTER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (2 PER PANEL)
GUTTER STRAP
(@ EVERY OTHER SEAM)
GUTTER
#10-16 x 1" Pancake Head Fasteners at 1'-0" O.C.
Pancake Head Fasteners at 5'-0" O.C.
DOWNSPOUT
SCULPTURED EAVE DETAIL
SCULPTURED EAVE TRIM
C-3
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SCULPTURED EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE PAGE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE) &
BUYTL TUBE SEALANT
(TOP OF CLOSURE)
EAVE STRUCTURAL
MEMBER
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
ROOF LINE
UTILITY EAVE
PLATE
OUTSIDE CLOSURE
(RECOMMENDED)
MIRAGE II
PANEL
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SCULPTURED EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE PAGE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE)
EAVE STRUCTURAL
MEMBER
UTILITY EAVE
PLATE
MIRAGE II
PANEL
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
OUTSIDE CLOSURE
(RECOMMENDED)
BUTYL TUBE SEALANT
(TOP OF CLOSURE)
FIELD FORMED
DRIP EDGE
FIELD FORMED
DRIP EDGE
NOTES: 1. Eave Plate to run from steel line to steel line. Attach to Eave Structural Member with
2. Sculptured Eave Trim to run from out of wall to out of wall. Attach to Eave Plate with #10-16 x 1"
3. Install Inside Closure with continuous run of 1" Roll Tape Sealant on bottom and Butyl Tube Sealant
4. Attach roof panel to Eave Plate with 1/4-14 x 1 1/4" TEK2 ZAC. Fasteners must penetrate sealant.
5. Field form Drip Edge on panel using panel bending tool.
Pancake Head Fasteners at 5'-0" O.C.
#10-16 x 1" Pancake Head Fasteners at 1'-0" O.C.
HIGH-SIDE EAVE DETAIL - 5" BARGE
BARGE TRIM
C-4
WALL PANEL
EAVE STRUCTURAL
MEMBER
MIRAGE II CLIP
MIRAGE II
PANEL
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
OUTSIDE CLOSURE
(RECOMMENDED)
MIRAGE II
PANEL
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM OF CLOSURE)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ EA. PANEL RIB)
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
EAVE STRUCTURAL
MEMBER
MIRAGE II PANEL
CLIP
BARGE TRIM
(FIELD BREAK TO PITCH
AND NOTCH OUT AT RIBS)
WALL FRAMING
FASTENER
OUTSIDE CLOSURE
(RECOMMENDED)
2. Attach Barge Cleat to wall panels with 1/4-14 x 7/8" Lap Tek fasteners at each major rib.
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ EACH PANEL RIB)
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
WALL PANEL
BARGE CLEAT
*BARGE CLEAT
*BARGE CLEAT
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
BARGE TRIM
(FIELD BREAK TO PITCH
AND NOTCH OUT AT RIBS)
PAN-UP PANEL
NOTES: 1. Field form End Dam using End Dam tool.
3. Notch Barge Trim around ribs of roof panels and attach with 1/4-14 x 7/8" Lap Tek Zac at Major Ribs.
Fasteners must penetrate tape sealant.
OUTSIDE CLOSURE w/
1" ROLL TAPE SEALANT
(TOP & BOTTOM OF CLOSURE)
WALL FASTENER
RAKE START DETAIL - 5" BARGE
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Barge Cleat to wall panel at major ribs with (1) 1/4-14 x 7/8" Lap Tek fastener.
