Phone (954) 792-4549

Fax: (954) 792-2221 www.AirQuestInc.com

6851 Southwest 45th Street, Fort Lauderdale, FL 33314

AirQuest Project #14073

Limited Pre-Renovation Report of Building Material Survey, Sampling and Evaluation of Asbestos- Containing Materials For:

US Forest Service Southern Research Station Athens Fire Lab 320 Green Street Athens, Georgia 30307

Prepared For:

Brad Dorsey, P.E.

Dorsey Engineering, Inc.

3449 B Lawrenceville Suwanee Road Suwanee, Georgia 30024

October 22, 2018 ii

CERTIFICATION PAGE

Limited Pre-Renovation Report of Building Material Survey, Sampling and

Evaluation of Asbestos-Containing Materials

US Forest Service Southern Research Station

Athens Fire Lab 320 Green Street

Athens, Georgia 30602

AirQuest Project #14073

Prepared For:

Brad Dorsey, P.E.

Dorsey Engineering, Inc.

3449 B Lawrenceville Suwanee Road

Suwanee, Georgia 30024

Prepared By:

AirQuest Environmental, Inc.

6851 Southwest 45th Street

Fort Lauderdale, Florida 33314

German Navarrete Traci-Anne Boyle, CIH, CSP Project Manager Asbestos Consultant #AX-60

October 22, 2018 iii

TABLE OF CONTENTS

PAGE

1 EXECUTIVE SUMMARY 1

2 INTRODUCTION AND SITE DESCRIPTION 3

3 SURVEY METHODS AND LABORATORY ANALYSIS 4

4 SUSPECT ASBESTOS-CONTAINING MATERIALS 6

5 CONCLUSIONS AND RECOMMENDED RESPONSE ACTION 8

6 LIMITATIONS 10

TABLES

Table 1 – Laboratory Analysis and Summary

APPENDICES

Appendix I – Certifications

Appendix II – Laboratory Report and Chain of Custody Record

Appendix III- Photographs

Appendix IV- Provided Diagram

Appendix V- Provided 2010 Asbestos Survey Report

Project #14073 1 Asbestos Survey

1 EXECUTIVE SUMMARY

AirQuest Environmental, Inc. (“AirQuest”) performed a limited survey for asbestos-containing materials (ACM) within the area designated as the “Future Fire Lab” (FKA “Wood Shop”) at the US Forest Service Southern Research Station Athens GA South Building, located at 320 Green Street, Athens, Georgia 30602 (“the site”). The survey was performed on October 10, 2018, by AirQuest Project Manager, German Navarrete, an EPA-accredited Asbestos Hazard Emergency Response Act (AHERA) Asbestos Inspector (see Appendix I).

The purpose of the survey was to locate and identify ACM within the interior and exterior building materials associated with the area of the SRS Athens GA South Building designated as the “Future Fire Lab” (FKA “Wood Shop”) prior to renovation activities. At the time of the inspection, AirQuest was provided with a 2010 asbestos survey report. The asbestos report included the South Building, North Building, Insectory, and Chemical and Insecticide Building.

The results of our observation and laboratory analysis identified the following ACM and/or previously identified ACM:

Homogenous

Area (HA)

Material Location

Percentage/

Type

Material

Condition/

Friability

Approximate

Quantity Category

HA 1:

TSI 4” Elbows

Future Fire Lab South Area Chilled Water Line

Wrap: ND Insulation 1: ND Insulation 2:

<1% Amosite Mastic: ND

Good/ Friable 15 SF

NESHAPs

RACM

Previously Identified Pipe Elbow Insulation

Wood Shop Cold Water Line @ Hot Water Heater

2% Amosite Unknown/ Friable Unknown

NESHAPs

RACM

NA Remaining Interior/ Exterior and Roof Building Materials/ Areas

NA NA NA Not in Scope

TSI-Thermal System Insulation SF- Square Feet ND- None Detected NA- Not Applicable NESHAP– National Emissions Standard for Hazardous Air Pollutants Friable- Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry.

jasonleeanderson Highlight

Project #14073 2 Asbestos Survey

National Emission Standards for Hazardous Air Pollutants (NESHAP) Category Recommendations:

• Category I: Category I nonfriable ACM refers to asbestos-containing packing, gaskets, resilient floor coverings, and asphalt roofing products.

