Drawings.pdf
PDF 5 MB Posted
- Attached to
- Repairs to Water Treatment Facility
- Solicitation number
- 12639520R0014
About this file
This document provides details for a federal contract opportunity to modify a water treatment facility. The U.S. Department of Agriculture Animal and Plant Health Inspection Service intends to issue a request for proposals to modify an existing alum chemical feed system, add a second package water treatment unit, modify existing controls and panels, install additional piping and instrumentation, and modify the raw water pump control panel at the Moore Air Base in Edinburg, Texas. The project cost is estimated between $500,000 to $1 million. The NAICS code is 237110 with a small business size standard of $39.5 million. The solicitation and all documents will be available on beta.sam.gov on or after July 24, 2020. Interested parties should monitor this site for the solicitation and any amendments. Questions should be directed to the contracting officer by email.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0002.pdf | ||
| Amendment 0001.pdf | ||
| 12639520R0014.pdf | ||
| DOL wage rates.pdf | ||
| Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
LOCATION
M
O
O
R
E
F
I E
L D
R
N
M
O
O
R
E
F
I E
C
O
U
N
T
Y
A
C
O
U
N
Y
WATER TREATMENT
PLANT
MOORE AIR BASE
COVER SHEET AND DRAWING INDEX
GG01 1
NONE
AM ROMERO
DL WILGES
APRIL 24, 2019
DK MATHIAS
LJ LEISCHNER
1 REISSUE BID PACKAGE AMR DKM LJL 6-19-20
NORTH
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
USDA CONTRACT NO: AG-6395-C-16-0119
PROJECT LOCATION PLAN
PROJECT LOCATION MAP
D
A
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
102678
LARRY J. LEISCHNER
06/19/20
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
GENERAL LEGEND
GG02 1
D
A
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
OPENING OR DEPRESSION IN SLAB OR WALL
OPENING WITH GRATING COVER (PLAN)
ROUGHENED CONSTRUCTION JOINT
CONSTRUCTION JOINT (KEYWAY)
CONSTRUCTION JOINT (KEYWAY) WITH WATERSTOP
MASONRY CONTROL JOINT (IN PLAN)
MASONRY EXPANSION JOINT (IN PLAN)
ROUGHENED CONSTRUCTION JOINT WITH WATERSTOP
OPENING WITH CHECKERED PLATE COVER (PLAN)
DRAWING NUMBER(S)
ON WHICH VIEW IS
CALLED OUT
VIEW IDENTIFICATION
NUMBER
DESIGNATES LOCATION
OF DETAIL
DESIGNATES DIRECTION
FROM WHICH PLAN OR
ELEVATION IS VIEWED
DESIGNATES CUTTING
PLANE OF SECTION
DIMENSIONS AND/OR ELEVATIONS MARKED THUS (+/-) MUST BE
VERIFIED IN THE FIELD BY THE CONTRACTOR.
DIMENSIONS AND/OR ELEVATIONS MARKED THUS ( ) ARE
ASSUMED AND SHALL BE VERIFIED OR MODIFIED AS REQUIRED
BY THE CONTRACTOR TO SUIT EQUIPMENT FURNISHED. FINAL
DIMENSIONS ARE SUBJECT TO THE REVIEW OF THE ENGINEER.
DIMENSIONS AND/OR ELEVATIONS MARKED THUS ( ) ARE APPROXIMATE.
OBTAIN FINAL DIMENSIONS FOR CONSTRUCTION FROM THE ENGINEER.
1. ALL DIMENSIONS OF EXISTING CONSTRUCTION ARE APPROXIMATE. CONTRACTOR SHALL SURVEY AND
MAKE ALL NECESSARY FIELD MEASUREMENTS OF EXISTING STRUCTURES AND EQUIPMENT TO VERIFY
DIMENSIONS SHOWN ON DRAWINGS, AND TO PROVIDE DIMENSIONS NOT SHOWN, PRIOR TO
FABRICATION. ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED SHALL BE REPORTED IN
WRITING TO THE DESIGN PROFESSIONAL AND OWNER'S REPRESENTATIVE WITHIN TWENTY-FOUR (24)
HOURS. COSTS FOR MODIFICATIONS OF NEW CONSTRUCTION, DUE TO LACK OF CONFIRMATION OF
DIMENSIONS BY FIELD MEASUREMENTS, SHALL BE BORNE BY CONTRACTOR.
2. CONTRACTOR SHALL REVIEW CONTRACT DOCUMENTS TO DETERMINE THE EXACT LOCATION OF ALL
WORK AND VERIFY SPATIAL RELATIONSHIPS OF ALL WORK. ANY QUESTION CONCERNING LOCATION OR
SPATIAL RELATIONSHIPS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE. SPECIFIC
LOCATIONS FOR EQUIPMENT, PIPELINES, DUCTWORK AND OTHER SUCH ITEMS OF WORK, WHERE NOT
DIMENSIONED ON DRAWINGS, SHALL BE DETERMINED IN CONSULTATION WITH OWNER'S
REPRESENTATIVE AND DESIGN PROFESSIONAL BY CONTRACTOR. CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PROPER FITTING OF THE WORK IN PLACE.
NOTES:
1. ALL ELBOWS ARE SHORT RADIUS UNLESS NOTED OTHERWISE.
2. ALL REDUCERS ARE CONCENTRIC UNLESS NOTED OTHERWISE.
NORMALLY
OPEN
NORMALLY
CLOSED
SWING CHECK
HOSE BIBB
W/ HYDRANT
SLEEVE TYPE
MECHANICAL COUPLING
AFF
ALUM
ATS
CL
CL
CLR
CMU
CTRS
DIA
ED
EEWS
EF
EL
EW
EXST
FD
FT
HB
HCID
HM
HSP-#
HYD
IE
IEX
LAS
LVR
MCC
pH
PL
PW
RWP-#
SD
SK
SPAC
T & B
TP-#
TP-##
(TYP)
UH
VT
VTR
WH
WTR
- ABOVE FINISH FLOOR
- ALUMINUM SULFATE
- AUTOMATIC TRANSFER SWITCH
- CENTERLINE
- CHLORINE GAS
- CLEAR / CLEARANCE
- CONCRETE MASONRY UNIT
- CENTERS
- DIAMETER
- EQUIPMENT DRAIN
- EMERGENCY EYE WASH STATION
- EXHAUST FAN
- ELEVATION
- EACH WAY
- EXISTING
- FLOOR DRAIN
- FEET / FOOT
- HOSE BIBB
- HIDALGO COUNTY IRRIGATION DISTRICT
- HOLLOW METAL
- HIGH SERVICE PUMP
- HYDRANT
- INVERT ELEVATION
- ON EXCHANGE
- LIQUID AMMONIUM SULFATE
- LOUVER
- MOTOR CONTROL CENTER
- POTENTIAL HYDROGEN
- PLATE / PLASTIC LAMINATE
- POTABLE WATER
- RAW WATER PUMP
- SANITARY DRAIN
- SINK
- SUPERVISORY PANEL
- TOP & BOTTOM
- TRANSFER PUMP (WATER PLANT DISCHARGE, ON SKID)
- TIE POINT NUMBER (SEE GG05)
- TYPICAL
- UNIT HEATER
- VENT
- VENT THRU ROOF
- WATER HEATER
- WATER
VIEW MARKERS GENERAL SYMBOLS ABBREVIATIONS GENERAL NOTES
GENERAL MATERIALS LEGEND
MECHANICAL
SECTION
ELEVATION
DETAIL
DIMENSIONS AND SCALE
A-SF1
B-SF1
C-SF1
FIELD MEASURMENT NOTES
NUMERIC SCALE VALUES (1/4"=1'-0", ETC) APPLY ONLY AT FULL SIZE.
DIMENSIONS ARE GENERALLY TO SCALE, BUT SHOULD NOT BE SCALED.
USE DIMENSIONS SHOWN. NTS (NOT TO SCALE) IS SHOWN ONLY WHERE
DIMENSION IS OBVIOUSLY OUT OF SCALE.
ALL SYMBOLS AND ABBREVIATIONS SHOWN ON THIS LEGEND
MAY NOT APPEAR ON THIS SET OF DRAWINGS.
1.
FLEX CONNECTION
CONCENTRIC REDUCER
ECCENTRIC REDUCER
EQUIP DRAIN
FLOOR DRAIN
EXPANSION JOINT
90° BEND PIPE TURN DOWN
90° BEND PIPE TURN UP
FLANGED JOINT
MECHANICAL JOINT
EXPANSION JOINT
CENTRIFUGAL PUMP
EARTH
ROCK
CRUSHED ROCK
SAND, CMU, PLASTER
GRANULAR FILL
CONCRETE
STEEL (IN SECTION)
NON-FERROUS METAL
BRICK IN SECTION
ROUGH WOOD (IN SECTION)
PLYWOOD
RIGID INSULATION
BATT INSULATION
GLASS (ELEVATION)
SQUARE
DIAMETER OR ROUND
CENTERLINE
PROPERTY LINE
GUARDRAIL/HANDRAIL
ELEVATION DESIGNATION
EXISTING OBJECT LINE
EXISTING OBJECT TO BE REMOVED OR RELOCATED
OUTLINE OF NEW OR RELOCATED OBJECT
OUTLINE OF FUTURE OBJECT
CENTER LINE
HIDDEN LINE
SURFACE BREAK LINE
MATERIAL BREAK LINE
MATCH LINE
EL 100'-0"
WELDED WIRE FABRIC
REINFORCING BARS IN CONCRETE
GATE
BALL
BUTTERFLY
CONTRACT IDENTIFICATION:
NUMBER AT LEFT INDICATES CONTRACT FURNISHING,
NUMBER AT RIGHT INDICATES CONTRACT INSTALLING.
