This is a Specifications document for lumber materials required to repair and maintain the Pu'uloa Petroglyph Boardwalk at Hawaii Volcanoes National Park (HAVO). The Government intends to procure commercially available boardwalk materials including decking lumber, structural lumber, fasteners, and hardware to protect significant cultural and archaeological resources while ensuring visitor safety in an environment exposed to high ultraviolet radiation, volcanic gases, wind, heavy rainfall, and corrosive coastal air. All products must comply with the Buy American Act and meet minimum salient characteristics including durability in volcanic and marine environments, resistance to corrosion and UV degradation, non-toxic and environmentally compatible composition, 316 stainless steel fasteners and hardware, dimensional stability, and Chemical Adjuvant Coating (CAC) .15 treated Douglas Fir lumber for rot, fungal decay, and termite protection.
The acquisition includes specific quantities of decking lumber in various dimensions (2"X6" and 2"X4" in lengths from 8' to 16'), framing lumber (4"X6" in 12' and 16' lengths), joist lumber (2"X8" in 8' and 10' lengths), blocking/bracing lumber, and platform lumber, totaling approximately 1,516 pieces. Hardware requirements total 316 stainless steel flat-head deck screws (25,750 screws), Simpson Strong Timber screws (1,300 screws), 264 double-shear face-mount joist hangers, and 72 gang plates. Delivery must occur Monday through Thursday between 6:00 AM and 4:00 PM HDT to the HAVO rain shed at 1 Crater Rim Drive, Hawaii Volcanoes National Park. The Contractor must provide all unloading equipment and personnel, coordinate with the Contracting Officer's Representative ten days prior to delivery, and submit to invasive species inspection per HAVO procedures. The Government reserves the right to reject non-conforming items, and the Contractor shall replace defective materials at no cost. All invoices require approval by the Contracting Officer's Representative before submission to the Invoice Processing Platform.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P8226Q0025_Amd_0004.pdf | ||
| Sol_140P8226Q0025_Amd_0003.pdf | ||
| Sol_140P8226Q0025_Amd_0002.pdf | ||
| Q_A___2_-_140P8226Q0025_HAVO_Lumber_Materials_0002.pdf | ||
| Q_A_-_140P8226Q0025_HAVO_Lumber_Materials_0001.pdf | ||
| Sol_140P8226Q0025_Amd_0001.pdf | ||
| Sol_140P8226Q0025.pdf | ||
| HAVO_Invasive_Pest_SOPs_20241220.pdf | ||
| Specifications_-_Lumber_Materials.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 – Specifications (Revised 6/13/2023)
Specifications - Page 1 of 8
Specifications for:
Lumber Materials for Pu’uloa Petroglyph Boardwalk
For Delivery to Hawaii Volcanoes National Park
1 Crater Rim Drive, HNP HI 96718 Revision 1 – 9.10.26
OVERVIEW
Hawaii Volcanoes National Park (HAVO) intends to purchase commercially available boardwalk materials including decking lumber, structural lumber, fasteners, and hardware. HAVO requires the boardwalk materials to support the repair, rehabilitation, and long-term maintenance of the elevated pedestrian boardwalk system at the Puʻuloa Petroglyph site. The boardwalk protects significant cultural and archaeological resources by directing visitor traffic over fragile lava fields and petroglyph features while providing safe and public access.
The materials must therefore ensure structural integrity, durability, and minimal environmental impact within a federally protected cultural landscape exposed to high ultraviolet radiation, volcanic gases, wind, heavy rainfall, and corrosive coastal air.
The required items must meet the following salient characteristics, which represent the Government’s minimum needs:
• Materials shall be durable in volcanic and marine environments and resistant to corrosion, UV degradation, moisture intrusion, fungal decay, and volcanic ash or gas exposure.
• Products shall be non-toxic and environmentally compatible; treatments and coatings must not leach harmful chemicals and must comply with National Park Service environmental standards.
• Fasteners and hardware shall be 316 stainless steel or equivalent corrosion-resistant material suitable for high-humidity and salt-air conditions.