BARGE TRIM
C-5
3. Attach Barge Trim to roof panel at 1'-0" O.C. using 1/4-14 x 7/8" Lap Tek ZAC fasteners.
MIRAGE II PANEL
MIRAGE II CLIP
ROOF STRUCTURAL
MEMBER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
BARGE TRIM
RAKE ANGLE
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
*BARGE CLEAT
WALL FRAMING
FASTENER
WALL PANEL
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
(DO NOT FASTEN
THROUGH CLIP)
MIRAGE II PANEL
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
ROOF STRUCTURAL
MEMBER
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 1 1/4" HWH TEK2
FASTENER (@ EACH
STRUCTURAL MEMBER)
WALL PANEL
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
OUTSIDE CLOSURE
(RECOMMENDED)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
(DO NOT FASTEN
THROUGH CLIP)
BARGE TRIM
BARGE CLEAT
OUTSIDE CLOSURE
(RECOMMENDED)
*BARGE CLEAT
RAKE ANGLE
WALL FASTENER
1/4-14 X 1 1/4" HWH TEK2
FASTENER (@ EACH
STRUCTURAL MEMBER)
RAKE END DETAIL - 5" BARGE
C-6
MIRAGE II PANEL
MIRAGE II PANEL
CLIP
BARGE TRIM
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 1 1/4" HWH TEK2
FASTENER (1 PER CLIP)
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR
RIBS)
OUTSIDE CLOSURE
(RECOMMENDED)
RAKE ANGLE
FRAMING FASTENER
WALL PANEL
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER
MIRAGE II PANEL
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
ROOF STRUCTURAL
MEMBER
WALL PANEL
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
BARGE CLEAT
OUTSIDE CLOSURE
(RECOMMENDED)
RAKE ANGLE
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
WALL FASTENER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
(DO NOT FASTEN
THROUGH CLIP)
BARGE TRIM
FIELD CUT CLIP
AS REQUIRED
FIELD CUT CLIP
AS REQUIRED
ROOF STRUCTURAL
MEMBER
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Barge Cleat to wall panel at major ribs with (1) 1/4-14 x 7/8" Lap Tek fastener.
3. Attach Barge Trim to roof panel at 1'-0" O.C. using 1/4-14 x 7/8" Lap Tek ZAC fasteners.
BARGE CLEAT
*BARGE CLEAT
1/4-14 X 1 1/4" HWH TEK2
FASTENER (1 PER CLIP)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
(DO NOT FASTEN
THROUGH CLIP)
EAVE w/ 7" GUTTER DETAIL
2. Simple Eave Trim to run from out of wall to out of wall. Attach to Eave Plate with #10-16 x 1"
EAVE TRIM
C-7
3. Install Inside Closure with continuous run of 1" Roll Tape Sealant on bottom and Butyl Tube Sealant
4. Attach roof panel to Eave Plate with 1/4-14 x 1 1/4" TEK2 ZAC. Fasteners must penetrate sealant.
WALL PANEL
1/4-14 X 7/8" LAP TEK
(@ MAJOR RIBS)
SIMPLE EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE)
& BUTYL TUBE SEALANT
(TOP OF CLOSURE)
EAVE STRUCTURAL
MEMBER
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
ROOF LINE
UTILITY EAVE
PLATE
MIRAGE II
PANEL
WALL PANEL
SIMPLE EAVE
TRIM
1/4-14 X 1 1/4" TEK2 ZAC
FASTENER (SEE B-1
FOR FASTENER PAT.)
INSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(BOTTOM OF CLOSURE)
EAVE STRUCTURAL
MEMBER
UTILITY EAVE
PLATE
MIRAGE II
PANEL
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (@ 1'-0" O.C.)
OUTSIDE CLOSURE
(RECOMMENDED)
BUYTL TUBE SEALANT
(TOP OF CLOSURE)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (1 PER STRAP)
GUTTER STRAP
(@ EVERY OTHER SEAM)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (2 PER PANEL)
GUTTER
5. Gutter straps are to be placed between the two roof sheets and in line from end to end as show.
NOTE: SLIDING SNOW AND ICE COULD
CAUSE DAMAGE TO GUTTER SYSTEM.
6. The gutter is not required to be fastened to the gutter straps on pitches less than 2:12.
GUTTER
1/4-14 X 7/8" TEK2 ZAC
FASTENER (2 PER PANEL)
GUTTER STRAP
(@ EVERY OTHER SEAM)
GUTTER
#10-16 x 1" Pancake Head Fasteners at 1'-0" O.C.
Pancake Head Fasteners at 5'-0" O.C.
DOWNSPOUT
OUTSIDE CLOSURE
(RECOMMENDED)
HIGH-SIDE EAVE DETAIL - 7" BARGE
C-8
WALL PANEL
EAVE STRUCTURAL
MEMBER
MIRAGE II CLIP
MIRAGE II
PANEL
WALL FASTENER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
OUTSIDE CLOSURE
(RECOMMENDED)
MIRAGE II
PANEL
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM OF CLOSURE)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ EA. PANEL RIB)
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
EAVE STRUCTURAL
MEMBER
MIRAGE II PANEL
CLIP
BARGE TRIM
(FIELD BREAK TO PITCH
AND NOTCH OUT AT RIBS)
OUTSIDE CLOSURE
(RECOMMENDED)
2. Attach Barge Clip to wall panels with 1/4-14 x 7/8" Lap Tek fasteners at each major rib.
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
WALL PANEL
BARGE CLEAT
BARGE CLIP
*BARGE CLIP
1/4-14 X 7/8" LAP TEK
FASTENER (@ MAJOR RIBS)
BARGE TRIM
(FIELD BREAK TO PITCH
AND NOTCH OUT AT RIBS)
PAN-UP PANEL
NOTES: 1. Field form End Dam using End Dam tool.
