106348 - Frear Park Restaurant Pavilion - Phase 1- Issue for Bid.pdf
PDF 12 MB Posted
- Solicitation number
- 2139799
- Issued by
- Rensselaer County, New York
About this file
This is an architectural and structural drawing package for Phase 1 of the Frear Park Development Restaurant Pavilion project, a mixed-use facility in Troy, New York. The project involves the demolition of existing structures and construction of a new restaurant pavilion facility. The work encompasses extensive demolition activities including removal of existing walls, floors, roofs, doors, windows, kitchen equipment, mechanical systems, and structural elements, with selective preservation of certain existing concrete foundation walls, CMU walls, brick veneer walls, and roof assemblies. The architectural drawings detail floor plans, roof plans, elevations, wall sections, and enlarged details for the new construction, while the structural drawings provide foundation plans, footing details, and reinforcement specifications. The project is designed to the 2025 Building Code of New York State with design loads specified for floors (5 PSF dead load, 100 PSF live load for dining areas), roofs (20 PSF live load, 49 PSF snow load), and wind (110 MPH basic design wind speed). The structural design includes concrete foundations with spread footings, concrete foundation walls with reinforced concrete details, and wood-framed superstructure elements including wood posts, decking, and staircase assemblies.
The document package includes comprehensive general notes, abbreviations, legends, and material specifications governing concrete placement, reinforcement requirements, temporary bracing and shoring design, and construction sequencing. The contractor is responsible for field verification of existing conditions, design of temporary support systems, geotechnical coordination for excavation and backfill operations, and compliance with ACI concrete standards. Special inspection and testing requirements are mandated, and the contractor must engage a geotechnical engineer for on-site verification of excavation and compaction to minimum 95% Modified Proctor density. Construction scheduling must coordinate with existing facility operations, protect existing utilities, and maintain fire ratings and acoustic assemblies. The project includes hardware specifications, ADA accessibility compliance requirements, and detailed specifications for foundation wall construction with #4 and #5 reinforcing bars at 12-inch spacing, concrete frost-protected pads, and through-wall pipe penetrations requiring coordination with plumbing drawings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| _106348 City of Troy-Frear Park Dev. Restaurant Pavilion Phase 1_10.8.2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT GENERAL NOTES
1. THESE GENERAL NOTES ARE INTENDED TO COMPLIMENT THE
CONTRACT DOCUMENTS. REFER TO THE CONTRACT DOCUMENTS FOR
DETAILED INFORMATION AND ADDITIONAL REQUIREMENTS.
2. ALL WORK INCLUDED IN THIS CONTRACT SHALL CONFORM TO ALL
FEDERAL, STATE, AND LOCAL LAWS, STATUTES, ORDINANCES, CODES,
RULES AND REGULATIONS, OR LAWFUL ORDERS OF PUBLIC AUTHORITY.
PROMPTLY REPORT ANY NONCONFORMITY DISCOVERED TO THE
ARCHITECT.
3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF WORK
BY THE CONTRACTOR AND TO PROVIDE A COMPLETE, FULLY
OPERATIONAL BUILDING. PROVIDE ALL LABOR, MATERIALS AND
INCIDENTALS NECESSARY TO ACHIEVE THIS INTENT.
4. FAILURE OF THE DRAWINGS OR SPECIFICATIONS TO INDICATE EACH
INCIDENTAL SHALL NOT RELIEVE THE CONTRACTOR FROM PROVIDING
THE NECESSARY ITEMS AS PART OF THIS CONTRACT. THE DRAWINGS
SHOW THE DESIGN, LOCATION, DESCRIBE THE QUALITY LEVEL AND
CONSTRUCTION TECHNIQUES IN A GENERAL SENSE ONLY.
5. ALL DETAILS ARE TYPICAL. WHAT IS SHOWN IN ONE CONDITION APPLIES
TO ALL OTHER SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE.
6. VERIFY THE FOLLOWING ITEMS AND REPORT ANY DISCREPANCIES TO
THE ARCHITECT PRIOR TO PROCEEDING WITH WORK, AND PROCEED
WITH THE WORK ONLY AFTER SUCH DISCREPANCIES ARE RESOLVED:
EXISTING CONDITIONS
WALLS, FLOORS, ROOFS, AND SUBSTRATES WHERE PRODUCTS AND
SYSTEMS ARE TO BE INSTALLED.
SIZE AND CONDITION OF WINDOW, DOOR, LOUVER, AND OTHER
OPENINGS WHERE PRODUCTS AND SYSTEMS ARE TO BE INSTALLED.
THE EXISTENCE, SIZE, AND LOCATION OF ALL EXISTING UTILITIES,
MECHANICAL AND ELECTRICAL SYSTEMS.
DISCREPANCIES BETWEEN OR WITHIN THE CONTRACT DOCUMENTS.
UNSUITABLE SOILS: REPORT THE LOCATION OF ALL UNSUITABLE SOIL
MATERIALS BELOW ANTICIPATED LEVELS OF FOOTINGS OR SLABS PRIOR
TO SETTING FORMS.
MECHANICAL, ELECTRICAL AND PLUMBING WHICH IMPACT CEILING
INSTALLATION HEIGHTS OR BUILDING THE APPEARANCE.
DIMENSIONAL DISCREPANCIES.
7. COORDINATE THE WORK OF ALL SUBCONTRACTORS.
8. DO NOT PENETRATE STRUCTURAL BEAMS, COLUMNS, OR SHEAR WALLS
UNLESS SPECIFICALLY DETAILED OTHERWISE.
9. PROVIDE BOND-OUTS, BLOCKING, SLEEVES AND PIPES AS REQUIRED
FOR ALL WALL, FLOOR, ROOF, AND CEILING PENETRATIONS.
MAINTAIN CONTINUITY OF FIRE RATED ASSEMBLIES AND SMOKE
ASSEMBLIES. SEAL ALL PENETRATIONS TO CONFORM TO UL RATED
ASSEMBLIES AND ALL NFPA AND IBC REQUIREMENTS. REFER TO THE
CODE PLANS FOR ADDITIONAL CODE REFERENCES.
ALL PENETRATIONS SHALL COMPLY WITH THE ACOUSTICAL ASSEMBLY
RATING REQUIRED FOR EACH WALL OR FLOOR ASSEMBLY.
10. COORDINATE THE WORK TO ACHIEVE THE GIVEN VISUAL AND
PERFORMANCE REQUIREMENTS OF MECHANICAL, ELECTRICAL AND
PLUMBING SYSTEMS WITHIN THE INDICATED SPACE.
11. PROVIDE WORK HOLES OR ADEQUATE ACCESS AS REQUIRED TO
INSTALL NEW SYSTEMS IN CONCEALED SPACES.
12. PRODUCTS SHALL BEAR UL CLASSIFICATION WHERE REQUIRED BY
DESIGN. DO NOT REMOVE OR PAINT OVER UL CLASSIFICATIONS.
13. DEFINITIONS:
NEW: INDICATES ITEMS THAT SHALL BE FURNISHED AND INSTALLED BY
THIS CONTRACT. TYPICALLY USED TO ENSURE CLARITY BETWEEN
VARIOUS COMPONENTS OF THE DRAWINGS. NOT ALL ITEMS ARE
LABELED AS "NEW" WHEN IT IS OBVIOUS BY OTHER INDICATION.
EXISTING: EXISTING BUILDING OR SITE COMPONENTS WHICH ARE IN
PLACE AT THE START OF CONSTRUCTION. NOT ALL ITEMS ARE LABELED
AS "EXISTING" WHEN IT IS OBVIOUS BY OTHER INDICATION.
REPAIR: RESTORE TO SUITABLE OR APPROPRIATE OPERATING AND
AESTHETIC CONDITION.
RESTORE: BRING BACK TO FORMER CONDITION, BY REPAIRING OR
PATCHING AS REQUIRED.
PATCH: RESTORE TO CONDITION MATCHING EXISTING ADJACENT
CONSTRUCTION, SURFACE TEXTURE AND FINISH.
N.I.C. (NOT IN CONTRACT): WORK WHICH IS NOT INCLUDED IN THIS
CONTRACT, BUT WHICH MAY REQUIRE CONTRACTOR COORDINATION.
REMOVE: DISMANTLE AND/OR EXTRACT FROM THE PREMISES ENTIRELY.
DISPOSE OF OFF OF THE SITE UNLESS NOTED OTHERWISE.
REPLACE: DISMANTLE AND/OR EXTRACT FROM THE PREMISES
ENTIRELY. DISPOSE OF OFF OF THE SITE UNLESS NOTED OTHERWISE.
PROVIDE NEW MATERIAL AS INDICATED.
DAMAGES: EXISTING BUILDING OR SITE COMPONENTS, NOT SCHEDULED
FOR WORK, WHICH ARE DAMAGED. SUCH ELEMENTS AND COMPONENTS
SHALL BE REPLACED OR RESTORED TO ORIGINAL CONDITION BY
METHODS APPROVED BY THE ARCHITECT.
DEMOLISH: DISMANTLE AND/OR EXTRACT FROM THE PREMISES
ENTIRELY. DISPOSE OF OFF OF THE SITE UNLESS NOTED OTHERWISE.
SALVAGE: REMOVE AND REINSTALL OR REMOVE AND DELIVER TO THE
OWNER, AS INDICATED. SALVAGED COMPONENTS MAY BE FOR LIMITED
REUSE, TO MATCH EXISTING CONDITIONS OR TO PATCH AND REPAIR AS
INDICATED.
GENERAL DEMOLITION AND REMOVAL NOTES
1. THE DEMOLITION DRAWINGS PROVIDE GENERAL COORDINATION
INFORMATION ONLY, AND ARE SCHEMATIC IN NATURE. THEY DO NOT
IDENTIFY ALL INDIVIDUAL ITEMS TO BE REMOVED. REMOVE ANY
EXISTING CONSTRUCTION WHICH IS IN THE WAY OF NEW CONSTRUCTION
OR PROHIBITS THE NEW CONSTRUCTION.