• Materials must maintain dimensional stability and resist warping, splitting, shrinkage, or deformation under prolonged sun and moisture exposure.
• CAC is a wood preservative used in pressure-treated lumber to protect against rot, fungal decay, and termite damage. It is intended for outdoor structural applications, including above-ground and ground-contact use, where protection against moisture, decay, and insects is required.
These characteristics are essential to protecting significant cultural resources while ensuring visitor safety and long-term performance.
A. MINIMUM SALIENT CHARACTERISTICS or GENERALLY ACCEPTABLE SPECIFICATIONS Note: All products must meet the requirements set forth by the BUY AMERICAN ACT.
Overview of Required Items
Item Item Quantity Item Description
Decking Lumber:
2”X6”X8’
100 2”X6”X8’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Decking Lumber:
2”X6”X10’
216 2”X6”X10’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Decking Lumber:
2”X6”X12’
144 2”X6”X12’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Specifications - Page 2 of 8
Decking Lumber:
2”X6”X16’
2”X6”X16’ Douglas Fir, Chemical Adjuvant Coating
Decking Lumber:
2”X4”X16’
2”X4”X16’ Douglas Fir, Chemical Adjuvant Coating
Framing Lumber:
4”X6”X16’
4”X6”X16’ Douglas Fir Dressed Rough (DR) Chemical Adjuvant Coating (CAC) .15 Treated
Framing Lumber:
4”X6”X12’
75 4”X6”X12’ Douglas Fir Dressed Rough (DR) Chemical Adjuvant Coating (CAC) .15 Treated
Joist Lumber:
2”X8”X8’
2”X8”X8’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Joist Lumber:
2”X8”X10’
72 2”X8”X10’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Blocking/Bracing Lumber: 2”X8”X4’
200 2”X8”X4’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Blocking/Bracing Lumber: 2”X6”X4’
96 2”X6”X4’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Platform Lumber:
2”X8”X10’
200 2”X8”X10’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Platform Lumber:
4”X8”X12’
4”X8”X12’ Douglas Fir, Chemical Adjuvant Coating
Platform Lumber:
2”X6”X12’
36 2”X6”X12’ Douglas Fir, Chemical Adjuvant Coating (CAC) .15 Treated
Hardware: 10X3 316 Stainless Steel Flat head Deck Screws 1750 ct
#10gaugeX3” 316 Stainless Steel Flat head Deck Screws (1750 ct per pack, total of 22,750 screws needed)
Hardware: 10X4 316 Stainless Steel Flat head Wood Screws 1000ct
3 #10 gaugeX4” 316 Stainless Steel Flat head Deck Screws (1000ct per pack, total of 3,000 screws needed)
Hardware: 2”X8” DBL Shear Face Mount Hangers Stainless Steel
2”X8” Double (DBL) Shear Face Mount Hangers Stainless Steel
Hardware: 6" Simpson Strong Timber Stainless Steel Screws
9 6" Simpson Strong Timber Stainless Steel Screws (50ct per pack, total of 450 screws needed)
Hardware: 8" Simpson Strong
10 8" Simpson Strong Timber Stainless Steel Screws (50ct per pack, total of 500 screws needed)
Specifications - Page 3 of 8
Timber Stainless Steel Screws Hardware: 10" Simpson Strong Timber Stainless Steel Screws
7 10" Simpson Strong Timber Stainless Steel Screws (50ct per pack, total of 350 screws needed)
Hardware: 5 ¼” x 8 5/8” Gang plate Stainless Steel Wall Plate
72 5 ¼” x 8 5/8” Gang Blank Plate (Wall Plate), Stainless Steel
Decking Lumber: 2”X6”X8’ Quantity: 100
Summary Description: Douglas Fir decking lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 2”X6”X8’
• Douglas Fir
• Chemical Adjuvant Coating (CAC) .15 Treated
Decking Lumber: 2”X6”X10’ Quantity: 216
Summary Description: Douglas Fir decking lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 2”X6”X10’
Decking Lumber: 2”X6”X12’
Quantity: 144 Summary Description: Douglas Fir decking lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 2”X6”X12’
Decking Lumber: 2”X6”X16’
Quantity: 72 Summary Description: Douglas Fir decking lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 2”X6”X16’
Specifications - Page 4 of 8
Decking Lumber: 2”X4”X16’
Quantity: 85 Summary Description: Douglas Fir decking lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 2”X4”X16’
Framing Lumber: 4”X6”X16’
Quantity: 300 Summary Description: Douglas Fir framing lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 4”X6”X16’
• Douglas Fir
• Dressed Rough
Framing Lumber: 4”X6”X12’
Quantity: 75 Summary Description: Douglas Fir framing lumber with termite and fungal resistance and enhanced with a .15 retention Chemical Adjuvant Coating (CAC) for improved preservative performance and durability in exterior applications.