3. Notch Barge Trim around ribs of roof panels and attach with 1/4-14 x 7/8" Lap Tek Zac at Major Ribs.
Fasteners must penetrate tape sealant.
OUTSIDE CLOSURE w/
1" ROLL TAPE SEALANT
(TOP & BOTTOM
OF CLOSURE)
WALL FRAMING
FASTENER
BARGE CLIP
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ EACH PANEL RIB)
RAKE START - 7" BARGE
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Barge Clip to wall panel at 5'-0" O.C. with (2) 1/4-14 x 7/8" Lap Tek fastener.
7" BARGE TRIM
C-9
3. Attach Barge Trim to roof panel at 1'-0" O.C. using 1/4-14 x 7/8" Lap Tek ZAC fasteners. **DO NOT
ATTACH TO CLIPS.**
MIRAGE II PANEL
MIRAGE II CLIP
ROOF STRUCTURAL
MEMBER
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
BARGE TRIM
RAKE ANGLE
1/4-14 X 7/8" LAP TEK
FASTENERS (2 PER CLIP
@ MAJOR RIBS)
BARGE CLIP
(@ 5'-0" O.C.)
WALL FRAMING
FASTENER
WALL PANEL
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
(DO NOT FASTEN THROUGH
TOP OF BARGE CLIP)
MIRAGE II PANEL
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER
(2 PER CLIP)
ROOF STRUCTURAL
MEMBER
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 1 1/4" HWH TEK2
FASTENERWALL PANEL
1/4-14 X 7/8" LAP TEK
FASTENER (2 PER CLIP
@ MAJOR RIBS)
FRAMING FASTENER
RAKE ANGLE
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
BARGE TRIM
BARGE CLEAT
1/4-14 X 1 1/4" HWH TEK2
FASTENER
BARGE CLIP
(@ 5'-0" O.C.)
RAKE ANGLE
BARGE CLIP
RAKE END DETAIL - 7" BARGE
7" BARGE TRIM
C-10
MIRAGE II PANEL
MIRAGE II PANEL
CLIP
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
BARGE TRIM
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 1 1/4" HWH TEK2
FASTENER
1/4-14 X 7/8" LAP TEK
FASTENER (2 PER CLIP
@ MAJOR RIBS)
RAKE ANGLE
FRAMING FASTENER
WALL PANEL
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER
MIRAGE II PANEL
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
ROOF STRUCTURAL
MEMBER
WALL PANEL
1/4-14 X 7/8" LAP TEK
FASTENER (2 PER CLIP
@ MAJOR RIBS)
BARGE CLIP
(@ 5'-0" O.C.)
FRAMING FASTENER
RAKE ANGLE
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
1/4-14 X 1 1/4" HWH TEK2
FASTENER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
BARGE TRIM
FIELD CUT CLIP
AS REQUIRED
FIELD CUT CLIP
AS REQUIRED
ROOF STRUCTURAL
MEMBER
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Barge Clip to wall panel at 5'-0" O.C. with (2) 1/4-14 x 7/8" Lap Tek fastener.
3. Attach Barge Trim to roof panel at 1'-0" O.C. using 1/4-14 x 7/8" Lap Tek ZAC fasteners.
**DO NOT ATTACH TO CLIPS.**
BARGE CLEAT
BARGE CLIP
(@ 5'-0" O.C.)
BARGE CLIP
RAKE START TIE-IN DETAIL
RAKE TIE-IN TRIM
C-11
FLEXABLE MEMBRANE
(NOT BY MCELROY)
RAKE ANGLE
1/4-14 X 1 1/4" HWH TEK2
FASTENER
ROOF STRUCTURAL
MEMBER
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
BUILDING LINE
(NOT BY MCELROY)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
*DO NOT FASTEN THRU CLIP*
RAKE TIE-IN TRIM
MIRAGE II PANEL
COUNTER FLASHING
(NOT BY MCELROY)
COUNTER FLASHING SEALANT
(NOT BY MCELROY)
COUNTER FLASHING SEALANT
(NOT BY MCELROY)
COUNTER FLASHING
(NOT BY MCELROY)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
*DO NOT FASTEN THRU CLIP*
MIRAGE II PANEL
FLEXABLE MEMBRANE
(NOT BY MCELROY)
FASTENER
(NOT BY MCELROY)
1/4-14 X 1 1/4" HWH TEK2
FASTENER
RAKE ANGLE
ROOF STRUCTURAL
MEMBER
BUILDING LINE
(NOT BY MCELROY)
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
RAKE TIE-IN TRIM
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Rake Tie-In Trim to panel rib with 1/4-14 x 7/8" Lap Tek ZAC fastener at 1'-0" O.C.
