11B5092031_DRAW A.pdf

PDF 116 KB Posted

Attached to
Bolts, Blind Structural Federal contract opportunity
Solicitation number
W519TC-24-Q-2099
Issued by
Department of the Army Materiel Command Contracting Command Rock Island Arsenal

About this file

This document contains a vendor item control drawing and related federal contract opportunity solicitation. The vendor item control drawing provides specifications for two blind structural bolt products, including style, material, finish, installation requirements, and certification information. The related federal contract opportunity solicitation is for the procurement of blind structural bolts. The solicitation was issued by the Department of the Army Materiel Command Contracting Command Rock Island Arsenal and provides no further details on response dates, award dates, pricing terms, or set asides.

View the file

Other files for this federal contract opportunity

Other files attached to Bolts, Blind Structural, newest first.
File Type Posted
24-Q-2099 Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

.810

1.00±.13

NOTES

APPLICABLE STANDARDS/SPECIFICATIONS:1.

ASME Y14.100-2017A.

ASME Y14.5-2009B.

IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF 2.

SUPPLY HEREON IS NOT TO BE CONSTRUED AS A

GUARANTEE OF PRESENTOR CONTINUED

AVAILABILITY AS A SOURCE OF SUPPLY FOR THE

ITEM DESCRIBED ON THE DRAWING.

VENDOR PART NUMBER(S) ARE FOR REFERENCE 3.

ONLY. DRAWING SPECIFICATIONS AND

DIMENSIONAL REQUIREMENTS SUPERCEDE VENDOR

PART NUMBER(S) AND/OR CATALOG CALLOUTS.

SUGGESTED SOURCE OF SUPPLY

PART

NUMBER

VENDOR DATA

NAME & ADDRESS CAGE

CODE

VENDOR

PART NO. DESCRIPTION

11B5092031

KEE SAFETY, INC

100 STRADTMAN ST

BUFFALO, NY 14206

800-851-5181

0EF50 SEE TABLE LNA SOLUTIONS, ICC APPROVED

BOXBOLT (TYPE C), 1/2"

SPECIFICATIONS

STYLE STRUCTURAL BLIND BOLT

MATERIAL MILD STEEL

FINISH HOT DIP GALVANIZED

SHOULDER DIMENSION 1.00 +/- .13

INSTALLATION HOLE DIAMETER .81" +/- .06"

NOMINAL INSTALLATION TORQUE 60 FT LB

MIN ALLOWABLE BOLT SPACING

BETWEEN HOLE CENTERS 3.00" OR LESS

MIN ALLOWABLE MATERIAL EDGE

DISTANCE TO HOLE CENTERS 1.25" OR LESS

MIN RATED LRFD SEISMIC SHEAR-

BEARING STRENGTH 6,800 LBF

MIN RATED LRFD SEISMIC TENSION

STRENGTH 4,700 LBF

CERTIFICATION

MEET INTERNATIONAL CODE COUNCIL

EVALUATION SERVICE (ICC-ES)

ACCEPTANCE CRITERIA FOR

EXPANSION BOLTS IN STRUCTURAL

STEEL CONNECTIONS (AC437)

MEETING 2015 INTERNATIONAL

BUILDING CODE (IBC)

REVISIONS

LTR NOR NUMBER DATE APPROVED

- 738-0306-015

BLIND STRUCTURAL BOLT SCHEDULE

PART

NUMBER NOMENCLATURE VENDOR

PART NO.

MIN

CLAMP RANGE NEXT ASSY

11B5092031-1 BLIND STRUCTURAL BOLT, SHORT BQ1GAL12C 1/2" - 15/16" 11B5000001

11B5100001

11B5092031-2 BLIND STRUCTURAL BOLT, LONG BQ3GAL12C 1-1/2" - 2-11/18" 11B5000001

DWG NO.

CONTRACT NO.

5B5M3

DAI

C

SIZE

3 PLACE DECIMALS ±

2 PLACE DECIMALS ± .03

SHEETSCALE

DRAWING APPROVAL

DESIGN APPROVAL

SUBMITTED

CHECKERDRAWN BY

(YR-MO-DA)

ORIGINAL DATE

MATERIAL

TOLERANCES ON:

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

EQUIPMENT CODE NO.

NEXT ASSY

4 3 2 1

4 3 2 1

D

C

B

A

D

C

B

A

ANGLES ± BLIND STRUCTURAL BOLT

11B5092031 2:1

R. McCLAIN

SEE SPECIFICATIONS

TABLE

SEE TABLE

ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299

U.S. ARMY COMBAT CAPABILITIES DEVELOPMENT COMMAND

CHEMICAL BIOLOGICAL CENTER

VENDOR ITEM CONTROL DRAWING

FRACTIONS ±

DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE;

DISTRIBUTION IS UNLIMITED.

C. HANEY

P. SCHLUE

Rev: -

2023-10-30

R. McCLAIN

R. McCLAIN

File details come from the government source that posted it. Updated .