CR1000__Measurement_and_Control_Datalogger.pdf
PDF 1 MB Posted
- Attached to
- Soil Moisture Profile Sensors w/SoilVUE10 Cables, Measurement & Control Dataloggers and Accessories
- Solicitation number
- 12905B19R2439
About this file
CR1000
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8/6/2019 CR1000: Measurement and Control Datalogger https://www.campbellsci.com/cr1000 1/17
CR1000
Measurement and Control Datalogger
Data Loggers / CR1000
Rugged Data Logger Multipurpose data logger for monitoring and control
Read More
Overview The CR1000 is our most widely used data logger. It can be used in a broad range of measurement and control functions. Rugged enough for extreme conditions and reliable enough for remote environments, it is also robust enough for complex configurations. Used in applications all over the world, it will be a powerful core component for your data-acquisition system.
Benefits and Features Ideal applications include fire weather, mesonet systems, wind profiling, weather stations, air quality, ETo/agriculture, soil moisture, water level/stage, aquaculture, avalanche forecasting, time-domain reflectometry, vehicle testing, SCADA, and water quality
Serial communications with serial sensors and devices supported via I/O port pairs
Collects and stores data and controls peripherals as the brain of your system
Flexible power and communication options make it ideal for remote locations.
4-MB memory can be expanded with add-on memory systems.
Supports PakBus, Modbus, SDI-12, and DNP3 protocols
Compatible with channel expansion peripherals allowing you to expand your system
Quick Links https://www.campbellsci.com/order/cr1000 https://www.campbellsci.com/questions?source=cr1000 https://www.campbellsci.com/data-loggers https://www.campbellsci.com/order/cr1000 https://www.campbellsci.com/questions?source=cr1000 https://www.campbellsci.com/cr1000 2/17
Program with LoggerNet, PC400, or Short Cut to fit your setup
Communicates via various options: TCP/IP, email, FTP, web server.
Gas Discharge Tube (GDT) protected inputs
Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
Program and control on site with addition of CR1000KD keyboard and display unit.
Contains custom ASIC chip that expands pulse count, control port, and serial communications capabilities
Please be advised that Campbell Scientific is nearing discontinuation of the CR1000 Measurement and Control Datalogger. The CR1000 will be available for order through 31 Jan 2020. You will not be able to purchase a CR1000 after this date. Refer to the CR1000 Discontinuation Notice for details.
Images
Quick Links https://s.campbellsci.com/documents/us/miscellaneous/cr1000-discontinuation-notice.pdf https://www.campbellsci.com/cr1000 3/17
CAD Files:
CR1000 2D drawing (PDF) CR1000 2D drawing (DXF)
Similar Products
CR800 Measurement and Control Datalogger
Konect GDS Konect Global Data Services
CR850 Measurement and Control Datalogger with Built-in Keyboard and Display
CR6 Measurement and Control Datalogger https://www.campbellsci.com/download?dl=engineering&file=Cqk%3D https://www.campbellsci.com/download?dl=engineering&file=Cqc%3D https://www.campbellsci.com/cr800 https://www.campbellsci.com/cr800 https://www.campbellsci.com/konectgds https://www.campbellsci.com/konectgds https://www.campbellsci.com/cr850 https://www.campbellsci.com/cr850 https://www.campbellsci.com/cr6 https://www.campbellsci.com/cr6 https://www.campbellsci.com/cr1000 4/17
CR1000X Measurement and Control Datalogger
Detailed Description The CR1000 consists of a measurement and control module and a wiring panel. This data logger uses an external keyboard/display and power supply. Low power consumption allows the CR1000 to operate for extended time periods on a battery recharged with a solar panel—eliminating the need for AC power. The CR1000 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.
The CR1000's module measures sensors, drives direct communications and telecommunications, reduces data, controls external devices, and stores data and programs in on-board, non-volatile storage. The electronics are RF shielded and glitch protected by the sealed, stainless-steel canister.
A battery-backed clock assures accurate timekeeping. The module can simultaneously provide measurement and communication functions. The on-board, BASIC-like programming language supports data processing and analysis routines.
