1187348_SDS Paint.pdf

PDF 98 KB Posted

Attached to
Travel Mgmt Services
Solicitation number
2851
Issued by
Greene County, Virginia

About this file

This document appears to be a technical data sheet for a Sherwin-Williams Pro Industrial Waterbased Alkyd Urethane Enamel product. The product is recommended for use on various interior and exterior substrates such as steel, aluminum, galvanized surfaces, concrete, masonry, and wood. The data sheet provides detailed application instructions, including recommended primer coats and application rates. It also lists the product characteristics such as color, gloss, drying time, and VOC content.

The document does not appear to be related to a state or local contract opportunity. It does not contain any information about solicitations, bid requirements, quantities, award dates, contract terms, or pricing. There are no details provided about agencies, jurisdictions, or consortiums involved.

View the file

Other files

File Type Posted
1186742_Painting Services bid.pdf PDF
1190012_Addendum 1 painting.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRO

INDUSTRIAL™

113.12

WATERBASED ALKYD

URETHANE ENAMEL

B53-1051 GLOSS

B53-1151 SEMI- GLOSS

B53-1251 LOW SHEEN

Steel:

1ct. Pro Industrial Pro-Cryl Primer 2cts. Pro Industrial Waterbased Alkyd

Urethane

Aluminum:

1ct. Pro Industrial Pro-Cryl Primer 2cts. Pro Industrial Waterbased Alkyd

Urethane

Galvanizing:

1ct. Pro Industrial Pro-Cryl Primer 2cts. Pro Industrial Waterbased Alkyd

Urethane

Concrete Block:

1ct. Heavy Duty Block Filler 2cts. Pro Industrial Waterbased Alkyd

Urethane

Concrete/Masonry:

1ct. Loxon Concrete & Masonry Pri-mer 2cts. Pro Industrial Waterbased Alkyd

Urethane Drywall:

1 ct. ProMar 200 Zero VOC Primer 2 cts. Pro Industrial Waterbased Alkyd

Urethane

Wood, Exterior:

1 ct. Exterior Wood Primer 2 cts. Pro Industrial Waterbased Alkyd

Urethane Wood, Interior:

1 ct. Premium Wall & Wood Primer 2 cts. Pro Industrial Waterbased Alkyd

Urethane

System Tested: (unless otherwise indicated) Substrate: Cold Rolled Steel Finish: 1 ct. Pro Industrial Waterbased Alkyd Urethane 5 mils wet

PRODUCT DESCRIPTION

Pro Industrial Waterbased Alkyd Urethane Enamel is a premium quality interior/exterior enamel formulated with a urethane modified alkyd resin system for high performance. It provides beauty and durability when applied to interior/exterior surfaces such as properly prepared drywall, wood, masonry and metal. It brings together the convenience and ease of use of a waterborne coating with the performance and coating characteristics of a traditional oil-based enamel.

Excellent washability & flow & leveling

Excellent touch up

Easy application & cleanup

Resistant to yellowing compared to traditional alkyds

Suitable for use in USDA inspected facilities

PRODUCT CHARACTERISTICS

Color: most colors

Extra White B53W01051

Recommended Spread Rate per coat:

Wet mils: 4.0 - 5.0 Dry mils: 1.4 - 1.7 Coverage: 320 - 400 sq ft/gal (7.85-9.81 m2/L) Approximate spreading rates are calculated on volume solids and do not include any application loss. Note: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.

Drying Time @ 4.0 mils wet 50% RH:

@ 77°F To touch: 1-2 hrs To recoat: 4 hrs Drying time is temperature, humidity, and film thickness dependent.

Finish: 75+@ 60° Gloss 55-70 @ 60° Semi-Gloss 15-25 @ 60° Low Sheen Tinting with CCE:

Base oz/gal Strength Extra White 0 - 6 SherColor

Extra White B53W01051

(may vary by color and base)

VOC (less exempt solvents):

<50 g/L; <0.42 lb/gal As per 40 CFR 59.406 Volume Solids: 34 ± 2% Weight Solids: 47 ± 2% Weight per Gallon: 10.28 lb, (4.66kg) Flash Point: N/A Vehicle Type: Urethane modified alkyd

04/2019 www.sherwin-williams.com continued on back

Adhesion:

