FOREST LOCATION
VICINITY MAP
TRAVEL DIRECTIONS:
SHEET OF
UNITED STATES DEPARTMENT OF AGRICULTURE
FOREST SERVICE
DAN MOLLER OUTHOUSE REPLACEMENT
THE DAN MOLLER RECREATION CABIN IS LOCATED ON DOUGLAS ISLAND IN JUNEAU, ALASKA. THE
TRAILHEAD IS LOCATED IN THE BLUEBERRY HILLS SUBDIVISION AND THE TRAIL CONTINUES SOUTH OF
THE TRAILHEAD 3 MILES TO THE SITE OF THE CABIN. THE LATITUDE AND LONGITUDE OF THE CABIN
ARE APPROXIMATELY 58.262214° N, -134.459672° W.
PROJECT LOCATION
AUGUST 21, 2020 100% CONSTRUCTION DOCUMENTS
RECOMMENDED BY:
APPROVED:
DIRECTOR OF ENGINEERING
DATE
FOREST SUPERVISOR
DATE
8/2 1/2
0 1 3:
L
PR
IN
GL
E
J:
\U
SF
-2
0-
D
AN
M
OL
LE
R
OU
TH
OU
SE
C D\
2 - C
AD
\S
HE
ET
S-
DA
N
MO
LL
ER
C
AB
IN
.D
W G;
ALASKA
(R-10) ALASKA REGION
TONGASS NATIONAL FOREST
JUNEAU RANGER DISTRICT
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G1.0 COVER SHEET
S1.0 GENERAL NOTES
S2.0
EXISTING CONDITIONS, SURVEY AND
DEMOLITION PLAN
S2.1 GENERAL SITE PLAN
S2.2 TYPICAL FOUNDATION DETAILS
S2.3 TYPICAL FRAMING DETAILS
S3.0
WALKWAY FRAMING PLAN, SECTIONS AND
DETAILS
S3.1 WALKWAY FRAMING SECTIONS AND DETAILS
S4.0 OUTHOUSE FRAMING PLANS
S4.1 OUTHOUSE FRAMING SECTIONS
S4.2 OUTHOUSE FRAMING SECTIONS AND DETAILS
S4.3 OUTHOUSE FRAMING SECTIONS AND DETAILS
S5.0
WALKWAY ROOF FRAMING PLAN, SECTION,
AND DETAILS
S5.1 WALKWAY ROOF DETAILS
S6.0 OUTHOUSE TANK PLANS AND DETAILS
L7.0 INTERIOR OUTHOUSE LAYOUT
REVIEWED BY:
DISTRICT RANGER DATE
FOREST ENGINEERING STAFF OFFICER DATE
FOREST RECREATION STAFF OFFICER
DATE
DIRECTOR OF RECREATION DATE
DOUGLAS ISLAND
DOUGLAS
JUNEAU
lwild02 Line lwild02 Line lwild02 Line lwild02 Typewritten Text
ECCQ66
lwild02 Typewritten Text
OPPOSITE SIDE SIMILAR.
5"
10"
18"
Grab Bar A
Tissue Dispenser
Transfer
Side
Grab Bar B
Waterless Toilet Riser
Grab Bar A
8"
L
C
Waterless Toilet Riser
Finished Floor
Transfer
Side
Waterless Toilet Riser
Tissue Dispenser
Side Wall Elevation Rear Wall ElevationPlan View
L
C
Finished Floor
5"
Grab Bar B
Tissue Dispenser
Rear Wall
L
C
1'-6"
S i d e
W a l l
16"Ø O.D. Type 1 PVC Pipe
2x2 spacer (TYP)
Type 1 PVC Flange for 16"Ø pipe
2x8 joist
Waterless Toilet Riser
16"Ø O.D. Type 1 PVC Pipe
2x4 blocking (TYP)
2x8 joist
Type 1 PVC Flange for 16"Ø pipe
" x 3" SS lag bolt w/ fender washer (TYP)
Section A - Front Section Section B - Transverse Section
B
Outhouse Tank
F i e l d
V e r i f y
Finished Floor
Glue flange to pipe, verify location prior to glueing
(4) #10 x 2
" wood screw (TYP)
2x2 spacer (TYP)
L
C
L
C
Top of PVC pipe to be tight against top of toilet riser.
