B09_Amend_2_Attachment_1__22Q0035_2022_RFO_Overflow_Fences_All_Maps_0002.pdf

PDF 10 MB Posted

Attached to
2022 RFO OVERFLOW FENCE CONSTRUCTION
Solicitation number
140L0622Q0035
Issued by

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

Legend

Retention Dam

Storage tank

Trough

Well with Storage

Four strand

D Net wire

Subsurface

NM Allotment Boundary

Bureau of Land Management

Private

State

Use exisitng SP 0+00 104°21'30.725"W 33°16'53.699"N

CP 14+10

104°21'30.678"W 33°16'39.622"N

SP 27+25

EP 41+45

104°22'2.379"W 33°16'39.662"N

T12S R26E

No warranty is made by the Bureau of Land Management as to the accuracy, reliability, or completeness of these data for individual use or aggregate use with other data, or for purposes not intended by BLM. Spatial information may not meet National Map Accuracy Standards. This information may be updated without notification.

LOCATION MAP

0 0.09 0.18 Miles UNITED STATES DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

Pecos District Office New Mexico

PROJECT LOCATION MAP

2022 RFO Overflow Fence 1

Replacement

DESIGNED

REVIEWED

APPROVED

DRAWING NO.

SCALE

SHEET 1 OF 1

Russell Fox K. Davis and D. Bell

Nathan Curnutt 1:8,000DRAWN BY: rfox

DATE: 4/28/2022

Chaves Co. work sites

Estimate measured with String Chain Fence to be removed=4,145' Fence to be built=4,145' Corner Panel=CP=1 3 Brace Corner Panel=3BCP=0 End Panel=EP=1 Stress Panel=SP=1 Wire Gate=WG=0 Single Metal Post=SMP=0 Tie in old fences at braces.

3BCP 0+00

104°21'30.978"W 33°17'3.714"N

EP WG EP 13+80

104°21'47.237"W 33°17'4.905"N

CP 27+40

104°21'47.848"W 33°17'18.525"N

EP 40+00

104°22'2.885"W 33°17'18.241"N

EP 9+10 Spur line 104°21'57.186"W 33°17'10.733"N

Use existing braces for pipeline ROW 31+63 Also this is the SMP WG EP 0+00 for this spur line to the southwest.

104°21'53.232"W 33°17'18.458"N MICHELET

NANCY ANN

0 0.09 0.18

2022 RFO Overflow Fence 2

Replacement 7-7-22

1:7,887DRAWN BY: rfox

DATE: 7/7/2022

Fence to be removed=4,000' Fence to be built=4,910' Corner Panel=CP=1 3 Brace Corner Panel=3BCP=1 End Panel=EP=5 Stress Panel=SP=0 Wire Gate=WG=2 Single Metal Post=SMP=1

CP 4+00

104°21'31.128"W 33°17'5.869"N

SP 0+00

3BCP 0+00

104°21'14.169"W 33°17'5.76"N

SP 11+65

3BCP 10+80

Only build new fence north of this point, there is no removal.

104°21'19.698"W 33°17'18.775"N

EP 1+60

104°21'24.614"W 33°17'18.932"N

CP 3+50 3 BCP 0+00

From 0+00 to 10+80 there is no fence to remove, only new construction.

104°21'15.689"W 33°17'26.445"N

EP WG CP 6+15 for the east west line and31+10 for line from the north.

EP WG CP 14+90 and 0+00 for Spur to the west.

CP 18+50

Lassater

Spring

0 0.045 0.09

2022 RFO Overflow Fence 3

1:4,092DRAWN BY: rfox

Fence to be removed=3,755' Fence to be built=4,835' Corner Panel=CP=5 3 Brace Corner Panel=3BCP=3 End Panel=EP=3 Stress Panel=SP=2 Wire Gate=WG=2

0+00 104°21'21"W, 33°17'58"N

26+60 104°21'25"W, 33°17'41"N

47+70 104°21'23"W, 33°17'19"N

8 9

5 4

0 0.085 0.17

2022 RFO Overflow Fence 4

Removal

1:7,702DRAWN BY: rfox

DATE: 4/30/2022

Fence to be removed=4,770' Fence to be built=0' Corner Panel=CP=0 3 Brace Corner Panel=3BCP=0 End Panel=EP=0 Stress Panel=SP=0 Wire Gate=WG=0

EP WG EP 7+15

Build gate on the east west fence.

104°21'46"W, 33°17'34"N

EP 10+00

104°21'53"W, CP 1+25

104°21'52"W, 33°17'33"N

EP 4+40

104°21'54"W, 33°17'31"N

CP3+25

104°21'53"W, 33°17'31.6"N

3BCP 8+50 and of 0+00 spur line to the southwest.

