12905B24Q0246 Specifications.pdf
PDF 47 KB Posted
- Attached to
- Mouse Caging System Federal contract opportunity
- Solicitation number
- 12905B24Q0246
About this file
This document is a set of technical specifications for a solicitation to procure additional individually ventilated caging systems (IVCs) for mice to support research at the Poisonous Plant Research Lab. The required system must be compatible with the lab's existing Tecniplast airhandler and caging system. Key requirements include: an air handling unit with a control panel to provide a stable environment for up to 320 cages; 220 cages with bottoms, tops, water bottles, feed trays and filters; three single-sided racks that can hold 60-80 cages each; and certification to ISO 9001 and ISO 14001 quality and environmental standards. The solicitation number is 12905B24Q0246, with a response due date of August 24, 2024. The contracting agency is the Department of Agriculture Agricultural Research Service Pacific West Area. Offers will be evaluated based on the criteria provided in the attached RFQ terms and conditions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ - 12905B24Q0246 Terms and Conditions.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS -12905B24Q02146
ARS has a need for additional individually ventilated caging systems (IVCs) for mice to support our research. The Poisonous Plant Research Lab currently owns a Tecniplast airhandler and caging system. The new system must be compatible with the current system to facilitate studies and to ensure that the results are comparable.
The system must offer protection for operators and animals. The seal system of the individual cages must not have latches and must have silicon gasketed valves (not invasive to the cage), bottle cap, cage base and filter retainer ensure maximum sealing.
We are requesting an air handling unit that has a control panel to control basic functions. The air handling unit will provide air and support 4 single sided racks or two double sided racks for mice (up to 320 cages supported). The air handler unit will provide a stable environment to the cages in terms of temperature and air exchanges. Air handler will be controlled through a touch pad microprocessor system. The air handler will not transmit vibrations to the rack thus limiting stress to the animals.
We are requesting 220 cages with bottoms and tops, as well as water bottles, feed trays and filters for each cage. Individual cages have a measured floor area at a minimum of 77.66 inches2.
We are requesting three single sided racks, two racks that can hold 80 cages (8 wide, 10 high) and one rack that can hold 60 cages (6 wide and 10 high).
Quality system and Environmental system must be certified by DNV GL = ISO9001 and DNV GL = ISO 14001, respectively.