Attachment_0002,_40381100_Drawings.pdf
PDF 31 MB Posted
- Attached to
- RENOVATE UPPER FLOOR OF HULLS COVE VC
- Solicitation number
- 140P4318B0008
About this file
Attachment 0002, 40381100_Drawings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P4318B0008.pdf | ||
| B08_Attachment_0004,_General_Decision_Number_-_ME180084.pdf | ||
| Attachment_0001,_40381100_Project_Specifications.pdf | ||
| Attachment_0003,_Bid_Price_Schedule.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
60489
ACAD
ACADIA NATIONAL PARK
HULLS COVE
VISITOR CENTER REHABILITATION
CARPENTER
ASSOCIATES
OLD TOWN, MAINE
MEP & SYSTEMS:
LOWELL
ASSOCIATES
LIBERTY, MAINE
SPECIFICATION:
COPLON ASSOCIATES
LANDSCAPE
ARCHITECTS
BAR HARBOR, MAINE
PRIME:
REGION
NORTHEAST
COUNTY
HANCOCK
STATE
MAINE
TITLE OF DRAWING DRAWING NO.
PKG.
NO.
SHEET
OF
NATIONAL
PARK
SERVICE
Department of the Interior
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
UNITED STATES
A/E FIRM
DEPARTMENT OF THE INTERIOR
Mark Sheet REVISION InitialDate CONSTRUCTION DRAWINGS
LOCATION WITHIN PARK
NAME OF PARK
FRASER ASSOCIATES
ARCHITECTS
BAR HARBOR, MAINE
ARCHITECT:
DRAWING INDEX
SUB-SHEET SHEET SHEET TITLE
C1 1 COVER
G2 2 GENERAL NOTES SCALES, SYMBOLS & ABBREVIATIONS
A1 3 DEMOLITION PLAN & NOTES
A2 4 UPPER LEVEL FLOOR PLAN
A3 5 LOWER LEVEL PARTIAL FLOOR PLAN, ENLARGED TOILETS PLAN
A4 6 UPPER LEVEL REFLECTED CEILING PLAN
A5 7 ROOF PLAN
A6 8 BUILDING SECTIONS 1 & 2
A7 9 BUILDING SECTIONS 3, 4, 5 & 6
A8 10 INTERIOR ELEVATIONS
A9 11 INTERIOR ELEVATIONS 2
A10 12 FEE STATION CASEWORK PLAN, ELEVATIONS AND DETAILS
A11 13 INFORMATION AND MISCELLANEOUS CASEWORK ELEVATIONS & DETAILS
A12 14 DOOR SCHEDULE, DOOR & FRAME TYPES & DETAILS
A13 15 UPPER LEVEL FINISH PLAN, ROOM FINISH SCHEDULE & FINISH KEY
A14 16 INTERIOR DETAILS
A15 17 EXTERIOR DETAILS
S1 18 FRAMING PLANS & DETAILS
D1 19 PLUMBING DEMOLITION
D2 20 MECHANICAL DEMOLITION UPPER LEVEL FLOOR PLAN
D3 21 MECHANICAL DEMOLITION ROOF PLAN
D4 22 ELECTRICAL DEMOLITION UPPER LEVEL FLOOR PLAN
D5 23 ELECTRICAL DEMOLITION ROOF PLAN
P1 24 UPPER LEVEL PLUMBING PLAN
M1 25 UPPER LEVEL MECHANICAL DUCTWORK PLAN
M2 26 UPPER LEVEL MECHANICAL PIPING PLAN
M3 27 MECHANICAL DETAILS
M4 28 MECHANICAL DETAILS
M5 29 MECHANICAL SCHEDULES
E1 30 UPPER LEVEL ELECTRICAL POWER PLAN
E2 31 MEZZANINE ELECTRICAL POWER PLAN
E3 32 UPPER LEVEL ELECTRICAL LIGHTING PLAN
E4 33 ELECTRICAL DIAGRAMS AND SCHEDULES
MUSEUM
MUSEUM
FRENCHMAN
ISLE AU HAUT
16 MILES TO
ISLE AU HAUT
BERNARD
OCEAN
SWAN ISLAND
FERRY TO
ATLANTIC
COVE
SEAL
BEACH
SWIM
SEAWALL
HARBOR
BASS
GREAT
ISLAND
CRANBERRY
HARBOR
NORTHEAST
HARBOR
SOUTHWEST
ATLANTIC
OCEAN
MARSH
PRETTY
AIRPORT
ISLAND
THOMPSON
MT. DESERT102
ISLAND
HQ.