• Category II: Category II nonfriable ACM refers to any material that is not classified under Category I.

• Regulated Asbestos Containing Material (RACM): RACM refers to friable ACM or a Category I nonfriable ACM that has become friable or a Category I nonfriable ACM that has been or will be subjected to sanding, grinding, cutting or abrading or a Category II nonfriable ACM that has a high probability of becoming crumbled, pulverized or reduced to powder by the forces expected to act on the material in the course of renovation or demolition activities.

o Renovation Activities: There is no regulatory guideline that requires removal of RACM unless it will be disturbed during renovation or remodeling activities. If RACM is to be impacted or removed, the removal must be conducted by a Georgia Licensed Asbestos Abatement Contractor, with prior notification to the appropriate County and the State of Georgia agencies.

At the request of the Client, the scope of the survey was limited to interior and exterior building materials associated with the area of the SRS Athens GA South Building designated as the “Future Fire Lab” (FKA “Wood Shop”). Sampling of remaining interior and exterior areas of the South Building, and the roof was not included in the scope of the survey.

Destructive sampling procedures were not used to access the interior of wall cavities, fire doors, or above hard ceilings. If any materials are encountered during renovation activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non-ACM through laboratory analysis.

Project #14073 3 Asbestos Survey

2 INTRODUCTION AND SITE DESCRIPTION

AirQuest performed a limited survey for ACM within the area designated as the “Future Fire Lab” (FKA “Wood Shop”) at the US Forest Service Southern Research Station Athens GA South Building, located at 320 Green Street, Athens, Georgia 30602.

The purpose of the survey was to locate and identify ACM within the interior and exterior building materials associated with the area of the SRS Athens GA South Building designated as the “Future Fire Lab” (FKA “Wood Shop”) prior to renovation activities. At the time of the inspection, AirQuest was provided with a 2010 asbestos survey report. The asbestos report included the South Building, North Building, Insectory, and Chemical and Insecticide Building.

The scope of services for this project consisted of the following five steps:

➢ Building Walk-Through and Observations,

➢ Bulk Sampling of Suspect ACM,

➢ Polarized Light Microscopy (PLM) Analysis of Bulk Samples,

➢ Hazard Assessment and Evaluation, and

➢ Final Report Preparation.

On October 10, 2018, AirQuest Project Manager, German Navarrete, conducted an asbestos sampling survey of suspect ACM associated with the pending renovations at the site.

The building was constructed of concrete block on a concrete slab foundation and finished with exterior brick. Thermal System Insulation (TSI) elbows with wrap, mastic, and insulation were present on the chilled water lines. Miscellaneous concrete pads were present in the south and northwest areas of the building.

Project #14073 4 Asbestos Survey

3 SURVEY METHODS AND LABORATORY

ANALYSIS

The sampling protocol used generally follows Asbestos Hazard Emergency Response Act (AHERA) guidelines. AHERA was promulgated by the United States Environmental Protection Agency (EPA) in 1987 and regulated public schools.

Suspect materials are differentiated into three categories: surfacing material, thermal system insulation, or miscellaneous material. Surfacing material is anything that is sprayed or troweled onto a surface; thermal system insulation is material used to insulate HVAC pipes, tanks, etc., and miscellaneous material is any other type of material. During the survey, surfacing and miscellaneous materials were observed.

A homogeneous area is defined as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. A homogeneous area is not limited to only one room, but can be found in several rooms. Sample selection in the building was determined by identifying the homogeneous areas and basing sampling locations upon these areas.

In conducting the building inspection in compliance with all local, state, and federal regulations, all suspected ACM which were accessible to the inspector, were either sampled to confirm the actual presence of asbestos, or assumed to contain asbestos.

Building areas between walls, under floors, under concrete slabs and above permanent ceilings, all of which could not be accessed, were not visually inspected nor were materials therein sampled as a part of this building inspection.

Due to the fact that over 3,600 different building products are recognized as asbestos-containing building materials, it cannot be said that all such products, which may be included in the subject building, have or could be identified.

Analysis was performed using Polarized Light Microscopy (PLM) with dispersion staining. The laboratory is rated proficient through National Institute of Standards and Technology- National Voluntary Laboratory Accreditation Program (NIST-NVLAP) for bulk asbestos analysis.

