About this file

This document is a Certificate of Analysis for Standard Reference Material 2711a Montana II Soil. The certificate provides certified, reference, and information values for the concentrations of various elements in the soil material on a dry mass basis. Certified values determined through multiple analytical techniques at NIST are provided for 31 elements along with their associated uncertainties. Reference values from a single NIST method are given for 12 additional elements. Information values from one NIST method are listed for 13 elements. The certificate also specifies instructions for use, sources and preparation of the material, analytical methods used, participating analysts, references, and supplemental information including a particle size distribution. A study by EPA contract laboratories on leachable element concentrations using EPA methods is summarized in an appendix.

View the file

Other files

File Type Posted
Provisions and Clauses.docx DOCX document
Statement of Requirements.docx DOCX document
Solicitation.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SRM 2711a Page 1 of 7

National Institute of Standards & Technology

Certificate of Analysis

Standard Reference Material® 2711a

Montana II Soil

Moderately Elevated Trace Element Concentrations

This Standard Reference Material (SRM) is intended primarily for use in the analysis of soils, sediments, or other materials of a similar matrix. One unit of SRM 2711a consists of 50 g of the dried, powdered soil.

Certified Values: The certified concentrations of elements, expressed as mass fractions [1] on a dry-mass basis, are provided in Table 1. Certified values are based on results obtained from critically evaluated independent analytical techniques. A NIST certified value is a value for which NIST has the highest confidence in its accuracy in that all known or suspected sources of bias have been investigated or taken into account [2]. The measurands are the total concentrations of the elements reported in Table 1. Metrological traceability is to the SI unit of mass expressed as the derived unit of mass fraction.

Reference Values: The reference values for elements, expressed as mass fractions on a dry-mass basis, are provided in Table 2. The reference values are based on results obtained from a single NIST analytical method. Reference values are non-certified values that are the best estimate of the true value; however, the values do not meet NIST criteria for certification and are provided with associated uncertainties that may not include all sources of uncertainty [2]. The measurands are the total concentrations of the elements reported in Table 2. Metrological traceability is to the SI unit of mass, expressed as the derived unit of mass fraction.

Information Values: Information values for elements obtained from one NIST method, are provided in Table 3.

Particle size measurements are provided in Figure 1. An information value is considered to be a value that will be of use to the SRM user, but insufficient information is available to assess the uncertainty associated with the value or only a limited number of analyses were performed [2]. Information values cannot be used to establish metrological traceability.

Expiration of Certification: The certification of SRM 2711a is valid, within the measurement uncertainty specified, until 01 January 2029, provided the SRM is handled in accordance with the instructions given in this certificate (see “Instructions for Use”). This certification is nullified if the SRM is damaged, contaminated, or otherwise modified.

Maintenance of SRM Certification: NIST will monitor this SRM over the period of its certification. If substantive technical changes occur that affect the certification before the expiration of this certificate, NIST will notify the purchaser. Registration (see attached sheet or register online) will facilitate notification.

E.A. Mackey and R.R. Greenberg, formerly of the NIST Analytical Chemistry Division, and S.E. Long of the NIST Chemical Sciences Division, were responsible for coordination of the technical measurements.

Statistical analyses were performed by J.H. Yen of the NIST Statistical Engineering Division.

Support aspects involved in the issuance of this SRM were coordinated through the NIST Office of Reference Materials.

Carlos A. Gonzalez, Chief Chemical Sciences Division

Gaithersburg, MD 20899 Steven J. Choquette, Director Certificate Issue Date: 02 May 2022 Office of Reference Materials Certificate Revision History on Page 6

SRM 2711a Page 2 of 7

INSTRUCTIONS FOR USE

Sampling: The SRM should be thoroughly mixed by repeatedly inverting and rotating the bottle horizontally before removing a test portion for analysis. A minimum mass of 250 mg (dry mass - see Drying) should be used for analytical determinations to be related to the mass fraction values in this Certificate of Analysis.

To obtain the certified values, sample preparation procedures should be designed to effect complete dissolution. If volatile elements (i.e., arsenic, mercury, selenium) will be determined, precautions should be taken in the dissolution of SRM 2711a to avoid volatilization losses.