V.C.
HARBOR
BAR
& ELLSWORTH
TO 1
LITTLE
CRANBERRY
ISLAND
BAKER
ISLAND
SWIM BEACH
BLACKWOODS
FABBRI
ATLANTIC
OCEAN
YARMOUTH
NOVA SCOTIA
FERRY TO
O N
E W
AY
STATION
ENTRANCE
O N
E W
AY
BROOK
BEAR
HARBOR
BAR
BAY
PENINSULA
SCHOODIC
& GOULDSBORO
HARBOR
BIRCH
TO 1
& WEST GOULDSBORO
TO 1
ISLE AU
ATLANTIC
HAUT
OCEAN
PARK
NATIONAL
ACADIA
BUCKSPORT
BANGOR
ELLSWORTH
GRAHAM
LAKE 1
LAKE
GRAND
BASIC DATA:
BOUNDARY MAP 123/80,011 5/86; USGS TOPO MAP 1971; PARK MINI FOLDER; COVER SHEET REVISED & REDRAWN 1/94. UPDATED 10/98. SGS.
ACADIA NATIONAL PARK
PICNIC AREA
AIRPORT
LIGHTHOUSE
CAMPGROUND
PARKING
INFORMATION CENTER
RANGER STATION
PARK HEADQUARTERS
VISITOR CENTERV.C.
HQ.
RIVER
FERRY ROUTE
UNPAVED ROAD
COUNTY LINE
PAVED ROAD
PARK BOUNDARY
LEGEND
SCALE OF MILES
20 0 20
MAINE
SCALE OF MILES
SCALE OF KILOMETERS
1 0 1
32 4
2 3
PROJECT LOCATION
G2
123GS FRASER
C. TOWLE
GS FRASER
1/15/2018
GENERAL NOTES
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
172 33
TITLE OF SHEET
SCALES, SYMBOLS
& ABBREVIATIONS
60489
BEARING
BOTH SIDES
BRICK SHELF ELEVATION
CONCRETE MASONRY UNIT
JOINT
CHANNEL
CUBIC FEET PER MINUTE
CONTROL JOINT; CONSTRUCTION
CATCH BASIN; CHALKBOARD
CEMENTITIOUS BACKER BOARD
CONCRETE
COLUMN
CABINET UNIT HEATER
CERAMIC TILE
CONTINUOUS
EXPANSION
EQUAL
EACH WAY
ELECTRIC WATER COOLER
EXISTING
ETHYLENE PROPYLENE DIENE
MONOMER
INSULATED
INVERT
FOOTING
HORIZONTAL
HOLLOW METAL
AIR CONDITIONING
HEATING, VENTILATING AND
HEATING AND VENTILATING
HEAT RECOVERY UNIT
ISOLATION JOINT
IMPACT RESISTANT
INSIDE FACE
HORIZONTAL
HANDICAPPED; HOLLOW CORE
GALVANIZED
GRAB BAR
GRAVITY VENT
GENERAL CONTRACTOR
GYPSUM DROP-IN TILE
GYPSUM WALL BOARD
GAUGE
FIBERGLASS REINFORCED PLASTIC
FRAMED OPENING
FINISHED FLOOR; FAR FACE
FIRE EXTINGUISHER AND CABINET
FAR SIDE
FLOOR CLEAN-OUT
FURNISHED BY OTHERS
FLAT BAR
FLOOR DRAIN
ELEVATION
EXPANSION JOINT
EXHAUST FAN; EACH FACE
EACH
DRAWING
DETAIL
DISHWASHER
DRINKING FOUNTAIN
DISPLAY RAIL
DOUBLE
BUILDING
BOTTOM OF STEEL
BOTTOM OF FOOTING
BORROWED LIGHT PANEL
