This document contains an amendment to a solicitation for aggregate stockpiling services on National Forest lands in Idaho, as well as the original solicitation. The amendment provides answers to contractor questions about source and testing requirements for aggregate to be supplied. Contractors were advised to have aggregate retested by the specified lab to ensure gradation is within specifications. The original solicitation seeks a small business to furnish and stockpile aggregates on the Crooked River Road for between $250,000-$500,000. Interested small businesses are to provide capability statements and firm information to the specified contracting officer by the response deadline in order to be considered for the total set-aside contract, which will be a fixed-price award governed by FAR Part 15.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date: 6/12/2023

SUBJECT: Questions and Answers, Solicitation 1282B123R0048, Crooked River Aggregate Stockpiling - R4 Idaho

Contractor Questions:

1. Where is the supply source for the aggregate? Is it government furnished, or contractor?

supplied?

Forest Service Answer: Contractor Supplied

2. Is this a service contract and no bid bond required?

Forest Service Answer: This is a supply contract, and a bid bond is not required.

3. Provided are the lab results of the gradation test do you concur with the results?

Forest Service Answer: Aggregate does meet specification.

4. Would the lab test for F gradation that I have submitted be considered close enough for the job in Solicitation #1282B123R0048? If there is an area on the results that would not be close enough to the gradation F that the advertisement is requiring, I would like to have input from your evaluation team as to what I can do to get my 5000 cubic yards to meet this gradation F.

Forest Service Answer: Our concerns are with the ¾” and #40 outside of the allowable deviation. In the report it refers to the cleaner section, this also brings concerns. We would suggest having Allwest provide the sampling and retest the material. Please refer to Page 24 of the PDF document, Table 301-1, Sampling, Testing, and Acceptance Requirements in the Aggregate FSSS, which was included as Attachment 2 in the original Solicitation.

PROJECT NAME: SOURCE:

CLIENT NAME: PROJECT NO:

LOCATION: DATE:

S323-0309

Client

6/5/2023

Sample #1

Grading F

(Cleaner section)

Target

100 100

97-100 100

76-89 97

56-68 74

43-53 53

23-32 36

15-23 29

10.0-16.0 10.4

NV

Non-plastic

Notes:

#16

#40

SAMPLED BY:

Elk City, Idaho

TEST DESCRIPTION

1/2"

DATE SAMPLED:

Passing %

PIT

#200

#30

#50

#100

Liquid Limit

6/8/2023

LAB SAMPLE NUMBER:

Cheryl Norland

MATERIAL:

TEST RESULTS

Norstrand

Plastic Limit

#4

Plasticity Index

ATTERBERG LIMITS

AASHTO T89

www.allwesttesting.com

2705 E. Main Street • Lewiston, ID 83501 • (208) 743-5710 • Fax (208) 743-8270

Hayden, Idaho • Spokane Valley, Washington • Lewiston, Idaho • Meridian, Idaho • Missoula, Montana

DATE

This test report shall not be reproduced except in full without the permission of ALLWEST

6/9/2023REVIEWED BY

LABORATORY SUMMARY

SIEVE ANALYSIS (AASHTO T30)

323-107T

3/4"

3/8"

1 1/2"

1"

#8

#10 http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/ http://www.allwesttesting.com/