The CR1000WP is a black, anodized aluminum wiring panel that is compatible with all CR1000 modules. The wiring panel includes switchable 12 V, redistributed analog grounds (dispersed among analog channels rather than grouped), unpluggable terminal block for 12 V connections, gas-tube spark gaps, and 12 V supply on pin 8 to power our COM-series phone modems and other peripherals. The control module easily disconnects from the wiring panel allowing field replacement without rewiring the sensors.
Originally, the standard CR1000 had 2 MB of data/program storage, and an optional version, the CR1000-4M, had 4 MB of memory. In September 2007, the standard CR1000 started having 4 MB of memory, making the CR1000-4M obsolete. Data loggers that have a module with a serial number greater than or equal to 11832 will have a 4 MB memory. The 4 MB data loggers will also have a sticker on the canister stating “4M Memory”.
Specifications
-NOTE- Additional specifications are listed in the CR1000 Specifications Sheet.
https://www.campbellsci.com/cr1000x https://www.campbellsci.com/cr1000x https://s.campbellsci.com/documents/us/product-brochures/s_cr1000.pdf https://www.campbellsci.com/cr1000 5/17
Operating Temperature Range -25° to +50°C (standard)
-55° to +85°C (extended)
Non-condensing environment
Analog Inputs 16 single-ended or 8 differential (individually configured)
Pulse Counters 2
Voltage Excitation Terminals 3 (VX1 to VX3)
Communications Ports CS I/O
RS-232
Parallel peripheral
Switched 12 Volt 1 terminal
Digital I/O Certain digital ports can be used to count switch closures.
8 I/Os or 4 RS-232 COM I/O ports can be paired as transmit and receive for measuring smart serial sensors.
Input Limits ±5 Vdc
Analog Voltage Accuracy ±(0.06% of reading + offset) at 0° to 40°C
ADC 13-bit
Power Requirements 9.6 to 16 Vdc
Real-Time Clock Accuracy ±3 min. per year (Correction via GPS optional.)
Internet Protocols FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP
Communication Protocols PakBus, Modbus, DNP3, SDI-12, SDM
Warranty 3 years
Battery-backed SRAM for CPU Usage & Final Storage
4 MB
Idle Current Drain, Average < 1mA (@ 12 Vdc) https://www.campbellsci.com/cr1000 6/17
Active Current Drain, Average 1 mA (1 Hz sample rate @ 12 Vdc without RS-232 communication)
16 mA (100 Hz sample rate @ 12 Vdc without RS-232 communication)
28 mA (100 Hz sample rate @ 12 Vdc with RS-232 communication)
Dimensions 23.8 x 10.1 x 5.4 cm (9.4 x 4.0 x 2.1 in.)
25.2 x 10.2 x 7.1 cm (9.9 x 4.0 x 2.8 in.) with CFM100 or NL116 attached
Weight 1.0 kg (2.1 lb) https://www.campbellsci.com/cr1000 7/17
Compatibility Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Software
Product Compatible Note
LOGGERNET Version 3.0 or higher
PC200W
PC400 Version 1.2 or higher
PCONNECT (retired) Version 3.1 or higher
PCONNECTCE (retired) Version 2.0 or higher
RTDAQ Version 1.0 or higher
Short Cut
VISUALWEATHER Version 2.0 or higher
Additional Compatibility Information
Sensors With several channel types, the CR1000 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors (via a terminal input module, such as the CURS100). A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR1000's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices.
Measurement & Control Peripherals The CR1000 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays.
Communications The CR1000 communicates with a PC via direct connect, Ethernet interfaces, multidrop modems, short-haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos, Iridium, and Inmarsat).
Data can be viewed on the CR1000KD Keyboard Display, the CD100 Mountable Display with Keyboard, an iOS or Android device (requires LoggerLink), CD295 DataView II Display, or a user-supplied PDA (PConnect or PConnectCE software required).
Compatible external data storage devices are the CFM100, NL115, and SC115.
https://www.campbellsci.com/loggernet https://www.campbellsci.com/pc200w https://www.campbellsci.com/pc400 https://www.campbellsci.com/pconnect https://www.campbellsci.com/pconnectce-pocketpc-winmobile https://www.campbellsci.com/rtdaq https://www.campbellsci.com/shortcut https://www.campbellsci.com/visualweather https://www.campbellsci.com/curs100 https://www.campbellsci.com/cr1000 8/17
Enclosures The CR1000 and its power supply can be housed in any of our standard enclosures.
