BOM.XLSX
XLSX spreadsheet 31 KB Posted
- Attached to
- Communications Building, Transportation and Installation Federal contract opportunity
- Solicitation number
- 12760418Q0019
About this file
Bill of materials
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PWS.pdf | ||
| NEPADocumentsNFVW0518Shelters.pdf | ||
| GPATLMRFY18LifeCycle.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Summary
| Region | Ship to | Forest/District | SITE | POC | BOM Amount |
| R5 | Klamath NF | Salmon Scott RD | Eddie Gulch 10x18x8 Shelter | Matt Holmes | $0.00 |
| R9 | Monongahela NF | Gauley RD | Red Oak 8x10x8 Shelter | Brian Post | $0.00 |
TOTALS $0.00
R5 Eddy Gulch 10x18 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R5 Salmon Scott RD, Klamath NF | |
| Point of Contact (Local SAT): | Matt Holmes | |
| Phone (Local SAT): | ||
| Street Address: | 1030 South Main St | |
| City, State: | Yreka, CA | |
| Zip: | 96097 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Matt Holmes | |
| Additional Technical Contact (name and phone), if applicable: | Tony Martinez | |
| WR # or Incident Number: | 20182937 | |
| Override/Job Code: | 2505/NFVW0518 | |
| Q-CODE | Q4900518 | |
| UIA | 1107050549005 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#20182937 001 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton (530)226-2779 | |
| Comments: | Eddy Gulch communications site Latitude N41 14' 37", Longitude W123 06' 13", Elevation 6500ft. Door location: Southeast, Tower: N/A. |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 10' wide x 18' long x 8' high | EA | 1 | |||
| 3 | Size Nominal 8'8" Wide Interior x Nominal 16'8" Long x Nominal 8' high interior, one room concrete shelter. | $ - 0 | ||||
| 4 | SPECIAL FEATURES: | $ - 0 | ||||
| 5 | Bullet proof walls | $ - 0 | ||||
| 6 | 2 hour fire rating | $ - 0 | ||||
| 7 | Insulation R20 average throughout. | $ - 0 | ||||
| 8 | ROOF AND FLOOR | $ - 0 | ||||
| 9 | Roof coating: EPDM | $ - 0 | ||||
| 10 | Flooring: Standard tile | $ - 0 | ||||
| 11 | INTERIOR WALLS AND CEILING: | $ - 0 | ||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | $ - 0 | ||||
| 13 | DOOR: Direction East | $ - 0 | ||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | $ - 0 | ||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | $ - 0 | ||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | $ - 0 | ||
| 18 | Latch Protector (SS) | EA | 1 | $ - 0 | ||
| 19 | Door Pull | EA | 2 | $ - 0 | ||
| 20 | Magnetic Weather Stripping | EA | 1 | $ - 0 | ||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | $ - 0 | ||
| 22 | SS Hinges: Ball Bearing | EA | 3 | $ - 0 | ||
| 23 | Threshold: Bumper 36" | EA | 1 | $ - 0 | ||
| 24 | Threshold: Saddle 36" | EA | 1 | $ - 0 | ||
| 23 | CABLE TRAY: | $ - 0 | ||||
| 24 | 29 linear feet of 12" wide steel cable trays | $ - 0 | ||||
| 25 | CABLE ENTRY: | $ - 0 | ||||
| 26 | 8 port cable entry | $ - 0 | ||||
| 27 | ELECTRICAL: | $ - 0 | ||||
| 28 | 120V/240V, 200A, single phase | $ - 0 | ||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | $ - 0 | ||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | $ - 0 | ||
| 31 | GROUNDING: | $ - 0 | ||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | $ - 0 | ||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | $ - 0 | ||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | $ - 0 | ||
| 36 | INTERIOR LIGHTS: | $ - 0 | ||||
| 37 | 48" 40 watt | EA | 2 | $ - 0 | ||
| 38 | RECEPTACLES: | $ - 0 | ||||
| 39 | 20 Amp Specification grade Quad receptacles | EA | 4 | $ - 0 | ||
| 40 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | $ - 0 | ||
| 41 | EQUIPMENT RACKS | $ - 0 | ||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 6 | $ - 0 | ||
| 43 | SAFETY EQUIPMENT: | $ - 0 | ||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | $ - 0 | ||
| 45 | Eye Wash Station | EA | 1 | $ - 0 | ||
| 46 | Smoke Detector | EA | 1 | $ - 0 | ||
| 50 | OTHER: | $ - 0 | ||||
| 51 | Service Manual detailing location of key shelter components | $ - 0 | ||||
| 52 | Shelter drawings | $ - 0 | ||||
| 53 | Solar Mounts | $ - 0 | ||||
| 54 | $ - 0 | |||||
| 55 | Transportation to R5 | EA | 1 | |||