COLUMN IDENTIFICATION:
SUBSTITUTE LETTER OR NUMBER FOR ASTERISK
REVISION IDENTIFICATION SYMBOL:
THE NUMBER IN THE TRIANGLE INDICATES THE REVISION
NUMBER IDENTIFIED. THE LETTER "A" IMMEDIATELY TO THE
RIGHT OF THE TRIANGLE INDICATES THE REVISION IS PART OF
A CONTRACT ADDENDUM. WHEN REVISIONS INVOLVE LESS THAN
ENTIRE DRAWING, PRINCIPAL ASPECTS OF REVISIONS ARE
"CLOUDED".
SF1,SF2
A-SF1
B-SF1
C-SF1
SF1,SF2
SF1,SF2
102678
LARRY J. LEISCHNER
06/19/20
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AM ROMERO
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
DK MATHIAS
AutoCAD SHX Text
LJ LIESCHNER
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
AMR
AutoCAD SHX Text
DKM
AutoCAD SHX Text
LJL
AutoCAD SHX Text 6-19-20
AutoCAD SHX Text
OR CL
AutoCAD SHX Text
OR PL
AutoCAD SHX Text
SPAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ED
AutoCAD SHX Text
FD
AutoCAD SHX Text
HB
AutoCAD SHX Text A
AutoCAD SHX Text
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
ELECTRICAL LEGEND
GG03 1
GROUND CONDUCTOR
GROUNDING
GROUND ROD
GROUND
GROUNDING PIGTAIL
EXPOSED
FLUSH GROUND PLATE
LIGHTNING PROTECTION CONDUCTOR
LIGHTNING PROTECTION AIR TERMINAL
GROUND CONDUCTOR CONNECTION
GROUNDING CONNECTION TO STRUCTURE
UNDERGROUND DIRECT BURIAL
CONDUIT TURN-DOWN
JUNCTION BOX
CONDUIT TURN-UP
ELECTRICAL DEVICE
MOUNTING HEIGHT
INDICATES CABLE NUMBER
BUS
POWER CIRCUIT
CT & VT CIRCUIT
CONTROL CIRCUIT
COMMUNICATION
ELECTRICAL ENCLOSURE
PANELBOARD
TRANSFER SWITCH (AUTOMATIC OR
MANUAL)
THERMOSTAT
SURFACE RACEWAY (WIREMOLD)
LIGHTNING PROTECTION SPHERE
THROUGH ROOF TERMINAL
GENERAL NOTESONE-LINE AND RISER
RACEWAY AND LINE TYPES
CONDUIT:
DUCTBANK
EMBEDDED
CONDUIT STUB WITH CAP
MINIATURE CIRCUIT BREAKER
BATTERY
SOLID GROUNDED WYE
DELTA
GROUND
MULTIFUNCTION RELAY OR METER (* NOTE 5)
OPEN DELTA
IMPEDANCE GROUNDED WYE
VOLTAGE TRANSFORMER
CURRENT TRANSFORMER,
ZERO SEQUENCE
PLAN VIEW
TRANSFORMER
FUSED DISCONNECT SWITCH
HORSEPOWER RATED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
COMBINATION DISCONNECT WITH STARTER
MOTOR
LOCAL CONTROL PANEL
GENERATOR
MANHOLE
HANDHOLE
FLOOR RECEPTACLE
DUPLEX RECEPTACLE
FOURPLEX RECEPTACLE
SINGLE RECEPTACLE
PANELBOARD, 208Y/120V OR 120/240V
TRANSFER SWITCH ( MANUAL)
SPECIAL PURPOSE RCPT OR CONNECTION, 480V
SPECIAL PURPOSE RCPT OR CONNECTION, 240V
PANELBOARD, 480Y/277V OR 480V
POWER SERVICE POLE
COMBINATION TELE-POWER SERVICE POLE
SERVICE ENTRANCE METER
LOW VOLTAGE CIRCUIT BREAKER,
DRAWOUT:
E.O. = ELECTRICALLY OPERATED
G = GROUND
I = INSTANTANEOUS
IA = INSTANTANEOUS AMPS
LT = LONG TIME
M.O. = MANUALLY OPERATED
ST = SHORT TIME
S = SENSOR RATING
MOLDED CASE CIRCUIT BREAKER
MEDIUM VOLTAGE CIRCUIT
BREAKER, DRAWOUT
FUSED CUT-OUT SWITCH
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
COMBINATION CIRCUIT BREAKER WITH STARTER:
FVNR = FULL VOLTAGE NON-REVERSING
FVR = FULL VOLTAGE REVERSING
2S = TWO SPEED
1W = ONE WINDING
2W = TWO WINDING
C = CONTACTOR
SFT = SOFT START
MEDIUM VOLTAGE MOTOR STARTER
CONVERTER OR VFD
~ = AC
- = DC
MOTOR
GENERATOR
LOCAL CONTROL:
CP = CONTROL PANEL
HTR = HEATER
SKD = SKID MOUNTED LOAD
VFD = VARIABLE FREQUENCY DRIVE
SURGE ARRESTOR
FUSE
CURRENT TRANSFORMER
INDICATES POLARITY
RECEPTACLE OPTIONS, IF REQ'D:
GFI = GROUND FAULT INTERRUPTING
IG = ISOLATED GROUND
S = SWITCH AND OUTLET
WP = WEATHERPROOF
XP = EXPLOSIONPROOF
FINISHED FLOOR
1. ALL SYMBOLS AND ABBREVIATIONS SHOWN ON THIS LEGEND
MAY NOT APPEAR ON THIS SET OF DRAWINGS.
2. FOR GENERAL LEGEND AND ABBREVIATIONS, SEE GG02.
3. X ON FIXTURE SYMBOL DENOTES FIXTURE TYPE
DESIGNATION. SEE FIXTURE SCHEDULE.
4. USE DIRECTIONAL ARROW ON EXIT SIGNS AS REQUIRED.
5. IEEE STANDARD C37.2-1991, ELECTRICAL POWER SYSTEM
DEVICE FUNCTION NUMBERS.
116530
ERNEST E. LEAF
06-19-20
AutoCAD SHX Text
NONE
AutoCAD SHX Text
MJ HILL
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
EE LEAF
AutoCAD SHX Text
EE LEAF
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
MJH
AutoCAD SHX Text
EEL
AutoCAD SHX Text
EEL
AutoCAD SHX Text 6-19-20
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 6'-6"
AutoCAD SHX Text T
AutoCAD SHX Text J
AutoCAD SHX Text
XFR
AutoCAD SHX Text
GEN
AutoCAD SHX Text M
AutoCAD SHX Text
MH
AutoCAD SHX Text
HH
AutoCAD SHX Text
KVA,CLG
AutoCAD SHX Text
HV-LV
AutoCAD SHX Text Z
AutoCAD SHX Text
POWER TRANSFORMER
AutoCAD SHX Text
AMP
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AF
AutoCAD SHX Text
AMP
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
AMP
AutoCAD SHX Text
AMP
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
AutoCAD SHX Text
AF
AutoCAD SHX Text
AT
AutoCAD SHX Text
AMP
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HP
AutoCAD SHX Text
GEN
AutoCAD SHX Text
KW
AutoCAD SHX Text
KVA
AutoCAD SHX Text
PF
AutoCAD SHX Text Z
AutoCAD SHX Text
AutoCAD SHX Text
KV
AutoCAD SHX Text
MCOV
AutoCAD SHX Text
AMP
AutoCAD SHX Text
AMP
AutoCAD SHX Text
AutoCAD SHX Text
(QTY)
AutoCAD SHX Text
PRI:SEC
AutoCAD SHX Text
ACCUR
AutoCAD SHX Text
(QTY)
AutoCAD SHX Text
PRI/SEC
AutoCAD SHX Text
ACCUR
AutoCAD SHX Text
PRI/SEC
AutoCAD SHX Text
ACCUR
AutoCAD SHX Text T
AutoCAD SHX Text
HP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
T O
T A
L
C
H L O
R I N
E
FM
GROUND STORAGE TANK
T U
R B
I D
I T
Y
FM
WATER BOY UNIT 1
WATER BOY UNIT 2
FM
TRANSFER PUMPS
TRANSFER PUMPS
AERATED 5 MILLION
GALLON RAW WATER
RESERVOIR
HCID #6 IRRIGATION
CANAL
NOTES:
1. ITEMS SHOWN GREY ARE EXISTING; ITEMS SHOWN IN
BLACK ARE NEW, BY CONTRACTOR.
2. VALVES ARE NOT SHOWN.
3. DISTRIBUTION SYSTEM LOOPS ARE SHOWN FOR
REFERENCE ONLY. VALVES, ETC. ARE OMITTED FOR
CLARITY.
