This document contains minimum technical requirements for a power supply unit to be integrated into the NEXRAD Doppler Meteorological Radar's Signal Processor Interface Panel (SPIP) operated by the National Weather Service (NWS).

The required power supply must be an enclosed unit rated for 28 VDC output at 12 amperes, with single-phase input capability across 85–265 VAC at 47–63 Hz. The equipment must measure 4.25" wide by 4.75" high by 10.25" deep and operate within a temperature range of -20°C to +50°C using forced-air cooling. The preferred configuration is equivalent to the TDK (Lambda) LZSA-500-3 model, though the Government will accept direct form, fit, and function equivalents that satisfy all stated requirements. Critical features include compliance with MIL-STD-810 shock and vibration standards, protection against electromagnetic interference and lightning-induced surges suitable for radar environments, UL and/or CSA recognized safety certifications, and a minimum five-year manufacturer warranty. The power supply must be new, unused equipment only.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEXRAD SPIP POWER SUPPLY MINIMUM TECHNICAL REQUIREMENTS

The National Weather Service (NWS) is seeking a power supply suitable for use within the NEXRAD Doppler Meteorological Radar's Signal Processor Interface Panel (SPIP). The preferred configuration is equivalent to the TDK (Lambda) LZSA-500-3, including overall form, fit, function, and physical dimensions. However, the Government will accept direct form, fit, and function equivalent products that meets the following requirements.

ITEM DESCRIPTION MINIMUM REQUIREMENT

Equipment Type Enclosed Power Supply

OUTPUT VOLTAGE RATING 28 VDC

OUTPUT CURRENT RATING 12 A

Input Voltage Range 85 – 265 VAC

Input Frequency 47 – 63 Hz

Input Single phase

Features Complies with MIL-STD-810 Shock and Vibration standard

Operates in radar environment and provides protection against electromagnetic interference, transients, and lightning-induced surges

Cooling Forced Air

Size (W x H x D) 4.25” x 4.75” x 10.25”

Operating Temperature Range -20˚C to +50˚C

Safety Certification UL and/or CSA recognized components

Condition New, unused equipment only

Warranty Minimum five (5) year manufacturer warranty