| 56 | Installation with Crane | EA | 1 | |||
| 57 | ||||||
| 58 | Delivery Address: Klamath NF Yreka Service Center, 1030 S Main St, Yreka, CA 96097. Offload required by vendor. | |||||
| 59 | $ - 0 | |||||
| 60 | GRAND TOTAL | $ - 0 |
R6 Red Oak 8x10 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R9 Gauley RD, Monongahela NF | |
| Point of Contact (Local SAT): | Brian Post | |
| Phone (Local SAT): | ||
| Street Address: | 731 Yokum St | |
| City, State: | Elkins, WV | |
| Zip: | 26250 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Brian Post | |
| Additional Technical Contact (name and phone), if applicable: | Cliff Guntly | |
| WR # or Incident Number: | 2018992 | |
| Override/Job Code: | 2505/NFVW0518 | |
| Q-CODE | Q2741618 | |
| UIA | 1107092127416 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#2018992 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton (530) 226-2779 | |
| Comments: | Red Oak communications site Latitude N38 21' 12", Longitude W80 26' 26", Elevation 3691 ft. Door location: South, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 8' wide x 10' long x 9' high | EA | 1 | $ - 0 | ||
| 3 | Interior Dimensions: 6'8" wide x 8'8" long x 9' high ceiling | $ - 0 | ||||
| 4 | SPECIAL FEATURES: | $ - 0 | ||||
| 5 | Bullet proof walls | $ - 0 | ||||
| 6 | 2 hour fire rating | $ - 0 | ||||
| 7 | Insulation R20 average throughout. | $ - 0 | ||||
| 8 | ROOF AND FLOOR | $ - 0 | ||||
| 9 | Roof coating: EPDM | $ - 0 | ||||
| 10 | Flooring: Standard tile | $ - 0 | ||||
| 11 | INTERIOR WALLS AND CEILING: | $ - 0 | ||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | $ - 0 | ||||
| 13 | DOOR: Direction South | $ - 0 | ||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | $ - 0 | ||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | $ - 0 | ||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | $ - 0 | ||
| 18 | Latch Protector (SS) | EA | 1 | $ - 0 | ||
| 19 | Door Pull | EA | 2 | $ - 0 | ||
| 20 | Magnetic Weather Stripping | EA | 1 | $ - 0 | ||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | $ - 0 | ||
| 22 | SS Hinges: Ball Bearing | EA | 3 | $ - 0 | ||
| 23 | Threshold: Bumper 36" | EA | 1 | $ - 0 | ||
| 24 | Threshold: Saddle 36" | EA | 1 | $ - 0 | ||
| 23 | CABLE TRAY: | $ - 0 | ||||
| 24 | 16 linear feet of 12" wide steel cable trays | $ - 0 | ||||
| 25 | CABLE ENTRY: | $ - 0 | ||||
| 26 | 8 port cable entry | $ - 0 | ||||
| 27 | ELECTRICAL: | $ - 0 | ||||
| 28 | 120V/240V, 200A, single phase | $ - 0 | ||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | $ - 0 | ||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | $ - 0 | ||
| 31 | GROUNDING: | $ - 0 | ||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | $ - 0 | ||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | $ - 0 | ||
| 34 | 4 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | $ - 0 | ||||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | $ - 0 | ||
| 36 | INTERIOR LIGHTS: | $ - 0 | ||||
| 37 | 48" 40 watt | EA | 4 | $ - 0 | ||
| 38 | RECEPTACLES: | $ - 0 | ||||
| 39 | Receptacle: Dual | EA | 8 | $ - 0 | ||
| 40 | Receptacle: GFI | EA | 1 | $ - 0 | ||
| 41 | EQUIPMENT RACKS | $ - 0 | ||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 1 | $ - 0 | ||
| 43 | SAFETY EQUIPMENT: | $ - 0 | ||||
| 44 | Fire Extinguisher: Electrical rated | EA | 0 | $ - 0 | ||
| 45 | Eye Wash Station | EA | 0 | $ - 0 | ||
| 46 | Smoke Detector | EA | 0 | $ - 0 | ||
| 47 | COMFORT/CONVENIENCE: | $ - 0 | ||||
| 48 | Exhaust Fan 600 cfm 12" x 12" | EA | 0 | $ - 0 | ||
| 49 | Louver Motorized - 12" x 12" | EA | 0 | $ - 0 | ||
| 50 | OTHER: | $ - 0 | ||||
| 51 | Service Manual detailing location of key shelter components | $ - 0 | ||||
| 52 | Shelter drawings | $ - 0 | ||||
| 53 | Solar Anchor Points | $ - 0 | ||||
| 54 | $ - 0 | |||||
| 55 | Transportation to R9 | EA | 1 | $ - 0 | ||
| 56 | Installation with Crane | EA | 1 | $ - 0 | ||
| 57 | ||||||
| 58 | Delivery Address: Monongahela NF Depot, 731 Yokum St, Elkins, WV 26250. Offload required by vendor. | |||||
| 59 | $ - 0 | |||||
| 60 | GRAND TOTAL | $ - 0 |
File details come from the government source that posted it.