LEGEND:
SAMPLE
CHEMICAL APPLICATION
FLOW METER
RAW WATER PUMPS
HIGH SERVICE PUMPS
ELEVATED WATER
STORAGE TANK
PROCESS SCHEMATIC
GG04 1
BOUNDARY OF WATER
TREATMENT PLANT BUILDING
DISTRIBUTION LOOPS
102678
LARRY J. LEISCHNER
PI01-TP03
PI01-TP02
PI01-TP01
PI01-TP04
PI01-TP05
06/19/20
AutoCAD SHX Text
PH
AutoCAD SHX Text
CHLORINE DIOXIDE
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
LAS
AutoCAD SHX Text
CHLORINE
AutoCAD SHX Text
TURBIDITY
AutoCAD SHX Text
PH
AutoCAD SHX Text
FM
AutoCAD SHX Text
CHLORINE DIOXIDE
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AM ROMERO
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
DK MATHIAS
AutoCAD SHX Text
LJ LIESCHNER
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
AMR
AutoCAD SHX Text
DKM
AutoCAD SHX Text
LJL
AutoCAD SHX Text 6-19-20
TURBIDITY
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
PIPING AND INSTRUMENTATION
LEGEND
GG05 1
102678
LARRY J. LEISCHNER
06/19/20
AutoCAD SHX Text
AM ROMERO
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
DK MATHIAS
AutoCAD SHX Text
LJ LIESCHNER
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
AMR
AutoCAD SHX Text
DKM
AutoCAD SHX Text
LJL
AutoCAD SHX Text 6-19-20
AutoCAD SHX Text
MODIFIER
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
DOWN OR
AutoCAD SHX Text
CLOSED, CONFIRM
AutoCAD SHX Text
AMBER, AUTO,
AutoCAD SHX Text
BLUE
AutoCAD SHX Text
ALARM
AutoCAD SHX Text
PASSIVE FUNCTION
AutoCAD SHX Text
READOUT OR
AutoCAD SHX Text
USER'S CHOICE
AutoCAD SHX Text
MEASURED OR
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CONDUCTIVITY
AutoCAD SHX Text
BURNER FLAME
AutoCAD SHX Text
(ELECTRICAL)
AutoCAD SHX Text A
AutoCAD SHX Text
ANALYSIS
AutoCAD SHX Text
INITIATING VARIABLE
AutoCAD SHX Text
FIRST LETTER
AutoCAD SHX Text
MODIFIER
AutoCAD SHX Text
SUCCEEDING LETTERS
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text
BUTTON
AutoCAD SHX Text
GREEN, GROUND
AutoCAD SHX Text
FLOOR, FORWARD
AutoCAD SHX Text
HIGH, HAND
AutoCAD SHX Text
OFF, FAULT
AutoCAD SHX Text
DCS
AutoCAD SHX Text
OPEN, ON (RUN),
AutoCAD SHX Text
LOW, LEAD
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
UP
AutoCAD SHX Text
RED, REMOTE
AutoCAD SHX Text
START
AutoCAD SHX Text
WHITE
AutoCAD SHX Text
VALVE, REVERSE
AutoCAD SHX Text
GLASS, VIEWING
AutoCAD SHX Text
INDICATE
AutoCAD SHX Text
SENSOR
AutoCAD SHX Text
LIGHT (PILOT)
AutoCAD SHX Text
(RESTRICTION)
AutoCAD SHX Text
ORIFICE
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
FLOW RATE
AutoCAD SHX Text
VOLTAGE (EMF)
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text
(DIMENSIONAL)
AutoCAD SHX Text
INITIATED)
AutoCAD SHX Text
CURRENT
AutoCAD SHX Text G
AutoCAD SHX Text
GAUGING
AutoCAD SHX Text
HAND (MANUALLY
AutoCAD SHX Text
SPECIFIC GRAVITY
AutoCAD SHX Text
SCAN
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text
TIME OR TIME-
AutoCAD SHX Text
MOISTURE OR
AutoCAD SHX Text
SCHEDULE
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
POWER
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text
PRESSURE OR
AutoCAD SHX Text
USER'S CHOICE
AutoCAD SHX Text
PLC/DCS INPUT
AutoCAD SHX Text
HUMIDITY
AutoCAD SHX Text M
AutoCAD SHX Text
(ELECTRICAL)
AutoCAD SHX Text
RATIO (FRACTION)
AutoCAD SHX Text
RECORD OR PRINT
AutoCAD SHX Text
MULTIFUNCTION
AutoCAD SHX Text
WELL
AutoCAD SHX Text
TOTALIZE
AutoCAD SHX Text
SAFETY
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text
RADIATION
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
VACUUM
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text T
AutoCAD SHX Text
MULTIVARIABLE
AutoCAD SHX Text
TEMPERATURE
AutoCAD SHX Text
FREQUENCY
AutoCAD SHX Text
SPEED OR
AutoCAD SHX Text W
AutoCAD SHX Text Y
AutoCAD SHX Text X
AutoCAD SHX Text
EVENT, STATE, OR
AutoCAD SHX Text Z
AutoCAD SHX Text
POSITION
AutoCAD SHX Text
PLC/DCS OUTPUT
AutoCAD SHX Text
WEIGHT OR FORCE
AutoCAD SHX Text
VISCOSITY/VIBRATION
AutoCAD SHX Text V
AutoCAD SHX Text
INTEGRATE OR
AutoCAD SHX Text
REGULATING
AutoCAD SHX Text P
AutoCAD SHX Text
CONNECTION)
AutoCAD SHX Text
POINT (TEST
AutoCAD SHX Text
RELAY, COMPUTE
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
ELEMENT
AutoCAD SHX Text
FINAL CONTROL
AutoCAD SHX Text
OR UNCLASSIFIED
AutoCAD SHX Text
DRIVE, ACTUATOR
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
TRANSMIT
AutoCAD SHX Text
MULTIFUNCTION
AutoCAD SHX Text
LOUVER
AutoCAD SHX Text
VALVE, DAMPER,
AutoCAD SHX Text
STATION
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text
DIFFERENTIAL
AutoCAD SHX Text
DENSITY (MASS) OR
AutoCAD SHX Text D
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text
FOR GENERAL LEGEND AND ABBREVIATIONS, SEE GG02.
AutoCAD SHX Text ALL SYMBOLS AND ABBREVIATIONS SHOWN ON THIS LEGEND MAY NOT APPEAR ON THIS SET OF DRAWINGS.
AutoCAD SHX Text
FUNCTION IDENTIFICATION
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
READY
AutoCAD SHX Text
STOP
AutoCAD SHX Text
DEVICE
AutoCAD SHX Text
AVAILABLE
AutoCAD SHX Text
OVERLOAD
AutoCAD SHX Text
(PRIMARY ELEMENT)
AutoCAD SHX Text
PLC
AutoCAD SHX Text
DCS
AutoCAD SHX Text
DEVICE
AutoCAD SHX Text
INSTRUMENT TAG IDENTIFICATION
AutoCAD SHX Text
CONTROL PANEL MOUNTED (REAR)
AutoCAD SHX Text
COMPUTER FUNCTION
AutoCAD SHX Text
AUXILIARY PANEL MOUNTED (FRONT)
AutoCAD SHX Text
CONTROL PANEL MOUNTED (FRONT)
AutoCAD SHX Text
FIELD MOUNTED
AutoCAD SHX Text = ANALOG INPUT = ANALOG OUTPUT = DISCRETE INPUT = DISCRETE OUTPUT = THERMOCOUPLE = RELAY OUTPUT = RESISTANCE TEMPERATURE DETECTOR
AutoCAD SHX Text
AI AO DI DO TC RO RTD
AutoCAD SHX Text
GGG
AutoCAD SHX Text = FUNCTION IDENTIFICATION LETTERS = CONTROL LOOP NUMBER = UNIQUE MODIFIER (OPTIONAL) = I/O TYPE:
AutoCAD SHX Text
CCCCC DDDD E GGG
AutoCAD SHX Text
INSTRUMENT TAG DESIGNATIONS
AutoCAD SHX Text
CCCCC
AutoCAD SHX Text
DDDDD
AutoCAD SHX Text
AMM CIO CI CO CL CO COMB COND DO H H NA NOX N O ORP PH SMOKE SO SI0 TRB
AutoCAD SHX Text
ANALYZER IDENTIFICATION
AutoCAD SHX Text
XXXXX CODE:
AutoCAD SHX Text
XXXXX
AutoCAD SHX Text
AE
AutoCAD SHX Text = AMMONIA = CHLORINE DIOXIDE = CHLORINE GAS = CARBON DIOXIDE = CHLORIDE = CARBON MONOXIDE = COMBUSTIBLE = CONDUCTIVITY = DISSOLVED OXYGEN = DISSOLVED HYDROGEN = GASEOUS HYDROGEN = SODIUM = NITROGEN OXIDES = NITROGEN = GASEOUS OXYGEN = OXIDATION REDUCTION POTENTIAL = POTENTIAL HYDROGEN = SMOKE DENSITY = SULFUR DIOXIDE = SILICA = TURBIDITY
AutoCAD SHX Text
PROCESS LINE (W/ FLOW ARROW)
AutoCAD SHX Text
LINES
AutoCAD SHX Text
EXISTING LINE OR FURNISHED WITH THE EQUIPMENT
AutoCAD SHX Text
SOFTWARE LINK
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text STREAM ARROW INDICATES FLOW ENTERING OR LEAVING DRAWING AND CONTINUED ON OTHER DRAWING.
AutoCAD SHX Text
PROCESS LINE EXITING DRAWING AND NOT CONTINUED ON ANOTHER DRAWING
AutoCAD SHX Text
TIE POINT DESIGNATORS
AutoCAD SHX Text TIE POINT INTO AN EXISTING SYSTEM YYYY = P&ID DRAWING NUMBER XX = TIE POINT NUMBER
AutoCAD SHX Text
-TP
AutoCAD SHX Text
YYYY
AutoCAD SHX Text
FLOW ELEMENTS
AutoCAD SHX Text
MAGNETIC FLOWMETER
AutoCAD SHX Text
FE
AutoCAD SHX Text M
AutoCAD SHX Text
XXX
AutoCAD SHX Text
W-YYYY
AutoCAD SHX Text
CONNECTION NUMBER
AutoCAD SHX Text
XX
AutoCAD SHX Text
HARDWIRED SIGNAL INPUT/OUTPUT
FIBER OPTIC SIGNAL
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
PIPING AND
INSTRUMENTATION DIAGRAM
WATER PLANT NO. 1
PI01 1
NOTES:
1. ITEMS SHOWN GREY ARE EXISTING. ITEMS SHOWN IN BLACK
ARE NEW, BY CONTRACTOR, UNLESS NOTED OTHERWISE.
2. DRAWING BASED ON ORIGINAL PROJECT AS-BUILT P&ID DATED
11-24-2010.
3. SEE P&ID PI02 FOR NEW WATER PLANT NO. 2 AND
MISCELLANEOUS NEW I/O.
