About this file
This solicitation requests quotations for the installation of two rolling steel bay doors at the Naval Surface Warfare Center Dahlgren Division. The requirements include removing two existing doors, one measuring 12'W X 10'H and one measuring 14'-0" by 18'-8", and installing a new 10' by 9'6" rolling steel service door with jackshaft operators and a 14' by 18'8" rolling steel service door with shaft operator. Both new doors must have a baked enamel gray finish, double angle bottom bar, exterior weather seal, and hood baffle. The solicitation will utilize simplified acquisition procedures and award a firm fixed price contract. Quotes are due by January 22, 2024 and award is anticipated by February 22, 2024. Historical pricing data and published pricing should be submitted with proposals. Award will be made to the lowest priced technically acceptable offer. The opportunity is set aside for small businesses and registered System for Award Management vendors.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SAM RFQ Rolling Door Questions.docx | DOCX document | |
| N0017824Q6679 Rollup Doors SF1449.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROLLUP BAY DOORS INSTALLATION
STATEMENT OF WORK (SOW)
1.0 BACKGROUND
The Naval Surface Warfare Center Dahlgren Division (NSWCDD), requires the removal and replacement of two (2) customized Rolling Steel Doors.
2.0 APPLICABLE DOCUMENTS
2.1 Occupational Safety and Health Administration (OSHA) Regulations;
2.2 Center for Disease Control (CDC) Guidelines; and
2.3 Original Equipment Manufacturer (OEM) Specifications.
3.0 REQUIREMENTS
3.1 The Contractor shall remove the current two (2) Rolling Steel Doors and provide disposal.
3.2 The Contractor shall provide and install two (2) customized Rolling Steel Doors that meet the following specifications:
3.2.1 First door: 10 foot by 9 foot, 6 inches Rolling Steel Service Door with jackshaft operators, baked enamel gray finish, double angle bottom bar, exterior weather seal, and hood baffle.
3.2.1.1 The jackshaft operators shall include ½ horsepower (HP) 208/230/460 Volts (V), 3 Phase (PH), one (1) open/close/stop wall station, brake, back up chain hoist, and electric safety edge.
3.2.2 Second door: 14 foot by 18 foot, 8 inches Rolling Steel Service Door with shaft operator, baked enamel gray finish, double angle bottom bar, exterior weather seal, and hood baffle.
3.2.2.1 The shaft operators shall include ½ HP, 208/230/460V, 3PH, one (1) open/close/stop wall station, brake, back up chain hoist, and electric safety edge.
3.3 The Contractor shall provide all necessary equipment for installation.
3.4 The Contractor shall assemble the doors and ensure they are operating in accordance with (IAW) OEM specifications.
3.5 The Contractor personnel shall wear personal protective equipment IAW OSHA regulations and CDC guidelines throughout the project.
3.6 The Contractor shall protect Government property from damage or disfigurement.
3.7 The Contractor shall keep all supplies, equipment, and tools out of traffic lanes or other areas where they might create a hazard.
3.8 The contractor shall perform all work during normal working hours, Monday through Friday, 0800 – 1600.
3.9 At the end of each work period, the Contractor shall secure all supplies, equipment and tools.
File details come from the government source that posted it. Updated .