Power Any 12 Vdc source can power the CR1000 datalogger. Power supplies commonly used with the CR1000 are the BPALK, PS150, and PS200. The BPALK provides eight non-rechargeable D-cell alkaline batteries with a 7.5 Ah rating at 20°C.
Both the PS150 and PS200 consist of a sealed rechargeable 7 Ah battery and a charging regulator.
Their battery should be connected to a charging source (either a wall charger or solar panel). These two power supplies differ in their charging regulator. The PS150 has a standard regulator and the PS200 has a micro-controller-based smart regulator. The PS200's regulator provides two-step constant voltage charging and temperature compensation that optimize battery charging and increases the battery’s life.
Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12 and 24 Ah, respectively. These batteries should be connected to a regulated charging source (e.g., a CH100 or CH200 connected to a unregulated solar panel or wall charger).
Software CRBasic, the CR1000's full programming language, supports simple or complex programming and many onboard data reduction processes.
Documents
Brochures CR1000 Measurement and Control System
CR1000 Specifications
Manuals CR1000 Measurement and Control System
Technical Papers FTP Streaming
Benefits of Input Reversal and Excitation Reversal for Voltage Measurements
Preventing and Attacking Measurement Noise Problems
DNP3 with Campbell Scientific Dataloggers
Voltage Measurement Accuracy, Self-Calibration, and Ratiometric Measurements
BACnet to Modbus Protocol Conversion (App. Note: 1M-C)
Irrometer 950R1-O/950T Radio Network (App.Note: 3MI-F) https://s.campbellsci.com/documents/us/product-brochures/b_cr1000.pdf https://s.campbellsci.com/documents/us/product-brochures/s_cr1000.pdf https://s.campbellsci.com/documents/us/manuals/cr1000.pdf https://s.campbellsci.com/documents/us/technical-papers/ftp-streaming.pdf https://s.campbellsci.com/documents/us/technical-papers/inputrev.pdf https://s.campbellsci.com/documents/us/technical-papers/mnoise.pdf https://s.campbellsci.com/documents/us/technical-papers/dnp3-protocol.pdf https://s.campbellsci.com/documents/us/technical-papers/voltaccy.pdf https://s.campbellsci.com/documents/us/technical-papers/bacnet.pdf https://s.campbellsci.com/documents/us/technical-papers/irrometer_950r1.pdf https://www.campbellsci.com/cr1000 9/17
AlphaGUARD Radon Monitor Interfaced with the CR1000 Datalogger
Serial Sensors: Interfacing with CSI Dataloggers (App. Note Code: 2MI-V)
CF Card Information (3SM-F)
Case Studies Meteorologia Aeronautica VI - Sao Tome
Compliance CR1000-series EU Declaration of Conformity
Miscellaneous CR1000 Discontinuation Notice
Videos & Tutorials
Overview and Software Setup (QuickStart Part 1) - 5:24
Programming with Short Cut (QuickStart Part 2) - 5:49 https://s.campbellsci.com/documents/us/technical-papers/alphaguard.pdf https://s.campbellsci.com/documents/us/technical-papers/serial.pdf https://s.campbellsci.com/documents/us/technical-papers/pc_cf_cards.pdf https://s.campbellsci.com/documents/us/case-studies/sao_tome.pdf https://s.campbellsci.com/documents/us/compliance/eudoc_cr1000-series.pdf https://s.campbellsci.com/documents/us/miscellaneous/cr1000-discontinuation-notice.pdf https://www.campbellsci.com/videos/overview-and-software-setup-quickstart-part-1 https://www.campbellsci.com/videos/programming-with-short-cut-quickstart-part-2 https://www.campbellsci.com/cr1000 10/17
Use LoggerNet to Send a Program and Collect Data (QuickStart Part 3) - 5:06
Datalogger Programming
View Data Tutorial