It is important to note that the method of bulk sample analysis, PLM, is not 100% absolute in the identification of ACM. There are many factors which may contribute to false negatives being reported. Some of the more common factors include non-homogeneity of the building material and the optical variations of the microscopist. In order to obtain an absolute analysis of a building material, any reported negative sample suspect of being asbestos or any material not sampled should be analyzed by Transmission Electron Microscopy (TEM) with energy dispersive x-ray analysis (EDAX) for bulk sample confirmation. Interpretation of TEM results must be viewed with caution as these procedures are not presently recognized by EPA regulations. However, they are useful analytical techniques for confirmation of non-friable materials when PLM results are inconclusive.

Project #14073 5 Asbestos Survey

Because of the inherent limitations of PLM Bulk Sample analysis, the Owner may elect to re-analyze the reported negative PLM samples by TEM to determine whether they may be regulated under the Asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP).

This analytical technique is described in the EPA Guidance Document, EPA/600 R-93/116, July 1993, Test Method – Method for the Determination of Asbestos in Bulk Building Materials. This method, Analytical Electron Microscopy (AEM), also referred to as TEM, can often be a reliable method for the detection and positive identification of asbestos in some bulk building materials, both friable and nonfriable. The method is particularly applicable to bulk materials that contain a large amount of interfering materials that can be removed by ashing and/or dissolution and contain asbestos fibers that are not resolved by PLM techniques. Many floor tiles and plasters would be included in the type of sample. In combination with suitable specimen preparation techniques, the AEM method can also be used to quantify asbestos concentrations.

The TEM analytical methodology is also referred to in an EPA Advisory, Federal Register, Vol.

59, No. 146, August 1, 1994, Advisory Regarding Availability of an Improved Asbestos Bulk Sample Analysis Sample Test Method; Supplementary Information on Bulk Sample Collection and Analysis. The Advisory states that this approach should be considered for the following circumstances: (10 Floor tiles which may contain thin fibers and which were analyzed under the 1982 PLM method and found not to be asbestos-containing; and (2) materials such as hard wall and acoustical plaster, stucco or other similar multi-layered materials or systems which were not analyzed and reported by layers (discrete strata).

NESHAP, 40 CFR Part 763, Section 61.141, revised July 1, 1996, defines ACM as any material containing more than one (1) percent asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM, that, when dry, can be crumbled, pulverized or reduced to a powder by hand pressure. If the asbestos content is less than ten (10) percent as determined by a method other than point counting by PLM, verify the asbestos content by point counting using PLM.

Estimates of quantities of ACM where given are based upon the identification of suspect materials.

Where suspect ACM are located behind walls, above ceilings, beneath carpeting, or other concealed conditions. Where the quantities cannot be verified, the estimate is based upon the conditions present during the survey. These estimates are not to be considered absolute and should be verified when the ACM is exposed.

Project #14073 6 Asbestos Survey

4 SUSPECT ASBESTOS-CONTAINING

MATERIALS

Five (5) homogeneous areas (HA) of suspect material were identified and a total twelve (12) samples were collected. The laboratory split the samples into layers, resulting in the analysis of twenty-three (23) samples. Sample descriptions and laboratory results are summarized in Table 1.

Sample locations and HAs identified to be ACM are described in Section 5.

A copy of the laboratory report and chain of custody record is included in Appendix II.

Photographs of each HA are included in Appendix III. A diagram provided by the Client is included in Appendix IV. The 2010 asbestos survey report provided by the Client is included in Appendix V.

Table 1 – Laboratory Analysis and Summary

Samples Collected on October 10, 2018

Sample

Number HA Location

Description of Suspect

Material

Asbestos Content

14073-01 1 South Area TSI 4” Elbows with Wrap and Insulation ND

14073-02 1 South Area TSI 4” Elbows with Wrap, Mastic, and Insulation ND

14073-03 1 South Area TSI 4” Elbows with Wrap and Two (2) Layers of Insulation

Wrap: ND Insulation 1: ND

Insulation 2:

