2023.10.12 Mackinaw CG - Unit B_Draft.pdf
PDF 2 MB Posted
- Solicitation number
- 1240LT24R0004
- Issued by
-
Department of Agriculture Forest Service
About this file
This set of construction drawings and related federal contract opportunity are for restoration work at the Mackinaw Campground shower and restroom building in the Fishlake National Forest. The drawings include floor plans, detail views, and elevations depicting repairs and replacements needed at the building, such as replacing the cedar shake roof, installing new door hardware and signage, repairing plumbing fixtures, and painting interior walls and trim. The related solicitation is for a special notice from the Department of Agriculture Forest Service seeking bids for phase two of the GAOA 4CV Mackinaw CG-Fish Lake Basin Rec Area DM Reduce project, which involves restoring the shower and restroom building in line with the work specified in the construction drawings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
101 102 103
106 107 108
TOILET RM. TOILET RM. TOILET RM. ACCESSIBLE
TOILET RM.
UTILITY
SHOWER RM. SHOWER RM. SHOWER RM.
ACCESSIBLE
SHOWER RM.
ELECTRIC PANEL
INSTANT W.H.
09 09 09 09
121212
12 12 12
05 06
United States Department of Agriculture Forest Service
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
R-4
INTERMOUNTAIN REGION
R. ALLEN
R. ALLEN
R. ANDERSON
FLOOR PLAN
FISHLAKE NATIONAL
FOREST
A1.01
RESTORATION OF SHOWER AND
RESTROOM BUILDING B
MACINAW CAMP
GROUND
1/4" = 1'-0"1 FLOOR PLAN
PLAN KEYED NOTES:
REPLACE CEDAR SHAKE ROOF, SEE ELEVATIONS.
PROVIDE AND INSTALL DEADBOLT TO REPLACE MISSING
HARDWARE AT EXISTING DOOR. SEE DETAIL VIEW 6 ON
SHEET A1.02
DEMO AND REMOVE BROKEN SPRING TYPE DOOR
CLOSER AND REPLACE WITH SIMILAR TYPE. SEE DETAIL
VIEW 7 ON SHEET A1.02
PROVIDE AND INSTALL DOOR SIGNAGE TO REPLACE
MISSING SIGN, TO MATCH OTHERS AS CLOSELY AS
POSSIBLE. SEE DETAIL VIEW 6 ON A1.02
REPAIR LOOSE DOOR LATCH AND DEADBOLT, CONSULT
COR IF IT CAN'T BE EASILY TIGHTENED.
PROVIDE AND INSTALL MISSING DOOR HARDWARE
(SCREW). SEE DETAIL VIEW 7 ON A1.02
DEMO AND REMOVE BROKEN WATER FOUNTAIN.
PROVIDE AND INSTALL HIGH / LOW TYPE WATER
FOUNTAIN.
VERIFY IN FIELD THAT NEW UNIT WILL FIT BEFORE
ORDERING. SEE DETAIL VIEW 2 ON A1.02
SECURE LOOSE CEILING TRIM FRAMING. SEE DETAIL
VIEW 4 ON SHEET A1.02
PROVIDE AND INSTALL LAVATORY DRAIN WRAP TO WALL
MOUNTED SINK. SEE DETAIL VIEW 3 ON SHEET A1.02
ADJUST AND SEAL SHOWER CONTROL PANEL TO
ELIMINATE GAP. SEE DETAIL VIEW 1 ON SHEET A1.02
ADJUST LAVATORY FAUCET TO ELIMINATE DRIP,
CONSULT COR IF NOT POSSIBLE.
PREP AND PAINT CEILING AND WALL PANELS AND TRIM
ABOVE TILED AREA. SEE DETAIL VIEW 6 ON SHEET A1.02
SHOWER ROOM 106 HAS BEEN LOCKED AND OUT OF
USE FOR AN UNKNOWN PERIOD. GAIN ACCESS TO
ROOM AND DETERMINE NEEDED REPAIRS.
(NOTE TO CHANGE AFTER SITE VISIT ON 10/18/2023)
UNIT B SAT VIEW2
NOT FOR CONSTUCTION 75% DRAFT SET
United States Department of Agriculture Forest Service
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
R-4
INTERMOUNTAIN REGION
R. ALLEN
R. ALLEN
R. ANDERSON
DETAIL VIEWS
FISHLAKE NATIONAL
FOREST
A1.02
RESTORATION OF SHOWER AND
RESTROOM BUILDING B
MACINAW CAMP
GROUND
GAP1 WATER FOUNTAIN2
CEILING TRIM4
LAVATORY3
TYPICAL CEILING5
MISSING DEADBOLT6 BROKEN CLOSER7 MISSING SCREW7 BROKEN MACHINE8
?? IS THIS MACHINE ACTUALLY BROKEN ??