4. NEW WATER PLANT NO. 1 INLET MAG METER PROVIDED BY
WATER PLANT SUPPLIER AND INSTALLED BY CONTRACTOR, PER
MANUFACTURER RECOMMENDATIONS, INCLUDING OPTIMIZING
AVAILABLE UNOBSTRUCTED STRAIGHT RUN.
5. REFER TO SPECIFICATION SECTION 40 96 15 FOR GENERAL
CONTROL SYSTEM OPERATIONAL DESCRIPTION.
6. REFER TO SPECIFICATION SECTION 46 07 13 FOR WATER PLANT
SPEC, INCLUDING CONTROL DESCRIPTION AND SUPPLIER
SCOPE. REFER TO SPECIFICATION 46 30 13 FOR CHEMICAL
SYSTEMS SPECS, INCLUDING CONTROL DESCRIPTIONS AND
SUPPLIER SCOPE.
7. NEW WATER PLANT NO. 1 EFFLUENT RATE CONTROL VALVE AND
FILTER TO WASTE VALVE PROVIDED BY WATER PLANT SUPPLIER
AND INSTALLED BY CONTRACTOR. PIPING PROVIDED AND
INSTALLED BY CONTRACTOR.
134005
DEVIN D. ERIKSON
06/19/20
8. OUTLET OF FILTER TO WASTE LINE SHALL BE A MINIMUM OF 4"
ABOVE TOP OF TANK WALL.
9. SEE SPECIFICATION SECTION 46 07 13 FOR REQUIREMENTS FOR
SURFACE WASH SYSTEM.
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
KQI
AutoCAD SHX Text
AutoCAD SHX Text
HS
AutoCAD SHX Text
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
RWP-2
AutoCAD SHX Text pH
AutoCAD SHX Text
TRB
AutoCAD SHX Text
RWP-3
AutoCAD SHX Text
SEE PI02
AutoCAD SHX Text
BACKWASH SUPPLY FROM
AutoCAD SHX Text
HSP PUMP DISCHARGE
AutoCAD SHX Text
4-PI02
AutoCAD SHX Text
VENDOR SUPPLIED EQUIPMENT REF SPEC SEC 46 07 13
AutoCAD SHX Text
PI01-TP01
AutoCAD SHX Text
PI01-TP02
AutoCAD SHX Text
SEE DWG PI02
AutoCAD SHX Text
PI01-TP04
AutoCAD SHX Text
INFLUENT RATE CONTROL VALVE
AutoCAD SHX Text M
AutoCAD SHX Text
FE
AutoCAD SHX Text
AutoCAD SHX Text
FIT
AutoCAD SHX Text
AutoCAD SHX Text
TO WATER PLANT NO. 1 CONTROLLER
AutoCAD SHX Text
CONNECTION TO WATER PLANT (TYP)
AutoCAD SHX Text
120V NOTE 4
AutoCAD SHX Text
EFFLUENT RATE CONTROL VALVE
AutoCAD SHX Text
OPERATOR SAMPLE
AutoCAD SHX Text
TURBIDITY
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
TRB
AutoCAD SHX Text L S A
AutoCAD SHX Text
CONTINUED ON DRAWING PI02
AutoCAD SHX Text
TO GROUND STORAGE
AutoCAD SHX Text
5-PI02
AutoCAD SHX Text
LT
AutoCAD SHX Text
AutoCAD SHX Text
FILTER TO WASTE VALVE
AutoCAD SHX Text
PI01-TP05
AutoCAD SHX Text
TO WATER PLANT NO. 2
AutoCAD SHX Text
INFLUENT HEADER
AutoCAD SHX Text
1-PI02
AutoCAD SHX Text
TO WATER PLANT NO. 2
AutoCAD SHX Text
BACKWASH VALVE
AutoCAD SHX Text
2-PI02
AutoCAD SHX Text
FROM
AutoCAD SHX Text
WATER PLANT NO. 2
AutoCAD SHX Text
3-PI02
AutoCAD SHX Text
PI01-TP03
AutoCAD SHX Text
MULTIPLE CONNECTIONS TO WATER PLANT NO. 2 JUNCTION BOX
AutoCAD SHX Text ORIGINAL BOUNDARY OF WATER PLANT NO. 1 SUPPLIER SCOPE OF SUPPLY. CONDUIT, WIRING, AND PIPING BY CONTRACTOR AS SPECIFIED/REQUIRED.
AutoCAD SHX Text GST EFFLUENT pH
AutoCAD SHX Text
GST EFFLUENT TURBIDITY
AutoCAD SHX Text
RWP-1, RWP-2 AND RWP-3 START/STOP SIGNALS TO RAW WATER PUMP PANEL
AutoCAD SHX Text
RWP PANEL CONTROL HOA SWITCH
AutoCAD SHX Text
AAH
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
AAL
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
AAH
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text I
AutoCAD SHX Text
GST EFFLUENT TOTAL CL2
AutoCAD SHX Text
AAL
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
NOTE 7
AutoCAD SHX Text
CONNECTION TO WATER PLANT
AutoCAD SHX Text
EXST PIPE (TYP) NOTE 1
AutoCAD SHX Text
NEW PIPE (TYP) NOTE 1
AutoCAD SHX Text
COMBINED EFFLUENT TURBIDITY
AutoCAD SHX Text
AAH
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
TRB
AutoCAD SHX Text L A S
AutoCAD SHX Text
CHLORINE
AutoCAD SHX Text
LAS
AutoCAD SHX Text
NOTE 8
AutoCAD SHX Text
TO SURFACE WASH SYSTEM NOTE 9
AutoCAD SHX Text
ZM CARTER
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
SA WARREN
AutoCAD SHX Text
DD ERIKSON
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
ZMC
AutoCAD SHX Text
SAW
AutoCAD SHX Text
DDE
AutoCAD SHX Text 6-19-20
AutoCAD SHX Text
WATER PLANT NO. 1
AutoCAD SHX Text M
AutoCAD SHX Text
LCP DUPLEX RAW WATER PUMP CONTROL PANEL
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
PIPING AND
INSTRUMENTATION DIAGRAM
WATER PLANT NO. 2
PI02 1
NOTES:
1. ITEMS SHOWN GREY ARE EXISTING. ITEMS SHOWN IN BLACK
ARE NEW, BY CONTRACTOR, UNLESS NOTED OTHERWISE.
2. THIS P&ID INCLUDES SOME I/O THAT CONNECTS TO EQUIPMENT
SHOWN ON PI01 BUT SHOWN HERE FOR CLARITY.
3. SEE P&ID PI01 FOR ADDITIONAL I/O.
4. FOR CHEMICAL FEED SYSTEMS, SEE SPECIFICATION SECTION
46 30 13.
5. REPLACEMENT OF pH INSTRUMENT AIT-303 BY CONTRACTOR.
6. DISTRIBUTION SYSTEM LOOPS ARE SHOWN FOR REFERENCE
ONLY. VALVES, ETC. ARE OMITTED FOR CLARITY.
7. NEW WATER PLANT NO. 2 INLET MAG METER PROVIDED BY
WATER PLANT SUPPLIER AND INSTALLED BY CONTRACTOR, PER
MANUFACTURER RECOMMENDATIONS, INCLUDING OPTIMIZING
AVAILABLE UNOBSTRUCTED STRAIGHT RUN.
134005
DEVIN D. ERIKSON
06/19/20
8. UNDER OTHER PROJECT, AN EWST FIBER OPTIC I/O PANEL AND
CABLING BRINGS EWST LEVEL SIGNAL TO NEW FIBER OPTIC
PATCH PANEL NEAR MTU PANEL, INCLUDING MEDIA
CONVERSION FROM/TO HARDWIRED SIGNAL. COORDINATE WITH
OTHER PROJECT CONTRACTOR AS REQUIRED. HARDWARE BY
OTHERS. UNDER THIS PROJECT, PROGRAM PLC AND SCADA
DISPLAY FOR INDICATION OF THIS DATA POINT (MONITORING
ONLY, NO CONTROL LOGIC REQUIRED).
9. SEE SPECIFICATION SECTION 46 07 13 FOR REQUIREMENTS FOR
SURFACE WASH SYSTEM.
10. OUTLET OF FILTER TO WASTE LINE SHALL BE A MINIMUM OF 4"
ABOVE TOP OF TANK WALL.
