The customer requirements specify the refractometer must operate within a temperature range of 32 to 131°F (0 to 55°C), ambient temperature of 33.8 to 113°F (1 to 45°C), and fluid pressure of 60 to 110 psig (4.1 to 7.6 bar). The refractometer must measure Brix values from 5 to 100 with a resolution of 0.1 and accuracy of ±0.25. The refractometer should have digital (RS232) and analog (4-20mA, 0-10V) communication options, and must be compatible with Viton, Fluorosilicone, Kalrez, and Silicon seals.
The related federal contract opportunity is a Request for Quotation (RFQ) for an "Industrial Inline Process Refractometer" under NAICS code 334513. This is a total small business set-aside for the MISCO VIP2 brand refractometer, with a requirement for a NIST (Standard) Certificate and shipping. The solicitation is being issued by the Department of Agriculture Forest Service.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_12441924Q0031.pdf | ||
| FAR 13 Single Source or Brand Name Justification.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Customer Requirements Inline/Process Refractometer
32 to 131 °F (0 to 55 °C)Ambient Temperature
33.8 to 113 °F (1 to 45 °C)Fluid Temperature
60 to 110 psig (4.1 to 7.6 bar)Fluid Pressure
12 to 24 VDCPower Requirement
Customer Requirements
Requirements
United States Forest ServiceCustomer:
Scales
Scale Fluid Name Sucrose BRIX 5 to 100 °C0 to 85 0.1 0.25003 B 01
Unit of Measure
IRIS+ MVP & VIP2
0 to 52°C (32 to 125 °F)
0 to 52°C (32 to 125 °F)
0 to 50 psi (0 to 3.4 Bar)
5 to 24 VDC
-40 to 70°C (-40 to 158°F)
-20 to 100 °C (-4 to 212 °F)
0 to 20.68 Bar (0 to 300 psi)
5 to 24 VDC (3 VDC Optional)
IRIS
5 to 40 °C (41 to 104 °F)
5 to 40 °C (41 to 104 °F)
0 to 36 psi (0 to 2.5 Bar)
12 to 24 VDC
Standard Limit Reference
Quote #:
Include Certification
Range Resolution ATC Range
Seal Reference
Viton - Fluorocarbon: -25° to +230°C (-13° to +446°F) Fluorosilicone: -59° to +200°C (-75° to +400°F)
Kalrez: -25° to 315 °C (-13 to +600°F) Silicon: -65° to 204 °C (-85 to +400°F)
Notes
2/8/2024Date:
Note: Custom sensors may exceed standard limits.
ATC = Automatic Temeprature Correction
Material Compatibility
Seals Materials BondedOptics Viton (FKM)Enclosure
N/AFlow-Thru Adapter N/AInternal PTC Fitting
Buna-N / Nitrile (NBR)Tri-Clamp Seal
SapphireMeasuring Surface
N/AFlow-Thru Adapter
316L SS - PassivatedSensor Head 316L SS - PassivatedSensor Body
N/AInternal PTC Fittings N/AAttachable PTC Fittings
WARNING: make certain that these materials are compatible with your process and fluids.
PTC = Push-to-Connect
DRevision
VIP2-i-308P/N:
Precision (+/-)
MISCO Form QMS-0323(a)
#124983DOC #Model #
VIP2-i
Communication Options Digital - RS232 Analog - 4 to 20 mA Analog - 0 to 10 Volt
Other
-X - Dentoes Custom Sensor
File details come from the government source that posted it. Updated .