BOM.XLSX

XLSX spreadsheet 31 KB Posted

Attached to
Communications Building, Transportation and Installation Federal contract opportunity
Solicitation number
12760418Q0019
Issued by
Department of Agriculture Forest Service Washington Office Acquisitions

About this file

Bill of materials

View the file

Other files for this federal contract opportunity

Other files attached to Communications Building, Transportation and Installation, newest first.
File Type Posted
PWS.pdf PDF
NEPADocumentsNFVW0518Shelters.pdf PDF
GPATLMRFY18LifeCycle.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Summary

RegionShip toForest/DistrictSITEPOCBOM Amount
R5Klamath NFSalmon Scott RDEddie Gulch 10x18x8 ShelterMatt Holmes$0.00
R9Monongahela NFGauley RDRed Oak 8x10x8 ShelterBrian Post$0.00

TOTALS $0.00

R5 Eddy Gulch 10x18 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R5 Salmon Scott RD, Klamath NF
Point of Contact (Local SAT):Matt Holmes
Phone (Local SAT):
Street Address:1030 South Main St
City, State:Yreka, CA
Zip:96097
Additional Information needed for request.
Project Point of Contact (name and phone):Matt Holmes
Additional Technical Contact (name and phone), if applicable:Tony Martinez
WR # or Incident Number:20182937
Override/Job Code:2505/NFVW0518
Q-CODEQ4900518
UIA1107050549005
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#20182937 001
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton (530)226-2779
Comments:Eddy Gulch communications site Latitude N41 14' 37", Longitude W123 06' 13", Elevation 6500ft. Door location: Southeast, Tower: N/A.
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 10' wide x 18' long x 8' highEA1
3Size Nominal 8'8" Wide Interior x Nominal 16'8" Long x Nominal 8' high interior, one room concrete shelter.$ - 0
4SPECIAL FEATURES:$ - 0
5Bullet proof walls$ - 0
62 hour fire rating$ - 0
7Insulation R20 average throughout.$ - 0
8ROOF AND FLOOR$ - 0
9Roof coating: EPDM$ - 0
10Flooring: Standard tile$ - 0
11INTERIOR WALLS AND CEILING:$ - 0
12FRP (Fiber-Reinforced Plastic) covered plywood$ - 0
13DOOR: Direction East$ - 0
143070 Door, 18 Gauge GalvanizedEA1$ - 0
153070 Frame, 16 Gauge GalvanizedEA1$ - 0
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1$ - 0
17Lock: 626-Entry w/deadbolt functionEA1$ - 0
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1$ - 0
18Latch Protector (SS)EA1$ - 0
19Door PullEA2$ - 0
20Magnetic Weather StrippingEA1$ - 0
21Drip Cap: 76" x 2-1/2"EA1$ - 0
22SS Hinges: Ball BearingEA3$ - 0
23Threshold: Bumper 36"EA1$ - 0
24Threshold: Saddle 36"EA1$ - 0
23CABLE TRAY:$ - 0
2429 linear feet of 12" wide steel cable trays$ - 0
25CABLE ENTRY:$ - 0
268 port cable entry$ - 0
27ELECTRICAL:$ - 0
28120V/240V, 200A, single phase$ - 0
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1$ - 0
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1$ - 0
31GROUNDING:$ - 0
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1$ - 0
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1$ - 0
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1$ - 0
36INTERIOR LIGHTS:$ - 0
3748" 40 wattEA2$ - 0
38RECEPTACLES:$ - 0
3920 Amp Specification grade Quad receptaclesEA4$ - 0
4020 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1$ - 0
41EQUIPMENT RACKS$ - 0
422 post, floor mounted 19" Equipment rackEA6$ - 0
43SAFETY EQUIPMENT:$ - 0
44Fire Extinguisher: Electrical ratedEA1$ - 0
45Eye Wash StationEA1$ - 0
46Smoke DetectorEA1$ - 0
50OTHER:$ - 0
51Service Manual detailing location of key shelter components$ - 0
52Shelter drawings$ - 0
53Solar Mounts$ - 0
54$ - 0
55Transportation to R5EA1
56Installation with CraneEA1
57
58Delivery Address: Klamath NF Yreka Service Center, 1030 S Main St, Yreka, CA 96097. Offload required by vendor.
59$ - 0
60GRAND TOTAL$ - 0