**DO NOT ATTACH TO CLIPS.**
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENERS (2 PER CLIP)
MIRAGE II CLIP
RAKE END TIE-IN DETAIL
C-12
COUNTER FLASHING SEALANT
(NOT BY MCELROY)
COUNTER FLASHING
(NOT BY MCELROY)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
MIRAGE II PANEL
FLEXABLE MEMBRANE
(NOT BY MCELROY)
FASTENER
(NOT BY MCELROY)
1/4-14 X 1 1/4" HWH TEK2
FASTENER (@ EACH
STRUCTURAL MEMBER)
RAKE ANGLE
ROOF STRUCTURAL
MEMBER
BUILDING LINE
(NOT BY MCELROY)
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
FIELD CUT CLIP
AS REQUIRED
RAKE TIE-IN TRIM
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER
FLEXABLE MEMBRANE
(NOT BY MCELROY)
RAKE ANGLE
1/4-14 X 1 1/4" HWH TEK2
FASTENER
ROOF STRUCTURAL
MEMBER
3/32" X 3/8" ROLL TAPE
SEALANT (CONT. ALONG
TOP OF PANEL RIB)
BUILDING LINE
(NOT BY MCELROY)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ 1'-0" O.C.)
RAKE TIE-IN TRIM
MIRAGE II PANEL
COUNTER FLASHING
(NOT BY MCELROY)
COUNTER FLASHING SEALANT
(NOT BY MCELROY)
RAKE TIE-IN TRIM
NOTES: 1. Place continuous run of Roll Tape Sealant on top of panel rib.
2. Install Rake Tie-In Trim to panel rib with 1/4-14 x 7/8" Lap Tek ZAC fastener at 1'-0" O.C.
**DO NOT ATTACH TO CLIPS.**
MIRAGE II CLIP
HIGH SIDE TIE-IN DETAIL
NOTES: 1. Place continuous run of 1" Roll Tape Sealant on panels where Outside Closures will be installed.
2. Install Outside Closures and place a continuous run of 1" Roll Tape along top of Outside Closures.
C-13
3. Install High Side Tie-In Trim and fasten to each panel rib with 1/4-14 x 7/8" Lap Tek ZAC fasteners.
HIGH SIDE TIE-IN TRIM
BUILDING LINE
(NOT BY MCELROY)
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ MAJOR RIBS)
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
MIRAGE II PANEL
HIGH SIDE
TIE-IN TRIM
PAN-UP PANEL
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ PANEL RIBS)
HIGH SIDE TIE-IN TRIM
MIRAGE II PANEL
ROOF STRUCTURAL
MEMBER
BUILDING LINE
(NOT BY MCELROY)
PAN-UP PANEL
FASTENER
(NOT BY MCELROY)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
COUNTER FLASHING
(NOT BY MCELROY)
COUNTER FLASHING
SEALANT
(NOT BY MCELROY)COUNTER FLASHING
(NOT BY MCELROY)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
COUNTER FLASHING
SEALANT
(NOT BY MCELROY)
ALTERNATE HIGH
SIDE TIE-IN TRIM
Fasteners must penetrate sealant.
ROOF STRUCTURAL
MEMBER
FLOATING RIDGE DETAIL
C-14
FLOATING RIDGE FLASHING
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ MAJOR RIBS)
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
MIRAGE II PANEL
FLOATING RIDGE
FLASHING
ROOF STRUCTURAL
MEMBER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ PANEL RIBS)
FLOATING RIDGE
FLASHING
MIRAGE II PANEL
ROOF STRUCTURAL
MEMBER
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
PAN-UP PANEL
PAN-UP PANEL
ALTERNATE FLOATING
RIDGE FLASHING
NOTES: 1. Place continuous run of 1" Roll Tape Sealant on panels where Outside Closures will be installed.
2. Install Outside Closures and place a continuous run of 1" Roll Tape along top of Outside Closures.
3. Install Ridge Flashing and fasten to each panel rib with 1/4-14 x 7/8" Lap Tek ZAC fasteners.
Fasteners must penetrate sealant.
