Questions and Answers.docx

DOCX document 14 KB Posted

Attached to
Electrical Control Panel for Marel D166 Plucker Machine Federal contract opportunity
Solicitation number
12405B24Q0196
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery

About this file

This document is a set of Questions and Answers related to a solicitation for an Electrical Control Panel for a Marel D166 Plucker Machine (Solicitation ID: 12405B24Q0196). The key details are:

The solicitation is for an electrical control panel to power 12 motors that operate a D166 plucker machine. The required panel must have starters for the motors, lights to indicate when the motors are running, push buttons to turn the motors on/off, and an emergency stop. The panel must be rated NEMA 4 for a hot/humid environment with temperatures between 45-95°F. The provider of the control panel must be present during installation to advise the electrician on connecting the power. Quotes are due by 4:00 PM CST on May 29, 2024 and must be submitted to the Contract Specialist. Award will be made based on best value considering technical capability, past performance, and price.

View the file

Other files for this federal contract opportunity

Other files attached to Electrical Control Panel for Marel D166 Plucker Machine, newest first.
File Type Posted
Clauses FAC 2024-04 eff. 05-01-24 under $250k (Solicitation).pdf PDF
Specifications.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Marel D166 Plucker Machine (Solicitation ID: 12405B24Q0196) Questions and Answers

•What is the supply voltage? 208 V and 460 V.
•How are the motors being controlled (starters, VFDs, soft starts, etc.)? Starters.
•Do you need lights to show when motors are running, off, or faulted? Lights when running.
•Do you need push buttons to turn them on or off? Yes.
•Is a mushroom/estop needed? Yes.
•If using VFD, do you want a speed potentiometer to dial up or dial down the speed? No.
•What environment will the panel be installed in? What kind of NEMA rating would you like? NEMA = 4, Hot/Cool high Humidity. Protection against dripping and light splashing of hose directed water during clean and corrosion resistant.
•What is the ambient temperature? This is necessary to determine if temperature control is required for the panel (e.g., fans, air conditioning unit, etc.). 45 to 95F.
The provider of the starter control panel box must be present on the day of installation to advise the electrician on connecting the electrical power to the control panel and from the control panel to the 12 motors on the picker and to that all components are functions.