B09_ATCH_1_Amend_3_SALIENTS_Submersible_Press_Sensors_3-7_0003.pdf
PDF 174 KB Posted
- Solicitation number
- 140G0123Q0085
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
140G0123Q0085 Amendment 0003 ATCH 1 SALIENTS 3‐7‐2023
Salient Characteristics S23045
SUBMERSIBLE PRESSURE SENSORS
14 Ea. Submersible Pressure Sensor
1. Shall consist of a vented-type submersible pressure transducer with a measurement range from 0 to 22 psi.
2. Shall meet, or exceed, USGS requirements for stage accuracy measurements. Accuracy shall have an uncertainty of 0.01 ft or 0.10 percent of indicated reading whichever is larger, over a temperature range of 0 to +50 degrees C.
3. Shall include a ceramic type sensing element.
4. Shall have a stainless-steel housing.
5. Shall include RS 485 with SDI-12 protocol.
6. Shall have an open face nose cap.
7. Shall be compatible with removable cables.
8. Shall not include lightning protection or moisture protection.
9. Shall be capable of operating from an external 12 VDC power source
10. Shall be no larger than 1.0” in diameter by 6” in length.