FIXED RIDGE DETAIL
C-15
FIXED RIDGE FLASHING
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ MAJOR RIBS)
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
* MIRAGE II PANEL
FIXED RIDGE
FLASHING
ROOF STRUCTURAL
MEMBER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ PANEL RIBS)
FIXED RIDGE
FLASHING
MIRAGE II PANEL
ROOF STRUCTURAL
MEMBER
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
PAN-UP PANEL
PAN-UP PANEL
ALTERNATE FIXED RIDGE FLASHING
NOTES: 1. Place continuous run of 1" Roll Tape Sealant on panels where Outside Closures will be installed.
2. Install Outside Closures and place a continuous run of 1" Roll Tape along top of Outside Closures.
3. Install Ridge Flashing and fasten to each panel rib with 1/4-14 x 7/8" Lap Tek ZAC fasteners.
FLOATING HIP DETAIL
C-16
FLOATING HIP FLASHING
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ MAJOR RIBS)
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
MIRAGE II PANEL
FLOATING HIP
FLASHING
ROOF STRUCTURAL
MEMBER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ PANEL RIBS)
FLOATING HIP
FLASHING
MIRAGE II PANEL
ROOF STRUCTURAL
MEMBER
BEVELED OUTSIDE
CLOSURE W/ 1"
ROLL TAPE SEALANT
(TOP & BOTTOM)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
PAN-UP PANEL
PAN-UP PANEL
HIP FLASHING
ALTERNATE FLOATING
NOTES: 1. Place continuous run of 1" Roll Tape Sealant on panels where Outside Closures will be installed.
2. Install Outside Closures and place a continuous run of 1" Roll Tape along top of Outside Closures.
3. Install Hip Flashing and fasten to each panel rib with 1/4-14 x 7/8" Lap Tek ZAC fasteners.
FIXED HIP DETAIL
C-17
FIXED HIP FLASHING
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ MAJOR RIBS)
MIRAGE II CLIP
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
MIRAGE II PANEL
FIXED HIP
FLASHING
ROOF STRUCTURAL
MEMBER
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ PANEL RIBS)
FIXED HIP
FLASHING
MIRAGE II PANEL
ROOF STRUCTURAL
MEMBER
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
OUTSIDE CLOSURE W/
1" ROLL TAPE SEALANT
(TOP & BOTTOM)
PAN-UP PANEL
PAN-UP PANEL
ALTERNATE FIXED HIP FLASHING
NOTES: 1. Place continuous run of 1" Roll Tape Sealant on panels where Outside Closures will be installed.
2. Install Outside Closures and place a continuous run of 1" Roll Tape along top of Outside Closures.
3. Install Hip Flashing and fasten to each panel rib with 1/4-14 x 7/8" Lap Tek ZAC fasteners.
SIDE LAP DETAIL
C-18
MIRAGE II
PANEL
FACTORY APPLIED
SEAM SEALANT
MIRAGE II
CLIP
PANCAKE HEAD FASTENER
(2 PER CLIP)
MIRAGE II
PANEL
ROOF STRUCTURAL
MEMBER
MIRAGE II
CLIP
FACTORY APPLIED
SEAM SEALANT
#10-16 X 1" TEK2 PANCAKE
HEAD FASTENER (2 PER CLIP)
MIRAGE II
PANEL
BARGE TRIM LAPS
C-19
BARGE CLIP OR
BARGE CLEAT UNDER
STOP END GUTTER
BARGE TRIM
ATTACH TRIM W/
1/4-14 X 7/8" LAP TEK ZAC
FASTENER (@ EACH RIB)
FIELD NOTCH TRIM
AS NEEDED FOR RIBS
STOP END SHEETS
UNDER TRIM
POP RIVET TOPS
TOGETHER AFTER
ASSEMBLY
BARGE TRIM
BARGE CLIP OR
BARGE CLEAT UNDER
| _MM159 Mir II Inst Man NwCv 7-14 |
| A1 |
| A2 |
| B1 |
| B2 |
| C1 |
| C2 |
| C3 |
| C4 |
| C5 |
| C6 |
| C7 |
| C8 |
| C9 |
| C10 |
| C11 |
| C12 |
| C13 |
| C14 |
| C15 |
| C16 |
| C17 |
| C18 |
| C19 |
| MM159 Mirage II BkCv 01-23-18 |
File details come from the government source that posted it. Updated .