This document contains questions and answers related to federal solicitation number 12445521B0010 for campground improvements at Lake Sherwood Campground within the Monongahela National Forest. Work will include demolition of existing buildings and structures such as vault toilets, water fountains, sheds, a lift station basin, bathhouse, and shower building. New construction will comprise two vault toilets, one bath house building, and one shower building. The estimated value of the project ranges from $500,000 to $1,000,000. Existing buildings are wood frame with concrete floors or voiles. Showers have concrete floors and restrooms concrete voiles. RV pedestals will provide power only. The camper parking area and trees have been prepared for the new construction. The depth of the existing lift station basin is approximately 12 feet. No West Virginia builders license is required. The solicitation is issued by the US Department of Agriculture Forest Service.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 5 – Lake Sherwood Questions and Answers IFB # 12445521B0010, Lake Sherwood Campground Bldg Improvement

1. Are the existing Bldgs to be demoed wood construction or concrete?

ANSWER = The Buildings are wood frame with either concrete floors or concrete voiles. Showers are concrete floors and restrooms are concrete voiles.

1. Is there a spec for the RV Pedestal to be installed on sheet 14? Is it power only or does in need to include a water hook-up as well?

ANSWER = For Power only (UL Listed 50, 30, 20 amp Direct Burial RV Pedestal Electrical Box)

· Suitable for campground, RV and temporary service

· UL Listed

· NEMA type 3R rainproof enclosure for outdoor use

· One piece enclosures constructed from 16-ga. G90 galvanized steel

· All surfaces have electrostatic gray powder coated finish

· 120/240 volt single phase, 125 Amp

· Commercial quality receptacles, Pass & Seymour brand

· 50 Amp (14-50R), 30 Amp (TT30R) and 20 Amp GFCI Weather Resistant Receptacle (5-20R2GFI)

· Loop feed lugs on all pedestals up to 350 MCM wire. Our CA380 lug in our loop feed lug assembly is 600 volts. 250 amps for aluminum. 310 amps for copper.

· Tin plated copper stabs standard

· All units factory wired

· Square D HomeLine breakers

· All units standard with hub openings, closure plate included

· For overhead or underground connection

· Pedestals: Loop feed lugs provide for #6 wire thru 350 MCM wire

· Tamper proof seals standard on pedestals and meter units

· All 9" boxes are 9.125" wide

· Direct burial, Earth burial mounted pedestal

1. Is the camper Parking area shown on sheet 14 already there?

ANSWER = Yes there is a camping spur already install at this site.

1. Will there be a requirement to remove any trees to accommodate for the crane and setting of the new Bldgs?

ANSWER = The trees have been cut down and removed from site. but grubbing and removal of the stumps is a must still.

1. Do you have a depth of the current lift station basin? According to the contract drawings it is 48” diameter, however I don’t see a depth anywhere?

ANSWER = Existing lift station basin depth is approximately 12’.

1. Is a WV Builders License a requirement for this project?

ANSWER = There is no requirement for a WV Builders License.

1. What is the estimated value of this project?

ANSWER = The magnitude of this project is found on Page 6, Para. C.3. of the IFB: between $500,000 and $1,000,000.