11B5092031_DRAW A.pdf
PDF 116 KB Posted
- Attached to
- Bolts, Blind Structural Federal contract opportunity
- Solicitation number
- W519TC-24-Q-2099
About this file
This document contains a vendor item control drawing and related federal contract opportunity solicitation. The vendor item control drawing provides specifications for two blind structural bolt products, including style, material, finish, installation requirements, and certification information. The related federal contract opportunity solicitation is for the procurement of blind structural bolts. The solicitation was issued by the Department of the Army Materiel Command Contracting Command Rock Island Arsenal and provides no further details on response dates, award dates, pricing terms, or set asides.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 24-Q-2099 Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
.810
1.00±.13
NOTES
APPLICABLE STANDARDS/SPECIFICATIONS:1.
ASME Y14.100-2017A.
ASME Y14.5-2009B.
IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF 2.
SUPPLY HEREON IS NOT TO BE CONSTRUED AS A
GUARANTEE OF PRESENTOR CONTINUED
AVAILABILITY AS A SOURCE OF SUPPLY FOR THE
ITEM DESCRIBED ON THE DRAWING.
VENDOR PART NUMBER(S) ARE FOR REFERENCE 3.
ONLY. DRAWING SPECIFICATIONS AND
DIMENSIONAL REQUIREMENTS SUPERCEDE VENDOR
PART NUMBER(S) AND/OR CATALOG CALLOUTS.
SUGGESTED SOURCE OF SUPPLY
PART
NUMBER
VENDOR DATA
NAME & ADDRESS CAGE
CODE
VENDOR
PART NO. DESCRIPTION
11B5092031
KEE SAFETY, INC
100 STRADTMAN ST
BUFFALO, NY 14206
800-851-5181
0EF50 SEE TABLE LNA SOLUTIONS, ICC APPROVED
BOXBOLT (TYPE C), 1/2"
SPECIFICATIONS
STYLE STRUCTURAL BLIND BOLT
MATERIAL MILD STEEL
FINISH HOT DIP GALVANIZED
SHOULDER DIMENSION 1.00 +/- .13
INSTALLATION HOLE DIAMETER .81" +/- .06"
NOMINAL INSTALLATION TORQUE 60 FT LB
MIN ALLOWABLE BOLT SPACING
BETWEEN HOLE CENTERS 3.00" OR LESS
MIN ALLOWABLE MATERIAL EDGE
DISTANCE TO HOLE CENTERS 1.25" OR LESS
MIN RATED LRFD SEISMIC SHEAR-
BEARING STRENGTH 6,800 LBF
MIN RATED LRFD SEISMIC TENSION
STRENGTH 4,700 LBF
CERTIFICATION
MEET INTERNATIONAL CODE COUNCIL
EVALUATION SERVICE (ICC-ES)
ACCEPTANCE CRITERIA FOR
EXPANSION BOLTS IN STRUCTURAL
STEEL CONNECTIONS (AC437)
MEETING 2015 INTERNATIONAL
BUILDING CODE (IBC)
REVISIONS
LTR NOR NUMBER DATE APPROVED
- 738-0306-015
BLIND STRUCTURAL BOLT SCHEDULE
PART
NUMBER NOMENCLATURE VENDOR
PART NO.
MIN
CLAMP RANGE NEXT ASSY
11B5092031-1 BLIND STRUCTURAL BOLT, SHORT BQ1GAL12C 1/2" - 15/16" 11B5000001
11B5100001
11B5092031-2 BLIND STRUCTURAL BOLT, LONG BQ3GAL12C 1-1/2" - 2-11/18" 11B5000001
DWG NO.
CONTRACT NO.
5B5M3
DAI
C
SIZE
3 PLACE DECIMALS ±
2 PLACE DECIMALS ± .03
SHEETSCALE
DRAWING APPROVAL
DESIGN APPROVAL
SUBMITTED
CHECKERDRAWN BY
(YR-MO-DA)
ORIGINAL DATE
MATERIAL
TOLERANCES ON:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
EQUIPMENT CODE NO.
NEXT ASSY
4 3 2 1
4 3 2 1
D
C
B
A
D
C
B
A
ANGLES ± BLIND STRUCTURAL BOLT
11B5092031 2:1
R. McCLAIN
SEE SPECIFICATIONS
TABLE
SEE TABLE
ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299
U.S. ARMY COMBAT CAPABILITIES DEVELOPMENT COMMAND
CHEMICAL BIOLOGICAL CENTER
VENDOR ITEM CONTROL DRAWING
FRACTIONS ±
DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE;
DISTRIBUTION IS UNLIMITED.
C. HANEY
P. SCHLUE
Rev: -
2023-10-30
R. McCLAIN
R. McCLAIN
File details come from the government source that posted it. Updated .