2. VERIFY EXISTING STRUCTURAL CONDITIONS PRIOR TO DEMOLITION OR
REMOVALS
3. PROTECT FROM DAMAGE AND WEATHER ANY EXISTING BUILDING
COMPONENTS, WHICH ARE EXPOSED AS A RESULT OF DEMOLITION OR
REMOVALS.
4. COORDINATE AND SCHEDULE ALL WORK IN EXISTING OCCUPIED
PORTIONS OF THE BUILDING WITH THE OWNER.
5. NOTIFY THE ARCHITECT AND OWNER IMMEDIATELY UPON DISCOVERY
OF POTENTIALLY HAZARDOUS MATERIAL OR SUBSTANCE NOT
ADDRESSED IN THE CONTRACT DOCUMENTS, INCLUDING BUT NOT
LIMITED TO ASBESTOS, PCB, LEAD, MERCURY, AND MOLD. DO NOT
DISTURB HAZARDOUS MATERIALS. HAZARDOUS MATERIAL SHALL BE
LEGALLY ABATED, TRANSPORTED, AND DISPOSED OF.
6. CONCRETE SLAB REMOVALS MAY BE REQUIRED THROUGHOUT THE
EXISTING BUILDING AND MAY NOT BE SHOWN ON THE DEMOLITION
DRAWINGS. COORDINATE THE EXTENT OF SLAB REMOVALS WITH
STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS. CUT TRENCHES IN
EXISTING CONCRETE FLOORS WITH NO MORE THAN A 1:2 SLOPE.
PROVIDE AN UNDER-SLAB VAPOR RETARDER AT SLABS ON GRADE.
REFER TO STRUCTURAL DRAWINGS FOR REINFORCEMENT
REQUIREMENTS. PATCH CONCRETE TO MATCH ADJACENT THICKNESS
AND FINISH PRIOR TO THE INSTALLATION OF UNDERLAYMENT OR NEW
FINISHES.
7. REMOVAL OF MATERIALS SHALL BE DONE WITHOUT DISTURBING
ADJACENT SURFACES OR THE CURRENT CONDITION OF OTHER
BUILDING ELEMENTS INTENDED TO REMAIN.
8. REMOVE ALL DAMAGED AND/OR DISCARDED BUILDING CONSTRUCTION
MATERIAL FROM CONCEALED SPACES. PRIOR TO CLOSING- OR
SEALING-OFF CONCEALED SPACES, THE CONTRACTOR SHALL ALLOW
FOR AN INSPECTION OF COMPONENTS WHICH WILL NOT BE VISIBLE WHEN
THE SPACES HAVE BEEN SEALED.
9. ALL DEMOLITION/REMOVAL DEBRIS IS THE PROPERTY OF THE
CONTRACTOR, UNLESS NOTED OTHERWISE, AND SHALL BE LEGALLY
DISPOSED OF.
GENERAL PATCHING AND REPAIRING NOTES
1. WHERE NEW CONSTRUCTION EITHER INFILLS OR ABUTS EXISTING
CONSTRUCTION, THE FINISHED FACES SHALL ALIGN, AND THE
SURFACES SHALL BE FINISHED TO MATCH.
2. AFTER CUTTING, FITTING, OR REMOVAL OF BUILDING COMPONENTS, ANY
RESULTING HOLES SHALL BE PATCHED. SUCH PATCHES SHALL BE
FLUSH WITH ADJACENT SURFACES AND FINISHED TO MATCH.
3. MAINTAIN FIRE RATINGS, SMOKE RATINGS, AND ACOUSTICAL RATINGS.
4. PROVIDE METAL COVER PLATES AT ALL ABANDONED ELECTRICAL
DEVICES, FINISHED TO MATCH WALL.
1.
2.
3.
ROOF GENERAL NOTES
PROTECT ALL OPENINGS CUT IN THE ROOF. PROVIDE TEMPORARY ROOFING IF WORK
IS TO BE UNFINISHED DURING ADVERSE WEATHER CONDITIONS THROUGHOUT THE
CONSTRUCTION PHASE.
PROVIDE FLASHING AT ALL ROOF PENETRATIONS. PENETRATIONS MAY NOT BE
INDICATED ON THE ROOF PLAN. REFER TO STRUCTURAL, MECHANICAL AND
ELECTRICAL PLANS FOR NUMBER, LOCATION, AND SIZE OF PENETRATIONS.
PROTECT ROOFING MATERIALS FROM CONSTRUCTION OPERATIONS.
MATERIALS LEGEND
GRAVEL
CONCRETE MASONRY UNIT
BRICK
CONCRETE
SOIL
STEEL
WOOD FRAMING
WOOD BLOCKING
GYPSUM BOARD
PLYWOOD
BATT INSULATION
RIGID INSULATION
MINERAL WOOL BOARD INSULATION
GLASS / GLAZING MARKING
AB AIR BARRIER
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
ACT ACOUSTICAL CEILING TILE
A/C AIR CONDITIONING
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJUSTABLE
ADMIN ADMINISTRATION
ADO AUTOMATIC DOOR OPENER
AED AUTOMATED EXTERNAL DEFIBRILLATOR
AFF ABOVE FINISHED FLOOR
AH AIR HANDLER
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
AMT AMOUNT
ANOD ANODIZE
AOR AREA OF REFUGE
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ARND AROUND
AUTO AUTOMATIC
AVB AIR VAPOR BARRIER
AVG AVERAGE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWT ACOUSTICAL WALL TREATMENT
BB BULLENTIN BOARD
BD BOARD
BIT BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BM BENCHMARK
BOT BOTTOM
BRG BEARING
BRK BRICK
BSMT BASEMENT
BTU BRITISH THERMAL UNIT
BTWN BETWEEN
CAB CABINET
CB CATCH BASIN
CC CENTER TO CENTER
CF CUBIC FOOT
CF/CI CONTRACTOR FURNISHED – CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED – OWNER INSTALLED
CFMF COLD FORMED METAL FRAMING
CG CORNER GUARD
CJ CONTROL JOINT
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CO2 CARBON DIOXIDE
COL COLUMN
CONC CONCRETE
CONT CONTINUE / CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CPT CARPET
CRS COURSE
CT CERAMIC TILE
CTR CENTER
CTRL CONTROL
CU CUBIC
CUH CABINET UNIT HEATER
CWT CERAMIC WALL TILE
CY CUBIC YARD
D DEPTH
DBL DOUBLE
DC DISPLAY CASE
DEL DELETE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DMP DEMOUNTABLE PARTITION
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DW DOMESTIC WATER
DW DISHWASHEER
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EF EXHAUST FAN
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMHO ELECTRO MAGNETIC HOLD OPEN
ENCL ENCLOSED / ENCLOSURE
EP ELECTRIC PANEL
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EW EYE WASH
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAAP FIRE ALARM ANNOUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAS FIRE ALARM STATION
FB FIRE BLANKET
FBO FURNISHED BY OWNER
FCO FLOOR CLEANOUT
FD FIRE DAMPER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FG FIBERGLASS
FHVC FIRE HOSE AND VALVE CABINET
FIN FINISH / FINISHED
FIN GR FINISH GRADE
FLR FLOOR / FLOORING
FM FACTORY MUTUAL
FNDN FOUNDATION
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FO FACE OF
FP FIREPROOF / FIREPROOFING
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE RETARDENT TREATED
FT FOOT
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALLCOVERING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GFB GROUND FACE CMU
GL GLASS / GLAZING
GLU LAM GLUED LAMINATED WOOD
GUT GUTTER
GWB GYPSUM WALLBOARD
HARD HARDENER
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HD HEAVY DUTY
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSEPOWER
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HR HANDRAIL
HT HEIGHT
HTG HEATING
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HWS HARDWARE SET
ID INSIDE DIAMETER
IMP INSULATED METAL PANEL
IN INCH
INCL INCLUDE / INCLUDING
INFO INFORMATION
INSUL INSULATED / INSULATION
INT INTERIOR
INV INVERT
ABBREVIATIONS NOTE: IF THE USE OF AN ABBREVIATION IS NOT CLEAR THE
CONTRACTOR SHALL REQUEST A CLARIFICATION BEFORE PROCEEDING.