Pipe opening to be aligned with toilet opening
Notes:
1. Smooth all edges of PVC pipe prior to installation.
16"Ø O.D. Type 1 PVC Pipe
Type 1 PVC flange
Waterless Toilet Riser
2x4 blocking, attached to joist w/
#10 x 2
" wood screw (TYP)
Glue flange to pipe, verify location prior to gluing
2x8 joist
Outhouse Tank
Section C - Side Section
1'-6"
(TYP)
16"Ø O.D. PVC Pipe
(TYP)
Waterless Toilet Riser
(TYP)
Outhouse Tank (TYP), see structural
9"
Outhouse Tank (TYP), see structural
Section APlan View Section B
A
B
16"Ø O.D. PVC Pipe
Waterless Toilet Riser
Outhouse Tank, see structural
Rear Deck
Finished Floor
16"Ø O.D. PVC Pipe (TYP)
L7.0
Waterless Toilet Riser
INTERIOR
OUTHOUSE
LAYOUT
L7.0
SCALE: NTS @22x34
Toilet & Grab Bar Layout2
L7.0
SCALE: NTS @22x34
Waterless Toilet Riser3
L7.0
Waterless Toilet Riser:
Manufacturer: Acorn Engineering
Contact: Josh Richard, Suntoya Corporation, 509.534.1516
Product: Dura-Ware 2131 Series ADA Compliant with HSC Hinged Seat and Cover
Materials: Stainless Steel
Attachment: Per manufacturer's recommendations.
Tissue Dispenser:
Manufacturer: Murdock Manufacturing
Supplier: Josh Richard, Suntoya Corporation, 509.534.1516
Product: Tissue Dispenser Model# 1113
Materials: Stainless Steel
Attachment: Per manufacturer's recommendations.
Grab Bar A:
Manufacturer: Acorn Engineering
Contact: Josh Richard, Suntoya Corporation, 509.534.1516
Product: Shower-Ware Model# 1108-6
Materials: Stainless Steel
Attachment: Per manufacturer's recommendations.
Grab Bar B:
Manufacturer: Acorn Engineering
Contact: Josh Richard, Suntoya Corporation, 509.534.1516
Product: Shower-Ware Model# 1108-5
Materials: Stainless Steel
Attachment: Per manufacturer's recommendations.
Type 1 PVC Flange:
Manufacturer: Grainger Industrial Supply
Contact: 800-472-4643
Product: Flange Model# PVCF16
Fixtures
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
NO. REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
8/2 1/2
0 1 3:
L
PR
IN
GL
E
J:
\U
SF
-2
0-
D
AN
M
OL
LE
R
OU
TH
OU
SE
C D\
2 - C
AD
\S
HE
ET
S-
DA
N
MO
LL
ER
C
AB
IN
.D
W G;
DRAWING SHEET NO.
DATE
DAN MOLLER
OUTHOUSE
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU RANGER DISTRICT
08/21/2020
Corvus Design, Inc.
LP
CM
ALASKA REGION
USF-20-01
R10
49 TH
Christopher R. Mertl
No.10440
REGIST ERED PROFESSIONA L LA NDSCA PE A RCHITE
CT
08/21/2020
ST
ATE OF ALASKA
See structural for outhouse layout and detailing
1. All stainless steel joints to be welded construction.
2. All fixtures to have polished satin finish for exposed stainless steel surfaces
3. All fasteners to be stainless steel vandal-resistant
4. All fixtures to meet or exceed ANSI, UFAS, and
ADA requirements
Fixture Notes
SCALE: NTS @22x34
Outhouse Interior----
L7.0
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
| Sheets and Views |
| G1.0 COVER SHEET |
| Toilet & Grab Bar Layout - Plan View |
| Outhouse Pipe Section |
| Outhouse Interior |
| L7.0 INTERIOR OUTHOUSE LAYOUT |
| Toilet & Grab Bar Layout - Plan View |
| Outhouse Pipe Section |
| Outhouse Interior |
File details come from the government source that posted it. Updated .