ROAD RECONTOUR
NO SCALE
BEFORE RECONTOUR
SCATTER CLEARING SLASH ON FINISHED SLOPE. SLASH
CAN BE ANCHORED IN PLACE BY PARTIALLY BURYING TO
A MAXIMUM DEPTH OF 12".
EXCAVATE AND EMBANK ROAD FILL IN THE
REVERSE ORDER OF ROAD CONSTRUCTION.
PLACE THE MOST PRODUCTIVE SOIL ON THE
SURFACE OF THE RESTORED HILLSLOPE.
AFTER RECONTOUR
IDAHO PANHANDLE NATIONAL FORESTS
St. JOE RANGER DISTRICT
ROAD DECOMMISSIONING PAGE 3 OF 9
IDAHO PANHANDLE NATIONAL FORESTS
ROAD RECONTOUR
ROAD DECOMMISSIONING PAGE 4 OF 9
STREAM CHANNEL RESTORATION
EXCAVATION AREA
ROAD SURFACE
CONTOUR SIDE SLOPES TO MATCH
UNDISTURBED SIDE SLOPES UPSTREAM
AND DOWNSTREAM OF THE CHANNEL SITE.
RESTORE THE STREAM
CHANNEL TO MATCH THE
SAME WIDTH, DEPTH, AND
SLOPE AS THE STREAM
CHANNEL ABOVE THE
CHANNEL SITE.
ARMOR ROCK
IDAHO PANHANDLE NATIONAL FORESTS
St. JOE RANGER DISTRICT
ROAD DECOMMISSIONING
REMOVE DRAINAGE
STRUCTURE
ROAD SURFACE
STREAM CHANNEL RESTORATION
IDAHO PANHANDLE NATIONAL FORESTS
ROAD DECOMMISSIONING PAGE 6 OF 9
GRADIENT CONTROL
ROCK SIZE
A = LONGEST AXIS (LENGTH)
MINIMUM LENGTH= 16 INCHES.
B = INTERMEDIATE AXIS (WIDTH)
MINIMUM WIDTH= 16 INCHES.
C = SHORTEST AXIS (THICKNESS)
MINIMUM THICKNESS= 16 INCHES.
ARMOR ROCK
PERSPECTIVE VIEW
CROSS SECTION VIEW
CONSTRUCTION NOTES:
1. INSTALL GRADIENT CONTROL STRUCTURES IN THE RESTORED STREAM CHANNEL TO MATCH
GRADIENT BREAKS IN THE UNDISTURBED STREAM CHANNEL UPSTREAM OF THE CHANNEL SITE. LOGS, ROCK OR ROOTWADS CAN BE USED FOR GRADIENT CONTROL. INSTALL ROCKS AND ROOTWADS IN A
SLIGHTLY CONVEX SHAPE. LOGS SHALL HAVE A MINIMUM 10" SMALL END DIAMETER UNLESS OTHERWISE
APPROVED BY THE CONTRACTING OFFICER. ROCK SHALL MEET THE MINIMUM SIZE SHOWN ON THE
DRAWINGS AND BE DURABLE SO THAT IT REMAINS WHOLE AFTER INSTALLATION. ROCK CAN BE
CONSERVED FROM ADJACENT EXCAVATION. REMOVE ROOTWADS FROM A MINIMUM DIAMETER BREAST
HEIGHT (DBH) 16" TREE AND USE AS GRADIENT CONTROL.
2. ROCK CONSERVED FROM EXCAVATION CAN BE USED TO ARMOR THE STREAMBED. ARMOR ROCK
SIZE SHOULD MATCH THE THE DIMENSIONS OF THE ROCK IN THE ADJACENT UNDISTURBED CHANNEL.
3. INSTALL GRADIENT CONTROL STRUCTURES PERPENDICULAR TO STREAM FLOW WITH THE EXCEPTION
OF THE ROCK/LOG STRUCTURE.
4. KEY GRADIENT CONTROL STRUCTURES A MINIMUM OF 4" BELOW ORIGINAL STREAM GRADE AND BURY
HORIZONTALLY A MINIMUM OF 6 FEET INTO EACH STREAM BANK.
5. DITCH RELIEF CULVERTS DO NOT REQUIRE GRADIENT CONTROL STRUCTURES UNLESS THEY ARE IN A
NATURAL CHANNEL.
6. USE TREES AND LOGS STORED DURING THE CLEARING OPERATION AS HABITAT LOGS. INSTALL A
MINIMUM OF 6 LOGS WITH A MINIMUM LARGE END DIAMETER OF 10" AND A MINIMUM LENGTH OF 20'.
INSTALL HABITAT LOGS SO THEY CROSS THE STREAM CHANNEL AND PROVIDE SHADE AND COVER.
IDAHO PANHANDLE NATIONAL FORESTS
ROAD DECOMMISSIONING PAGE 7 OF 9
IDAHO PANHANDLE NATIONAL FORESTS
DECOMPACTION
ROAD DECOMMISSIONING PAGE 8 OF 9
EMBANK MATERIAL
CONSTRUCTION NOTES:
WATER BAR
NO SCALE
3' -6'
EXCAVATE MATERIAL
3' -6'
WATERBAR SPACING
ROAD GRADE (%) DISTANCE (FT.)
0-3.9 500
4-5.9 250
6-9.9 150
> 10 100
1. CONSERVE 6" - 18" ROCK ENCOUNTERED IN EXCAVATION AND PLACE AT THE OUTLET OF THE WATER
BAR TO ACT AS AN ENERGY DISSIPATOR, IF PRESENT.
2. SKEW WATER BAR 30
- 60
FROM ROAD CENTERLINE AND SLOPE THE DITCH FROM CUT BANK TO FILL
SLOPE TO FACILITATE DRAINAGE OF WATER OFF THE ROAD.
3. INTERCEPT DITCH WATER BY INCLUDING A DITCH BLOCK DURING CONSTRUCTION OF WATER BAR.
IDAHO PANHANDLE NATIONAL FORESTS
ROAD DECOMMISSIONING PAGE 9 OF 9