RFQ 12441923Q0014 (Blanchard Springs Booster Pumps and Control Panel)-AMEND 0002 (SAM).pdf
PDF 558 KB Posted
- Solicitation number
- 12441923Q0014
- Issued by
-
Department of Agriculture Forest Service
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
12441923Q0014 x x copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
WASHINGTON DC 20250-0001
1400 INDEPENDENCE AVE SW MS-1138
SPOC EAST
USDA FOREST SERVICE
60846601/19/20230002
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
01/18/2023
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
The purpose of this Solicitation Amendment is to:
1) Incorporate the Notes and Questions and Answers (Q&As) that resulted from the Site
Visit, which occurred on 18 January 2023.
2) All other terms and conditions remain unchanged.
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
MARK J. MILLER
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
Type text here 1/19/2023
18 January 2023
Blanchard Springs Booster Pumps and Control Pre Bid Site Visit.
Danny Sims, COR
The meeting started at 10am at the Blanchard Springs Visitor Center. The Covid Community levels for the county were high this week, which required everyone one onsite to wear masks.
Contractors signed in, then I gave a brief description of the project and explained the function of the booster pumps. Two large restrooms on the main floor and two smaller restrooms upstairs and a commercial washer and sinks in the lower/basement area.
Then the meeting moved to the building that houses the current booster pumps. The contractors came in and took photos and asked questions.
Q1. Does the pressure switch that controls the Peabody propane emergency pump stay since it was in line to the pressure tank? A. The Peabody pump, controls, plumbing and all associated electrical components will need to be removed from the system.
Q2. Does all the PVC piping get replaced? A. Yes, when the Peabody pump is removed from the system it changes the configuration enough that all the PVC needs replaced.
Q3. Do the controls for the pump motors have to be mounted to the pumps? A. No, it was discussed that there are additional options for motors and drives if that was not a requirement.
Remote mounting of controls is acceptable.
Q4. How many gallons per minute are we requesting? A. A nominal flow of 3 to 125 GPMs
Q5. Do the pumps run off the generator and does the pressure switch turn on the generator? A.
The propane generator is the backup power source for the pumps, and the pressure switch does not control the generator. If commercial power goes out the generator runs until power is restored.
Q6. Can the pumps be controlled remotely? A. No, but the Control Panel on the new system has a requirement for Building Management Systems Integration: BACnet MS/TP, BACnet IP, Ethernet IP, Modbus RTU, Modbus TCP,LON.
Q7. I was asked where to find the bid sheets/directions? A. I gave the Solicitation # and explained how to find it in SAMs.
Q8. Do all the valves get replaced? A. The main inlet and outlet valves in the building do not get replaced.
Q9. Is this a mandatory bid? A. I told him that he did not have to place a bid.
The meeting concluded at the Visitor Center at 11:15.