BOTTOM OF
BRIDGING
BOTTOM
ANCHOR BOLT
AIR CONDITIONING
ACOUSTICAL PLASTER
AIR CONDITIONING CONDENSER UNIT
BOARD
ACCESS PANEL
ACOUSTIC CEILING TILE
ABOVE FINISHED FLOOR
BOTTOM CHORD EXTENSION
FS
IMP
INV
INS
HVAC
H&V
IF
IJ
HRU
GDT
HORIZ
H
HM
HC
GWB
GV
GALV
GC
GB
GA
FTG
EPDM
FE
FO
FRP
FF
FBO
FD
FCO
EXST'G
EWC
FB
EQ
EW
DWG
EL
EXP
EJ
EA
EF
DF
DTL
DW
DR
CUH
DBL
ACCU
BRG
CFM
CONC
CONT
COL
CT
CMU
CJ
CEM BD
C
CB
BSE
BS
BLDG
BRDG
BOF
BOT
BOS
BO
BLP
ACPLAS
AP
BCX
BD
ACT
AFF
AC, A/C
AB
WELDED WIRE FABRIC
VENT THROUGH THE ROOF
SQUARE FOOT; SUPPLY FAN
SUSPENDED ACOUSTIC
ROOFTOP UNIT (HVAC)
VINYL COMPOSITION TILE
VENT PIPE; VERTICAL
UNLESS NOTED OTHERWISE
TOP OF STEEL; TOP OF SLAB
TOILET PAPER (DISPENSER)
TOP CHORD EXTENSION
TOP OF CONCRETE
TEMPORARY BENCHMARK
TOW TOP OF WALL
WITH
WIDE FLANGE
WITHOUT
WEB STIFFENER
WORKING POINT
WATER HEATER
WATER CLOSET
WWF
W/O
WH
WP
WS
WF
WC
W/
TUBE STEEL
VERTICAL
VISION PANEL
VAPOR BARRIER
UNIT HEATER
TYPICAL
VERT
VTR
VP
VB
VCT
V
UNO
UH
TS
TYP
TP
SS STAINLESS STEEL
TACKBOARD
TOP OF FOOTING
TOP OF MASONRY
TIE JOIST
TOP OF
TOP OF PIER
TOP AND BOTTOM
TREAD
STEEL
TOF
TOP
TOS
TOM
TJ
TOC
TO
T&B
TB
TBM
TCE
T
STL
REINFORCED
ROUGH OPENING
SOLID CORE
TILE CEILING
RUB-RAIL
SHEAR KEY
SPECIAL
SIMILAR
REQUIRED
SK
SP
SF
SIM
SC
REINF
SATC
REQ'D
RR
RTU
RO
MEDIUM DENSITY OVERLAY
MOISTURE-RESISTANT
MASONRY OPENING
POOL DEHUMIDIFICATION UNIT
POUNDS PER SQUARE INCH
PAINTED
POLYVINYL CHLORIDE
POWDER-ACTUATED FASTENER
POUNDS PER LINEAR FOOT
POUNDS PER SQUARE FOOT
PA PUBLIC ADDRESS
PLASTIC LAMINATE
POWER PANEL
PLATE
RISER; RADIUS
RESILIENT BASE
ROOF DRAIN
PSF
RB
RD
R
PTD
PVC
PSI
PDU
PLAM
PP
PLF
PL
PAF
MINIMUM
MAKE-UP AIR
NOT TO SCALE
OUTSIDE FACE
ON CENTER
OVERHEAD
NOT IN CONTRACT
NEAR SIDE
NOSING
OC
OH
OF
NS
NTS
MUA
N
NIC
MIN
MR
MO
MAXIMUM
METAL COVE BASE
MDO
MAX
MCBCWP CLEAN WALL PANEL
ABBREVIATIONS
CONTRACTING OFFICERCO
VERIFY IN FIELDVIF
EXISTING TO REMAINETR
LAMINATED VENEER LUMBERLVL
TOILET EXHAUST FANTEF
PRESSURE-TREATEDPT
RECESSED PAPER TOWEL DISPENSERR.P.T.D.