JAN JANITOR
JT JOINT
KIT KITCHEN
L ANGLE
LAB LABORATORY
LAM LAMINATE / LAMINATED
LAM GL LAMINATED GLASS
LAV LAVATORY
LB POUND
LF LINEAR FOOT
LH LEFT HAND
LOC LOCATION
LT LIGHTING
LT WT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
MDO MEDIUM DENSITY OVERLAY
MCWF MULTI-COLOR WALL FINISH
MED MEDIUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOULDING
MO MASONRY OPENING
MR MOISTURE RESISTANT
MRGB MOISTURE RESISTANT GWB
MS MOP SINK
MSF METAL STUD FRAMING
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NM NON-METALLIC
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OF/CI OWNER FURNISHED – CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED – OWNER INSTALLED
OFS OVERFLOW SCUPPER
OH OVERHEAD
OHDR OVERHEAD DOOR
OP OPAQUE
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPS OPERABLE PANEL SYSTEM
PC PRECAST CONCRETE
PERF PERFORM
PERF’D PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PORC PORCELAIN
PREFAB PREFABRICATE
PRKG PARKING
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PT PAINT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE PLASTIC
PVMT PAVEMENT
QR QUARTER ROUND
QT QUARRY TILE
RB RESILIENT BASE
RB RUBBER BASER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFERENCE
RECPT RECEPTACLE
REF REFRIGERATOR
REQ’D REQUIRED
REV REVISION
RF RUBBER FLOOR
RH RIGHT HAND
RH ROOF HATCH
RL RAIN LEADER
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RS ROUGH SAWN
S SOUTH
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SD SMOKE DAMPER
SD SMOKE DETECTOR
SD SOAP DISPENSER
SD STORM DRAIN
SECT SECTION
SF SQUARE FOOT
SGL SAFETY GLASS
SGL SINGLE
SHR SHOWER
SHT SHEET
SHTHG SHEATHING
SHT MTL SHEET METAL
SIM SIMILAR
SLDG SLIDING
SLNT SEALANT
SNR SANITARY NAPKIN RECEPTACLE
SP SPECIAL PAINT
SPEC SPECIFICATION
SPF SPRUCE-PINE-FIR
SPKR SPEAKER
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUPT SUPPORT
SURF SURFACE
SUSP SUSPENDED
SV SHEET VINYL
TB TOWEL BAR
TEL TELEPHONE
T&G TONGUE AND GROOVE
TGL TEMPERED GLASS
THK THICK
THRU THROUGH
TO TOP OF
TO FDN TOP OF FOUNDATION
TP TOILET PARTITION
TPD TOILET PAPER DISPENSER
TV TELEVISION
TWF THRU-WALL FLASHING
TYP TYPICAL
UCR UNDER COUNTER REFRIGERATOR
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VB VAPOR BARRIER
VB VINYL BASE
VC VALVE CABINET
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VP VENEER PANEL
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WGL WIRE GLASS
WH WATER HEATER
WP WATERPROOF / WATERPROOFING
WS WATER STOP
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
YD YARD
SYMBOLS
ROOM TAG
DOOR TAG
# WINDOW TAG
0.0
A41.1
FIRE RATINGS
SMOKE
1 HOUR FIRE RATED PARTITION
2 HOUR FIRE RATED PARTITION
1/2 HOUR FIRE RATED PARTITION
WALL TAG
A101
SIM
BUILDING SECTION
WALL SECTION
PLAN OR SECTION DETAIL
INTERIOR ELEVATION
EXTERIOR ELEVATION
A101
SIM
FLOOR LEVEL\VERTICAL ELEVATION
COLUMN CENTERLINE
Room name
150 SF
SPECIALTY EQUIPMENT\
TOILET ACCESSORY TAG
CASEWORK TAG
DEMOLITION KEY NOTE#
XX
A101
A101
-STOREFRONT SYSTEM TAG (SF-#)
-CURTAINWALL SYSTEM TAG (CW-#)
-DEMOUNTABLE PARTITION SYSTEM TAG (DP-#)
-INSULATED TRANSLUCENT WALL PANEL SYSTEM TAG (ITWP-#)
-DISPLAY CASE (DC-#)
TYPE 1
WALL FINISH TAG
INTERIOR SIGNAGE TAG
1.
2.
GENERAL ARCHITECTURAL NOTES
THE DRAWINGS USE A SYSTEM OF KEYED NOTES ON PLANS, ELEVATIONS AND
DETAILS. INSTRUCTIONS FOR SPECIFIC COMPONENTS OF THE WORK ARE
KEYED TO THE DRAWINGS. BUILDING SYSTEMS (PARTITIONS, ROOF &
FOUNDATION) ARE KEYED TO FLOOR PLANS, WALL SECTIONS, ROOF PLAN AND
OTHER DETAILS AS APPROPRIATE.
MAINTAIN MINIMUM MANEUVERING CLEARANCES AT DOORS IN COMPLIANCE
WITH THE ADA ACCESSIBILITY GUIDELINES (ADAAG), INCLUDING BUT NOT
LIMITED TO THE FOLLOWING EXCERPT FROM 2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN:
3.
ALL MOUNTING HEIGHTS AND CLEARANCES AT TOILET ROOMS AND
ELSEWHERE SHALL COMPLY WITH THE LATEST VERSION OF THE ADA
ACCESSIBILITY GUIDELINES (ADAAG).
BARRIER-FREE CLEARANCES ARE GIVEN. THESE CLEAR DIMENSIONS
SHALL BE MAINTAINED IN CASES OF DISCREPANCY.
ALL DIMENSIONS GIVEN FOR FIXTURE AND ACCESSORY LOCATIONS ARE
CLEAR DIMENSIONS FROM FINISHED SURFACES, UNLESS NOTED
OTHERWISE. COORDINATE ACTUAL DIMENSIONS WITH WALL
CONSTRUCTION AND FINISHES.
LOCATE ALL CONTROLS, FLUSH VALVES, SHUTOFFS AND SIMILAR ITEMS IN
ACCORDANCE WITH THE LATEST VERSION OF THE ADA ACCESSIBILITY
GUIDELINES (ADAAG).
SOME ITEMS MAY INDICATE A RANGE IN MOUNTING HEIGHT. MAINTAIN A
CONSISTENT MOUNTING HEIGHT, WITHIN THE GIVEN RANGE,
THROUGHOUT THE PROJECT, UNLESS NOTED OTHERWISE.
4.
5.
6.
7.
8.
9.
10.
11.
12.
MAINTAIN CLEAR DIMENSIONS IN ACCORDANCE WITH THE LATEST VERSION
OF THE ADA ACCESSIBILITY GUIDELINES (ADAAG).
ALL GRAB BAR COMPONENTS SHALL BE ABLE TO WITHSTAND A LOAD OF
250LBS AT ANY POINT.
INSTALL BLOCKING BEHIND ALL SURFACE-APPLIED FIXTURES, TRIM, GRAB
BARS, SHELVES, CHAIR RAILS, PICTURE RAILS, BASE MOLDINGS, TACK OR
MARKER BOARDS, WINDOW TREATMENT, WALL OR BASE CABINETS OR
COUNTERS, AND MISCELLANEOUS ACCESSORIES MOUNTED ON STUD WALLS.
ALL EXPOSED WOOD NOT INDICATED TO BE PAINTED SHALL BE NATURAL
FINISH (CLEAR).
FLOORING AND FLOOR FINISHES SHALL BE INSTALLED TO A MAXIMUM
DIFFERENTIAL OF 1/16" BETWEEN DISSIMILAR MATERIALS. PROVIDE
TRANSITION STRIPS OR THRESHOLDS (1/2" MAXIMUM) OF SAME MATERIAL AS
FLOORING AND/OR AS NOTED ON THE DRAWINGS, BETWEEN DISSIMILAR
FLOORING MATERIALS
PATCH AND LEVEL EXISTING SUBFLOORS TO RECEIVE NEW FLOOR FINISHES
AS INDICATED IN THE ROOM FINISH SCHEDULE.
ALL EXPOSED PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR
OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT.
INSTALL 2 COAT HOOKS CENTERED ON THE INSIDE OF SINGLE USER TOILET
ROOM DOORS, MOUNTED AT 48 ”AFF AND 60”AFF.
A RANGE OF MOUNTING HEIGHTS MAY BE GIVEN FOR SOME ITEMS. MAINTAIN
A CONSISTENT MOUNTING HEIGHT, WITHIN THE GIVEN RANGE, THROUGHOUT
THE PROJECT, UNLESS NOTED OTHERWISE.
13. FILL CMU SOLID WITH GROUT AT ALL SURFACE-APPLIED FIXTURES, TRIM,
GRAB BARS, SHELVES, CHAIR RAILS, PICTURE RAILS, BASE MOLDINGS, TACK
OR MARKER BOARDS, WINDOW TREATMENT, WALL OR BASE CABINETS OR
COUNTERS, AND MISCELLANEOUS ACCESSORIES MOUNTED ON CMU WALLS.
14. INSTALL TRANSITION STRIPS BETWEEN DISSIMILAR FLOORING MATERIALS.
EXISTING CONDITIONS GENERAL NOTES
1. WHERE EXISTING CONDITIONS ARE SHOWN, THEY HAVE BEEN DERIVED FROM
AVAILABLE DRAWINGS ALONG WITH SITE/FIELD VISITS AND REPRESENT THE
ARCHITECT'S / ENGINEER'S BEST ESTIMATE OF ACTUAL CONDITIONS. DEPICTED
EXISTING CONDITIONS HAVE NOT BEEN EXTENSIVELY CORROBORATED BY
FIELD INVESTIGATION.
2. ALL DIMENSIONS AND DETAILS OF EXISTING WORK INDICATED ON THE DRAWINGS
SHALL BE FIELD MEASURED AND VERIFIED BY THE CONTRACTOR PRIOR TO
PROCEEDING. FIELD CHECKING SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR. IMMEDIATELY REPORT ANY DISCREPANCIES TO THE ARCHITECT /
ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
3. THE CONTRACTOR IS CAUTIONED THAT THE WORK INVOLVES ADDITION AND / OR
RENOVATION TO AN EXISTING FACILITY WHICH PART OR ALL OF WILL REMAIN IN
OPERATION DURING CONSTRUCTION. IT IS MANDATORY THAT WORK WHICH IN
ANY WAY AFFECTS THE NORMAL OPERATION OF THE FACILITY BE COORDINATED
WITH THE OWNER.
4. IF THE EXISTING FACILTY CONTAINS FIRE RATED PARTITIONS AND / OR FIRE
RATED PENETRATIONS TO REMAIN IN THE AREA OF WORK, THEY SHALL BE
VERIFIED BY THE CONTRACTOR FOR COMPLIANCE.
C en tra l F ile
Sa ve d:
U pd at e th is te xt w ith
C en tra l f ile lo ca tio n C ur re nt L oc al
F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
123456
A
B
D
E
A
B
C
D
E
123456
C
CHA Architecture, P.C.
207.775.1059 . www.chasolutions.com Portland, ME 04101
49 Dartmouth St
PHASE 1
FREAR PARK RD.
