PROJECT LOCATION
VICINITY MAP
TRAVEL DIRECTIONS:
SHEET OF
United States Department of Agriculture
Forest Service
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G0.1 COVER SHEET
M0.1
MECHANICAL LEGEND AND
SCHEDULES
M1.1 MECHANICAL FLOOR PLAN
M2.1
ENLARGED MECHANICAL PLANS AND
SECTIONS
M3.1 MECHANICAL SCHEMATICS
M5.1 MECHANICAL DETAILS
M5.2 HVAC UNIT CONTROL SCHEMATIC
M5.3
CONTROL DRAWINGS, SCHEMATICS
AND LEGEND
E0.1
ELECTRICAL LEGEND, SCHEDULES
AND DETAILS
E1.1 ELECTRICAL POWER PLAN
E7.1
ELECTRICAL PANEL SCHEDULES AND
DIAGRAMS
DIRECTIONS: FROM CEDAR CITY, UT DEPART I-15 AT EXIT 59
HEADING WEST TOWARD CEDAR CITY/AIRPORT/SOUTHERN UTAH
UNIVERSITY. TRAVEL 0.3 MILE AND TURN LEFT ONTO UT-56/W 200N.
TRAVEL 0.3 MILES AND TURN RIGHT ONTO N AIRPORT ROAD.
TRAVEL 1.0 MILES AND TURN RIGHT ONTO KITTYHAWK DRIVE.
PROCEED 0.1 MILE TO LOCATION.
ADDRESS: 1770 KITTYHAWK DR, CEDAR CITY, UT 84721.
LATITUDE AND LONGITUDE: 37.696780, -113.084400
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER DATE
DIRECTOR OF ENGINEERING
DATE
FOREST SUPERVISOR DATE
4/3 0/1
9 1 6:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\T 1.D
W G;
CCIFC MECHANICAL MODIFICATIONS
UTAH
IRON COUNTY
DIXIE NATIONAL FOREST
R4 INTERMOUNTAIN REGION
AutoCAD SHX Text
1. DRAWINGS SHOW EXISTING MECHANICAL AND ELECTRICAL SYSTEMS DRAWINGS SHOW EXISTING MECHANICAL AND ELECTRICAL SYSTEMS AND COMPONENTS. WORK ASSOCIATED WITH THIS CONTRACT IS EITHER OUTLINED WITH RED BOXES AND/OR IDENTIFIED BY RED NOTES. ITEMS SHOWN IN BLACK ARE EXISTING. 2. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM GOVERNMENT FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. FIELD VERIFY EXISTING CONDITIONS AND EQUIPMENT SEQUENCE OF OPERATIONS PRIOR TO BEGINNING WORK. BRING DISCREPANCIES TO THE ATTENTION OF THE CONTRACTING OFFICER. 3. PROTECT STRUCTURE AND EQUIPMENT FROM DAMAGE. IMMEDIATELY PROTECT STRUCTURE AND EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED UNDER THIS CONTRACT. 4. DO NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS OR DO NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS OR SERVICE WITHOUT WRITTEN APPROVAL FROM THE CONTRACTING OFFICER.
AutoCAD SHX Text
GENERAL NOTES
tcmichael Rectangle
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/3 /19
0:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
MECHANICAL LEGEND &
SCHEDULES
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M0.1 002 011
Remove and replace hot water coil control valve actuator
Remove and replace Air Cooled Condenser and refrigerant piping.
Install new air cooled condenser and refrigerant piping.
Provide new glycol feeder 1. Remove and replace balancing valves on all hydronic coils.
2. Drain, clean, purge, and pressure test hydronic system.
3. Fill hydronic system with 30/70 glycol/water mix.
4. Test, adjust, and balance all HVAC equipment.1. All VAV boxes: Remove and replace box controller, room thermostat, and discharge air temperature sensor.
2. VAV-5: Remove and replace heating water control valve actuator.
tcmichael Callout Remove and replace Direct Expansion (DX) cooling coil with dual circuited DX cooling coil.
tcmichael Callout ADDITIVE ITEM: Remove and replace exhaust fans EF-1, EF-4, and EF-5. Reconnect to existing ductwork, electrical, and controls.
tcmichael Rectangle tcmichael Rectangle tcmichael Rectangle tcmichael Rectangle tcmichael Line tcmichael Callout ADDITIVE ITEM:Remove and replace relief fans RF-1 and RF-3. Reconnect to existing ductwork, electrical, and controls.
tcmichael Line
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/3 /19
0:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
MECHANICAL FLOOR
PLAN
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M1.1 003 011
Remove and replace ACC-1 and refrigerant piping.
Install new ACC-2 and refrigerant piping.
tcmichael Rectangle tcmichael Rectangle tcmichael Callout See room 024 floor plan and sections on M2.1 for work in this area.
tcmichael Callout See room 009 floor plan on M2.1 for work in this area.
tcmichael Callout See existing and revised refrigerant piping isometrics on M5.2 tcmichael Rectangle tcmichael Rectangle tcmichael Rectangle tcmichael Callout ADDITIVE ITEM: Remove and replace exhaust fans EF-1, EF-4, and EF-5. Reconnect to existing ductwork, electrical, and controls.
tcmichael Line tcmichael Line tcmichael Rectangle tcmichael Rectangle tcmichael Callout ADDITIVE ITEM: Remove and replace relief fan RF-1. Reconnect to existing electrical and controls.
tcmichael Callout ADDITIVE ITEM: Remove and replace relief fan RF-3. Reconnect to existing ductwork, electrical and controls.