SOAP DISPENSERS.D.
ABOVE FINISHED CEILING AFC
UNDERSIDEUS, U.S.
MARKER BOARDMB
KITCHEN EXHAUST FANKEF
ELECTRIC HAND DRYEREHD
GOVT FURN., CONTRACTOR INSTALLGFCI
GROUND FAULT INTERUPT CIRC.
SANITARY NAPKIN DISPOSALSND
1. FIELD VERIFY ALL DIMENSIONS AND LAYOUT PRIOR TO PROCEEDING WITH
WORK. NOTIFY CONTRACTING OFFICER OF ANY DISCREPANCIES OR
INCONSISTENCIES. FAILURE TO REPORT ANY DISCREPANCIES WITHIN THESE
CONSTRUCTION DOCUMENTS TO THE CONTRACTING OFFICER WILL
NOT BE GROUNDS FOR ADDITIONAL COST OR CHANGE ORDERS.
2. "PROVIDE" MEANS "FURNISH AND INSTALL".
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
MATERIALS (UNLESS NOTED OTHERWISE), AND WORKMANSHIP IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE, CITY AND
LOCAL BUILDING CODES AND THEIR REQUIREMENTS.
4. THE CONTRACTOR AND ALL TRADES SHALL NOTE REQUIREMENTS OF
"GENERAL NOTES" ON ALL SHEETS.
5. ALL DIMENSIONS ARE TO FACE OF STUD AND CENTER LINE OF OPENINGS
UNLESS OTHERWISE NOTED. DIMENSIONS INDICATED ± ARE TO BE VERIFIED
IN FIELD.
6. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND SCOPE.
IN THE EVENT OF A DISCREPANCY BETWEEN THE DRAWINGS, DETAILS AND/OR
SPECIFICATIONS THE MOST STRINGENT REQUIREMENT SHALL APPLY.
7. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING
THE WORK OF ALL SUB-TRADES AND CONTRACTORS FOR THE WORK SHOWN.
GENERAL NOTES:
SCALES:
B
SCALE OF FEET
1/4" = 1'-0" when printed on ANSI D
C
SCALE OF FEET
1/2" = 1'-0" when printed on ANSI D
D
SCALE OF FEET
1" = 1'-0" when printed on ANSI D
E
SCALE OF INCHES
1 1/2" = 1'-0" when printed on ANSI D
F
SCALE OF INCHES
3" = 1'-0" when printed on ANSI D
A
SCALE OF FEET
1/8" = 1'-0" when printed on ANSI D
0 4 8 12 FT
0 4 8 12 FT
0 2 4 6 FT
0 1 2 3 4 FT
0 1 2 3 FT
0 1 2 FT
SYMBOLS
A A1
FIRST FLOOR
ELEVATION 0.00'
A
DETAIL
WALL SECTION
BUILDING SECTION
LEVEL LINE
ELEVATION
WINDOW TAG
DOOR TAG
ROOM NUMBER
WALL TYPE
A A1
A
A A1
A A1
COLUMN ID
x
2' -1
0"
LAVATORY
FRONT
3' -6
1' -3
MIRROR
3' -4
4' -0
3' -0
"17-19"
REAR GRAB BAR SIDE GRAB BAR
6" 3'-0" 1'-0"
SIDE
FRONT SIDE
F.F.
SINK RIM
4' -0
REFL. SURF.