TROY, NY 12180
/1
/2
2:
:2
PM
Au to de sk
D oc s:
//1
8.
- T ro y
Fr ea r P ar k C om pl ex Im pr ov em en ts /1
8_ Tr oy
- F re ar
P ar k Ar en a
Ad di tio n_
C H
A_
SP
T_ R
.rv t
As indicated
A-001
10/05/26 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
KL DK CM
GENERAL NOTES &
MATERIAL LEGEND
Drawing Copyright © 2026
DN
DN
WH
WH
AD-103
AD-103
AD-103
NOT IN SCOPE
AD-103
AD-101
AD-103
AD-101
OPH.
DEMOLISHED BY OWNER
REMOVE FLOOR, COLUMN, WALLS, DOORS,
WINDOWS, STAIRCASE, KITCHEN EQUIP.
CASEWORK, TOILET PARTITION, PLUMBING
FIXTURE, LIGHTINGS AND ENTIRETY
REMOVE EXISTING CONC. COLUMNS
REMOVE EXISTING CONC. PAVEMENT
- SEE CIVIL
REMOVE EXISTING HANDRAIL
AND GUARDRAIL
REMOVE EXISTING WALL,
FLOOR, DOOR, WINDOW,
WOOD STAIRS AND ENTIRETY
REMOVE EXISTING METAL
SIDING, WOOD FRAME AND
GATE ENTIRETY
EXISTING BRICK VENEER WALL
TO REMAIN, SAWCUT +/- 8"
FROM ADJACENT CMU WALL
- SEE PIC. 4/AD-101
REMOVE EXISTING OPENING
FRAMING
REMOVE EXISTING DOOR
REMOVE EXISTING
INTERIOR SHEATHING
REMOVE EXISTING WINDOW
SILL AND FRAME
AD-103
AD-103
AD-103
NOT IN SCOPE
AD-103
LINE OF WOOD
DECKING ABOVE
AD-103
1' - 4" +/-
EXISTING
RETAINING WALL
TO REMAIN
DEMOLISHED BY OWNER
REMOVE EXISTING FOUNDATION
WALL, FOOTING AND WINDOWS
ENTIRETY
EXISTING FOUNDATION WALL
AND FOOTING TO REMAIN,
SAWCUT 1' - 4"+/- FROM
ADJACENT CMU WALL
REMOVE EXISTING CONC. SLAB,
CMU WALL, CONC. STAIRCASE,
DOOR, MECHANICAL EQUIP,
PLUMBING EQUIP, KITCHEN
EQUIP, CASEWORK AND
ENTIRETY
1' - 4" +/-
CRAWL SPACEFULL BASEMENT
+/- 8"
EXISTING BRICK
TO BE REMAINED
REMOVE EXISTING
WALL ENTIRETY
EXISTING CAST
IRON DOWNSPOUT
TO BE REMAINED
EXISTING CMU WALL
TO BE REMAINED
EXISTING WALL
TO BE REMAINEDLINE OF DEMOLITION
FOUNDATION WALL BELOW
+/- 1' - 4"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
SUGGESTED STRUCTURAL DEMOLITION SEQUENCE
REMOVE EXISTING INTERIOR WALLS PERPENDICULAR TO WALL THAT IS TO REMAIN (2/AD-101).
REMOVE EXISTING INTERIOR SHEATHING ON WALL THAT IS TO REMAIN.
INSTALL ZIP SHEATHING AT UPPER PART OF WALL (1/A-101).
INSTALL 4X8 LEDGER, THREADED RODS, AND SIMPSON DTT2Z TIES (7/A-101).
NEATLY CUT AND SEPARATE THE ADJACENT LOWER ROOF MEMBRANE AND CONSTRUCTION FROM THE SOFFIT
AND EAVE OF THE MAIN STRUCTURE.
REMOVE EXISTING BUILDING ROOF.
SAWCUT EXISTING BRICK (AD-101 PIC. 3 AND PIC. 4).
REMOVE EXISTING BUILDING EXTERIOR WALLS.
SHORE EXISTING FOUNDATION AT WALL THAT IS TO REMAIN. IF FULL-DEPTH BASEMENT EXISTS IN THIS AREA, PROVIDE SHORING DESIGN SIGNED AND SEALED BY A PROFESSIONAL ENGINEER.
SAWCUT EXISTING FLOOR DECKING AND WOOD JOISTS (IF NECESSARY) ADJACENT TO THE EXISTING WALL TO
REMAIN.
REMOVE EXISTING BUILDING FLOOR.
SAWCUT EXISTING FOUNDATION WALLS (AD-101 PIC. 3 AND PIC. 4).
REMOVE EXISTING FOUNDATION WALLS.
BACKFILL.
COMPLETE FRAMING AND ZIP SHEATHING (7/A-101).
C en tra l F ile
Sa at e th is te xt w ith
C en tra l f ile lo ca tio n C ur re nt L oc al
F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
PLAN
NORTH
TRUE
NORTH
123456
A
B
D
E
A
B
C
D
E
123456
C
CHA Architecture, P.C.
207.775.1059 . www.chasolutions.com Portland, ME 04101
49 Dartmouth St
PHASE 1
FREAR PARK RD.
TROY, NY 12180
/1
/2
2:
:2
PM
Au to de sk
D oc s:
//1
8.
- T ro y
Fr ea r P ar k C om pl ex Im pr ov em en ts /1
8_ Tr oy
- F re ar
P ar k Ar en a
Ad di tio n_
C H
A_
SP
T_ R
.rv t
As indicated
AD-101
10/05/26 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
KL DK CM
DEMOLITION FLOOR
PLANS
Drawing Copyright © 2026
1/8" = 1'-0"
2 LEVEL 1 - DEMOLITION FLOOR PLAN
1/8" = 1'-0"
1 BASEMENT LEVEL - DEMOLITION FLOOR PLAN
1" = 1'-0"
3 DEMOLITION ENLARGED PLAN - BRICK VENEER CORNER
REMOVE DUCT WORK BUILT CASE
REMOVE PORTION OF
DOWNSPOUT
REMOVE PLYWOOD, BLOCKING
AND FLASHING ENTIRETY
EXISTING DOWNSPOUT
TO REMAIN, PROTECT
DURING CONSTRUCTION
SAWCUT. +/- 8" FROM CMU WALL
EXISTING FOUNDATION WALL TO REMAIN.
SAWCUT, APPROX. +/- 1' - 4" FROM CMU WALL
REMOVE EXISTING FOUNDATION WALL
DOWN TO FOOTING
PIC. 1: EXISTING ROOF CONNECTION CONDITION
PIC. 2: EXISTING DOWNSPOUT CONDITION
PIC. 3: EXISTING HVAC DUCT WORK CASE
PIC. 4: EXISTING BRICK WALL SAWCUT LOCATION
REMOVE WOOD STUD
SAWCUT, +/- 8" FROM
CMU WALL
EXISTING FOUNDATION WALL
TO REMAIN, SAWCUT APPROX.
1' - 4" FROM CMU WALL
PACKAGE 1
FREAR PARK RD.
TROY, NY 12180
0 ISSUE FOR BID 10/05/26
AD-103
AD-103
AD-103
NOT IN SCOPE
AD-103
AD-103
LINE OF PLYWOOD AND FLASHING BELOW
ROOF TO BE DEMOLISHED. CUT ROOF
MEMBRANE IN STRAIGHT LINE TO RECEIVE
NEW FLASHING MEMBRANE. DO NOT DAMAGE
EXISTING ROOF TO REMAIN
- SEE PIC. 1/AD-101
LINE OF EXISTING ROOF BELOW TO
REMAIN.
- SEE PIC. 1/AD-101
DEMOLISHED BY OWNER
REMOVE EXISTING ROOM SYSTEM W/
GUTTER, DOWNSPOUT AND ENTIRETY
REMOVE EXISTING DUCT WORK
BUILT-CASE
- SEE PIC. 3/AD-101
EXISTING CONC. ROOF ASSEMBLY
TO REMAIN
- SEE PIC. 3/AD-101
EXISTING
CONDENSER
TO REMAIN
EXISTING VENT
PITE AND
EXHAUST FAN TO
REMAIN
REMOVE EXISTING LOWER ROOF
ENTIRETY
REMOVE EXISTING LOWER ROOF
ENTIRETY
REMOVE EXISTING CHIMNEY
ENTIRETY
REMOVE EXISTING WOOD STRUCTURE
AND ROOF ASSEMBLY ENTIERTY
EXISTING ROOF AND
GUTTER TO REMAIN
AD-103
AD-103
AD-103
NOT IN SCOPE
AD-103
AD-103
DEMOLISHED BY OWNER
REMOVE EXISTING CEILING, LIGHTING,
CEILING FAN, KITCHEN HOOD,
EXHAUST, ACCESS PANEL ENTIRETY
REMOVE EXISTING DUCT WORK
BUILT-CASE
- SEE PIC. 3/AD-101
REMOVE EXISTING SOFFIT BOARD,
LIGHTING, CEILING FAN AND ENTIRETY
EXISTING CEILING TO
REMAIN
REMOVE PORTION
OF DOWNSPOUT
- SEE PIC. 2/AD-101
REMOVE EXISTING
WINDOW FRAME AND SILL
C en tra l F ile
Sa at e th is te xt w ith
C en tra l f ile lo ca tio n C ur re nt L oc al
F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
PLAN
NORTH
TRUE
NORTH
123456
A
B
D
E
A
B
C
D
E
123456
C
CHA Architecture, P.C.
207.775.1059 . www.chasolutions.com Portland, ME 04101
49 Dartmouth St
PHASE 1
FREAR PARK RD.
TROY, NY 12180
/1
/2
2:
:2
PM
Au to de sk
D oc s:
//1
8.