104°21'52"W, EP 0+00

104°21'46"W, 33°17'36"N

0 0.02 0.04

2022 RFO Overflow Fence 5

1:1,933DRAWN BY: rfox

DATE: 5/2/2022

Fence to be removed=1,440' Fence to be built=1,440' Corner Panel=CP=2 3 Brace Corner Panel=3BCP=1 End Panel=EP=5 Stress Panel=SP=0 Wire Gate=WG=1

EP 0+00

104°21'48"W 33°17'40"N

EP 2+50

104°21'46"W 33°17'38"N

R26E8

0 0.006 0.012

2022 RFO Overflow Fence 6

1:567DRAWN BY: rfox

DATE: 5/3/2022

Fence to be removed=250' Fence to be built=250' Corner Panel=CP=0 3 Brace Corner Panel=3BCP=0 End Panel=EP=2 Stress Panel=SP=0 Wire Gate=WG=0

EP 23+40

104°21'49"W, 33°17'44"N

CP 20+70

104°21'48"W, 33°17'46"N

CP 10+60

104°21'40"W, 33°17'51"N

EP WG EP 9+50

104°21'39"W, 33°17'51"N

3BCP in fence number 8 and 0+00 southwestern spur line.

104°21'35"W, 33°17'58"N

5 Lassater

0 0.045 0.09

2022 RFO Overflow Fence 7

1:4,000DRAWN BY: rfox

Fence to be removed=2,340' Fence to be built=2,340' Corner Panel=CP=2 3 Brace Corner Panel=3BCP=1 End Panel=EP=3 Stress Panel=SP=0 Wire Gate=WG=1

EP WG EP 0+00

One on each side of fence.

104°21'0"W, 33°18'22"N

EP WG EP 22+80

side of road.

104°21'23"W, CP 0+00

104°21'16"W, 33°17'45"N

33°17'32"N

CP 9+20

104°21'38"W, 33°18'13"N

3BCP 3+50 in fence number 8 and 0+00 in fence #7 southwestern spur line.

104°21'35"W, EP @ edge of river 0+00 104°21'41"W, 33°18'20"N

SMP WG EP 18+40

104°21'50"W, SMP 7+75

104°21'39"W, 33°18'14"N

SMP 11+00

104°21'37"W, 33°18'12"N

CP 18+40

104°21'31"W, 33°18'8"N

3BCP 30+20 and EP WG EP

WG EP 0+00

for spur line to the west.

104°21'32"W, EP 42+70

33°17'48"N

EP 45+60

33°18'9"N

3BCP 31+20

33°18'21"N

#6

#7

#5

#9 104°21'21"W, 33°17'58"N

SP 13+20

T11S R25E

0 0.1 0.2

2022 RFO Overflow Fence 8

1:12,500DRAWN BY: rfox

Fence to be removed=10,670' Fence to be built=10,670' Corner Panel=CP=4 3 Brace Corner Panel=3BCP=2 End Panel=EP=11 Stress Panel=SP=1 Wire Gate=WG=5 Single Metal Post=SMP=3

3BCP 30+20 and 0+00 for spur line to the west.

EP WG EP 0+00

side of road.

104°21'21"W, EP 1+15

0 0.0095 0.019

2022 RFO Overflow Fence 9

1:855DRAWN BY: rfox

DATE: 5/2/2022

Fence to be removed=115' Fence to be built=115' Corner Panel=CP=0 3 Brace Corner Panel=3BCP=0 End Panel=EP=3 Stress Panel=SP=0 Wire Gate=WG=1

SP SP 0+00

side of fence.

104°21'0"W, SP SP 220' of new fence.

104°21'13"W, 33°17'45"N

33°17'32"N

#8 104°21'41"W, 33°18'20"N

104°21'50"W, 33°18'21"N

#6 104°21'47"W 33°17'39"N

#7 104°21'48"W 33°17'44"N

#5 104°21'45"W 33°17'33"N

#9

#4

33°17'19"N

#3 104°21'20"W 33°17'18"N

#3 104°21'26"W 33°17'5"N

#1 104°21'30"W 33°16'39"N

#2 104°22'2"W, 33°17'18"N

LIN

CO

LN

DARBY

T11S R25E

17 16

Calumet Ranch

65069

Spring

West #1

0 0.25 0.5

2022 RFO Overflow Fences

Overall Map Replacement 7-7-22

1:24,000DRAWN BY: rfox

Fence to be removed=31,485' Fence to be built=28,705' Corner Panel=CP=15 3 Brace Corner Panel=3BCP=8 End Panel=EP=33 Stress Panel=SP=4 Wire Gate=WG=12 Single Metal Post=SMP=4

File details come from the government source that posted it. Updated .