<1% Amosite

14073-04 2 Northwest Area TSI 12” Pipe with Wrap, Mastic, and Insulation ND

14073-05 2 Northwest Area TSI 12” Pipe with Wrap and Insulation ND

14073-06 2 Northwest Area TSI 12” Pipe with Wrap and Insulation ND

14073-07 3 Southeast Area Black 4” Vinyl Floor Cove and Mastic ND

14073-08 3 Southeast Area Black 4” Vinyl Floor Cove and Mastic ND

14073-09 4 South Area Miscellaneous Concrete Pads ND

14073-10 4 Northwest Area Miscellaneous Concrete Pads ND

Project #14073 7 Asbestos Survey

Sample

Number HA Location

Description of Suspect

Material

Asbestos Content

14073-11 5 Exterior Northeast Area Brick Mortar ND

14073-12 5 Exterior Southeast Area Brick Mortar ND

HA- Homogenous Area ND- None Detected TSI-Thermal System Insulation

Project #14073 8 Asbestos Survey

5 CONCLUSIONS AND RECOMMENDED

RESPONSE ACTION

The results of our observation and laboratory analysis identified the following ACM and/or previously identified ACM:

Homogenous

Area (HA)

Material Location

Percentage/

Type

Material

Condition/

Friability

Approximate

Quantity Category

HA 1:

TSI 4” Elbows

Future Fire Lab South Area Chilled Water Line

Wrap: ND Insulation 1: ND Insulation 2:

<1% Amosite Mastic: ND

Good/ Friable 15 SF

NESHAPs

RACM

Previously Identified Pipe Elbow Insulation

Wood Shop Cold Water Line @ Hot Water Heater

2% Amosite Unknown/ Friable Unknown

NESHAPs

RACM

NA Remaining Interior/ Exterior and Roof Building Materials/ Areas

NA NA NA Not in Scope

TSI-Thermal System Insulation SF- Square Feet ND- None Detected NA- Not Applicable NESHAP– National Emissions Standard for Hazardous Air Pollutants Friable- Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry.

National Emission Standards for Hazardous Air Pollutants (NESHAP) Category Recommendations:

• Category I: Category I nonfriable ACM refers to asbestos-containing packing, gaskets, resilient floor coverings, and asphalt roofing products.

• Category II: Category II nonfriable ACM refers to any material that is not classified under Category I.

• Regulated Asbestos Containing Material (RACM): RACM refers to friable ACM or a Category I nonfriable ACM that has become friable or a Category I nonfriable ACM that has been or will be subjected to sanding, grinding, cutting or abrading or a Category II nonfriable ACM that has a high probability of becoming crumbled, pulverized or reduced to powder by the forces expected to act on the material in the course of renovation or demolition activities.

Project #14073 9 Asbestos Survey o Renovation Activities: There is no regulatory guideline that requires removal of RACM unless it will be disturbed during renovation or remodeling activities. If RACM is to be impacted or removed, the removal must be conducted by a Georgia Licensed Asbestos Abatement Contractor, with prior notification to the appropriate County and the State of Georgia agencies.

Project #14073 10 Asbestos Survey

6 LIMITATIONS

At the request of the Client, the scope of the survey was limited to interior and exterior building materials associated with the area of the SRS Athens GA South Building designated as the “Future Fire Lab” (FKA “Wood Shop”). Sampling of remaining interior and exterior areas of the South Building, and the roof was not included in the scope of the survey.

Destructive sampling procedures were not used to access the interior of wall cavities, fire doors, or above hard ceilings. If any materials are encountered during renovation activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non-ACM through laboratory analysis.

This report was prepared in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. This report was prepared for the exclusive use of the client and assigned agents and is not intended for any other purposes. Our report is based on the information available to us at the time of our investigation and limited in scope to the stated purpose and/or the area(s) inspected. Other conditions elsewhere in the site may differ from those in the inspected/ surveyed locations and such conditions are unknown, may change over time, and/or have not been considered. This report does not claim to identify all potential hazards and/or contaminants that may be present, nor does it imply any medical opinion on the relationship of potential health effects with any reported hazards and/ or contaminants. Our opinions are based on our findings and professional expertise, with no guaranty or warranty implied herein. The data obtained in this report does not establish the habitability of the site, nor does it determine if a building is safe or unsafe. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions, conclusions, and recommendations if necessary as warranted by the discovery of the additional information. AirQuest accepts no responsibility for interpretation of this report by others. Its contents shall not be used or relied upon by other parties without prior written authorization by AirQuest.

Appendix I Certifications

Appendix II Laboratory Report and Chain of Custody Record

EMSL Analytical, Inc.