• 4”X6”X12’
• Douglas Fir
• Dressed Rough
Joist Lumber: 2”X8”X8’
Quantity: 60 Summary Description: Douglas Fir joist lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X8”X8’
Joist Lumber: 2”X8”X10’
Summary Description: Douglas Fir joist lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X8”X10’
Specifications - Page 5 of 8
Blocking/Bracing Lumber: 2”X8”X4’
Quantity: 200 Summary Description: Douglas Fir blocking/bracing lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X8”X4’
Blocking/Bracing Lumber: 2”X6”X4’
Quantity: 96 Summary Description: Douglas Fir blocking/bracing lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X6”X4’
Platform Lumber: 2”X8”X10’
Quantity: 200 Summary Description: Douglas Fir platform lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X6”X4’
Platform Lumber: 4”X8”X12’
Quantity: 96 Summary Description: Douglas Fir platform lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 4”X6”X4’
Platform Lumber: 2”X6”X12’
Quantity: 36 Summary Description: Douglas Fir platform lumber to protection against termites and fungal decay and treated to a .15 retention level with a Chemical Adjuvant Coating (CAC) to enhance preservative effectiveness and durability for exterior structural use.
• 2”X6”X12’
Specifications - Page 6 of 8
Hardware: #10x3”Stainless Steel Flat head Deck Screws
Quantity: 13 packs (1,750ct per pack, total of 22,750 screws) Summary Description: Stainless steel flat head deck screws, corrosion-resistant for exterior and marine use
• #10 gauge X 3”
• 316 Stainless Steel
• Flat head
Hardware: #10x4”Stainless Steel Flat head Deck Screws
Quantity: 3 packs (1,000ct per pack, total of 3,000 screws) Summary Description: Stainless steel flat head deck screws, corrosion-resistant for exterior and marine use
• #10 gauge X 4”
• 316 Stainless Steel
• Flat head
Hardware: 2”X8” Double (DBL) Shear Face Mount Hangers
Quantity: 264 Summary Description: Double-shear face-mount hangers made of corrosion-resistant stainless steel for securely supporting joists in exterior or marine applications
• 2”X8”
• Stainless Steel
Hardware: 6” Timber Screws
Quantity: 9 packs (50ct per pack, total of 450 screws) Summary Description: Corrosion-resistant timber screws designed for heavy-duty fastening of structural lumber in exterior or high-moisture environments.
• 6”
Hardware: 8” Timber Screws
Quantity: 10 packs (50ct per pack, total of 500 screws) Summary Description: Corrosion-resistant timber screws designed for heavy-duty fastening of structural lumber in exterior or high-moisture environments.
• 8”
Hardware: 10” Timber Screws
Quantity: 7 packs (50ct per pack, total of 350 screws) Summary Description: Corrosion-resistant timber screws designed for heavy-duty fastening of structural lumber in exterior or high-moisture environments.
• 10”
Hardware: 5 ¼” X 8 5/8” Gang Plate (Wall Plate)
Specifications - Page 7 of 8
Summary Description: Stainless steel gang plates designed to securely join and reinforce structural lumber connections in exterior or corrosion-prone environments.