Method: ASTM D4541 Result: > 600 psi

Pencil Hardness:

Method: ASTM D3363 Result: 5H, 7 day dry

Flexibility:

Method: ASTM D522, 180° bend, 1/8" mandrel Result: Excellent no cracking

Dry Heat Resistance:

Method: ASTM D2485 Result: 200°F

Block Resistance:

Lab assessment Excellent

Resistance to Yellowing:

Lab assessment Excellent

RECOMMENDED SYSTEMS

As of 04/23/2019, Complies with:

OTC Yes LEED® 09 NC CI Yes OTC Phase II Yes LEED® 09 CS Yes SCAQMD Yes LEED® v4 Emissions No CARB Yes LEED® v4 VOC Yes CARB SCM2007 Yes Canada Yes MPI

The systems listed above are representative of the product's use, other systems may be appropriate.

The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.

APPLICATION

Refer to the SDS before using.

Temperature: 50°F(10°C) minimum 100°F(37.8°C) maximum (Air, surface, and material) At least 5°F above dew point Relative humidity: 85% maximum

The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.

Reducer: Water

Airless Spray Pressure .................................... 2000 psi Hose ............................................ 1/4" ID Tip ...................................... .013" - .017" Filter ......................................... 60 mesh Reduction .................. Not recommended

Brush ......................... Nylon / polyester Reduction .................. Not recommended

Roller ............................ 1/4-1/2" woven Reduction ................. Not recommended

If specific application equipment is listed above, equivalent equipment may be substituted.

CLEANUP INFORMATION

Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.

DANGER: Rags, steel wool, other waste soaked with this product, and sanding residue may spontaneously catch fire if improperly discarded. Immediately place rags, steel wool, other waste soaked with this product, and sanding residue in a sealed, water-filled, metal container.

Dispose of in accordance with local fire regulations.

HOTW 04/23/2019 B53W01051 11 43

SURFACE PREPARATION

WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.

Do not use hydrocarbon solvents for cleaning.

Iron & Steel - Minimum surface preparation is Hand Tool Clean per SSPC-SP2. Remove all oil and grease from surface per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6. Prime the area the same day as cleaned.

Aluminum - Remove all oil, grease, dirt, oxide and other foreign material per SSPC-SP1. Prime the area the same day as cleaned.

Galvanizing - Allow to weather a minimum of six months prior to coating. Solvent Clean per SSPC-SP1. When weathering is not possible, or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test patch. Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP16 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area the same day as cleaned.

Concrete Block - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Heavy Duty Block Filler or Loxon Block Surfacer. The filler must be thoroughly dry before topcoating.

Masonry - All masonry must be free of dirt, oil, grease, loose paint, mortar, masonry dust, etc.

Clean per SSPC-SP13/Nace 6/ ICRI No. 310.2R, CSP 1-3. Poured, troweled, or tilt-up concrete, plaster, mortar, etc. must be thoroughly cured at least 30 days at 75°F(23.9°C). Form release compounds and curing membranes must be removed by brush blasting. Brick must be allowed to weather for one year prior to surface preparation and painting. Prime the area the same day as cleaned. Weathered masonry and soft or porous cement board must be brush blasted or power tool cleaned to remove loosely adhering contamination and to get to a hard, firm surface.

Apply one coat Loxon Conditioner, following label recommendations.

Wood - Surface must be clean, dry and sound. Prime with recommended primer. No painting should be done immediately after a rain or during foggy weather. Knots and pitch streaks must be scraped, sanded and spot primed before full coat of primer is applied. All nail holes or small openings must be properly caulked.

Previously Painted Surfaces - If in sound condition, clean the surface of all foreign material.

Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary.

Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.

APPLICATION PROCEDURES

Apply paint at the recommended film thickness and spreading rate as indicated on front page.

Application of coating below minimum recommended spreading rate will adversely affect coating performance.

SAFETY PRECAUTIONS

Refer to the Safety Data Sheets (SDSs) before use. FOR PROFESSIONAL USE ONLY.

Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.

PERFORMANCE TIPS

No painting should be done immediately after a rain or during foggy weather.

When using spray application, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. Apply coating evenly while maintaining a wet edge to prevent lapping.

PRO INDUSTRIAL

WATERBASED ALKYD URETHANE ENAMEL

File details come from the government source that posted it. Updated .