" M
A X
FIRE
EXTINGUISHER
4' -0
3' -6
PUSH-PLATE WALL PHONE
CONTROLS
TYPICAL ADA MOUNTING HEIGHTS
COAT
HOOK
PAPER TOWEL
DISPENSER
SOAP
DISPENSER
" M
A X
BRAILLEHANDLE
ADA
SIGNAGE
3' -0
" 2' -9
7-9"
TP DISPENSER
MOUNTING RANGE
MINIMUM OR MAXIMUM HEIGHTS SHOWN FOR USE WHERE OTHERWISE NOT SHOWN OR INDICATED ON INTERIOR ELEVATIONS
A
LOWER LEVEL - PARTIAL FLOOR PLAN
SCALE B
A3
NEW PARTITION
EXISTING COLUMN TO
REMAIN - PAINT
NEW FLOORING
E.T.R.
EX. CORRIDOR
EX WOMEN
EX. MEN
EX. CLO.
EX BOILER
NEW STOR.
EX JANITOR
EX. BREAK ROOM
EX. SERVER ROOM
UPPER LE
VEL R
EFERENCE
SEE U
PPER LE
VEL P
LA
N THIS
S
HEET
EXISTING WELL TANKS
EXIST. BOILERS
EXIST. ELEC. PANELS
NEW SPLIT SYSTEM HEAT
PUMP WALL CASSETTE
EXISTING SERVER CABINET
A3
123GS FRASER
C. TOWLE
GS FRASER
1/15/2018
LOWER LEVEL PARTIAL
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
172 33
TITLE OF SHEET
FLOOR PLAN
ENLARGED TOILETS PLAN
60489
117120
F
H F
E
H
D
J
H
G
H
G
F E
D
E X
E X
E X
EX1
F C
E X
ENLARGED TOILET PLANS
SCALE C
A3
1'-0" 3'-6"
6" 3'
-0
1' -6
5' -0
/8
3/
4" 2'
-7
/4
3/ 4"
2' -7
/4
1'
-9
/4
2' -1
0" 3/
4" 2'
-1 0"
3/ 4"
2' -1
0" 3/
4" 2'
-1
1/ 8"
'-6 fa ce o f s tu d
1' -8
/4 fa ce o f s tu d
'-7
/8 fa ce o f s tu d
1/
2" fa ce o f s tu d
7' -1
3/
8" fa ce o f s tu d
5 1/2" face of stud
8'-4" face of stud
5 1/2" face of stud
8'-4 1/8" face of stud
2' -0
/8
2' -9
3/
4" 2'
-9
3/ 4"
2' -6
3/
4" 2'
-6 "3'-7 3/4" 4'-8 1/2"
1' -4
/4
2'
-6
1' -4
/4
1/
2" 6'
-1
1/ 2"
1/
2" 8'
-4
/8
1/
2" 7'
-9
/4
1/
2"
1' -6
/4
2'
-1 1"
1' -9
/4
1'
-6
/4
3 1/2" 2'-0 3/4"
1'-11 1/2" 2'-6" 2'-6" 1'-3"
2' -0
/4
2'-0 1/2"
3' -1
/8
EHD
S.D. (TYP)
MOP RECEPTOR
FIXED SHELF
ADJUSTABLE SHELVES
(5) ON STANDARDS &
BRACKETS
5'-0" 3/4"
2'-6"
SAFE
BELOW:
G.F.C.I.
P. LAM COUNTER
@ 30" A.F.F.
3/4" 5'-0"
NEW DRINKING
FOUNTAIN
FURRED WALL
FOR DF
PLUMBING
1/
2"
2'-0 1/2"
'-8
/2
EHD
S.D. (TYP)
EHD
NOTE: PATCH AND REPAIR EXISTING PLUMBING
PENETRATIONS LOCATED IN EXISTING FLOOR SLAB.