AutoCAD SHX Text
INFLUENT TURBIDITY
AutoCAD SHX Text INFLUENT pH
AutoCAD SHX Text
HMI
AutoCAD SHX Text
PLC-MTU
AutoCAD SHX Text
FIELD
AutoCAD SHX Text
DUPLEX RAW WATER PUMP CONTROL PANEL (EXST, SEE PI01)
AutoCAD SHX Text
TO NEW COMMON INFLUENT ANALYZERS SEE DWG PI01
AutoCAD SHX Text M-4
AutoCAD SHX Text M-3
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
KQI
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text
YL
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AAH
AutoCAD SHX Text
AutoCAD SHX Text
AAL
AutoCAD SHX Text
AutoCAD SHX Text
AIR
AutoCAD SHX Text
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
AAH
AutoCAD SHX Text
AutoCAD SHX Text
AIR
AutoCAD SHX Text
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text L S A
AutoCAD SHX Text L S A
AutoCAD SHX Text
AI
AutoCAD SHX Text
AI
AutoCAD SHX Text
AI
AutoCAD SHX Text
AI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
IN
AutoCAD SHX Text
HOA
AutoCAD SHX Text
HAND
AutoCAD SHX Text
IN
AutoCAD SHX Text
AUTO
AutoCAD SHX Text
PUMP RUN
AutoCAD SHX Text
ELAPSED TIME
AutoCAD SHX Text
SW
AutoCAD SHX Text
HOA
AutoCAD SHX Text
SW
AutoCAD SHX Text
RAW WATER PUMP NO. 3
AutoCAD SHX Text
WATER PLANT NO. 2 LOAD CENTER
AutoCAD SHX Text
VENDOR SUPPLIED
AutoCAD SHX Text
INFLUENT RATE CONTROL VALVE
AutoCAD SHX Text
VENDOR SUPPLIED
AutoCAD SHX Text
CHLORINE DIOXIDE
AutoCAD SHX Text
CONNECTION TO WATER PLANT
AutoCAD SHX Text
ALUM
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SIPHON CONTROL SOLENOID VALVE
AutoCAD SHX Text
EFFLUENT PUMP PROTECTION SWITCH
AutoCAD SHX Text
RAPID MIX
AutoCAD SHX Text
FLOC CHAMBER
AutoCAD SHX Text
SETTLING TUBE CHAMBER
AutoCAD SHX Text
FILTER
AutoCAD SHX Text
BACKWASH WASTE PIPE
AutoCAD SHX Text
WASTEWATER TO SEWER SYSTEM
AutoCAD SHX Text
BACKWASH RATE CONTROL VALVE
AutoCAD SHX Text
BACKWASH VALVE
AutoCAD SHX Text
BACKWASH SUPPLY
AutoCAD SHX Text
EFFLUENT RATE CONTROL VALVE
AutoCAD SHX Text
TP-4
AutoCAD SHX Text
TP-3
AutoCAD SHX Text
HEADLOSS GAUGE/SWITCH
AutoCAD SHX Text
WATER PLANT NO. 2 JUNCTION BOX
AutoCAD SHX Text
MULTIPLE CONNECTIONS TO WATER PLANT NO. 1 CONTROLLER
AutoCAD SHX Text M
AutoCAD SHX Text
FE
AutoCAD SHX Text
AutoCAD SHX Text
FIT
AutoCAD SHX Text
AutoCAD SHX Text
TO WATER PLANT NO. 1 CONTROLLER
AutoCAD SHX Text
OPERATOR SAMPLE
AutoCAD SHX Text
TURBIDITY
AutoCAD SHX Text
FILTER TO WASTE VALVE
AutoCAD SHX Text
CONTINUED FROM DRAWING PI01
AutoCAD SHX Text
AIT 303
AutoCAD SHX Text pH
AutoCAD SHX Text
NOTE 5
AutoCAD SHX Text
LT
AutoCAD SHX Text
AutoCAD SHX Text
FROM BACKWASH
AutoCAD SHX Text
SUPPLY FLOW METER
AutoCAD SHX Text
2-PI01
AutoCAD SHX Text
FROM RAW WATER PUMP
AutoCAD SHX Text
DISCHARGE HEADER
AutoCAD SHX Text
1-PI01
AutoCAD SHX Text
TO WATER PLANT NO. 1
AutoCAD SHX Text
DISCHARGE HEADER
AutoCAD SHX Text
3-PI01
AutoCAD SHX Text
FROM WATER PLANT
AutoCAD SHX Text
NO. 1 DISCHARGE HEADER
AutoCAD SHX Text
5-PI01
AutoCAD SHX Text
TO WATER PLANT NO. 1
AutoCAD SHX Text
BACKWASH SUPPLY
AutoCAD SHX Text
4-PI01
AutoCAD SHX Text
120V NOTE 7
AutoCAD SHX Text BOUNDARY OF WATER PLANT NO. 2 SUPPLIER SCOPE OF SUPPLY. CONDUIT, WIRING, AND PIPING BY CONTRACTOR AS SPECIFIED/REQUIRED.
AutoCAD SHX Text
AIT
AutoCAD SHX Text
AutoCAD SHX Text
TRB
AutoCAD SHX Text
VENDOR SUPPLIED EQUIPMENT REF SPEC SEC 46 07 13
AutoCAD SHX Text
HIGH SERVICE PUMPS
AutoCAD SHX Text
DISTRIBUTION LOOPS (NOTE 6)
AutoCAD SHX Text L S A
AutoCAD SHX Text
PAHH
AutoCAD SHX Text
AutoCAD SHX Text
PAHH
AutoCAD SHX Text
AutoCAD SHX Text
PALL
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
DISTRIBUTION LINE PRESSURE
AutoCAD SHX Text
ELEVATED STORAGE TANK LEVEL
AutoCAD SHX Text
PALL
AutoCAD SHX Text
AutoCAD SHX Text
DO
AutoCAD SHX Text
DI
AutoCAD SHX Text
DI
AutoCAD SHX Text
ELEVATED STORAGE TANK
AutoCAD SHX Text
EXST PIPE (TYP) NOTE 1
AutoCAD SHX Text
NEW PIPE (TYP) NOTE 1
AutoCAD SHX Text
GROUND STORAGE TANK (GST)
AutoCAD SHX Text
NOTE 8
AutoCAD SHX Text
LIT
AutoCAD SHX Text 500A
AutoCAD SHX Text
ELEVATED STORAGE TANK
AutoCAD SHX Text
LIT
AutoCAD SHX Text 500A
AutoCAD SHX Text
AI
AutoCAD SHX Text
AI
AutoCAD SHX Text
NOTE 8
AutoCAD SHX Text
TO SURFACE WASH SYSTEM NOTE 9
AutoCAD SHX Text
NOTE 10
AutoCAD SHX Text
ZM CARTER
AutoCAD SHX Text
DL WILGES
AutoCAD SHX Text
APRIL 24, 2019
AutoCAD SHX Text
SA WARREN
AutoCAD SHX Text
DD ERIKSON
AutoCAD SHX Text
AutoCAD SHX Text
REISSUE BID PACKAGE
AutoCAD SHX Text
ZMC
AutoCAD SHX Text
SAW
AutoCAD SHX Text
DDE
AutoCAD SHX Text 6-19-20
AutoCAD SHX Text
WATER PLANT NO. 2
AutoCAD SHX Text
VIA RADIO SIGNAL
VIA FIBER OPTIC & HARDWIRE
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
PIPING PLAN
MP01 1
AS NOTED
AM ROMERO
DL WILGES
APRIL 24, 2019
DK MATHIAS
LJ LIESCHNER
1 REISSUE BID PACKAGE AMR DKM LJL 6-19-20
OFFICE
RESTROOM
CHLOR. STOR.
MECH
PROCESS RM
PIPING PLAN
N
O
R
T
H
6" PVC RAW WATER LINE
4" PVC TRANSFER LINE
4" DIP BACKWASH LINE
DRAIN WELL
FD
LIQUID AMMONIUM
SULFATE TANK AND PUMP
PIPING
CHANNEL
WATERBOY
UNIT NO. 1
WATERBOY
UNIT NO. 2
PIPING CHANNEL
ALUM TANK
RAW WATER PUMP NO. 2
RAW WATER PUMP NO. 3
ON EQUIPMENT PAD PER
DETAIL THIS DRAWING
RAW WATER PUMP NO. 1
CHLORINE
DIOXIDE SYSTEM
SEE NOTE 3
NOTES:
1. SEE REFERENCE DRAWINGS FOR PIPING DESIGN BY WATER BOY
MANUFACTURER.
SCALE:
MP01
NONE
A-MP01
EFFLUENT CONNECTION
TO WATERBOY UNIT NO. 2
SEE NOTE 1
CONNECT TO
EXISTING TEE
PIPING
CHANNEL
GRATING
3"
2"
3. SEE SPECIFICATION SECTION 46 30 13 FOR DESCRIPTION OF
WORK REQUIRED IN THIS AREA.
SEE NOTE 2
2. EXISTING PUMP SHALL BE INSTALLED ON NEW ALUM FEED
TOWER. MOUNT NEW TOWER ON EXISTING SUPPORTS. SEE
SPECIFICATION SECTION 46 30 13.
PI01-TP04
PI02-TP03
WATERBOY UNIT NO.
2 BACKWASH SUPPLY
CONNECTION SEE
NOTE 1
16" PVC RAW WATER LINE
SCALE: 1/4"=1'-0"
pH ANALYZER
AIT-303(pH)
CL2 RESIDUAL
ANALYZER
TURBIDITY
ANALYZER
INFLUENT WATER
AIT-103 (pH)
AIT-104 (TURBIDITY)
RAW WATER PUMP NO. 3
PI01-TP01
PI01-TP02
PI01-TP03
ALUM PUMP NO. 1
ALUM PUMP NO. 2
SCALE:
B-MP01
MP01
1/2" = 1'-0"
N
O
R
T
H
4. SEE DRAWING PI01 AND SPECIFICATION SECTION 46 07 13 FOR
MODIFICATIONS TO EXISTING INFLUENT AND EFFLUENT PIPING
FOR WATERBOY UNIT NO. 1.
5. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS TO ENSURE
NEW EQUIPMENT WILL FIT IN EXISTING SPACE.
6. CONTRACTOR TO FIELD ROUTE NEW CHEMICAL FEED PIPING
FOR ALUM AND CHLORINE DIOXIDE FROM FEED PUMPS TO
INFLUENT AT WATERBOY UNIT NO. 2. FEED PIPING SHALL BE 1"
PVC PIPE AND FITTINGS. PROVIDE SHUTOFF VALVES AT
CONNECTIONS TO PUMP AND INJECTION POINT.
PI02-TP02
PI01-TP05
2" GATE VALVE
4"X2" REDUCER
4" CHECK VALVE
4" GATE VALVE
PI02-TP01
SEE NOTE 4
EXST CHLORINE
STORAGE AND
FEED SYSTEM
CONNECT TO
EXISTING TEE
7. WATERBOY SUPPLIER TO PROVIDE INSTRUCTIONS AND DETAILS
FOR ANCHORING AND GROUTING TANK ON EXISTING CONCRETE
BASE.
102678
LARRY J. LEISCHNER
06/19/20
M
I N
T
M
I N
NOTES:
1. ANCHOR BOLT/ROD SIZE AND LOCATION TO SUIT
EQUIPMENT.