• 5 ¼” X 8 5/8”
Safety Features
• Corrosion Resistance: Fasteners, connectors, and hardware shall be 316 stainless steel or equivalent corrosion-resistant material to prevent structural failure in high-moisture, salt-air, and volcanic environments.
• Dimensional Stability and Structural Integrity: Materials must resist splitting, excessive warping, and fastener withdrawal that could create trip hazards or structural instability.
• Code Compliance: All materials shall comply with applicable provisions of the International Building Code (IBC), OSHA safety requirements, and relevant ASTM standards for exterior structural applications.
• Load Capacity: Structural lumber, connectors, and hardware must support required pedestrian live loads as specified by current building codes.
Warranty
• The Contractor shall provide the Government with the standard commercial manufacturer’s warranty normally provided to commercial customers for the same or similar items. The warranty shall be in effect for a period consistent with customary commercial practice, commencing upon delivery and acceptance by the Government.
• The warranty shall include protection against, at a minimum:
o Excessive warping, twisting, cupping, or splitting beyond industry tolerances o Premature fungal decay or termite damage due to treatment failure o Failure of Chemical Adjuvant Coating (CAC) performance o Structural degradation resulting from manufacturing defects
B. OTHER REQUIREMENTS
Incidental Installation
• This acquisition is for materials only. Installation services are not required.
Documentation, Manuals, and Technical Literature The below documentation shall be furnished:
• Bill of lading.
C. GOVERNMENT FURNISHED PROPERTY OR SERVICES
D. DELIVERY INFORMATION
Delivery Location
• 1 Crater Rim Drive HNP, HI 96718
• Items to be delivered to the HAVO rain shed.
• Contact the designated Contracting Officer’s Representative 10 days prior to delivery to coordinate delivery logistics.
Specifications - Page 8 of 8
Delivery Logistics
• A park-operated forklift will NOT be available for unloading. The Contractor is responsible for providing all necessary equipment to offload delivered items. The Contractor must ensure that all personnel operating equipment for delivery are appropriately licensed and qualified, as applicable.
Delivery Term
• The Contractor shall contact the COR within 7 calendar days after contract award to coordinate delivery logistics, including exact delivery dates, locations, and any special site access requirements.
• Delivery shall be made Monday through Thursday between the hours of 6:00 AM HDT to 4:00 PM HDT.
Special Inspections / Invasive Species Inspection
• See the accompanying HAVO Invasive Species SOPs. All Contractor vehicles, to include subcontractor vehicles, shall be inspected for invasive species prior to entering the park. Inspections shall be coordinated with the NPS representative(s) identified by the HAVO Invasive Species SOPs no later than 7 days prior to the intended delivery date. Invasive species inspections may take approximately 1 hour to perform. If the delivery shipment is found to be contaminated with pests, to include little fire ants (LFAs), the shipment will be rejected. If rejected, the shipment must then be treated at the vendor’s expense prior to the rescheduling of a reinspection. If no pests are found, then the material will be accepted.
E. INSPECTION AND ACCEPTANCE
Inspection
• The Contracting Officer’s Representative will inspect the delivered items at the time of delivery.
Acceptance
• The Government reserves the right to reject all items that do not adhere to these specifications. Any item identified through timely inspection that does not conform to these specifications may be rejected by the Government. The Contractor shall replace all non-conforming items at no cost to the Government. The Government reserves the right to seek consideration from the Contractor for failures to satisfy the requirements established by these specifications.
• The Government reserves the right to reject defective items identified through timely inspection. Defects in materials and workmanship include, but are not limited to weld cracks, paint flaking, bubbling, fading, corrosion, and other deficiencies that may require rework or redress.
F. PAYMENT
Payment Made through the Invoice Processing Platform (IPP)
• See the IPP clause within the solicitation or contact award for payment guidance.
• Prior to submitting an invoice to IPP, all invoices shall be submitted to the Contracting Officer’s
Representative or Park Point of Contact for review and, if acceptable, approval.
File details come from the government source that posted it. Updated .