Drying: To relate measurements to the certified, reference, and information values that are expressed on a dry-mass basis, users should determine a drying correction at the time of each analysis. The recommended drying procedure is oven drying for 2 h at 110 °C. Note that analytical determination of volatile elements (i.e., arsenic, mercury, selenium) should be determined on samples as received; separate samples should be dried as previously described to obtain a correction factor for moisture. Correction for moisture must be made to the data for volatile elements before comparing to the certified values. This procedure ensures that these elements are not lost during drying. The mass loss on drying for this material as bottled was approximately 2 %, but this value may change once the bottle is opened and the soil is exposed to air.

SOURCE, PREPARATION, AND ANALYSIS

Source and Preparation of Material(1): The U.S. Geological Survey (USGS), under contract to NIST, collected and processed the material for SRM 2711a. Soil was collected from the top 10 cm to 12 cm of an agricultural field located near a site formerly used by a smelting plant, in east Helena, Montana. Collection was performed using a common garden spade, and the material was stored in 20 plastic-lined five-gallon buckets with snap-on lids. At the USGS, the SRM 2711a soil was dried at room temperature, disaggregated, and sieved to remove coarse material (≥2 mm). The resulting soil was ball-milled in 50 kg portions. The entire ball-milled batch of soil was transferred to a cross-flow V-blender for mixing. The blended soil was radiation sterilized prior to bottling. In the final preparation step the blended material was split into containers using a custom-designed spinning riffler, which was used to divide the material into smaller batches, and then used to apportion approximately 50 g into each pre-cleaned bottle.

Every 100th bottle was set aside for chemical analyses designed to assess material homogeneity using X-ray fluorescence spectrometry (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and inductively coupled plasma mass spectrometry (ICP-MS) at the USGS. Homogeneity assessment and sieving tests performed at NIST indicated that additional processing was needed to achieve optimum homogeneity. The material from all bottles was combined, and then ground in batches between stainless steel plates for a time sufficient to produce a powder of which ≥95 %, by mass, passed through a 200 mesh (74 µm) sieve. The resulting powder was blended, and 50 g portions were dispensed into bottles using the spinning riffler. Results from analyses at NIST indicated that material homogeneity was acceptable (see below).

Homogeneity Testing: The homogeneity was assessed for elements in the bottled material using instrumental neutron activation analysis (INAA). The estimated relative standard deviation for material inhomogeneity is ≤1 % for most elements evaluated. For antimony, magnesium, and zinc, a component for material heterogeneity (of 1 %, relative, at the 1s level) was included in the expanded uncertainties of the certified values.

Particle Size Measurements: Particle size measurements for SRM 2711a were made using a Malvern Mastersizer 3000 laser-based light scattering system and the particle size distribution is shown in Figure 1.

Analysis: Analyses of this material were performed at NIST and at the USGS (Denver, CO). Results from NIST were used to provide the certified, reference, and information values shown in Tables 1, 2, and 3, respectively. Results from the USGS were used to confirm those values. The analytical techniques used for each element are listed in Table 4; the analysts are listed in Tables 5 and 6.

(1) Certain commercial equipment, instruments, or materials are identified in this certificate in order to specify adequately the experimental procedure. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.

SRM 2711a Page 3 of 7

Table 1. Certified Values(a,b) (Dry-Mass Basis) for Elements in SRM 2711a

Element Mass Fraction

Coverage Factor, k

Element Mass Fraction (mg/kg)

Coverage Factor, k

Aluminum (Al) 6.72 ± 0.06 2.10 Antimony (Sb) 23.8 ± 1.4 2.06 Calcium (Ca) 2.42 ± 0.06 2.10 Arsenic (As) 107 ± 5 2.18 Iron (Fe) 2.82 ± 0.04 2.36 Barium (Ba) 730 ± 15 2.26 Lead (Pb) 0.140 ± 0.001 2 Cadmium (Cd) 54.1 ± 0.5 2 Magnesium (Mg) 1.07 ± 0.06 2.23 Chromium (Cr) 52.3 ± 2.9 2.31 Potassium (K) 2.53 ± 0.10 2.36 Cobalt (Co) 9.89 ± 0.18 2.07 Silicon (Si) 31.4 ± 0.7 2.57 Copper (Cu) 140 ± 2 2.09 Sodium (Na) 1.20 ± 0.01 2.07 Manganese (Mn) 675 ± 18 2.06 Titanium (Ti) 0.317 ± 0.008 2.26 Mercury (Hg) 7.42 ± 0.18 2 Nickel (Ni) 21.7 ± 0.7 2.16 Phosphorus (P) 842 ± 11 2.09 Samarium (Sm) 5.93 ± 0.28 2.78 Strontium (Sr) 242 ± 10 2.45 Uranium (U) 3.01 ± 0.12 2.10 Vanadium (V) 80.7 ± 5.7 2.18 Zinc (Zn) 414 ± 11 2.05

