12970224Q0047 RFQ Q_A_ .pdf
PDF 251 KB Posted
- Attached to
- Water Developments Piping Fittings
- Solicitation number
- 12970224Q0047
- Issued by
-
Department of Agriculture Forest Service
About this file
This document is a set of questions and answers related to Solicitation Number 12970224Q0047, a Request for Quotation (RFQ) for commercial supplies of various pipe and pipe fittings to support post-fire recovery operations in the Pecos/Las Vegas District of the Santa Fe National Forest.
The RFQ is seeking bids for the following items: 2 3/8" drill stem pipe, polyethylene pipe, stainless steel pipe couplings, and stainless steel 90-degree elbows. The pipe diameters are specified as outside diameter (OD). The steel pipe is not required to be threaded or stainless steel. The polyethylene pipe is for gravity-fed spring water lines and is not pressurized. The agency has provided clarification on the acceptable pipe lengths, fittings, and materials. No specific performance or service requirements are included, as this appears to be focused on the procurement of commercial off-the-shelf pipe and fittings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| PIPE FITTINGS - SOI.pdf | ||
| SOL 12970224Q0047.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation Number: 12970224Q0047
Commercial Supplies RFQ
12970224Q0047
Santa Fe Disaster Recovery ISSUED: June 28, 2024
8 July 2024
Question 1: Are the pipe diameters given, Inside Diameter (ID) or Outside Diameter (OD)?
Answer: Steel pipe. Pipe diameter is OD.
Question 2: Are the pipe to be potable water rated?
Answer: No. Will be used for livestock waterlines.
Question 3: Steel Pipe any requirements?
Answer: 2 3/8” Oil Field pipe (CLEAN).
Question 5: Items 1 & 2: Is there a minimum continuous length for the Steel Pipe or Polypipe?
Answer: Item #1 is 2 3/8” drill stem pipe and usually comes in 31’ joints. Item #2 is Polypipe and will accept continuous coils of 100’ or 500’.
Question 6: Item 3: do you have a reference part number? Is it a half coupling or full coupling?
Answer: No. Only have a picture of the full SS coupling.
Question 7: Item 4: do you have a reference part number?
Answer: No. Only have a picture of the SS insert 90‐degree elbow.
Question 8: Does steel pipe need to be threaded?
Answer: No.
Question 9: Steel Pipe comes in 21' sections, and I will be quoting 1050' of pipe. Is this okay with your agency?
Answer: No. 2 3/8” drill stem pipe and usually comes in 31’ joints.
Question 10: The poly pipe comes in 200' & 400" rolls, any preference?
Answer: No
Question 11: Item 1: What schedule steel pipe is needed?
Answer: 2 3/8” drill stem pipe
Question 12: Item 2: What kind of system is this pipe being used in? What are the temperatures, pressures, and media for this pipe? Is this HDPE pipe? Do you have a spec?
Answer: Will be used for livestock waterlines. Mainly gravity fed springs.
Question 13: Item 3: What pressure are these? What connection type are these? If these are SS is the
Item 1 pipe also stainless.
Answer: See response 6 & 7.
Question 14: Item 4: What pressure are these? By insert do you mean SW?
Answer: None pressurized.
Question 15: Steel pipe: please provide specification for the type of pipe required, ie, is pipe schedule 10, 20, 40 or 80. is the pipe a53? is pipe
ERW or seamless, and is it black or galvanized? is it plain end or threaded?
Answer: Item #1 is 2 3/8” drill stem pipe and usually comes in 31’ joints. Some are threaded and some are not.
Question 16: Polypipe: is this for irrigation, gas, or other service? what is the service rating required? What astm designation is required? please provide model no of Polypipe to be provided.
Answer: Polypipe is for gravity fed spring water lines. Not pressurized
Question 17: Please clarify the type of coupling and elbow required and what type of piping system they are to be installed in.
Answer: Gravity fed spring water lines. Not pressurized. Couplings and elbows are to connect Polypipe to drinking tanks and collection source.
Question 18: Is the pipe that is referenced as 2 3/8" Pipe just 2" ID Threaded Galvanized water pipe?
Answer: No. 2 3/8” drill stem pipe and usually comes in 31’ joints.
Question 19: In regard to the 2 3/8" the quantity is for 1000ft is that to be cut into specified lengths?
and if so, what are those lengths?
Answer: No. 2 3/8” drill stem pipe and usually comes in 31’ joints.
Question 19: is the first item, 2 3/8" for carbon steel pipe? Std wall? A53 or A106?
Answer: No. 2 3/8” drill stem pipe (clean).
Question 20: If it's stainless pipe, do you require 304 or 316? Same for the stainless 90 elbow, 304 or
316? I've attached our CS for your reference.
Answer: No stainless steel.
File details come from the government source that posted it. Updated .