2. DOWELS AROUND PERIMETER ARE NOT REQUIRED
FOR HOUSEKEEPING PADS FOR EQUIPMENT WHICH
DOES NOT REQUIRE AND ANCHORAGE.
3. FOR FRAME MOUNTED PUMPS, COORDINATE PAD
DIMENSIONS WITH MANUFACTURER.
INTERIOR EQUIPMENT PAD DETAIL
SCALE: NONE
2" MIN (TYP)
5" MIN (TYP)
ROUGHENED SURFACE
ANCHOR BOLT CAST
IN PAD WHERE 1 > 8"
(ALTERNATE)
4#12 DOWEL AROUND
PERIMETER FOR NEW
SLAB CONSTRUCTION
(ALTERNATE)
EXISTING OR
NEW SLAB
4#12 EW
EQUIPMENT PAD
EQUIPMENT BASE
ANCHOR ROD (EXTEND
INTO SLAB 4" MIN
WHERE 1 < 8")
GROUT (1" MIN)
#4@12 ADHESIVE ANCHORED
REINFORCING AROUND PERIMETER;
(FOR NEW OR EXISTING SLAB
CONSTRUCTION)
8. PROVIDE SAMPLE LINE AND TURBIDIMETER. SAMPLE TAP SHALL
BE IN COMBINED FILTER EFFLUENT LINE.
SEE NOTE 8
COMBINED FILTER
EFFLUENT TURBIDITY
AIT-302
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
A-MP01
AutoCAD SHX Text
DETAIL
B-MP01
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
DEMOLITION ONE-LINE DIAGRAM
DE01 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
NOTES:
ELECTRICAL DEMOLITION ONE-LINE DIAGRAM
WATER PLANT NO.1
CONTROLLER
75KVA TRANSFORMER 12,470V-PRI 208Y/120V 3Ø,
4W, SEC, NEMA 3R
200A, 3P, 600V W/GND LUG NEMA 4X STAINLESS
STEEL FUSIBLE DISC, SW
200A, 3P, 600V W/GND LUG WALL MOUNT MANUAL TRANSFER
SWITCH NEMA 4X STAINLESS STEEL DOUBLE THROW DISC. SW.
W/ 200A HEAVY DUTY 4P, 4W TYPE 4X RECEPTACLE
2 1/2"C-3#3/0, 1#1/0G NOTE 5
PANEL A
RAW WATER PUMPS PNL
PUMP
#1
PUMP
#2
ELAPSED
TIME
METERS
PUMP ON
PUMP OFF
PUMP SELECTOR
#1 #2
ETM ETM
1. DEMOLISH AND SALVAGE EXISTING TRANSFORMER.
2. DEMOLISH AND SALVAGE EXISTING DISCONNECT.
3. DEMOLISH AND SALVAGE MANUAL TRANSFER SWITCH AND GENERATOR
PLUG.
4. DEMOLISH AND SALVAGE EXISTING PANEL A.
5. DEMOLISH EXISTING CONDUIT AND WIRE.
6. COORDINATE WITH OWNER FOR STORAGE OF ALL SALVAGED EQUIPMENT.
7. REMOVE EXISTING WIRING. LEAVE CONDUIT IN PLACE.
NOTE 1
2 1/2"C-3#3/0, 1#1/0G NOTE 5
2 1/2"C-3#3/0, 1#1/0G NOTE 5
NOTE 2
NOTE 3
NOTE 4
NOTE 7
5 5
TRAILER MOUNTED
EMERGENCY
GENERATOR
(BY OTHERS)
3#2(15KV)-4" DUCT
200A, 3P, 600V W/GND LUG NEMA 3R DISC, SW
116530
ERNEST E. LEAF
8. CONTRACTOR TO COORDINATE WITH OWNER FOR ALL PHASING AND
DEMOLITION OF EXISTING EQUIPMENT. DEMOLITION SHOULD BE STAGED
TO MINIMIZE THE OPERATIONAL IMPACT.
06/19/20
LEGEND:
DEMOLITION
MM
M
D
A
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
POWER DEMOLITION PLAN
DE02 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
OFFICE
RESTROOM
CHLOR. STOR.
MECH
PROCESS RM
POWER PLAN
SCALE: 1/4"=1'-0"
N
O
R
T
H
DE02
SCALE: 1/2"=1'-0"
RESTROOM
A-DE02
N
O
R
T
H
XFR
T
T
MECH
116530
ERNEST E. LEAF
NOTE 3
EXST WATER PLANT NO. 1
LOAD CENTER AND
WIREWAY
CL2 RESIDUAL
ANALYZER
TURBIDITY
ANALYZER
EXST WP/GFI
CHEMICAL
FEEDER OUTLET
NOTE 1
NOTE 4
EXST MTU CONTROL
PANEL
EXST WATER PLANT NO. 1
CONTROL PANEL
NOTES:
1. DEMOLISH AND SALVAGE EXISTING TRANSFORMER.
2. DEMOLISH AND SALVAGE EXISTING DISCONNECT.
3. DEMOLISH AND SALVAGE MANUAL TRANSFER SWITCH AND GENERATOR
PLUG.
4. DEMOLISH AND SALVAGE EXISTING PANEL A.
5. DEMOLISH EXISTING CONDUIT AND WIRE.
6. COORDINATE WITH OWNER FOR STORAGE OF ALL SALVAGED EQUIPMENT.
7. CONTRACTOR TO COORDINATE WITH OWNER FOR ALL PHASING AND
DEMOLITION OF EXISTING EQUIPMENT. DEMOLITION SHOULD BE STAGED
TO MINIMIZE THE OPERATIONAL IMPACT.
NOTE 2
NOTE 5 NOTE 5
NOTE 5
06/19/20
LEGEND:
DEMOLITION
AutoCAD SHX Text
DETAIL
A-DE02
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
ELECTRICAL ONE-LINE DIAGRAM
EO01 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
NOTES:
1. SEE DRAWING GG03 FOR ELECTRICAL LEGEND.
2. SEE DRAWING EW01 FOR PANEL A SCHEDULE.
ELECTRICAL ONE-LINE DIAGRAM
1.5 1.5
1/4
ALUM
METER
PUMP
WATER
PLANT
NO. 2
LOAD
CENTER
WATER PLANT NO.2
JUNCTION BOX
M-3 M-4
TRANSFER
PUMP NO.3
TRANSFER
PUMP NO.4
FLOC
MOTOR
WATER PLANT NO.1
CONTROLLER
3. PROVIDE 4-4/0, 1-#4G IN EXISTING UNDERGROUND CONDUIT TO WATER PLANT # 2 LOAD
CENTER. EXTEND CONDUIT FROM STUB UP TO LOAD CENTER.
4. REFURBISH RAW WATER PUMP CONTROL PANEL TO ADD PROVISIONS (BREAKERS,
STARTERS, CONTROLS) FOR ADDITIONAL WATER PUMP. SEE DRAWING IS01 AND
SPECIFICATION SECTION 40 96 15 FOR DETAILS.
5. PROVIDE 3-#10, 1-#10G FROM RAW WATER PUMP CONTROL PANEL TO NEW RAW WATER
PUMP. EXTEND CONDUIT FROM STUB UP TO CONTROL PANEL AND MOTOR.
CKT 38, 40, 42, EXST 1 1/4"C,
4-4/0, 1-#4G (NOTE 3)
NOTE 4
RAW WATER
PUMP NO.3
NOTE 5
6. WHERE NEW EQUIPMENT IS INSTALLED VERIFY CONDITION OF BUILDING GROUNDING
SYSTEM. CONNECT NEW EQUIPMENT TO EXISTING GROUNDING SYSTEM AND TEST
GROUNDING CONNECTION PER NEC 250.53.
150KVA OIL FILLED PAD MOUNTED
TRANSFORMER 12,470V-PRIMARY
208Y/120V 3Ø, 4W, SEC, NEMA 3R
400A, 3P, 600V W/GND LUG
NEMA 4X STAINLESS STEEL
FUSIBLE DISC, SW
400A, 3P, 600V W/GND LUG WALL MOUNT
MANUAL TRANSFER SWITCH NEMA 4X
STAINLESS STEEL DOUBLE THROW DISC.
SW. W/ 400A HEAVY DUTY 4P, 4W TYPE 4X
RECEPTACLE
NOTE 9
NEW
PANEL A
2 SETS OF 1-4"C, 4-4/0,
AND 1-#2 GND
7. EQUIPMENT BY WATER PLANT VENDOR.
NOTE 7
RAW WATER PUMPS PNL
PUMP
#1
PUMP
#2
ELAPSED
TIME
METERS
PUMP ON
PUMP OFF
WATER
PLANT
NO. 1
LOAD
CENTER
8. SEE SHEET DE01 FOR DEMOLITION PLAN.
9. NEW PANEL A, 208/120V 3 PHASE, 4 WIRE, IN NEMA 1 ENCLOSURE. 54 CIRCUIT PANEL
400A MCB. SEE SHEET EW01 FOR PANEL SCHEDULE.
10. CONTRACTOR TO VERIFY METER SOCKET RATINGS. COORDINATE METER AND
ASSOCIATED ITEMS WITH AEP TO PROVIDE EQUIPMENT FOR NEW 150KVA SERVICE.
MATCH NEW BUILDING ELECTRICAL SERVICE.
ETM ETM ETM
NOTE 10
11. PROVIDE GENERATOR PLUG TO MATCH EXISTING.
12. PULL NEW WIRE TO REFURBISHED RAW WATER PUMPS PANEL. 4-1/0, 1-#8G IN
EXISTING CONDUIT.
13. ITEMS SHOWN GREY ARE EXISTING. ITEMS SHOWN BLACK ARE NEW
14. NEW ALUM METER PUMP CONNECT TO EXISTING WP/GFI OUTLET. CORD SET PRE-WIRED
AND PROVIDED BY MANUFACTURER.