Use PC200W to Send a Program and Collect Data (QuickStart Part 4) - 3:44 https://www.campbellsci.com/videos/use-loggernet-to-send-a-program-and-collect-data-quickstart-part-3 https://www.campbellsci.com/videos/datalogger-programming https://www.campbellsci.com/videos/view-data-tutorial https://www.campbellsci.com/videos/use-pc200w-to-send-a-program-and-collect-data-quickstart-part-4 https://www.campbellsci.com/cr1000 11/17
Collect Data Tutorial
CR1000 Datalogger | Wiring Panel - 7:18
Comparing Campbell Scientific Dataloggers - 7:17
Multiplexer Programming with a CR1000 Datalogger - 6:09 https://www.campbellsci.com/videos/collect-data-tutorial https://www.campbellsci.com/videos/cr1000-datalogger-wiring-panel https://www.campbellsci.com/videos/comparing-campbell-scientific-dataloggers https://www.campbellsci.com/videos/multiplexer-programming-with-a-cr1000-datalogger https://www.campbellsci.com/cr1000 12/17
Hughes 9502 Inmarsat BGAN Satellite IP Terminal - 13:08
Connect Window Tutorial
Wiring a Datalogger to a Multiplexer - 7:18
PVS5120-Series Samplers | CR1000 Connection (Part 3) - 3:33 https://www.campbellsci.com/videos/hughes-9502-inmarsat-bgan-satellite-ip-terminal https://www.campbellsci.com/videos/connect-window-tutorial https://www.campbellsci.com/videos/wiring-a-datalogger-to-a-multiplexer https://www.campbellsci.com/videos/pvs5120series-samplers-cr1000-connection-part-3 https://www.campbellsci.com/cr1000 13/17
Downloads CR1000 OS v.32.03 (5.10 MB) 08-13-2018
Execution of this download installs the CR1000 Operating System and Compiler on your computer.
It also updates the CR1000 support files for the CRBasic Editor.
Note: This OS has crossed the 2 Meg CR1000 size limit for remote download. The OS must be downloaded to the 2 Meg CR1000 via direct connect with the Device Configuration Utility. All OS download methods are supported by the 4 Meg CR1000.
Upgrading from versions prior to version 28 of the Operating System will reset the datalogger’s CPU drive. This is due to a change in the format of the file system from FAT16 to FAT32. In order for the datalogger to operate correctly, as part of the upgrade, the CPU drive is formatted to FAT32. Any programs stored and running from the CPU drive will be lost. It is not recommended to update the datalogger’s Operating System over a remote connection where program control regulates the communication equipment (turning it on or off, etc.). In these cases, an on-site visit and a backup using DevConfig’s backup utility is necessary to update the datalogger’s Operating System.
Watch the Video Tutorial: Sending an OS to a Local Datalogger.
In all cases where the datalogger is being updated from an Operating System prior to 28, the use of DevConfig’s backup utility is recommended due to the CPU drive being formatted using the new FAT32 format.
Add to List
View Update History
Device Configuration Utility v.2.21 (41.5 MB) 05-22-2019
A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.
Supported Operating Systems:
Windows 10, 8.1, 8, and 7 (Both 32 and 64 bit)
Add to List
View Update History
Frequently Asked Questions Number of FAQs related to CR1000: 184
Search Related FAQs Search https://www.campbellsci.com/videos/sending-an-os-to-a-local-datalogger-part-1 https://www.campbellsci.com/revisions/103 https://www.campbellsci.com/revisions/83 https://www.campbellsci.com/cr1000 14/17
Expand All
1. How are raw readings produced from half-bridge measurements different between data loggers?
2. Is there anything a CR1000 can do that a CR3000 cannot do?
3. How can variables be saved so that they are available for use after the data logger power has been removed and the data logger has been powered up again?
