127EAU26Q0015 Attachment 4 CM Chapter_9_Section_906.pdf

PDF 61 KB Posted

Attached to
Cattleguard Purchase Coconino National Forest
Solicitation number
127EAU26Q0015
Issued by

About this file

This document is a section from a Construction Manual dated January 2005, specifically addressing specifications and inspection guidelines for cattle guards (Section 906). The document outlines that project plans will specify the location and type of cattle guards to be constructed, which must conform to Standard Drawings or special plan details. Cattle guards must be well-drained, constructed to precise grade and cross slope specifications, and installed to provide a smooth, bump-free surface for traffic.

The document provides five detailed inspection guidelines for cattle guards, which include verifying material certifications, checking that steel parts are primed, ensuring backfill material is compacted to at least 95% of maximum density, confirming concrete has been finished and cured according to specifications, and verifying that the grade and cross slope match the finished pavement surface. The guidelines are designed to ensure quality control and proper installation of cattle guards in construction projects.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INCIDENTALS January 2005

906 CATTLE GUARDS

The Project Plans will specify the location and type of cattle guards to be constructed. Each cattle guard must be constructed in conformance with the appropriate Standard Drawings or any special details included in the plans.

The item itself consists of furnishing all materials and constructing new cattle guards or reconstructing existing cattle guards as noted on the plans.

Completed cattle guards must be well-drained to prevent ponding of water in the structure. Cattle guards should be carefully constructed to the specified grade and cross slope, with special care being taken to achieve a bump free, smooth riding installation. Errors in the elevation of the cattle guard or the approach grade that cause a bump for traffic must be corrected.

Inspection Guidelines For Cattle Guards

1. Are material certifications available for those items requiring them? If the unit is precast, does the Certificate of Compliance match the unit and is the unit identified as an ADOT cattle guard?

2. Are the steel parts primed?

3. Has the backfill material been compacted to at least 95% of maximum density?

4. Has the concrete been finished and cured in accordance with the specifications?

5. Does the grade and cross slope conform to the surface of the finished pavement?

Construction Manual 906 - 1