NOTE 11
NOTE 12
NOTE 14
1" C, 2-#12, 1-#12 G
CONNECT TO EXISTING
GROUND MAT (NOTE 6)
NOTE 6
INFLUENT
PH METER
INFLUENT
TURBIDITY
METER
PUMP
#3
1.5 1.5
15. SEE SECTION 40 96 15 FOR HIGH SERVICE PUMP CONTROL PANEL MODIFICATION
DETAILS.
FROM MTU/DIST. LINE
PRESSURE SETPOINTS
FOR HSP START/STOP
NOTE 15
PUMP HOA
TO RAW WATER PUMP
CONTROL PANEL/PUMP
START/STOP SIGNAL
PER PUMP
16. CONTRACTOR TO PROVIDE ALL NEW SERVICE EQUIPMENT INCLUDING PAD MOUNTED
TRANSFORMER, MAIN DISCONNECT, MANUAL TRANSFER SWITCH, GENERATOR PLUG,
AND PANEL A. ALL OUTAGES AND SERVICE UPGRADE PHASING TO BE COORDINATED
WITH OWNER.
2 SETS OF 1-4"C,
4-4/0, AND 1-#2 GND
2 SETS OF 1-4"C, 4-4/0, AND
1-#2 GND
116530
ERNEST E. LEAF
2-4"C, 3-#2 (15KV)
06/19/20
17. BY WATER TREATMENT PLANT MANUFACTURER.
NOTE 17
NOTE 6
COMBINED FILTER
EFFLUENT TURBIDITY
METER
MMM
M
M
D
A
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
POWER PLAN
EP01 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
OFFICE
RESTROOM
CHLOR. STOR.
MECH
PROCESS RM
NOTES:
1. MOUNT ALL RECEPTACLES PER ADA REQUIREMENTS.
2. CONDUITS LEAVING CHLORINE ROOM MUST HAVE SEAL OFF
FITTINGS AND FILLED WITH SILICON SEALER.
3. CONTRACTOR TO COORDINATE ELECTRICAL REQUIREMENTS
FOR WATER PLANT EQUIPMENT WITH PLANT EQUIPMENT VENDOR
AND FURNISH AND INSTALL ALL REQUIRED POWER, CABLE,
CONDUIT, EQUIPMENT, ECT. AS REQUIRED FOR A COMPLETE AND
OPERATIONAL WATER PLANT CONTROL SYSTEM, NOT ALL
REQUIRED ITEMS MAY BE SHOWN ON THESE DRAWINGS.
1 1"C-3#10, 1#10G FROM RAW WATER PUMP PANEL TO MOTORS (EXISTING).
2 1"C-EXISTING BELOW GRADE FROM NEW RAW WATER PUMP STUBBED UP
BELOW RWP CONTROL PANEL. PROVIDE 3-#10, #10G IN EXISTING CONDUIT.
6 REPLACE EXISTING pH ANALYZER (AIT-303). REUSE EXISTING CONDUIT
AND WIRE.
7 NEW PLANT NO. 2 MAGNETIC METER. FEED FROM NEW PLANT NO. 2 LOAD
CENTER. 2-#12, 1-#12 G, 3/4" C.
KEYNOTES:
POWER PLAN
WALL-MOUNTED MANUAL
TRANSFER SWITCH WITH HEAVY DUTY
RECEPTACLE
PANEL A
DUPLEX
RAW WATER PUMP
PANEL (NOTE 4)
DUPLEX
HIGH SERVICE
PUMP PANEL
CONTROLLER
EXST WATER PLANT NO. 1
LOAD CENTER AND
WIREWAY
pH ANALYZER
CL2 RESIDUAL
ANALYZER
TURBIDITY
ANALYZER
4. EXISTING RAW WATER PUMP CONTROL PANEL TO BE
REFURBISHED TO ADD FEEDER AND CONTROLS FOR NEW RAW
WATER PUMP TO MATCH EXISTING.
NEW WATER PLANT NO. 2 LOAD
CENTER AND WIREWAY (NOTE 3)
PNL A-38,40,42
INFLUENT WATER
AIT-103 (pH)
AIT-104 (TURBIDITY)
5. NEW ELECTRICAL SERVICE EQUPMENT SEE SHEET EO01 ONE-LINE.
SEE DE01 FOR EXISTING EQUPMENT DEMOLITION DETAILS.
6. CONTRACTOR TO VERIFY EXISTING GROUNDING SYSTEMS ARE
ADEQUATE FOR CONNECTION TO NEW EQUIPMENT. REPLACE AS
NEEDED. TEST GROUNDING CONNECTION PER NEC 250.53.
4 CONNECT NEW ALUM METERING PUMP TO EXISTING WP/GFI RECEPTACLE VIA
MANUFACTURER SUPPLIED AND WIRED CORDSET.
EXST WP/GFI
CHEMICAL
FEEDER OUTLET
NEW ALUM METERING
PUMP
EXST CHLORINE DIOXIDE
PUMP CONTROL PANEL
7. SEE DE01 FOR EXISTING EQUIPMENT DEMOLITION DETAILS.
5 CHLORINE DIOXIDE SYSTEM SUPPLIER TO PROVIDE CHLORINE DIOXIDE SYSTEM/CONTROL
PANEL MODIFICATIONS PER SPECIFICATION SECTION 46 30 13, WORK INCLUDES BUT NOT
LIMITED TO REMOVAL OF VFD AND COMPLETE DESIGN, PROVIDE ITEMS LOCAL TO THE
CHLORINE DIOXIDE SYSTEM SKID: MOTOR STARTER, FLOW METER, CONTROL VALVES, PIPING
AND FITTINGS, CONDUIT CABLES AND PROGRAMMING. CONTRACTOR SHALL PROVIDE FEED
PIPING BETWEEN CHLORINE DIOXIDE SKID AND WATER PLANTS AS REQUIRED.
3 1 1/4"-EXISTING CONDUIT FROM PANEL "A" TO (NEW PLANT LOAD CENTER #2) EXTEND
CONDUIT UP FROM GRADE TO CONTROL PANEL. PULL NEW 4-4/0, 1-#4G. PROVIDE ABOVE
GROUND CONDUIT CONNECTION FROM STUB-UP TO LOAD CENTER.
8 NEW PLANT NO. 1 MAGNETIC METER. FEED FROM EXISTING PLANT NO. 1 CONTROL
PANEL, 2-#12, 1-#12 G, 3/4" C.
NOTE 10
NOTE 6
RAW WATER
PUMP #3
PNL A-15,17,19
PNL A-44
9 EXISTING 4" CONDUITS TO UTILITY/ METERS.
EXISTING CHLORINE
DIOXIDE SYSTEM
SCALE: 1/4"=1'-0"
EXST MTU CONTROL
PANEL
N
O
R
T
H
NEW WATER PLANT
NO. 2 JUNCTION BOX
EXST WATER
PLANT NO. 1
CONTROL PANEL
10 2 SETS OF 1-4"C, 4-4/0, #2 GROUND.
8. CONTRACTOR TO PROVIDE NEW 150KVA OIL FILLED PAD MOUNTED
TRANSFORMER AND PAD PER DETAIL ON EP02.
9. CONTRACTOR TO PROVIDE ALL NEW SERVICE EQUIPMENT.
CONTRACTOR TO COORDINATE WITH OWNER REGARDING REQUIRED
OUTAGES AND NEW SERVICE PHASING.
EP01
SCALE: 1/2"=1'-0"
RESTROOM
A-EP01
N
O
R
T
H
XFR
T
T
MECH
NOTE 9
116530
ERNEST E. LEAF
10. EXISTING TRANSFORMER PAD.
11 2-4" CONDUITS, 3-#2 (15KV) TO EXISTING OVERHEAD SERVICE POLE/METER.
12 INSTRUMENTATION AND CONTROLS CONDUITS: CONTRACTOR TO VERIFY EXISTING
CONDUIT AND AVAILABILITY. ADD NEW 3/4" CONDUIT AS REQUIRED.
T
T
NOTE 8
06/19/20
EFFLUENT
TURBIDITY AIT-302
PNL A-35
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL
A-EP01
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
ELECTRICAL DETAILS
EP02 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
F
I
N
S
U
B
G
R
A
D
E
4/0 STRANDED
BARE COPPER
2'-6" BURIAL DEPTH
MINIMUM
EXOTHERMIC WELD
3/4"x10'-0" COPPER CLAD STEEL
GROUND ROD
REBAR
EXOTHERMIC
CONNECTION
4/0 BARE COPPER TO GROUND
GRID
GROUND ROD DETAIL
REBAR GROUNDING DETAIL
NTS
NTS
BOND REBAR TO
GROUND RING
CONCRETE PAD
GROUND ROD
TERMINATE GROUNDING
CONDUCTOR & NEUTRAL
BONDING JUMPER TO THE
GROUNDING LUG
TRANSFORMER
WINDINGS &
COOLING FINS
HIGH VOLTAGE
LOW
VOLTAGE
TRANSFORMER AND DISTRIBUTION PLAN
SCALE: 1/2"=1'-0"
116530
ERNEST E. LEAF
2-4" CONDUITS TO MAIN
DISCONNECT
4" CONDUIT TO BUILDING
METER/SERVICE POLE
#4/0 BARE COPPER
#4 REBAR @ 12"OC EW
TOP & BOTTOM
GALVANIZED POST-INSTALLED ANCHOR
BOLT (TYP) - SIZE, LOCATION AND
QUANTITY PER EQUIPMENT
MANUFACTURER RECOMMENDATIONS
(USE MIN 3/4"Ø BOLT @ 6'-0" MAX SPA)
(TYP)
T
Y P
T
Y P
(TYP)
TRANSFORMER EQUIPMENT FOUNDATION PLAN
SCALE: 1/2"=1'-0"
A-EP02 A-EP02
B E
P
B E
P
M
I N
T
Y P
NOTE:
ANCHOR BOLTS TO BE PLACED AS NEEDED PER EQUIPMENT MANUFACTURER RECOMMENDATIONS.