REFER TO PIPE PENETRATION SLAB PATCHING
DETAIL ON SHEET S1
BABY
CHANGING
STATION
FD
FD
FD
FD
6" 3'
-0
3'-6" 1'-0"
3'-10"
WALL CABS
ABOVE
5'-1 1/2" 3'-2 5/8"
LO
W
ER LE
VEL R
EFERENCE
SEE LO
W
ER LE
VEL P
LA
N THIS
S
HEET
1' -1
0"
1'-10"
2' -1
/8
1/ 2"
5' -6
/8
2' -4
10"
SND
SND
SND
SND
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI
TP GFCI SND
B
SCALE OF FEET
1/4" = 1'-0" when printed on ANSI D
0 4 8 12 FT
C
SCALE OF FEET
1/2" = 1'-0" when printed on ANSI D
0 2 4 6 FT
A9
123GS FRASER
C. TOWLE
GS FRASER
1/15/2018
INTERIOR ELEVATIONS 2
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
172 33
TITLE OF SHEET
60489
WOMENS - NORTH
SCALE B
A9
TOILET PARTITION
SYSTEM AS SPECIFIED
SND
P.T.
WOMENS - EAST
SCALE B
A9
V.W.C.
TILE WALL BASE
DIRECT APPLIED WOOD
CEILING - SEE R.C.P., MECH.
AND ELEC.
LAV WITH SINK
FAUCET AND
MIRROR
TOILET PARTITION SYSTEM
AS SPECIFIED
WOMENS - SOUTH
SCALE B
A9
A 11 7
VINYL WALL
COVERING
DIRECT APPLIED WOOD
CEILING
MIRROR
S.D.
FAUCET
H.D.
P.T. WALL BASE ON
P.T. FLOOR ASS'Y.
3' -6
4"
2' -1
0"
WOMENS - WEST
SCALE B
A9SCHEDULED DOOR
VINYL WALL
COVERING
DIRECT APPLIED WOOD
CEILING
PAINTED DOOR
FRAME
LAV.
H.D.
TOILET PARTITION SYSTEM
AS SPECIFIED
3' -0
P.T.
CHASE TO MEZZANINE
ABOVE - SEE PLAN
MENS - NORTH
SCALE B
A9
URINAL
WITH
FLUSH
P.T.
TOILET PARTITION
SYSTEM AS SPECIFIED
MENS - EAST
SCALE B
A9
7 A
URINAL WITH FLUSH
P.T. BASE
TOILET PARTITION
SYSTEM AS SPECIFIED
MIRROR
V.W.C.
H.D.
S.D.
FAUCET
1' -5
2' -0
LIGHT FIXTURE
MENS - SOUTH
SCALE B
A9
SCHEDULED DOOR
V.W.C.
LAVATORY
DIRECT APPLIED WOOD
CEILING
PAINTED DOOR
FRAME
SINK AND
FAUCET
MIRROR
MENS - WEST
SCALE B
A9
8' -0
VINYL WALL
COVERING (V.W.C.)
TILE WALL BASE
DIRECT APPLIED WOOD
CEILING
6"
B
SCALE OF FEET
1/4" = 1'-0" when printed on ANSI D
0 4 8 12 FT
MERCHANDISE - NORTH
SCALE B
A9
PAINTED
GYPSUM
WALL
BOARD
SCHEDULED
WALL BASE
MERCHANDISE COUNTER (BY OTHERS)
PENDANT LAMP - SEE ELECTRICAL
'-0
SCHEDULED DOOR
A.C.T. CEILING SYSTEM
1X8 MAPLE FASCIA
MERCHANDISE - EAST
SCALE B
A9
PAINTED GYPSUM
WALL BOARD
SCHEDULED
WALL BASE
SUSP. TRACK LIGHT
CASEWORK BY OTHERS
OPEN
WD. PANEL
CEILING
A.C.T. CEILING SYSTEM
7' -7
/4
DRYWALL SOFFIT
9' -0
'-0
MERCHANDISE - SOUTH
SCALE B
A9
PAINTED GYPSUM
WALL BOARD
SCHEDULED
WALL BASE
A.C.T. CEILING SYSTEM
F.E.C.
