The document specifies that the required pump must accommodate a 4.625-inch impeller rotating at 3450 rpm, though no specific flow rate is provided in the requirements. The pump will handle water as the working fluid within a normal operating temperature range of 2–35°C, with typical operations at 4°C. The system has a maximum working pressure of 175 psi. The document includes a pump performance curve chart indicating the duty point for the existing dew chamber system, marked with a red indicator at approximately 55 US gpm and 75 feet of head. The performance curve displays multiple efficiency contours (ranging from approximately 40% to 55% efficiency) and includes horsepower requirement lines (1.5 hp, 2 hp, and 3 hp), providing comprehensive guidance for pump selection that meets the specified operating conditions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 2 – Q&A

• Required flow rate (GPM) o The 4.625” impeller needs to rotate at 3450 rpm, no flow rate info

• Available suction pressure / suction conditions o Working pressure max 175 psi

• Fluid being pumped o Water

• Normal operating temperature range o 2 – 35C, generally the operating temperature is 4C

• Any required pump performance curve or duty point for the existing dew chamber system o See below