- T ro y
Fr ea r P ar k C om pl ex Im pr ov em en ts /1
8_ Tr oy
- F re ar
P ar k Ar en a
Ad di tio n_
C H
A_
SP
T_ R
.rv t
1/8" = 1'-0"
AD-102
10/05/26 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
KL DK CM
DEMOLITION ROOF PLANS
& RCP
Drawing Copyright © 2026
1/8" = 1'-0"
1 ROOF DEMOLITION PLAN
1/8" = 1'-0"
2 LEVEL 1 DEMOLITION RCP
PACKAGE 1
FREAR PARK RD.
LEVEL 1
0"
HIGHER FLOOR
1' - 6"
GROUND
-2' - 3"
NOT IN SCOPE
AD-103
REMOVE EXISTING BRICK VENEER WALLS,
ROOF ASSEMBLY, DOORS, WINDOWS,
LIGHTINGS AND ENTIRETY
REMOVE EXISTING METAL SIDING, WOOD
FRAME, ROOF ASSEMBLY AND GATE ENTIRETY
REMOVE EXISTING CHIMNEY ENTIRETY
REMOVE EXISTING WOOD PANELING
WALL, ROOF, FLOOR, DOOR,
WINDOWS, STAIRS AND ENTIRETY
REMOVE EXISTING CONC. STAIR
AND RAILING SYSTEM
REMOVE EXISTING DUCT WORK
BUILT-CASE
- SEE PIC. 3/AD-101
EXISTING CMU WALL TO REMAIN
EXISTING BRICK VENEER WALL TO REMAIN
-REFER TO 3/AD-101
8" +/-
EXISTING ROOF SYSTEM TO REMAIN
EXISTING CONC. FOUNDATION WALL
TO REMAIN
EXISTING CONC. ROOF SYSTEM
TO REMAIN
LEVEL 1
0"
HIGHER FLOOR
1' - 6"
GROUND
-2' - 3"
NOT IN SCOPE
AD-103
REMOVE EXISTING
CHIMNEY ENTIRETY
REMOVE EXISTING
CONC. STAIR CASE,
RAILING AND ENTIRETY
REMOVE BRICK VENEER WALLS, ROOF
ASSEMBLY, DOORS, WINDOWS, LIGHTINGS
AND ENTIRETY
EXISTING FOUNDATION WALL TO REMAIN
- SEE PIC. 4/AD-101
EXISTING BRICK VENEER WALL TO REMAIN
- SEE PIC. 4/AD-101
EXISTING ROOF AND
GUTTER TO REMAIN
REMOVE EXISTING PLYWOOD, BLOCKING, AND
FLASHING ENTIRETY
- SEE PIC. 1/AD-101
REMOVE PORTION OF DOWNSPOUT
- SEE PIC. 2/AD-101
EXISTING RAILING SYSTEM
TO REMAIN
EXISTING RETAINING WALL
TO REMAIN
EXISTING CONC. STAIR
TO REMAIN
EXISTING CMU WALL
TO REMAIN
EXISTING CAST IRON DOWNSPOUT AND
METAL DOWNSPOUT TO REMAIN,
PROTECT DURING CONSTRUCTION
- SEE PIC. 2/AD-101
LEVEL 1
0"
HIGHER FLOOR
1' - 6"
GROUND
-2' - 3"
BASEMENT
-7' - 0"
NOT IN SCOPE
AD-103
AD-103
LEVEL 1
0"
HIGHER FLOOR
1' - 6"
GROUND
-2' - 3"
BASEMENT
-7' - 0"
AD-103
DEMOLISHED
BY OWNER
LEVEL 1
0"
TOP OF EXISTING
WOOD-FRAMED WALL
TO REMAIN (VIF)
EXISTING CEILING TO REMAIN
EXISTING CMU WALLTO REMAIN
EXISTING SLAB ON GRADE
TO REMAIN
EXISTING ROOF
ASSEMBLY TO REMAIN
TOP OF EXIST BRICK
VENEER TO REMAIN (VIF)
EXISTING WD FRAME
TO REMAIN
REMOVE EXISTING
CEILING
REMOVE EXISTING
DOOR AND DOOR
FRAME
REMOVE EXISTING FLOOR
AND FRAMING
EXISTING CONC. FOUNDATION
WALL TO REMAIN
EXISTING ROOF
ASSEMBLY TO DEMOLISH
REMOVE EXIST PLYWOOD,
BLOCKING, FLASHING AND
MEMBRANE ENTIRETY
EXISTING RIM BOARD AND
SILL BOARD TO REMAIN (VIF),
NOTIFY ARCHITECT PRIOR
TO INSTALL ANYTHING NEW
GRADE
REMOVE EXISTING
INTERIOR SHEATHING
CUT EXIST. SUBFLOOR AT
FACE OF FRAMING (VIF)
EXISTING FOOTING
TO REMAIN
EXISTING ROOF MEMBRANE
TO REMAIN, CUT ROOF
MEMBRANE IN STRAIGHT LINE
TO RECEIVE NEW FLASHING
MEMBRANE. DO NOT DAMAGE
EXISTING ROOF TO REMAIN
LEVEL 1
0"
EXISTING WINDOW
TO REMAIN
EXISTING CEILING TO
REMAIN
EXISTING CMU WALL
TO REMAIN
EXISTING SLAB ON GRADE
TO REMAIN
EXISTING ROOF
ASSEMBLY TO REMAIN
TOP OF EXISTING BRICK
VENEER TO REMAIN (VIF)
REMOVE EXISTING
CEILING
REMOVE EXISTING
PLYWOOD ON
WINDOW FRAME
REMOVE FLOOR AND
FRAMING
REMOVE EXISTING
ROOF ASSEMBLY
REMOVE EXISTING
PLYWOOD, BLOCKING,
FLASHING AND
MEMBRANE ENTIRETY
EXISTING PLYWOOD AT
WINDOW FRAME TO REMAIN
EXISTING CONC. FOUNDATION
WALL TO REMAIN
EXISTING RIM BOARD
AND SILL BOARD TO
REMAIN(VIF), NOTIFY ARCHITECT PRIOR TO INSTALL ANYTHING NEW
REMOVE EXISTING
INTERIOR
SHEATHING
EXISTING TOILET PARTITION
TO REMAIN
REMOVE EXISTING
ACCESS PANEL
REMOVE EXISTING
INTERIOR SHEATHING
EXISTING WOOD-FRAMING
WALL TO REMAIN
GRADE
REMOVE EXISTING
WINDOW FRAME & SILL
EXISTING FOOTING
TO REMAIN
CUT EXIST. SUBFLOOR AT
FACE OF FRAMING (VIF)
TOP OF EXISTING
WOOD-FRAMING WALL
TO REMAIN (VIF)EXISTING ROOF MEMBRANE
TO REMAIN, CUT ROOF
MEMBRANE IN STRAIGHT LINE
TO RECEIVE NEW FLASHING
MEMBRANE. DO NOT DAMAGE
EXISTING ROOF TO REMAIN
C en tra l F ile
Sa at e th is te xt w ith
C en tra l f ile lo ca tio n C ur re nt L oc al
F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
123456
A
B
D
E
A
B
C
D
E
123456
C
CHA Architecture, P.C.
207.775.1059 . www.chasolutions.com Portland, ME 04101
49 Dartmouth St
PHASE 1
FREAR PARK RD.
TROY, NY 12180
/1
/2
2:
:2
PM
Au to de sk
D oc s:
//1
8.
- T ro y
Fr ea r P ar k C om pl ex Im pr ov em en ts /1
8_ Tr oy
- F re ar
P ar k Ar en a
Ad di tio n_
C H
A_
SP
T_ R
.rv t
As indicated
AD-103
10/05/26 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
KL DK CM
DEMOLITION ELEVATIONS
& BUILDING SECTIONS
Drawing Copyright © 2026
1/8" = 1'-0"
2 DEMOLITION EXTERIOR ELEVATION - NORTH
1/8" = 1'-0"
1 DEMOLITION EXTERIOR ELEVATION - SOUTH
1/8" = 1'-0"
3 DEMOLITION BUILDING SECTION
1/8" = 1'-0"
4 DEMOLITION BUILDING SECTION
1/2" = 1'-0"
5 DEMOLITION WALL SECTION
1/2" = 1'-0"
6 DEMOLITION WALL SECTION
PACKAGE 1
FREAR PARK RD.
DN DN
DN
A-101
NOT IN SCOPE
A-101
17/32" ZIP SYSTEM WALL
SHEATHING OR
APPROVED EQUAL.
A-101
A-101
A-101
TYP. NEW SOLID CORE
WOOD DOOR AND FRAME.
PRIMED AND PAINTED,
VERIFY SIZE IN FIELD,
PROVIDE HARDWARE SET "1"
A-101
OPH.
A-101
A-101
SIM.
VI
F
VI
F
7'
- 0
VIF
7' - 0"
A-101
A-101
LEVEL 1
0"
7/16" ZIP SYSTEM WALL
SHEATHING OR APPROVED
EQUAL, CONTINUE AND TURN
TOP OF WALL, 8D NAILS 6" O.C.
@ FIELD
EXISTING WOOD-FRAMING WALL
TOP OF EXISTING
BRICK VENEER
EXISTING TOILET
PARTITION
EXISTING ROOF
EXISTING CEILING
SIMPSON DTT2Z, ANCHOR TO
EXIST. CMU WALL W/ (8) 1/4"
DIA X 1 1/4" LONG CONCRETE
SCREWS, ALL ANCHORS ON
SAME CMU BLOCK, TYPICAL
ALL CMU WALLS
4X8 CONT. LEDGER, FASTEN TO
EXIST. STUDS W/ (2) 6" LONG
TIMBERLOK SCREWS EACH
STUD
EXISTING SLAB ON
GRADE
SEE CIVIL FOR GRADE AND
TEMP. STEPS IF REQ'D
2X STUD UNDER EACH STUD, (2)
16D TOENAIL EACH SIDE TOP &
BOTTOM
EXISTING
FOUNDATION WALL
1/2" TREADED ROD W/ PL
1/4" X 2" SQUARE WASHER
& DOUBLE NUT
OVERSIZE HOLE
THROUGH EXIST. BRICK,
FILL SPACE W/ SEALANT
EXISTING CMU WALL
BEYOND
A-101
A-101
NOT IN SCOPE
A-101
NEW MEMBRANE FLASHING.