(a) Certified values for all elements except cadmium, lead, and mercury are the equally weighted means of results from two or three analytical methods. The uncertainty listed with each value is an expanded uncertainty about the mean. The expanded uncertainty is calculated as U = kuc, where uc is intended to represent, at the level of one standard deviation, the combined effect of between-method and within-method components of uncertainty, following the ISO/JCGM Guide [3,4]. A component for material heterogeneity is incorporated into the uncertainties for antimony, manganese, and zinc. The coverage factor, k is determined from the Student's t-distribution corresponding to the appropriate associated degrees of freedom and approximately 95 % confidence for each analyte.

(b) The certified values for cadmium, lead, and mercury are each results from a single NIST method (see Table 4) for which a complete evaluation of all sources of uncertainty has been performed. The uncertainty provided is an expanded uncertainty about the mean to cover the measurand with approximately 95 % confidence, consistent with the ISO/JCGM Guide [4]. The expanded uncertainty is calculated as U = kuc, where uc is the combined uncertainty that incorporates within-method uncertainty and Type B uncertainty components related to the analysis, and k is the coverage factor corresponding to approximately 95 % confidence for each analyte.

Table 2. Reference Values(a) (Dry-Mass Basis) for Elements in SRM 2711a

(mg/kg)

Cesium (Cs) 6.7 ± 0.2 Europium (Eu) 1.1 ± 0.2 Hafnium (Hf) 9.2 ± 0.2 Lanthanum (La) 38 ± 1 Neodymium (Nd) 29 ± 2 Rubidium (Rb) 120 ± 3 Scandium (Sc) 8.5 ± 0.1 Thorium (Th) 15 ± 1

(a) Reference values are based on results from one analytical method at NIST (see Table 4). Uncertainty values represent the expanded uncertainties about the mean to cover the measurand with approximately 95 % confidence, consistent with the ISO/JCGM Guide [4]. The expanded uncertainty is calculated as U = kuc, where uc is the combined uncertainty that incorporates within-method uncertainty and type B uncertainty components related to the analysis, and k is the coverage factor (k = 2) corresponding to approximately 95 % confidence for each analyte.

SRM 2711a Page 4 of 7

Table 3. Information Values(a) (Dry-Mass Basis) for Elements in SRM 2711a

Boron (B) 50 Cerium (Ce) 70 Dysprosium (Dy) 5 Gadolinium (Gd) 5 Indium (In) 1 Lutetium (Lu) 0.5 Selenium (Se) 2 Silver (Ag) 6 Tantalum (Ta) 1 Terbium (Te) 0.8 Thallium (Tl) 3 Ytterbium (Yb) 3

(a) Information values are based on results from one analytical method at NIST.

SUPPLEMENTAL INFORMATION FOR SRM 2711a

Particle Size Measurements: Particle size measurements for SRM 2711a were made using a Malvern Mastersizer 3000 laser-based light scattering system. Approximately 0.5 g of SRM 2711a material was measured using water as the dispersant (refractive index 1.330). Sample was introduced into the measurement cell before ten individual measurements were made at an obscuration of 20 % – 21 % of the laser beam. The calculated 10th (Dv10), 50th (Dv50) and 90th (Dv90) percentile particle sizes are Dv(10) = 2.26 µm, Dv(50) = 15.5 µm, and Dv(90) = 58.6 µm. The volume fraction of material smaller than 10.1 µm in diameter is approximately 41 %. The particle size distribution is shown in Figure 1.