T.O. SLAB
0' - 0"
T.O. ROOF
14' - 1"
B.O. ROOF
7' - 8"
T.O. SLAB
0' - 0"
T.O. ROOF
14' - 1"
B.O. ROOF
7' - 8"
United States Department of Agriculture Forest Service
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
R-4
INTERMOUNTAIN REGION
R. ALLEN
R. ALLEN
R. ANDERSON
NORTH AND EAST
ELEVATIONS
FISHLAKE NATIONAL
FOREST
A2.01
RESTORATION OF SHOWER AND
RESTROOM BUILDING B
MACINAW CAMP
GROUND
3/16" = 1'-0"1 NORTH ELEVATION
3/16" = 1'-0"2 EAST ELEVATION
ELEVATION KEYED NOTES:
DEMO AND REMOVE ALL CEDAR SHAKE AND ROOFING
FELT FROM ENTIRE ROOF. STRIP ROOF DOWN TO
SHEATHING. REPLACE ANY SHEATHING WITH MOISTURE
OR ROT DAMAGE (ESTIMATE 5% OF ROOFING SF).
PROVIDED AND INSTALL INCE AND WATER SHIELD AND
CEDAR SHAKE TO ENTIRE ROOF PER SPECIFICATIONS.
SCRAPE AND PREP WOOD FACIA, SOFFIT, WOOD SIDING,
AND TRIM. STAIN ALL WOOD SURFACES, COLOR TO
MATCH EXISTING AS CLOSELY AS POSSIBLE. SEE
SPECIFICATIONS.
APPROX LOCATIONS OF ROOF PENETRATIONS. DEMO
AND REMOVE FLASHING, PROVIDE AND INSTALL NEW
FLASHING AND WATERPROOF PER NRCA ROOF MANUAL
AND STANDARDS.
CONFIRM THAT CHANGE MACHINE IS FUNCTIONING
CORRECTLY.
NOTE: CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS, SIZES, AND QUANTITIES.
T.O. SLAB
0' - 0"
T.O. ROOF
14' - 1"
B.O. ROOF
7' - 8"
02 02
0303 03
T.O. SLAB
0' - 0"
T.O. ROOF
14' - 1"
B.O. ROOF
7' - 8"
03 03
United States Department of Agriculture Forest Service
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
R-4
INTERMOUNTAIN REGION
R. ALLEN
R. ALLEN
R. ANDERSON
SOUTH AND WEST
ELEVATIONS
FISHLAKE NATIONAL
FOREST
A2.02
RESTORATION OF SHOWER AND
RESTROOM BUILDING B
MACINAW CAMP
GROUND3/16" = 1'-0"1 SOUTH ELEVATION
3/16" = 1'-0"2 WEST ELEVATION
NOT FOR CONSTUCTION 75% DRAFT SET
NOT FOR CONSTUCTION 75% DRAFT SET
ELEVATION KEYED NOTES:
DEMO AND REMOVE ALL CEDAR SHAKE AND ROOFING
FELT FROM ENTIRE ROOF. STRIP ROOF DOWN TO
SHEATHING. REPLACE ANY SHEATHING WITH MOISTURE
OR ROT DAMAGE (ESTIMATE 5% OF ROOFING SF).
PROVIDED AND INSTALL ICE AND WATER SHIELD AND
CEDAR SHAKE TO ENTIRE ROOF PER SPECIFICATIONS.
SCRAPE AND PREP WOOD FACIA, SOFFIT, WOOD SIDING,
AND TRIM. STAIN ALL WOOD SURFACES, COLOR TO
MATCH EXISTING AS CLOSELY AS POSSIBLE. SEE
SPECIFICATIONS.
APPROX LOCATIONS OF ROOF PENETRATIONS. DEMO
AND REMOVE FLASHING, PROVIDE AND INSTALL NEW
FLASHING AND WATERPROOF PER NRCA ROOF MANUAL
AND STANDARDS.
NOTE: CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS, SIZES, AND QUANTITIES.
| Sheets |
| A1.01 - FLOOR PLAN |
| A1.02 - DETAIL VIEWS |
| A2.01 - NORTH AND EAST ELEVATIONS |
| A2.02 - SOUTH AND WEST ELEVATIONS |
File details come from the government source that posted it. Updated .