SCHEDULED DOOR
SUSPENDED TRACK LIGHT
8' -3
1' -4
MERCHANDISE - WEST
SCALE B
A9
WD. PANEL CEILING - SEE
R.C.P. AND INTERIOR DETAILS
PAINTED GYPSUM WALL
BOARD
SCHEDULED WALL BASE
SUSP. TRACK LIGHT
FAMILY - NORTH
SCALE B
A9
P.T.
GRAB BAR -
PROVIDE
BLOCKING
9"3' -0
VWC
4' -6
SND
FAMILY - EAST
SCALE B
A9
2' -1
0" 3'
-4
MIRROR
G.B.
ADA PIPE
PROTECTOR
LAV.
P.T.
H.D.
LIGHT FIXTURE
6' -6
VWC
FAMILY - SOUTH
SCALE B
A9
SCHEDULED DOOR - SEAL FRAME
PERIMETER - TYPICAL AT RESTROOMS
AND WHERE NOTED
H.D.
COAT HOOK
LAV.
FAMILY - WEST
SCALE B
A9
BABY
CHANGING
STATION
8' -0
2' -0
/2
D1
123DC
11-20-2017
PLUMBING
DEMOLITION
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
172 33
TITLE OF SHEET
60489
JE
RB
D2
123DC
MECHANICAL
DEMOLITION
UPPER LEVEL PLAN
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
172 33
TITLE OF SHEET
60489
JE
RB
11-20-2017 geoff GSF Arch Stamp
D3
DC
MECHANICAL
DEMOLITION
ROOF PLAN
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
11-20-2017
60489
D4
ELECTRICAL
DEMOLITION
UPPER LEVEL PLAN
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
11-20-2017
60489
D5
ELECTRICAL
DEMOLITION
ROOF PLAN
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
11-20-2017
60489
P1
UPPER LEVEL
PLUMBING PLAN
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
GAS
11-20-2017
60489 x1
FABRIC DUCT (FDD-1)
U .C
12x12
30x16
16Ø
10x14
EG-1
42011Ø
9Ø
34x16
EG-3
EG-3
Ø
EG-2
SG-1
FABRIC DUCT (FDD-2)
FABRIC DUCT (FDD-3)
Ø
18Ø
8Ø
U.C.
10Ø
8Ø
SD-2
RG-2
Ø
SD-4
10Ø 8Ø
8Ø
20x12
RG-1
8Ø
5Ø5Ø5Ø
5Ø
4Ø
EG-1
EG-3
x1
7Ø
EG-2
5Ø
5Ø
5Ø 7Ø
EG-2
M1
DC
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
UPPER LEVEL
MECHANICAL
DUCTWORK PLAN
11-20-2017
60489
M2
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
UPPER LEVEL
MECHANICAL
PIPING PLAN
11-20-2017
60489
M3
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
MECHANICAL DETAILS
11-20-2017
60489
STOCK
M4
DC
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
MECHANICAL DETAILS
11-20-2017
60489
M5
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
MECHANICAL SCHEDULES
11-20-2017
60489
E1
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
UPPER LEVEL
ELECTRICAL
POWER PLAN
11-20-2017
60489
E2
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
11-20-2017
60489
MEZZANINE
ELECTRICAL
POWER PLAN
E3
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
UPPER LEVEL
ELECTRICAL
LIGHTING PLAN
11-20-2017
60489
E4
ACADIA NATIONAL PARK
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
SHEET
OF
PKG.
NO.
ACAD
TITLE OF SHEET
JE
RB
ELECTRICAL
DIAGRAMS AND
SCHEDULES
11-20-2017
60489
| G2-NOTES & ABBREVIATIONS |
| 1/G2 |
| 1/G3 |
| 1/G4 |
| 1/G5 |
| 1/G6 |
| 1/G7 |
| Viewport-59 |
| A1-DEMOLITION PLAN |
| 1/A1a |
| 1/A1a-2 |
| 3/A1 |
| 1/G8 |
| 1/G9 |
| A2-MAIN LEVEL PLAN |
| MAIN FLOOR PLAN |
| 1/G11 |
| 2/A2 |
| A3-LOWER LEVEL |
| 1/Layout2 |
| 3/A2 |
| 1/G12 |
| 1/G13 |
| A4-MAIN LEVEL REFLECTED CEILING PLAN |
| 1/Option 6 |
| 1/G14 |
| A5-ROOF PLAN |
| 1/G28 |
| ROOF PLAN |
| A6-BUILDING SECTIONS |
| 1/A5 |
| 2/A5 |
| 1/G15 |
| A7-BUILDING SECTIONS |
| 4/A5 |
| 3/A5 |
| 5/A6 |
| 6/A6 |
| 1/G16 |
| A8-INTERIOR ELEVATIONS |
| 1/G17 |
| Viewport-1 |
| Viewport-2 |
| Viewport-3 |
| Viewport-4 |
| Viewport-5 |
| Viewport-6 |
| Viewport-7 |
| Viewport-8 |
| Viewport-9 |
| Viewport-10 |
| Viewport-11 |
| Viewport-21 |
| A9-INTERIOR ELEVATIONS |
| Viewport-12 |
| Viewport-13 |
| Viewport-14 |
| Viewport-15 |
| Viewport-16 |
| Viewport-17 |
| Viewport-18 |
| Viewport-19 |
| 1/G18 |
| Viewport-20 |
| Viewport-22 |
| Viewport-23 |
| Viewport-24 |
| Viewport-25 |
| Viewport-26 |
| Viewport-27 |
| Viewport-28 |
| A10-CASEWORK ELEVATIONS |
| Viewport-30 |
| 1/G22 |
| 8/A9 |
| 6/A9 |
| FEE DESK SECTION 2 |
| Section-1 |
| 1/G21 |
| Section-2 |
| A11-CASEWORK ELEVATIONS |
| 1/G23 |
| 1/G24 |
| Viewport-32 |
| Viewport-33 |
| Viewport-34 |
| Viewport-35 |
| 5/A9 |
| Viewport-52 |
| 1/G19 |
| Viewport-56 |
| Viewport-41 |
| A12-DOOR SCHEDULE AND DETAILS |
| 10/A9 |
| Viewport-39 |
| Viewport-40 |
| Viewport-55 |
| Viewport-43 |
| Viewport-46 |
| Viewport-29 |
| Viewport-31 |
| Viewport-36 |
| Viewport-44 |
| 1/G34 |
| 1/G35 |
| 5/A12 |
| 5/A13 |
| Viewport-47 |
| Viewport-53 |
| Viewport-54 |
| Viewport-57 |
| Viewport-48 |
| Viewport-49 |
| Viewport-50 |
| Viewport-45 |
| Viewport-58 |
| Viewport-60 |
| Viewport-61 |
| Viewport-62 |
| A13-EXTERIOR DETAILS |
| Viewport-38 |
| Viewport-42 |
| MAIN FLOOR PLAN-2 |
| 1/G30 |
| A14-ROOM SCHEDULE & INTERIOR DETAILS |
| 1/G27 |
| 3/A15 |
| 1/A14 |
| 1/A15 |
| 5/A15 |
| 6/A15 |
| 1/A18 |
| 1/A19 |
| 1/A20 |
| ATTIC PULL DOWN |
| 1/A22 |
| A15-INTERIOR DETAILS |
| 1/G25 |
| SKYLIGHT |
| ROOF HATCH |
| ERV |
| S1-FRAMING PLANS AND DETAILS |
| 7/S1 |
| 7/S2 |
| 1/S2 |
| 1/S3 |
| 1/S4 |
| 1/S5 |
| 1/S6 |
| 1/G20 |
| 1/G10 |
| Viewport-37 |
File details come from the government source that posted it.