Figure 1. Particle size distribution in SRM 2711a

SRM 2711a Page 5 of 7

Table 4. NIST Methods(a,b) Used for the Analysis of SRM 2711a

Element Methods Element Methods

Ag INAA Mn INAA; XRF Al INAA; XRF Na INAA; XRF As INAA; XRF Nd INAA B PGAA Ni ICP-MS; ICP-OES Ba ICP-OES; INAA: XRF P ICP-OES; XRF Ca INAA; XRF Pb ID-ICP-MS Cd ID-ICP-MS Rb INAA Ce INAA Sb ICP-MS; INAA Co INAA; ICP-OES Sc INAA Cr INAA; XRF Se CCT-ICP-MS Cs INAA Si PGAA; XRF Cu ICP-OES; ICP-MS Sm INAA(c); PGAA Dy INAA Sr ICP-OES; INAA; XRF Eu INAA Ta INAA Fe INAA; PGAA; XRF Tb INAA Gd PGAA Th INAA Hf INAA Ti INAA; PGAA; XRF Hg CV-ID-ICPMS Tl ICP-MS In INAA U ICP-MS; INAA

K INAA; PGAA; XRF V INAA; XRF

La INAA(c) Yb INAA Lu INAA Zn INAA; XRF Mg INAA; XRF

(a) NIST Methods of Analysis:

CCT-ICP-MS Collision Cell Inductively Coupled Plasma Mass Spectrometry CV ID-ICP-MS Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry ICP-MS Inductively Coupled Plasma Mass Spectrometry ICP-OES Inductively Coupled Plasma Optical Emission Spectrometry ID-ICP-MS Isotope Dilution Inductively Coupled Plasma Mass Spectrometry INAA Instrumental Neutron Activation Analysis PGAA Prompt Gamma-Ray Activation Analysis XRF X-ray Fluorescence Spectrometry

(b) USGS Methods of Analysis (used to confirm results from certification methods).

WD-XRF Wavelength Dispersive X-ray Fluorescence Spectrometry ICP-OES Inductively Coupled Plasma Optical Emission Spectrometry ICP-MS Inductively Coupled Plasma Mass Spectrometry

(c)Two different INAA experiments, performed using different sub-samples and different analytical conditions, were used to provide certified and reference values for lanthanum and samarium, respectively.

Table 5. Participating NIST Analysts:

S.J. Christopher J.L. Molloy S.A. Rabb B.E. Tomlin R.D. Day K.E. Murphy J.R. Sieber L.J. Wood S.E. Long J.M. Ness R.O. Spatz L.L. Yu E.A. Mackey R.L. Paul R.S. Popelka-Filcoff R. Zeisler A.F. Marlow

Table 6. Participating USGS Laboratory and Analysts

Laboratory Analysts

U.S. Geological Survey Branch of Geochemistry (Denver, CO)

M.G. Adams; Z.A. Brown; P.L. Lamothe;

J.E. Taggart; S.A. Wilson

SRM 2711a Page 6 of 7

REFERENCES

[1] Thompson, A.; Taylor, B.N.; Guide for the Use of the International System of Units (SI), NIST Special

Publication 811 (2008); available at https://www.nist.gov/pml/special-publication-811 (accessed May 2022).

[2] May, W.E.; Gills, T.E.; Parris, R.; Beck, II, C.M.; Fassett, J.D.; Gettings, R.J.; Greenberg, R.R.;

Guenther, F.R.; Kramer, G.; MacDonald, B.S.; Wise, S.A.; Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements; NIST Special Publication 260-136 (2000); available at https://www.nist.gov/system/files/documents/srm/SP260- 136.PDF (accessed May 2022).

[3] Levenson, M.S.; Banks, D.L.; Eberhardt, K.R.; Gill, L.M.; Guthrie, W.F.; Liu, H.K.; Vangel, M.G.; Yen, J.H.;

Zhang, N.F.; An Approach to Combining Results from Multiple Methods Motivated by the ISO GUM; J. Res.

Natl. Inst. Stand. Technol., Vol. 105, pp. 571-579 (2000).

[4] JCGM 100:2008; Evaluation of Measurement Data - Guide to the Expression of Uncertainty in Measurement; (GUM 1995 with Minor Corrections), Joint Committee for Guides in Metrology (JCGM) (2008);

available at https://www.bipm.org/en/committees/jc/jcgm/publications (accessed May 2022); see also Taylor, B.N.; Kuyatt, C.E.; Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, NIST Technical Note 1297, U.S. Government Printing Office, Washington, DC (1994); available at https://www.nist.gov/pml/nist-technical-note-1297 (accessed May 2022).

Certificate Revision History: 02 May 2022 (Editorial changes); 29 October 2018 (Updated uncertainty calculation information; added particle size distribution; change of expiration date; editorial changes); 22 May 2009 (Original certificate date).