2205 Corporate Plaza Parkway SE, Suite 200 Smyrna, GA 30080

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

071807124EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Attention: Phone:AirQuest Environmental, Inc. (954) 792-4549

Fax:6851 Southwest 45th Street (954) 792-2221

Received Date:Fort Lauderdale, FL 33314 10/10/2018 4:00 PM

Analysis Date: 10/11/2018

Collected Date: 10/10/2018

Project: Dorsey Engineering Inc.

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

14073-01-Wrap

071807124-0001

None DetectedNon-fibrous (Other)60%Cellulose40%White

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-01-Insulation

071807124-0001A

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-02-Wrap

071807124-0002

None DetectedNon-fibrous (Other)60%Cellulose40%Tan

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-02-Mastic

071807124-0002A

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-02-Insulation

071807124-0002B

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-03-Wrap

071807124-0003

None DetectedNon-fibrous (Other)60%Cellulose40%Gray

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-03-Insulation 1

071807124-0003A

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-03-Insulation 2

071807124-0003B

<1% AmositeNon-fibrous (Other)60%Min. Wool40%Gray

Fibrous

Homogeneous

TSI 4" Elbows/South

Area

HA: 01

14073-04-Wrap

071807124-0004

None DetectedNon-fibrous (Other)60%Cellulose40%Tan

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-04-Mastic

071807124-0004A

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-04-Insulation

071807124-0004B

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-05-Wrap

071807124-0005

None DetectedNon-fibrous (Other)60%Cellulose40%Tan

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

Report amended: 10/15/2018 14:17:41 Replaces initial report from: 10/11/2018 10:21:48 Reason Code: Data Entry-Change to Project

Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 10/15/2018 2:18 PM

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

071807124EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

14073-05-Insulation

071807124-0005A

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-06-Wrap

071807124-0006

None DetectedNon-fibrous (Other)60%Cellulose40%Tan

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-06-Insulation

071807124-0006A

None DetectedNon-fibrous (Other)10%Glass90%Yellow

Fibrous

Homogeneous

TSI 12" Pipe/NW

Area

HA: 02

14073-07-Cove Base

071807124-0007

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" Black VFC/SE

Area

HA: 03

14073-07-Mastic

071807124-0007A

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

4" Black VFC/SE

Area

HA: 03

14073-08-Cove Base

071807124-0008

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" Black VFC/SE

Area

HA: 03

14073-08-Mastic

071807124-0008A

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

4" Black VFC/SE

Area

HA: 03

14073-09

071807124-0009

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Misc. Concrete

Pads/South Area

HA: 04

14073-10

071807124-0010

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Misc. Concrete

Pads/NW Area

HA: 04

14073-11

071807124-0011

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Brick Mortar/NE Area

HA: 05

14073-12

071807124-0012

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Brick Mortar/SE Area

HA: 05

Report amended: 10/15/2018 14:17:41 Replaces initial report from: 10/11/2018 10:21:48 Reason Code: Data Entry-Change to Project

Page 2 of 3ASB_PLM_0008_0001 - 1.78 Printed: 10/15/2018 2:18 PM

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

071807124EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Analyst(s)

Violedah Richardson (23) Amber Baynes, Asbestos Lab Supervisor or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc Smyrna, GA NVLAP Lab Code 101048-1

Report amended: 10/15/2018 14:17:41 Replaces initial report from: 10/11/2018 10:21:48 Reason Code: Data Entry-Change to Project

Page 3 of 3ASB_PLM_0008_0001 - 1.78 Printed: 10/15/2018 2:18 PM

O r d e r I D

P a g e

O f

Appendix III Photographs

US Forest Service Southern

Research Station

Athens Fire Lab

320 Green Street

Athens, Georgia 30602

Project #14073

October 10, 2018

Project #14073 Page 1 of 1

Exterior

HA 1- TSI 4” Elbows with Wrap, Insulation and

Mastic (insulation is previously identified ACM))

HA 2- TSI 12” Pipe with Wrap, Mastic and

Insulation

HA 3- Black 4” Vinyl Floor Cove and Mastic

HA 4- Concrete Pads

HA 5- Brick Mortar

Appendix IV Provided Diagram(s)

Appendix V Provided 2010 Asbestos Survey Report jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight jasonleeanderson Highlight