4. Do the CR800-series, CR1000, and CR3000 dataloggers have 50 Hz versions?
5. Can the CS625 be measured with a CR1000 datalogger?
6. Can a CR1000 be directly connected as a peripheral device to a CR3000 via a serial connection?
7. Is there a sample program available for the CR1000 for eddy-covariance applications?
8. How can an SDM-SIO4 and a CR1000, CR3000, or CR800-series datalogger be used to send a string from the SDM port out?
9. Why might a data logger refuse having a file uploaded to it?
10. Where can processor usage information be found?
View All Related FAQs (184) Visit the FAQ Library
Case Studies Louisiana: Sinkhole Monitoring In August 2012, RESPEC was contracted to provide field instrumentation and early-warning monitoring services at......read more
South Dakota: Rock-Melt Monitoring America currently has an estimated 75,000 tons of spent nuclear fuel housed at dozens of......read more
Delaware River: Bridge Health Intelligent Infrastructure Systems, a Pennoni company, was contracted to design and install an efficient structural-health......read more
Ontario: Solar-Energy Programs With climate change and pollution becoming important issues globally, it is important for governments and......read more https://www.campbellsci.com/faqs?v=564 https://www.campbellsci.com/faqs?v=322 https://www.campbellsci.com/faqs?v=537 https://www.campbellsci.com/faqs?v=340 https://www.campbellsci.com/faqs?v=2188 https://www.campbellsci.com/faqs?v=332 https://www.campbellsci.com/faqs?v=92 https://www.campbellsci.com/faqs?v=727 https://www.campbellsci.com/faqs?v=552 https://www.campbellsci.com/faqs?v=563 https://www.campbellsci.com/faqs https://www.campbellsci.com/louisiana-sinkhole https://www.campbellsci.com/louisiana-sinkhole https://www.campbellsci.com/south-dakota-rock-melt https://www.campbellsci.com/south-dakota-rock-melt https://www.campbellsci.com/delaware-river-bridge https://www.campbellsci.com/delaware-river-bridge https://www.campbellsci.com/ontario-solar-energy https://www.campbellsci.com/ontario-solar-energy https://www.campbellsci.com/cr1000 15/17
New Mexico: Weather Monitoring Chevron Mining, Inc., (CMI) owned and operated a 6.6 million-metric-ton-per-year (6.6 million-U.S.-ton) molybdenum mining and......read more
Chile: Solar-Panel Soiling Valhalla, an energy company in Chile, is making resource assessment and solar-panel soiling measurements in......read more
Illinois: Automating a Data System The McCook Reservoir is a ten-billion-gallon reservoir located in La Grange, Illinois.
The Metropolitan Water......read more
Tasmania: Ecological Research The Warra long-term ecological research (LTER) site located in Southwestern Tasmania was founded in 1995......read more
Explore All Case Studies
Articles and Press Releases Blog Articles
How to Monitor Your Campbell Cellular Modem Data Usage: Part 2 01-30-2019 Author: Nathanael Wright
Campbell Core Technology: Data Logger Analog Measurement Uncertainty 05-17-2018 Author: Kevin Rhodes
New Product Support: Kipp & Zonen’s RaZON+ 01-17-2018 Author: Matt Perry
Integrated Peripherals: Expansion made easy 11-29-2017 Author: Timothy Jeppsen
Replacing Your CR1000 Datalogger with a CR1000X: What You Should Know 10-11-2017 Author: Timothy Jeppsen
A Quick Comparison of the CR1000X, CR1000, and CR6 Dataloggers 08-16-2017 Author: Timothy Jeppsen
Introducing the CR1000X: A New Generation of Data Loggers with Proven Functionality 08-02-2017 Author: Timothy Jeppsen
Sending Email from Your Data Logger Just Got Easier!