Users of this SRM should ensure that the Certificate of Analysis in their possession is current. This can be accomplished by contacting the SRM Program: telephone (301) 975-2200; e-mail srminfo@nist.gov; or via the Internet at https://www.nist.gov/srm.

https://www.nist.gov/pml/special-publication-811 https://www.nist.gov/system/files/documents/srm/SP260-136.PDF https://www.nist.gov/system/files/documents/srm/SP260-136.PDF https://www.bipm.org/en/committees/jc/jcgm/publications https://www.nist.gov/pml/nist-technical-note-1297 mailto:srminfo@nist.gov https://www.nist.gov/srm

SRM 2711a Page 7 of 7

Appendix A

Leachable Concentrations Determined Using USEPA Methods 200.7 and 3050B NIST Methods of Analysis

The mass fraction values contained in the NIST Certificate of Analysis for SRM 2711a represent the total element content of the material. The measurement results used to provide the certified, reference or information values are obtained from methods that require complete sample decomposition, or from nondestructive analytical methods such as instrumental neutron activation analysis or prompt gamma-ray activation analysis. Where complete sample decomposition is required, it can be accomplished by digestion with mixed acids or by fusion. For mixed-acid decomposition, hydrofluoric acid must be included in the acid mixture used to totally decompose siliceous materials such as soils and sediments.

In its monitoring programs, the U.S. Environmental Protection Agency (USEPA) has established a number of leach methods for the preparation of soils samples for the determination of extractable elements. Six laboratories participated, five of which used USEPA Method 200.7; the remaining laboratory used USEPA SW-846 Method 3050B for preparation of soil samples. All elements were determined in leachates by inductively coupled plasma optical emission spectrometry. All laboratories provided individual results from duplicate portions, and these results were averaged together to provide one result for each element from each participating laboratory. Results rejected as outliers by the USEPA Contract Laboratory Program (CLP) officials were not included. Results are summarized in Table A1. The ranges of mass fraction values, median values (to two significant figures), and the number of results included for each are given for 23 elements. The percent recovery values based on the ratios of the median values to the total element content (from the certified, reference, or information values in the Certificate of Analysis) are listed in the last column of Table A1. Note that the certified values provided as total mass fractions in the Certificate of Analysis are the best estimate of the true mass fraction values for this material.

This USEPA CLP Study was coordinated by C. Jones, Quality Assurance and Technical Support Program (QATS), Shaw Environmental & Infrastructure Group, Las Vegas, NV, under the direction of J. Nebelsick, USEPA, Analytical Services Branch. The participating laboratories are listed below the table.

Table A1. Results from Laboratories Participating in the EPA Contract Laboratory Program Study.

Element n Range

Median (mg/kg)

Recovery

Aluminum 6 9800 – 15000 13200 19 Antimony 6 2.8 – 7.2 4.9 21 Arsenic 6 81 – 110 89 85 Barium 6 170 – 200 190 25 Beryllium 6 0.73 – 1.1 0.93 -- Cadmium 6 43 – 56 47 90 Calcium 6 14000 – 17000 14000 61 Chromium 6 12 – 18 15 29 Cobalt 6 5.5 – 9.0 7.5 75 Copper 6 120 – 160 130 95 Iron 6 14000 – 18000 15000 54 Lead 6 1100 – 1400 1300 91 Magnesium 6 5000 – 6600 5700 54 Manganese 6 450 – 580 460 71 Mercury 6 6.3 – 8.3 7.4 100 Nickel 6 13 – 18 15 72 Potassium 6 3300 – 4600 3900 16 Selenium 5 1.4 – 1.9 1.7 85 Silver 6 4.0 – 6.1 5.5 89 Sodium 5 140 – 210 180 1.5 Thallium 5 0.71 – 3.1 2.1 68 Vanadium 6 24 – 34 28 36 Zinc 6 310 – 380 350 85

List of CLP and non–CLP Participating Laboratories: A4 Scientific, Inc.; Bonner Analytical Testing Co.; Chem Tech Consulting Group; Datachem Laboratories, Inc.; Liberty Analytical Corporation; MSE Laboratory Services; Shealy Environmental; SVL Analytical Inc.

Moderately Elevated Trace Element Concentrations
SOURCE, PREPARATION, AND ANALYSIS

File details come from the government source that posted it. Updated .