The file's text, extracted by GovTribe without its formatting.
VOYAGEURS NATIONAL PARK
INTERNATIONAL FALLS, MN
Specifications:
Dock Lumber, Floats and Fastening Materials
FY 2026
NATIONAL PARK SERVICE
MIDWEST REGION
OHIO MAJOR ACQUISITION BUYING OFFICE
Brand name or “or equal” requirement, must meet or exceed, based on the following specifications:
Specifications:
· All lumber must be treated Southern Yellow Pine according to below specifications.
· All lumber must be Micronized Copper Azole (MCA) treated to minimum preservation retention of 0.15 PCF.
· All lumber must be certified as Environmentally Preferable Product (EPP).
· All lumber must be Grade #2 or better.
· All materials must be S4S (Surfaced) lumber.
· No installation required – this procurement is for the items listed below and delivery.
· All items shall be provided as one lot and quoted the same; with a breakout of each line item on the Price Schedule in order to compare unit pricing.
· Specifications must be provided for all materials in Unison with the Solicitation quote.
| Description of material or hardware |
| Mfg |
| Part Number |
| Quantity |
| Unit of measure |
| 8”x8”x20’ -MCA Treated * |
| N/A |
| N/A |
| 30 |
| EA |
| 4”x4”x10’ - MCA Treated * |
| N/A |
| N/A |
| 200 |
| EA |
| 6”x6”x16’ - MCA Treated * |
| N/A |
| N/A |
| 80 |
| EA |
| 6”x6”x8’ - MCA Treated * |
| N/A |
| N/A |
| 400 |
| EA |
| 3”x12”x8’ MCA Treated* (Rough cut) |
| N/A |
| N/A |
| 100 |
| EA |
| 2”x8”x8’- MCA Treated * |
| N/A |
| N/A |
| 2000 |
| EA |
| 2”x4”x8’ MCA Treated* |
| N/A |
| N/A |
| 80 |
| EA |
| 2”x8”x10’ - MCA Treated * |
| N/A |
| N/A |
| 50 |
| EA |
| 24”W x 24” L x 48”L Dock Float |
| N/A |
| N/A |
| 64 |
| EA |
| 5/16”x4” Star Washer Head Structure Screw |
| N/A |
| N/A |
| 11,200 |
| EA |
| 5/16”x8” T-40 Washer Head Lag Screw |
| N/A |
| N/A |
| 1,500 |
| EA |
| 1/2” x 5” Galvanized Hex Lag Screw |
| N/A |
| N/A |
| 600 |
| EA |
*All lumber is to be treated with Micronized Copper Azole (MCA) that has a preservation retention of 0.15 PCF. This type of treatment is for wood that is immersed in water or near water and is a more environmentally friendly product.
Delivery of above items required 30 days after contract Award effective date or sooner. Award will be made as ONE LOT.
Additional Requirements:
· Quote shall include delivery and all materials.
· Delivery will be FOB Destination
· Award to be made as ONE LOT.
Delivery Locations:
· Lumber delivery is required at Voyageurs National Park in the below specified quantities:
Voyageurs National Park – Headquarters 380 Highway 11 East International Falls, MN 56649
| 8”x8”x20’ - MCA Treated |
| 30 |
| EA |
| 4”x4”x10’ - MCA Treated |
| 200 |
| EA |
| 2”x4”x8 ‘- MCA Treated |
| 80 |
| EA |
| 6”x6”x8’ - MCA Treated |
| 400 |
| EA |
| 2”x8”x8’ - MCA Treated |
| 2,000 |
| EA |
| 3”x12”x8’ -MCA Treated(rough cut) |
| 100 |
| EA |
| 2”x8”x10’ - MCA Treated |
| 50 |
| EA |
| 6”x6”x16’ -MCA Treated |
| 80 |
| EA |
| 2”x8”x20’ – MCA Treated |
| 30 |
| EA |
| 24”W x 24” L x 48”L Dock Float |
| 64 |
| EA |
| 5/16”x4” Washer Head Structure Screw |
| 11,200 |
| EA |
| 5/16’x8” Washer Head Lag Screw |
| 1,500 |
| EA |
| 1/2" x 5” Galvanized Hex Lag Screw |
| 600 |
| EA |
Dock Float Specifications:
5/16”x4” Star Drive Washer Head Structure Screw Specifications:
· W-Cut thread design reduces installation torque
· Rugged enough for use in LVL, LSL, and other dense wood
· ESR-2442 approved for structural applications
· AC257 code approved for use in treated lumber
| Product type |
| Structural Screws |
5/16” x 8” Lag Fastener Specifications:
· True to size thread diameters, grade 5 heat treat, washer head style
· T-Star 6 lobe design
· Engineered and Manufactured in the USA
· The HCR (High Corrosion Resistant) double barrier coating for use in ground contact and pressure treated lumber
| Finish |
| HCR (High Corrosion Resistant) |
| Product type |
| Structural Screws |
1/2” x 5” Galvanized Hex Lag Screw Specifications:
· Hot galvanized hex lag screw
· Gimlet point
· Suitable for use in treated lumber.
| Finish |
| Hot Dipped Galvanized |
Delivery:
· Delivery required on or before July 10th, 2026, or sooner.
· Vendor must contact park with delivery schedule 1 (one) week prior to delivery.
NPS COR: Steve Schultz Contact info:
· Phone/Mobile COR: 218-240-4472 Email: steve_schultz@nps.gov
· NOTE: We do have the ability to offload the equipment upon delivery.
Site is accessible by full size semi-truck
Voyageurs National Park- Headquarters Maintenance Building Attn: Steve Schultz 380 Hwy 11 East International Falls, MN 56669
** building next to Voyageurs National Park Headquarters Building image1.wmf image2.png image3.png image4.png