GRADE
(MIN,
TYP)
GALVANIZED POST-INSTALLED ANCHOR
BOLT WITH 6" MIN EMBEDMENT (TYP)
SCALE:
EP02
1/2" = 1'-0"
GRADE
(TYP)
(MIN,
TYP)
1'-0"
EQUIPMENT LENGTH + 1'-0" (+/-)
E Q
U I P
M E
N
W
I D
H
3" CLR
C
L R
4 1/2"3" CLR
4 1/2"
C
L R
C
L R
C
O M
P A
C T
E D
C O
A R
E
G G
R E
G A
T E
SCALE:
EP02
1/2" = 1'-0"
BLOCKOUT SIZE AND LOCATION
TO SUIT EQUIPMENT PROVIDED
06/19/20
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
A-EP02
AutoCAD SHX Text
SECTION
B-EP02
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
PANEL SCHEDULE
EW01 1
AS NOTED
MJ HILL
DL WILGES
APRIL 24, 2019
EE LEAF
EE LEAF
1 REISSUE BID PACKAGE MJH EEL EEL 6-19-20
NOTES:
1. EXISTING PANEL A TO BE REPLACED WITH NEW 208Y/120V 54
CIRCUIT PANEL. PRESERVE EXISTING WIRE TO THE EXTENT
POSSIBLE FOR CONNECTION TO NEW PANEL/BREAKERS. IF
CIRCUITS/WIRES CANNOT BE RE-TERMINATED PULL NEW
CIRCUIT/WIRE FROM NEW PANEL TO EXISTING DEVICE.
2. OUTAGE/REPLACEMET OF PANEL A SHALL BE SCHEDULED WITH
USDA AND MAINTENANCE PERSONNEL.
3. NEW CIRCUIT BREAKER REQUIRED FOR ALL CIRCUITS. PROVIDE
NEW WIRING FOR CIRCUITS SHOWN WITH WIRING
REQUIREMENTS. CONTRACTOR TO VERIFY CIRCUITS AND
PROVIDE UPDATED PANEL CIRCUIT DIRECTORY.
4. CONTRACTOR TO PROVIDE NON-FADING ARC FLASH
RATINGS/LABELS FOR NEW EQUIPMENT.
NOTE 3
116530
ERNEST E. LEAF
06/19/20
5. BREAKER SPACES RESERVED FOR OTHER PROJECT (IRRIGATION
SYSTEM).
NOTE 5
NOTE 5
1 2
C A
R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
AT FULL SIZE
IN
cm0 1
3 4
USDA-APHIS-PPQ
MOORE AIR BASE
REPAIRS TO WATER TREATMENT FACILITY
EDINBURG, TEXAS
27100.14
Texas Firm Registation No.: F-174
RAW WATER PUMP CONTROL PANEL
MODIFICATIONS
IS01 1
AS NOTED
ZM CARTER
DL WILGES
APRIL 24, 2019
SA WARREN
DD ERIKSON
1 REISSUE BID PACKAGE ZMC SAW DDE 6-19-20
RAW WATER PUMPS SCHEMATIC MODIFICATIONS
M3
M3
M3
CS3
CS3
SPARE
SPARE
TO TB1
PUMP
ON/OFF STATUS
TO TB1
CONTROL SW IN
HAND POSITION
TO TB1
CONTROL SW IN
AUTO POSITION
R
G
M3
ETM
M3
PUSH TO TEST PUMP 3 ON
M3
M3
PUSH TO TEST PUMP 3 OFF
ELAPSED TIME METER PUMP 3
LIGHT
LIGHT
HAND
AUTO
CR5-1
OL
(3)
ØF
HAND OFF AUTO
CONTROL SWITCH "CS" 3
RAW WATER PUMP 3
NOTES:
1. ITEMS SHOWN GRAY ARE EXISTING; ITEMS SHOWN IN
BLACK ARE NEW, BY CONTRACTOR.
120V
CR1
CR2
PUMP NO. 1
PUMP NO. 2
NO. 1 NO. 2
RAW PUMPS SELECTER
SWITCH "SW"1
208V
2. EXISTING RAW WATER PUMP CONTROL PANEL IS SIZED
WITH SPACE FOR CONTRACTOR TO ADD
INSTRUMENTATION AND CONTROLS FOR THE THIRD
PUMP. IT IS CONTRACTOR'S RESPONSIBILITY TO
PROVIDE AND APPROPRIATELY INSTALL THE SWITCHES
AND DEVICES SHOWN, IN THE SPACE AVAILABLE. SEE
ELECTRICAL ONE LINE DIAGRAM EO01.
CRA
CR4
CR5
RWP-3 START/STOP
SIGNAL FROM WATER
PLANT CONTROLLER
RWP-2 START/STOP
SIGNAL FROM WATER
PLANT CONTROLLER
RWP-1 START/STOP
SIGNAL FROM WATER
PLANT CONTROLLER
CR3
CR4-1
CR3-1
LEGEND:
DEMOLITION
PUMP 3
RUN
G
STOP
HAND OFF AUTO
R
RAW WATER PUMP CONTROL PANEL SWING-OUT DOOR MODIFICATIONS
32.8
COVER HOLE
WITH PLATE
06/19/20
NOTE 3 (TYP)
3. NEW HARDWARE SHALL BE OF THE SAME MAKE AND
MODEL AS EXISTING.
134005
DEVIN D. ERIKSON
DATE
REV
DATE
DATE
DESIGNER
CHECKER
COMPANY CONFIDENTIAL
SCALE:
FILE:
MANAGER
DATE TITLE
CLIENT
PROJECT CODE DRAWING SHEET
OF
ENGINEER
THIS DOCUMENT AND ALL INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF WESTECH AND/OR ITS AFFILIATES. THE DESIGN CONCEPTS AND INFORMATION CONTAINED HEREIN ARE PROPRIETARY TO WESTECH AND ARE SUBMITTED IN CONFIDENCE. THEY ARE NOT TRANSFERABLE AND MUST BE USED ONLY FOR THE PURPOSE FOR WHICH THE DOCUMENT IS EXPRESSLY LOANED. THEY MUST NOT BE DISCLOSED, REPRODUCED, LOANED OR USED IN ANY OTHER MANNER WITHOUT EXPRESS WRITTEN CONSENT OF WESTECH. IN NO EVENT SHALL THEY BE USED IN ANY MANNER DETRIMENTAL TO THE INTEREST OF WESTECH. ALL PATENT RIGHTS ARE RESERVED. UPON THE DEMAND OF WESTECH, THIS DOCUMENT, ALONG WITH ALL COPIES AND EXTRACTS, AND ALL RELATED NOTES AND ANALYSES, MUST BE RETURNED TO WESTECH OR DESTROYED, AS INSTRUCTED BY WESTECH. ACCEPTANCE OF THE DELIVERY OF THIS DOCUMENT CONSTITUTES AGREEMENT TO THESE TERMS AND CONDITIONS. IF THIS DOCUMENT COMES INTO THE POSSESSION OF A THIRD-PARTY THAT IS NOT A PARTY TO A NON-DISCLOSURE AGREEMENT WITH WESTECH OR OTHERWISE AUTHORIZED TO POSSESS OR USE THIS DOCUMENT, SUCH PARTY MUST IMMEDIATELY RETURN THIS DOCUMENT TO WESTECH AND SHALL NOT USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER UNLESS AND UNTIL AUTHORIZED IN WRITING BY WESTECH TO DO SO. IF SUCH THIRD-PARTY DOES USE THIS DOCUMENT FOR AN UNAUTHORIZED PURPOSE, WESTECH WILL PURSUE ANY AND ALL REMEDIES AVAILABLE TO IT, AT LAW OR IN EQUITY, UNDER FEDERAL LAW AND/OR UNDER THE LAWS OF
THE COMMONWEALTH OF MASSACHUSETTS OR OTHER APPLICABLE LAW.
REV ECNDESCRIPTION DATE DWN CHKD APVD
WATERBOY PACKAGED WATER TREATMENT PLANT
WB-82 GENERAL ARRANGEMENT
USDA MOORE AIR BASE - EDINBURG, TX
1013-0001704001
1/2"=1'-0"
1 3 0PRELIM-1830309
JHC 1/27/2010
JHS 3/15/2010
TGL 1/27/2010
Water Technologies
Ames, IA
515-268-8400
S T
D
B
O R
D E
R X
B
A
T
P
L O
T
S
C A
L E
I N
T L
R
E F
PLAN VIEW
CAUTION: TUBE MODULE MATERIAL IS PLASTIC AND WILL BURN
IF EXPOSED TO FLAME, WELD SPATTER OR HIGH HEAT.
DO NOT USE CUTTING TORCH, WELDING EQUIPMENT, OPEN FLAME,
OR SMOKING MATERIALS IN THE VICINITY OF TUBE MODULES.
10'-1
OVERALL
7'-7
7'-4
" OVERALL
7'-6
EFFLUENT CONNECTION
AA
2" SCREWED INFLUENT
CONNECTION (MAX. INLET
PRESSURE = 75 PSI)
FLOCCULATION
COMPARTMENT
FLOCCULATOR
ASSEMBLY
TUBE SETTLING
COMPARTMENT
FILTER
COMPARTMENT
SIPHON CONTROL
SOLENOID VALVE
FLASH MIX
COMPARTMENT
BACKWASH
CONNECTION
FILTER-TO-WASTE
D
B
O R
D E
R X
B
A
T
P
L O
T
S
C A
L E
I N
T L
R
E F
DATE
REV
DATE
DATE
DESIGNER
CHECKER
COMPANY CONFIDENTIAL
SCALE:
FILE:
MANAGER
DATE TITLE
CLIENT
PROJECT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .