This document appears to be a set of technical drawings for a typical 4-wire barbed wire fence design. The drawings provide specifications for the construction of the fence, including details on the minimum required dimensions for the fence components, the use of wood or steel line posts, the placement of braces and stays, and other key structural elements. While the document does not directly address a federal contract opportunity, it seems to be a technical reference that could be relevant to a contract for the construction or modification of a pronghorn antelope fence, as described in the related federal contract opportunity.

The related federal contract opportunity is for the modification of 2.75 miles of fence to facilitate the migration of pronghorn antelope, as per the attached Statement of Work (SOW). The solicitation number is 140L6224Q0059, and the contracting agency is the Department of the Interior Bureau of Land Management, Wyoming Region. The contract is for fiscal year 2024, but no specific response or award dates are provided.

View the file

Other files

File Type Posted
02824-9_1_.pdf PDF
Pronghorn_Migration_Fence_Mods_-_McCullough_Peaks_SOW.docx DOCX document
02824-11_1_.pdf PDF
02824-6_1_.pdf PDF
Map_-_Pronghorn_Fence_Mods_FY24_Overview.pdf PDF
Sol_140L6224Q0059.pdf PDF
Map_-_Pronghorn_Fence_Mods_FY24_Zoomed.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

h

H

H h

A B

C D E

A B

C D

E

6'-6" MIN.6'-0" MIN. 6'-6" MIN. 6'-6" MIN.

6'-6" MIN.

L

SEE MORTISE DETAIL6'-6"(1981 mm) MIN. BRACE

SPIKE

9-GA. SMOOTH GALV. WIRE

ADD ADDITIONAL WIRE OF THE SAME MATERIAL AS BOTTOM WIRE

OF FENCE & A ROCK DEADMAN (MIN. WEIGHT 50 LBS (22.5 kg)) WHEN SPACE BETWEEN BOTTOM WIRE & GROUND EXCEED 20" (508 mm)

LINE POST

(WOOD OR

STEEL)

END PANEL-TYPE I END PANEL-TYPE II

PANEL AT MINOR DEPRESSIONSTRESS PANEL

h

H

1 2

H h

L L L

2"(51 mm) MIN.

TWISTED WIRE OR WOOD STAY

STEEL LINE POST

1. SEE SPECIFICATIONS FOR THE FOLLOWING:

A. RATIO OF STEEL TO WOOD LINE POSTS.

B. POST SPACING, LENGTH & DEPTH IN GROUND.

C. TYPE OF END PANEL TO BE USED.

D. TYPE OF WIRE TO BE USED.

E. SPACING BETWEEN WIRES.

F. NUMBER OF STAYS PER SPAN (L).

SPIKE (SPIKING

OR TOE NAILING

AS SPECIFIED)

LINE PANELS

MORTISE DETAIL

NOTES:

1"(25 mm)

1"(25 mm)

A B

C D

E

(1829 mm) (1981 mm) (1981 mm) (1981 mm)

(1981 mm)

2. THE METRIC CONVERSIONS ARE PROVIDED IN PARENTHESIS

FOLLOWING THE ENGLISH UNITS.

DRAWING NO. 02824-1

REV. NO.

REVIEWED

DESIGNED

APPROVED

SAFETYALWAYS THINK DATE APRIL 26, 1997

DRAWN

1 LJP

APPROVED

METRIC CONVERSION ADDED

SHEET OF

SCALE NONE

DESCRIPTION DATE

9/30/97

BY OTHERS

TYPICAL

BARBED WIRE FENCE

(4-WIRE)