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 8/1
9 1 7:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
ENLARGED MECHANICAL
PLANS, AND SECTIONS
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M2.1 004 011
1. Remove and replace balancing valves on all hydronic coils.
2. Drain, clean, purge, and pressure test hydronic system.
3. Fill hydronic system with 30/70 glycol/water mix.
4. Test, adjust, and balance all HVAC equipment.
Remove and replace DX cooling coil with dual circuited DX cooling coil.
Remove and replace control valve actuator.
Remove refrigerant piping. Install two sets of refrigerant piping to new condensing units.
Remove and replace DX cooling coil with dual circuited DX cooling coil.
Remove and replace control valve actuator.
Install glycol feeder.
Outside air damper fails to close at times. Service and adjust damper.
Seal supply duct between flexible connection and air handling unit
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 8/1
9 1 7:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
MECHANICAL
SCHEMATICS
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M3.1 005 011
Install Glycol Feeder, valve and piping.
1. Remove and replace balancing valves on all hydronic coils.
2. Drain, clean, purge, and pressure test hydronic system.
3. Fill hydronic system with 30/70 glycol/water mix.
4. Test, adjust, and balance all HVAC equipment.
Remove and replace balancing valve.
Remove and replace balancing valve.
Remove and replace balancing valve.
Remove and replace balancing valve.
Remove and replace valve actuator tcmichael Callout Remove and replace valve actuator on VAV-5 only
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/4 /19
5:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
MECHANICAL DETAILS
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M5.1 006 011
Remove ACC1 and refrigerant piping
Install new ACC-1, ACC-2 and associated refrigerant piping, valves, and concrete pad
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/4 /19
7:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
HVAC UNIT CONTROL
SCHEMATIC
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M5.2 007 011 tcmichael Callout Replace status sensor. Verify operation.
tcmichael Callout EF-1 Fan shows alarm on graphic interface even when running. Correct control operation tcmichael Rectangle tcmichael Rectangle tcmichael Rectangle tcmichael Callout Revise control sequence for dual circuited DX coil and two condensing units.
tcmichael Text Box
1. Reconnect controls to replaced ACC-1.
2. Provide and install controls for ACC-2 tcmichael Text Box
1. Integrate new control devices with existing control system to accomplish control sequences.
2. Verify and test existing, revised, and new control components.
3. Demonstrate control operation accomplishes control sequence.
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/4 /19
5:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
CONTROL DRAWINGS,
SCHEMATICS AND
LEGEND
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
M5.3 008 011
Remove and replace VAV box controller, room thermostat, and discharge air sensor.
1. Integrate new control devices with existing control system to accomplish control sequences.
2. Verify and test existing, revised, and new control components.
3. Demonstrate control operation accomplishes control sequence.
Provide heating hot water controls to meet revised sequence of operation
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 8/1
9 1 7:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
ELECTRICAL LEGEND,
SCHEDULES AND
DETAILS
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
E0.1 009 011
Drawing provided for general information only.
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/4 /19
5:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
ELECTRICAL POWER
PLAN
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
E1.1 010 011
1, Remove ACC-1 disconnect. Install 60A-3P disconnect with 60 amp fuses. Reconnect power to ACC-1.
2. Install ACC-2 100A-3p disconnect with 80 amp fuses. Route #3 conductors with #8 ground in 1-1/4" conduit to unit and electrical panel.
Replace 125 A-3P circuit breaker with 60A-3P circuit breaker. Install new 80A-3P circuit breaker in space 79, 81, 83.
Install receptacle for glycol feeder. Extend power from existing circuit in surface mounted conduit.
Replace AHU-1 10 hp
VFD
Remove CP-1 and CP-2 heating hot water pump disconnects and starters.
Install 2 HP VFDs.
RF-1 Fan, Replace blown fuse
RF-3 Fan, trips manual starter and sounds bad during operation. Trouble shoot fan tripping and noise and correct.
EF-1 Fan continually trips manual starter and doesn't run. Verify fan current is less than or equal to nameplate rating. Trouble shoot starter tripping and correct.
EF-4 Fan doesn't run. Trouble shoot fan operation and correct tcmichael Text Box General Note:
See M5.2 for fan sensor and interface issues.
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
4/4 /19
6:
T
CM
IC
HA
EL
C :\U
SE
RS
\T
CM
IC
HA
EL
\B
OX
\C
DI
\O
TH
ER
\R 4\C
OL
OR
CO
FI
RE
\20
_M
EC
HM
OD
\D
W
GS
\20
_M
EP
.D W
G;
(R4)
INTERMOUNTAIN REGION
CCIFC
MECHANICAL
MODIFICATIONS
DIXIE NATIONAL FOREST
COLOR COUNTY INTERAGENCY
FIRE CENTER
ELECTRICAL PANEL
SCHEDULES AND
DIAGRAMS
04/08/2019
T.MICHAEL
T.MICHAEL
S.HILL-WORTHEN
E7.1 FS090523_R102013_L1-002.dwg
011 011
Remove 125A-3P breaker. Install 60A-3P breaker
Install 80A-3P breaker
| 2103_001 |
| CCIFC-DWGBinder100 |
| M01 |
| Sheets and Views |
| M01 |
| M11 |
| Sheets and Views |
| M11 |
| M21 |
| Sheets and Views |
| M21 |
| M31 |
| Sheets and Views |
| M31 |
| M51 |
| Sheets and Views |
| M51 |
| M53 |
| Sheets and Views |
| M53 |
| E01 |
| Sheets and Views |
| E01 |
| E11 |
| Sheets and Views |
| E11 |
| E71 |
| Sheets and Views |
| E71 |
| M52.pdf |
| Sheets and Views |
| M52 |
| T1.pdf |
| Sheets and Views |
| 17x11 EXPANDED |
File details come from the government source that posted it.