R6 Red Oak 8x10 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R9 Gauley RD, Monongahela NF
Point of Contact (Local SAT):Brian Post
Phone (Local SAT):
Street Address:731 Yokum St
City, State:Elkins, WV
Zip:26250
Additional Information needed for request.
Project Point of Contact (name and phone):Brian Post
Additional Technical Contact (name and phone), if applicable:Cliff Guntly
WR # or Incident Number:2018992
Override/Job Code:2505/NFVW0518
Q-CODEQ2741618
UIA1107092127416
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#2018992
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton (530) 226-2779
Comments:Red Oak communications site Latitude N38 21' 12", Longitude W80 26' 26", Elevation 3691 ft. Door location: South, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 8' wide x 10' long x 9' highEA1$ - 0
3Interior Dimensions: 6'8" wide x 8'8" long x 9' high ceiling$ - 0
4SPECIAL FEATURES:$ - 0
5Bullet proof walls$ - 0
62 hour fire rating$ - 0
7Insulation R20 average throughout.$ - 0
8ROOF AND FLOOR$ - 0
9Roof coating: EPDM$ - 0
10Flooring: Standard tile$ - 0
11INTERIOR WALLS AND CEILING:$ - 0
12FRP (Fiber-Reinforced Plastic) covered plywood$ - 0
13DOOR: Direction South$ - 0
143070 Door, 18 Gauge GalvanizedEA1$ - 0
153070 Frame, 16 Gauge GalvanizedEA1$ - 0
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1$ - 0
17Lock: 626-Entry w/deadbolt functionEA1$ - 0
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1$ - 0
18Latch Protector (SS)EA1$ - 0
19Door PullEA2$ - 0
20Magnetic Weather StrippingEA1$ - 0
21Drip Cap: 76" x 2-1/2"EA1$ - 0
22SS Hinges: Ball BearingEA3$ - 0
23Threshold: Bumper 36"EA1$ - 0
24Threshold: Saddle 36"EA1$ - 0
23CABLE TRAY:$ - 0
2416 linear feet of 12" wide steel cable trays$ - 0
25CABLE ENTRY:$ - 0
268 port cable entry$ - 0
27ELECTRICAL:$ - 0
28120V/240V, 200A, single phase$ - 0
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1$ - 0
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1$ - 0
31GROUNDING:$ - 0
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1$ - 0
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1$ - 0
344 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.$ - 0
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1$ - 0
36INTERIOR LIGHTS:$ - 0
3748" 40 wattEA4$ - 0
38RECEPTACLES:$ - 0
39Receptacle: DualEA8$ - 0
40Receptacle: GFIEA1$ - 0
41EQUIPMENT RACKS$ - 0
422 post, floor mounted 19" Equipment rackEA1$ - 0
43SAFETY EQUIPMENT:$ - 0
44Fire Extinguisher: Electrical ratedEA0$ - 0
45Eye Wash StationEA0$ - 0
46Smoke DetectorEA0$ - 0
47COMFORT/CONVENIENCE:$ - 0
48Exhaust Fan 600 cfm 12" x 12"EA0$ - 0
49Louver Motorized - 12" x 12"EA0$ - 0
50OTHER:$ - 0
51Service Manual detailing location of key shelter components$ - 0
52Shelter drawings$ - 0
53Solar Anchor Points$ - 0
54$ - 0
55Transportation to R9EA1$ - 0
56Installation with CraneEA1$ - 0
57
58Delivery Address: Monongahela NF Depot, 731 Yokum St, Elkins, WV 26250. Offload required by vendor.
59$ - 0
60GRAND TOTAL$ - 0

File details come from the government source that posted it.