VERIFY COMPATIBILITY WITH
EXISTING ROOF MEMBRANE
A-101
A-101
6" MIN.
EXISTING ROOFING TO REMAIN
LINE OF EXIST. ROOF
MEMBRANE (VIF.)
PROVIDE NEW DECKING AND/OR
INSULATION AS REQ'D TO
MATCH EXISTING CONDITION
EXIST.
CONDENSER
EXIST.
EXHAUST FAN
EXIST. VENT
INSULATED HOT BOX
- SEE CIVIL
1/ 2"
36"X36" EXTERIOR GRADE
ACCESS PANEL
A-101
LEVEL 1
0"
A-101
EXISTING CMU WALL
EXISTING ROOF ASSEMBLY
EXISTING CONC. ROOF
EXISTING CONC.
FOUNDATION
7/16" ZIP SYSTEM WALL
SHEATHING OR APPROVED
EQUAL., TAPE AT JOINTS
EXISTING ROOF ASSEMBLY
EXISTING BRICK VENEER WALL
SPLIT FACE CMU RETAINING
WALL
EXISTING CAST
IRON DOWN SPOUT
NEW SOLID CORE WOOD DOOR
AND FRAME. PRIMED AND
PAINTED, VERIFY SIZE IN FIELD,
PROVIDE HARDWARE SET "1"
EXISTING CONC. STAIR
3' - 2" +/-
7'
- 0
3' - 0" +/-
7'
- 0
SEE CIVIL FOR GRADE
WD STAIRCASE
WD STAIRCASE
7/16" ZIP SYSTEM WALL
SHEATHING OR APPROVED
EQUAL., TAPE AT JOINTS
ROOF ASSEMBLY,
SLOPED
1/2" / 12"
A-101
36" X 36" EXTERIOR
GRADE ACCESS PANEL
4'
- 0
HIGHER FLOOR
1' - 6"
GROUND
-2' - 3"
EXISTING CONC.
FOUNDATION WALL
7/16" ZIP SYSTEM
WALL SHEATHING OR
APPROVED EQUAL.,
TAPE AT JOINTS
EXISTING ROOF
EXISTING METAL GUTTER
EXISTING CMU WALL
EXISTING CONC. STAIR
EXISTING GUARDRAIL
EXISTING WALL
MOUNTED HANDRAIL
EXISTING CAST IRON
DOWNSPOUT
EXISTING BRICK VENEER
SEALANT
LEVEL 1
0"
EXISTING CONC.
FOUNDATION
EXISTING CMU WALL
EXISTING CONC.
ROOF
EXISTING ROOF
ASSEMBLY
17/32" ZIP SYSTEM
WALL SHEATHING OR
APPROVED EQUAL.,
TAPE AT JOINTS
EXISTING ROOF
FLASHING
EXISTING BRICK VENEER
SEALANT
EXISTING FOUNDATION
WALL BELOW
1' - 4" +/-
EXISTING CMU WALL
EXISTING DOWNSPOUT
EXISTING BRICK VENEER WALL
7/16" ZIP SYSTEM WALL
SHEATHING OR APPROVED
EQUAL., TAPE AT JOINTS
EXISTING WOOD-FRAMING
WD BLOCKING
SEALANT OVER
BACKER ROD
ROOF MEMBRANE; FULLY ADHERE
HORIZONTALLY TO EXISTING ROOF
MEMBRANE, EXTEND UP MASONRY
VERTICALLY, DO NOT ADHERE TO
MASONRY
REMOVABLE SURFACE MTD. REGLET
MECHANICALLY FASTENED
SINGLE-PLY ROOF MEMBRANE WD BLOCKING
7/16" ZIP SYSTEM
WALL SHEATHING OR
APPROVED EQUAL.EXISTING ROOF MEMBRANE OVERWRAP
6" MIN.
HARDWARE SET 1
3 EA Hinge, Full Mortise Schlage 4" Square Hinges 1 EA Single Cylinder Keyed Entry Schlage F80-ELA Storeroom Door Level Set 1 EA ADA Threshold Hager 413S - 5" Wide x Door Width w / #10 SS MS Aluminum MIL
& Lead Anchors 1 EA Gasket Hager 736 - 18 ft.
1 EA Door Bottom Sweep Hanger 750S-N x Door Width 1 EA Door Closer Sargent 1331 Series EN
A-101
A-101
GUARDRAIL
LANDING
5' - 0"
2 THREAD @ 11"
1' - 10"
ST
AI
R W
ID
TH
5'
- 0
1 1 /2"
1 1 /2"
CL
EA
R W
ID
TH
4'
- 6
1 1
/2" 1 1
/2"
TYP. HANDRAIL
A-101
1' - 0"11"
TYP. HANDRAIL
LEVEL 1
0"
A-101
2X10 WD STRINGER
TYP. 4X WOOD POST
6"
2"
TYP. 2X WOOD TOP RAIL
TYP. HANDRAIL BEYOND
- SEE PROFILE 11/A-101
3 1/2" MAX.
2X WD POST FRAME
4X WD POST
LEVEL 1
0"
SEE CIVIL FOR GRADE
3 R
IS
ER
S
7"
1'
- 9
A-101
2X10 STAIR LANDING
FRAMING
3'
- 6
2"
6"
2'
- 1
0"
WD HANDRAIL
- SEE PROFILE 11/A-101
GUARDRAIL
TYP. 4X WD
RAILING POST
TYP. 2X WD TOP RAIL
4X WD POST W/ HOT-DIP
GALVANIZED PIER-BLOCK
POST BASE4X WD POST W/ HOT-DIP GALVANIZED
PIER-BLOCK POST BASE
2X WD POST FRAMING
ADA COMPLIANCE THRESHOLD
NEW SOLID CORE WOOD DOOR
AND FRAME. PRIMED AND
PAINTED, VERIFY SIZE IN FIELD,
PROVIDE HARDWARE SET "1"
A-101
2X WOOD STUD BEYOND
2X WOOD
BLUSTERS BEYOND
2X WOOD STUD BEYOND
PRESSURE TREATED DECK BOARD
2X WD DECK FRAMING
2X10 WD STAIR STRINGER
4X WOOD POST
STAINLESS STEEL
FASTENER
2"
3'
- 0
HANDRAIL
- SEE PROFILE 11/A-101
4X WD POST W/ HOT
DIP GALVANIZED PIER-
BLOCK POST BASE
GRADE, SEE CIVIL
2X WD POST FRAMING
3'
- 6
1 1/2" D WD HANDRAIL
ALUMINUM BRACKET
1 1/2"
VIF
7' - 0"
VI
F
7'
- 0
2X4 WD STUD WALL, 16" O.C.,
INSULATE CAVITY W/ 3 1/2"
MINERAL INSULATION
7/16" ZIP SYSTEM WALL
SHEATHING OR APPROVED
EQUAL., TAPE AT JOINTS
4" SAN, VERIFY
LOCATION IN FIELD
2" CW, VERIFY
LOCATION IN FIELD
(E) CW
4" (E) SAN
2' RPZ, VIF
A-101
36"X36" EXTERIOR
GRADE ACCESS
PANEL
EQ
EQ
LEVEL 1
0"
8" M
IN
GRADE, SEE CIVIL
2X4 WD STUD WALL, 16"
O.C., INSULATE CAVITY W/
3 1/2" MINERAL INSULATION 2X6 WD ROOF FRAME,
16" O.C., INSULATE
CAVITY W/ 3 1/2"
MINERAL INSULATION
7/16" ZIP SYSTEM WALL
SHEATHING OR
APPROVED EQUAL.,
TAPE AT JOINTS
36" X 36" EXTERIOR
GRADE ACCESS PANEL
7/16" ZIP SYSTEM WALL
SHEATHING OR
APPROVED EQUAL.,
TAPE AT JOINTS
C en tra l F ile
Sa at e th is te xt w ith
C en tra l f ile lo ca tio n C ur re nt L oc al
F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
PLAN
NORTH
TRUE
NORTH
123456
A
B
D
E
A
B
C
D
E
123456
C
CHA Architecture, P.C.
207.775.1059 . www.chasolutions.com Portland, ME 04101
49 Dartmouth St
PHASE 1
FREAR PARK RD.
TROY, NY 12180
/1
/2
2:
:2
PM
Au to de sk
D oc s:
//1
8.
