11B5090106RIA_DRAW A.pdf
PDF 114 KB Posted
- Attached to
- 20 GALLON AIR TANK Federal contract opportunity
- Solicitation number
- W519TC25Q2066
About this file
This is a vendor item control drawing from the U.S. Army Research, Development and Engineering Command that provides technical specifications for a 20-gallon vertical air tank. The drawing (number 11B5090106) details requirements for a pressure vessel with a 200 PSI minimum rating, specific access ports, and a maximum space envelope of 16" wide by 16" long by 38" high.
The drawing identifies Manchester Tank (Franklin, TN) as a suggested source of supply, with their part number 302404. Key specifications include multiple NPT ports (1/4", 1/2", and 3/4") at designated locations, precise dimensional requirements including a 10.39" ±1.50" bolt pattern, and a special feature requiring any additional tank outlets to be sealed with fittings rated for the tank's maximum pressure. The drawing is approved for public release with unlimited distribution and was most recently revised on 2017-02-14 per revision A.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W519TC25Q2066.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/4" NPT
APPROX LOCATION
3/4" NPT
APPROX LOCATION
35.59
14.95
14.00
3/4" NPT
APPROX LOCATION
10.39+ .03 .12
10.39±1.50
1/2" NPT
APPROX LOCATION
SUGGESTED SOURCE OF SUPPLY
PART
NUMBER
VENDOR DATA
NAME & ADDRESS CAGE CODE VENDOR
PART NO. DESCRIPTION
11B5090106
MANCHESTER TANK
1000 CORPORATE CENTRE DRIVE
SUITE 300
FRANKLIN, TN 37067
615-370-6300
4FDC0 302404 20 GALLON, 200 PSI, VERTICAL
AIR TANK
SALIENT FEATURES
CAPACITY 20 GALLON NOMINAL
PRESSURE RATING 200 PSI MINIMUM
ACCESS PORTS AS INDICATED
BOLT PATTERN AS INDICATED
SPACE ENVELOPE NO LARGER THAN 16" WIDE BY 16" LONG BY 38"
HIGH
SPECIAL FEATURE
ANY ADDITIONAL OUTLETS IN THE AIR TANK,
NOT SPECIFIED BY SIZE AND THREAD, SHALL BE
SEALED WITH FITTINGS THAT CAN WITHSTAND
THE TANK'S MAXIMUM PRESSURE RATING
REVISIONS
LTR NOR NUMBER DATE APPROVED
- NOR 738-0001-001 2014-04-25 PMS
A 738-0133-001 2017-02-14 PMS
DWG NO.
U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND
ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299
EDGEWOOD CHEMICAL BIOLOGICAL CENTER
CONTRACT NO.
5B5M3
CAGE CODE
D
SIZE
3 PLACE DECIMALS ±
2 PLACE DECIMALS ±
SHEETSCALE
DRAWING APPROVAL
DESIGN APPROVAL
SUBMITTED
CHECKERDRAWN BY
ORIGINAL DATE
MATERIAL
TOLERANCES ON:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
EQUIPMENT CODE NO.
NEXT ASSY
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
D
C
B
A
D
C
B
A
FRACTIONS
11B5090106
2011-07-26
1:4
R. McCLAIN
R. McCLAIN
M. BLOSSER
P. SCHLUE
(YR-MO-DA)
VENDOR ITEM CONTROL DRAWING
ANGLES ±
AIR TANK
Q. HARTMAN
11B5190852
NOTES
APPLICABLE STANDARDS/SPECIFICATIONS:1.
ASME Y14.100-2004A.
ASME Y14.5-2009B.
IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF SUPPLY 2.
HEREON IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT
OR CONTINUED AVAILABILITY AS A SOURCE OF SUPPLY FOR THE
ITEM DESCRIBED ON THE DRAWING.
VENDOR PART NUMBER(S) ARE FOR REFERENCE ONLY. DRAWING 3.
SPECIFICATIONS AND DIMENSIONAL REQUIREMENTS SUPERCEDE
VENDOR PART NUMBER(S) AND/OR CATALOG CALLOUTS.
DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
REV: A
File details come from the government source that posted it. Updated .