01-25-2017 Author: Dana Worley https://www.campbellsci.com/new-mexico-mine-monitoring https://www.campbellsci.com/new-mexico-mine-monitoring https://www.campbellsci.com/chile-solar-panel-soiling https://www.campbellsci.com/chile-solar-panel-soiling https://www.campbellsci.com/illinois-data-system https://www.campbellsci.com/illinois-data-system https://www.campbellsci.com/tasmania-ecological-research https://www.campbellsci.com/tasmania-ecological-research https://www.campbellsci.com/case-studies https://www.campbellsci.com/blog/monitor-cellular-modem-data-usage-part-2 https://www.campbellsci.com/blog/campbell-core-tech-measurement-uncertainty https://www.campbellsci.com/blog/product-support-razonplus https://www.campbellsci.com/blog/integrated-peripherals-easy-expansion https://www.campbellsci.com/blog/replace-cr1000-datalogger-with-cr1000x https://www.campbellsci.com/blog/comparison-cr1000x-cr1000-cr6-dataloggers https://www.campbellsci.com/blog/introducing-cr1000x-datalogger https://www.campbellsci.com/blog/sending-email-from-datalogger https://www.campbellsci.com/cr1000 16/17
Available Security Measures for Internet-Connected Data Loggers 12-07-2016 Author: Dana Worley
Using Internet Data to Promote Outdoor Safety 11-04-2015 Author: Barbra Utley
Newsletter Articles Celebrate with Us! 01-24-2018
Case Study: PGA Tour Lightning Warning System 10-28-2016
Case Study: Preventing Road Damage from Freezing Conditions in South Korea 09-01-2016
Case Study: High-Elevation Weather in Peru 07-21-2016
Case Study: Geothermal Development in Colombia 02-02-2016
Case Study: Dam Monitoring in Puerto Rico 02-02-2016
Case Study: Webcams in New Hampshire Forest 10-15-2015
Case Study: University of Toronto Green Roof Research 07-21-2015
Case Study: Cavern Collapse Alarm 07-21-2015
Case Study: Washington AgWeatherNet 04-14-2015
Case Study: South Africa Solar Prospecting 04-14-2015
Powerful New Operating System for CR800, CR1000, CR3000 02-04-2015
Case Study: Solar-Energy Assessment in Chile 10-20-2014
Case Study: Florida Endangered Species 07-30-2014
Case Study: South Dakota Irrigation Update 07-30-2014
Case Study: Flood Warning in Arkansas 10-15-2013
Case Study: Preventing Road Damage from Freezing Conditions in South Korea 05-09-2013
Case Study: Florida Water Diversion Control 10-18-2012
Case Study: North Carolina “Green” Hotel 10-18-2012
Case Study: Station Provides Flood Warning & Road Weather Data 08-17-2012
Case Study: Researching Glacier Retreat in the Andes 08-17-2012
New Operating System for CR800, CR1000, CR3000 08-17-2012
Case Study: Water-Supply SCADA System 03-15-2012
Case Study: Post-Tensioned, Fiber-Reinforced Bridge 11-16-2011
Press Releases NHRA Acceptance of Campbell Scientific Dataloggers 04-22-2008
More Versatile Channels, Increased Memory: Campbell Scientific’s CR1000 Datalogger 09-06-2005
Quick Links https://www.campbellsci.com/blog/security-measures-for-internet-connected-dataloggers https://www.campbellsci.com/blog/internet-data-for-outdoor-safety https://www.campbellsci.com/news-celebrate-with-us https://www.campbellsci.com/news-pga-tour-lightning-warning https://www.campbellsci.com/news-korean-roadways https://www.campbellsci.com/news-peru-weather https://www.campbellsci.com/news-colombia-geothermal-development https://www.campbellsci.com/news-puerto-rico-dam-monitoring https://www.campbellsci.com/news-data-experimental-forest https://www.campbellsci.com/news-university-toronto-green-roof https://www.campbellsci.com/news-cavern-collapse-alarm https://www.campbellsci.com/news-washington-agweathernet https://www.campbellsci.com/news-south-africa-solar https://www.campbellsci.com/news-powerful-new-os https://www.campbellsci.com/news-chile-solar https://www.campbellsci.com/news-endangered-species https://www.campbellsci.com/news-irrigation-update https://www.campbellsci.com/news-ar-flood-warning https://www.campbellsci.com/news-korean-roadways https://www.campbellsci.com/news-water-diversion https://www.campbellsci.com/news-green-hotel https://www.campbellsci.com/news-colorado-flood-rwis https://www.campbellsci.com/news-peru-glacier https://www.campbellsci.com/news-os25 https://www.campbellsci.com/water-scada https://www.campbellsci.com/gfrp-precast-bridge-article https://www.campbellsci.com/newsroom/nhra-acceptance-of-campbell-scientific-dataloggers https://www.campbellsci.com/newsroom/more-versatile-channels-increased-memory-campbell-scientifics-cr1000-datalogger https://www.campbellsci.com/cr1000 17/17
This Product Replaced
CR10X-2M
CR10
CR1000-4M
Privacy Policy Update
We've updated our privacy policy. Learn More https://www.campbellsci.com/cr10x-2m https://www.campbellsci.com/cr10 https://www.campbellsci.com/cr1000-4m https://www.campbellsci.com/privacy
File details come from the government source that posted it.