- T ro y
Fr ea r P ar k C om pl ex Im pr ov em en ts /1
8_ Tr oy
- F re ar
P ar k Ar en a
Ad di tio n_
C H
A_
SP
T_ R
.rv t
As indicated
A-101
10/05/26 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
KL DK CM
FLOOR PLAN, ROOF PLAN,
ELEV. & WALL SECTIONS
Drawing Copyright © 2026
1/8" = 1'-0"
1 LEVEL 1 FLOOR PLAN
1/2" = 1'-0"
12 WALL SECTION - TEMP. WALL
1/8" = 1'-0"
2 ROOF PLAN
1/8" = 1'-0"
5 EXTERIOR ELEVATION EAST
1/8" = 1'-0"
3 EXTERIOR ELEVATION NORTH
1/8" = 1'-0"
4 EXTERIOR ELEVATION SOUTH
1 1/2" = 1'-0"
6 ENLARGED PLAN - CORNER ON BRICK VENEER WALL
1 1/2" = 1'-0"
9 SECTION DETAIL - TOP OF WALL
1/2" = 1'-0"
8 ENLARGED PLAN -STAIRS
1/2" = 1'-0"
13 ELEVATION - STAIRCASE
1/2" = 1'-0"
15 SECTION DETAIL - STAIR
1/2" = 1'-0"
14 STAIR SECTION - GUARD RAIL
3" = 1'-0"
11 HAND RAIL PROFILE
1/2" = 1'-0"
7 ENLARGED PLAN - INSULATED HOT BOX
1/2" = 1'-0"
10 WALL SECTION - INSULATED HOT BOX
DESIGN LOADS ARE BASED ON THE 2025 BUILDING CODE OF NEW YORK STATE.
FLOOR DEAD LOADS:
5" CONCRETE SLAB 62 PSF
ROOF DEAD LOADS: 20 PSF
FLOOR LIVE LOADS: UNIFORM
ASSEMBLY AREAS
LOBBIES: 100 PSF
CORRIDORS
FIRST FLOOR: 100 PSF
DINING ROOMS AND RESTAURANTS: 100 PSF
STORAGE: 100 PSF
OFFICE: 100 PSF
RETAIL: 100 PSF
ROOF LIVE LOAD: 20 PSF
ROOF SNOW LOAD:
GROUND SNOW LOAD, Pg: 61 PSF FLAT-ROOF SNOW LOAD, Pf: 49 PSF SNOW EXPOSURE FACTOR, Ce: 1.0 SNOW LOAD IMPORTANCE FACTOR, Is: 1.0 THERMAL FACTOR, Ct: 1.13 SLOPE FACTOR(S), Cs: 1.0
WIND DESIGN DATA:
BASIC DESIGN WIND SPEED (3-SECOND GUST), V: 110 MPH
ALLOWABLE STRESS DESIGN WIND SPEED, Vasd: 85 MPH
RISK CATEGORY: II
WIND EXPOSURE CATEGORY: C
INTERNAL PRESSURE COEFFICIENT, GCpi: +/- 0.18
GEOTECHNICAL INFORMATION:
DESIGN ALLOWABLE SOIL BEARING PRESSURE: 3,000 PSF
MOIST UNIT WEIGHT OF BACKFILL 125 PSF
INTERNAL FRICTION ANGLE OF BACKFILL 32 DEGREES
EQUIVALENT "ACTIVE" FLUID UNIT WEIGHT OF BACKFILL 38.75 PCF
COEFFICIENT OF "AT-REST" LATERAL EARTH PRESSURE 0.47
COEFFICIENT OF "ACTIVE" LATERAL EARTH PRESSURE .31
COEFFICIENT OF "PASSIVE" LATERAL EARTH PRESSURE 3.25
COEFFICIENT OF SLIDING FRICTION STRUCTURAL FILL 0.45
COEFFICIENT OF SLIDING FRICTION CLAY/SILT SOIL 0.30
MINIMUM SAFETY FACTOR AGAINST SLIDING AND OVERTURNING 1.5
MINIMUM SAFETY FACTOR AGAINST OVERTURNING 2.0
THIS BUILDING or STRUCTURE IS NOT DESIGNED FOR FLOOD LOADS.
ROOF RAIN LOAD DATA:
RAIN INTENSITY:
15 MINUTE 5.5 IN/HR
60 MINUTE 2.43 IN/HR
DESIGN CRITERIA
C e n tr a l F ile
S a v e d
U p d a te t h is t e x t w it h C e n tr a l fi le l o c a ti o n
C u rr e n t L o c a l F ile
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE
STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING
ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND
SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE
NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
Submittal / RevisionNo. App'd. By Date
Designed By: Drawn By: Checked By:
Issue Date: Project No: Scale:
Drawing No:
AS SHOWN
518.453.4500 www.chasolutions.com Albany, NY 12205-0269
3 Winners Circle, Suite 100
/1 /2
:5
:1
P
M A u to d e s k D o c s /1
.0
T ro y F re a r P a rk
C o m p le x I m p ro v e m e n ts
/1
T ro y F re a r P a rk
C
H A
S tr u c t_
R
.r v t
S-001
10/1/2026 106348
FREAR PARK
DEVELOPMENT
RESTAURANT PAVILION
AMV ST XX
NOTES, LEGENDS AND
ABBREVIATIONS
Drawing Copyright © 2025
FREAR PARK RD.
TROY, NY 12180
ABBREVIATIONS
ADDL ADDITIONAL
ADH ADHESIVE
ADJ ADJACENT
AFF ABOVE FINSIHED FLOOR
AHR ANCHOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECT
@ AT
B/B BACK TO BACK
BEV BEVEL
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF
BOF BOTTOM OF FOOTING
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BSMT BASEMENT
CANTL CANTILEVER
CFMF COLD FORMED METAL FRAMING
CHFR CHAMFER
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTER LINE
CLKJ CAULKED JOINT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
COORD COORDINATE
CSK COUNTER SUNK
CU FT CUBIC FEET
CU YD CUBIC YARD
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EOD EDGE OF DECK
EOS EDGE OF SLAB
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EX, EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATE
FBO FURNISHED BY OTHERS
FD FLOOR DRAIN
FDTN FOUNDATION
FLR FLOOR
FOM FACE OF MASONRY
FRMG FRAMING
FS FOOTING STEP
FT FOOT
FTG FOOTING
FW FIRE WALL
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GDR GUARD RAIL
GR BM GRADE BEAM
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HIGH POINT
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCHES
INFO INFORMATION
INSUL INSULATION
INV INVERT
ISO JT ISOLATION JOINT
JBE JOIST BEARING ELEVATION
K KIPS
K-FT KIP FEET
KB KNEE BRACE
KO KNOCKOUT
KPL KICK PLATE
KSF KIPS PER SQUARE FOOT
KWY KEY WAY
LBS POUNDS
LD BRG LOAD BEARING
LG LONG
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LONG LONGITUDINAL
LP LOW POINT
LWT LIGHTWEIGHT
ABBREVIATIONS
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL - ELECRICAL -
PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MTL METAL
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
NWT NORMAL WEIGHT
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
PAF POWDER ACTUATED FASTENER
PCC PRECAST CONCRETE
PEMB PRE ENGINEERED METAL
BUILDING
PL PLATE
PLAT PLATFORM
PLF POUNDS PER LINEAR FOOT
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PT PRESSURE TREATED
PUR PURLINS
PVMT PAVEMENT
QC QUALITY CONTROL
R RADIUS
RD ROOF DRAIN
RDG INS RIGID INSULATION
REF REFRENCE
REINF REINFORCING
REM REMAINDER
REQD REQUIRED
RET RETAINING
RH ROOF HATCH
RO ROUGH OPENING
SCHED SCHEDULE
SF SQUARE FEET
SIM SIMILAR
SOG SLAB ON GROUND
SPA SPACE(S)
SPEC SPECIFICATION
SQ SQUARE
SST STAINLESS STEEL
STA STATION
STD STANDARD
STL STEEL
T&B TOP AND BOTTOM
TD TRENCH DRAIN
TEMP TEMPORARY
THK THICKNESS
THRU THROUGH
TO TOP OF
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
UNEX UNEXCAVATED
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
VR VAPOR RETARDER
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WF WALL FOOTING
WP WORKING POINT
WS WALL STEP
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XS EXTRA STRONG
XXS DOUBLE EXTRA STRONG
CAST-IN-PLACE CONCRETE NOTES
1. REFER TO DIVISION 3 OF THE PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS.
2. DETAIL, FABRICATE, LABEL, SUPPORT AND PLACE CONCRETE REINFORCEMENT IN ACCORDANCE WITH ACI 315 "GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE," APPLICABLE EDITIONS. PLACE CONCRETE IN ACCORDANCE WITH ACI 117 “SPECIFICATION FOR TOLERANCES
FOR CONCRETE CONSTRUCTION AND MATERIALS AND COMMENTARY”, APPLICABLE EDITION.
3. A QUALITY CONTROL PROGRAM OF SPECIAL INSPECTIONS AND TESTING WILL BE PERFORMED ON STRUCTURAL CONCRETE WORK IN ACCORDANCE WITH THE SPECIFICATIONS. SCHEDULE WORK AND PROVIDE ACCESS TO ALLOW THE
TESTING REQUIREMENTS TO BE COMPLETED.
4. SUBMIT ENGINEERED CONCRETE MIX DESIGNS, INCLUDING REQUIRED BACKUP DATA, FOR EACH TYPE OF CONCRETE PROPOSED FOR USE TO THE ENGINEER/ARCHITECT FOR REVIEW. ALLOW ADEQUATE TIME FOR REVIEW PRIOR TO
PERFORMING CONCRETE WORK.
5. SUBMIT DETAILED SHOP DRAWINGS INDICATING REINFORCEMENT SIZE, SPACING AND PLACEMENT TO THE ENGINEER/ARCHITECT FOR REVIEW PRIOR TO FABRICATION. INCLUDE DETAILS AND LOCATIONS OF ALL CURBS, CONSTRUCTION JOINTS, SLAB DEPRESSIONS, SLEEVES, OPENINGS, ETC.
6. PROVIDE CONSTRUCTION AND CONTROL JOINTS AS INDICATED. HORIZONTAL CONSTRUCTION JOINTS ARE NOT PERMITTED UNLESS SPECIFICALLY NOTED. SUBMIT JOINT PLAN TO ENGINEER/ARCHITECT PROPOSED JOINT PLAN FOR
REVIEW.
