Amendment I.docx

DOCX document 70 KB Posted

Attached to
VACUUM JACKETED (VJ) PIPING Federal contract opportunity
Solicitation number
1333ND21QNB610171
Issued by
Department of Commerce National Institute of Standards and Technology

View the file

Other files for this federal contract opportunity

Other files attached to VACUUM JACKETED (VJ) PIPING, newest first.
File Type Posted
A-2 Statement of Work for Vacuum Jacketed Piping - Rev 2.docx DOCX document
002-3265 R1.1.pdf PDF
A-2 Statement of Work for Vacuum Jacketed Piping.docx DOCX document
B-2 Final RFQ.docx DOCX document
002-3266 R1.1.pdf PDF
002-3278 R1.1.pdf PDF
002-3267 R1.1.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT I 1333ND21QNB610171 VACUUM JACKETED (VJ) PIPING

The purpose of this Amendment is to address vendor questions and answers (see below) and update the Statement of Work (see attachment (Rev 2)).

Question: On drawing 002-3266 with a branch including an 1-1/2” valve and 1-1/2 x 3” female bayonet can the branch inner line be 1-1/2” NPS Sch 10 pipe to match with these components?

Answer: The drawings indicate that the bayonet on that branch is indicated as an HPBF-20, which is a 2” model (circled in red below).

Question: What are the ID’s of the lines?

Answer: The line size is generally dictated by the bayonets and the control valves. The bayonets have weld joints that are dimensionally matched to a standard pipe schedule to make the welding easier. So, the contractor should start with the dimensions of those items and work their way through the spool picking the appropriate pipe and fitting sizes. Please refer to Section 2 in the Statement of Work. The Government has indicated the bayonet sizes, required instrumentation, and the envelope on the layout drawings. It is up to the Contractor to develop the technical approach and provide a detailed design. Therefore, the Contractor shall choose the appropriate details, like the line ID’s.

Question: What is the part number for the Lakeshore temperature sensor?

Answer: Please see updated Statement of Work (Rev 2) The original Statement of Work is hereby replaced by Revision 2. All other terms and conditions remain unchanged.