7. PROVIDE CORNER BARS IN STRIP FOOTINGS AND WALLS, THE SAME SIZE AND NUMBER AS CONTINUOUS
REINFORCEMENT UNLESS NOTED OTHERWISE.
8. PROVIDE 3/4"x3/4" CHAMFER AT ALL EXPOSED CORNERS UNLESS NOTED OTHERWISE.
9. REINFORCEMENT LAP SPLICE ARE TO BE CLASS B UNLESS NOTED OTHERWISE.
10. LAP WELDED WIRE REINFORCEMENT ONE FULL MESH +2 INCHES PANEL EXCEPT AT CONSTRUCTION JOINTS, PROVIDE
TWO FULL MESH PANELS.
11. FOR STEEL FRAMED FLOORS, PROVIDE ADDITIONAL CONCRETE AS NECESSARY TO FINISH THE FLOORS TO WITHIN SPECIFIED TOLERANCES WHILE ACCOUNTING FOR METAL DECK AND STEEL BEAM DEFLECTIONS. ALLOW FOR AN
AVERAGE OF AT LEAST 1/2 INCH EXTRA OF CONCRETE FOR EACH FLOOR.
12. PROVIDE FOUNDATION DOWELS TO MATCH WALL REINFORCEMENT SIZE AND SPACING.
13. COORDINATE WITH RESPECTIVE DISCIPLINE CONTRACTORS TO LOCATE OPENINGS/SLEEVES THROUGH WALLS AND SLABS. SHOW OPENINGS ON SHOP DRAWING AND PROVIDE ADDITIONAL REINFORCEMENT AS INDICATED. ADDITIONAL OPENING/SLEEVES ARE NOT PERMITTED BEYOND THOSE SHOWN ON THE REVIEWED SHOP DRAWINGS.
14. NO HOLES OR OPENINGS ARE PERMITTED THROUGH CONCRETE SLABS, BEAMS, OR WALLS EXCEPT AS FOLLOWS:
A. WHERE INDICATED AND AS DETAILED ON DRAWINGS.
B. MISCELLANEOUS HOLES THROUGH SLABS OR WALLS WHICH DO NOT DISPLACE REINFORCEMENT. THESE DO NOT
REQUIRE ADDITIONAL REINFORCEMENT.
15. DO NOT PLACE CONDUITS WITHIN THE STRUCTURAL SLABS.
16. CENTER SINGLE LAYER OF VERTICAL WALL REINFORCEMENT WITHIN WALL, UNLESS NOTED OTHERWISE.
17. REFER TO ACI 305 FOR REQUIREMENTS FOR PLACING CONCRETE IN HOT WEATHER AND TO ACI 306 FOR REQUIREMENTS
FOR PLACING CONCRETE IN COLD WEATHER.
18. PLACE PIERS WHICH ARE INTEGRAL WITH FOUNDATION WALLS MONOLITHICALLY.
19. CONCRETE THAT WILL BE PLACED FURTHER THAN 16 FEET FROM THE END OF A CONCRETE TRUCK SHALL BE PUMPED WITH A COMMERCIAL CONCRETE PUMPING TRUCK OR OTHER PLACEMENT METHOD APPROVED BY THE ENGINEER. THE CONCRETE TRUCK SHALL NOT BE ALLOWED TO DRIVE OVER THE SUBGRADE OR THE SLAB REINFORCEMENT.
20. DO NOT WELD OR FIELD BEND REINFORCEMENT WITHOUT ENGINEER'S WRITTEN ACCEPTANCE.
21. PROVIDE A ROUGH CONCRETE SURFACE (1/4" MINIMUM AMPLITUDE) AT THE INTERSECTION OF CONCRETE WALLS, STEM WALLS, AND PILASTERS WITH THE TOP OF FOOTINGS. DO NOT PROVIDE A KEYWAY UNLESS SHOWN OR NOTED ON THE
DRAWINGS
22. LOCATE ADDITIONAL CONSTRUCTION JOINTS AS REQUIRED TO FACILITATE CONSTRUCTION AS ACCEPTABLE TO ENGINEER. LOCATE WALL CONSTRUCTION JOINTS AT MASONRY CONTROL JOINTS WHERE POSSIBLE. PLACE REINFORCEMENT CONTINUOUSLY THROUGH JOINT. DETAIL JOINT AND SHOW ON SHOP DRAWINGS.
23. WHERE MASONRY VENEER IS LOCATED ADJACENT TO WALLS, STEM WALLS, COLUMNS AND GRADE BEAMS GREATER THAN 24 INCHES HIGH, PROVIDE FULL HEIGHT DOVETAIL SLOT INSERTS AT 2’-0” OC FOR MASONRY ANCHORS. PLACE ANCHORS AT 16" OC VERTICALLY. COORDINATE WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
24. NO PIPING OR CONDUITS SHALL BE INSTALLED IN ANY CONCRETE WITHOUT THE APPROVAL OF THE ENGINEER.
28 DAY MINIMUM
COMPRESSIVE
STRENGTH
EXPOSURE
CLASS MAXIMUM w/cm
NOMINAL MAXIMUM
AGGREGATE SIZE
AIR CONTENT
PERCENT
FOUNDATIONS/FOOTINGS
WALLS
SLAB-ON-GROUND (EXTERIOR)
ALL OTHER CONCRETE
F2 F2 F1 F2
4,500 PSI
4,500 PSI
3,500 PSI
4,500 PSI
0.45 0.45 0.55 0.45
1 1/2" 1"
3/4" 1"
5.5% 6% 5% 6%
REINFORCEMENT
TYPICAL BARS ASTM A615, GRADE 60
WELDED BARS ASTM A706, GRADE 60
WELDED WIRE REINFORCEMENT ASTM A1064
26. PROVIDE CONCRETE AND REINFORCING MATERIALS OF THE TYPES AND GRADES LISTED IN THE TABLE BELOW:
25. PROVIDE CLEAR COVER FOR ALL REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE IN THE
DETAILS:
SPECIFIED COVER, INCHES
CAST AGAINST EARTH AND PERMANENTLY IN CONTACT WITH GROUND 3
EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
NO. 6 THROUGH NO 18 BARS 2
NO. 5 BAR AND SMALLER OR WELDED WIRE REINFORCEMENT 1 1/2
NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, JOISTS, AND WALLS
NO. 14 AND NO 18 BARS 1 1/2
NO. 11 BAR AND SMALLER 3/4
BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES
PRIMARY REINFORCEMENT, STIRRUPS, TIES, SPIRALS, AND HOOPS 1 1/2
GENERAL NOTES
1. REFER TO THE PROJECT MANUAL FOR GOVERNING JOB REQUIREMENTS AND MATERIAL SPECIFICATIONS. NOTES ARE SUPPLEMENTAL TO THE PROJECT MANUAL AND ARE NOT INTENDED TO REPLACE THEM. IN THE EVENT OF CONFLICTING REQUIREMENTS BETWEEN NOTES AND SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN THE ENGINEER'S or
DIRECTOR'S REPRESENTATIVE'S WRITTEN CLARIFICATION.
2. VERIFY EXISTING CONDITIONS AND REPORT, IN WRITING, ANY DISCREPANCIES TO THE ENGINEER or DIRECTOR'S
REPRESENTATIVE PRIOR TO COMMENCING WORK.
3. DETERMINE EXACT LOCATION OF EXISTING UTILITIES PRIOR TO COMMENCING WORK. THE CONTRACTOR IS RESPONSIBLE FOR DAMAGES WHICH MIGHT BE OCCASIONED BY THE FAILURE TO LOCATE AND PRESERVE UTILITIES.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF TEMPORARY AND PERMANENT SHEETING AND SHORING SYSTEMS TO ADEQUATELY SUPPORT EXISTING STRUCTURES AND APPURTENANCES. THE DESIGN(S) ARE TO BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE or COMMONWEALTH OF XXX AND SUBMITTED TO THE ENGINEER or DIRECTOR'S REPRESENTATIVE FOR RECORD.
5. DRAWINGS REPRESENT THE BUILDING'S or STRUCTURE'S FINAL CONDITION. ADEQUATELY BRACE AND SUPPORT THE BUILDING or STRUCTURE AS REQUIRED THROUGHOUT CONSTRUCTION UNTIL STRUCTURAL ELEMENTS REQUIRED FOR STABILITY ARE EFFECTIVE. THESE ELEMENTS ARE AS FOLLOWS: BASEMENT WALLS, FLOOR DECK, ROOF DECK, BRACING MEMBERS, MOMENT CONNECTIONS, AND SHEAR WALLS. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF TEMPORARY SYSTEMS WHICH ARE TO BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NEW YORK AND SUBMITTED TO THE ENGINEER or DIRECTOR'S REPRESENTATIVE FOR RECORD.
6. CONSTRUCTION AND ERECTION SEQUENCES ARE TO ACCOUNT FOR THERMAL MOVEMENT OF STRUCTURAL ELEMENTS
UNTIL THE BUILDING ENCLOSURE IS THERMALLY STABILIZED.
7. THE CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS, SEQUENCE OF CONSTRUCTION, AND ADEQUACY OF THE BUILDING or STRUCTURE TO SUPPORT LOADS IMPOSED DURING CONSTRUCTION. LOADS IMPOSED ON THE BUILDING or STRUCTURE DURING CONSTRUCTION ARE NOT TO EXCEED THE DESIGN LOADS DEFINED ON S-001. REPAIR TO THE BUILDING or STRUCTURE DURING CONSTRUCTION IS THE CONTRACTOR'S RESPONSIBILITY AND IS TO BE SUBMITTED, IN WRITING, FOR THE ENGINEER'S or DIRECTOR'S REPRESENTATIVE'S WRITTEN ACCEPTANCE.
8. SECTIONS/DETAILS APPLY TO SIMILAR LOCATIONS AND CONDITIONS UNLESS OTHERWISE…