10-D-001 Proposed Storm Improvements Plan.pdf
PDF 135 KB Posted
- Attached to
- Cornell Street Storm Sewer Improvements Project
- Solicitation number
- US.255316
- Issued by
- Berks County, Pennsylvania
About this file
This file is a Proposed Storm Sewer Improvements Plan prepared by Great Valley Consultants for Lower Alsace Township, Berks County, Pennsylvania. The project consists of removing existing concrete gutters, rubblizing the existing concrete channel, installing a 12-inch diameter HDPE storm pipe, providing watertight connections to existing inlets, and performing trench restoration along Cornell Street. The plan shows the proposed storm sewer improvements at a scale of 1 inch equals 10 feet, with detailed specifications for pavement restoration including Superpave asphalt design and compacted 2A modified aggregate base. The project involves four new Type M and Type C inlets located at specified points along Cornell Street, Marshall Avenue, and Friedensburg Road. Proposals are due on October 13, 2026, at 10:00 a.m. via PennBid, with a sixty-day completion deadline following Notice to Proceed. Bid proposals must be accompanied by a cash, certified check, money order, or surety bond in an amount equal to at least 10% of the total proposal, with proposals remaining effective for sixty days.
The successful bidder is required to furnish Performance, Payment, and Maintenance Bonds equal to 100% of the total contract amount from an approved surety company authorized to transact business in Pennsylvania, along with proof of liability insurance and worker's compensation insurance. This project is subject to the Pennsylvania Prevailing Wage Act, requiring contractors to pay applicable prevailing minimum wage rates. Escalator provisions for bituminous materials shall follow PennDOT Publication 408 Section 110.04, latest edition, except as specified in the Township's Resolution regarding price adjustment for bituminous materials on small quantities. Lower Alsace Township reserves the right to reject any or all proposals. The plan document, prepared on September 16, 2026, provides engineering specifications and site details necessary for bid preparation and project execution.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Appendix A.pdf | ||
| 2-Appendix B.pdf | ||
| 7-Bidders Sworn Qualification Statement.pdf | ||
| 9-A-002 Project Location Map.pdf | ||
| 3-Non-Collusion Affidavit.pdf | ||
| 8-Specifications.pdf | ||
| 6-Form of Bid Bond.pdf | ||
| 5-Subcontractors List.pdf | ||
| 4-MS944.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
FRIEDENSBURG ROAD (SR 2071)
AutoCAD SHX Text
CORNELL STREET
AutoCAD SHX Text
MARSHALL AVENUE
AutoCAD SHX Text
MARSHALL AVENUE
AutoCAD SHX Text
CONC. GUTTER
AutoCAD SHX Text
CONC. CURB
AutoCAD SHX Text
CONC. CURB
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. CURB
AutoCAD SHX Text
CONC. CURB
AutoCAD SHX Text
REMOVE EXISTING CONCRETE GUTTER AND INSTALL 12" HDPE STORM SEWER (SEE DETAIL)
AutoCAD SHX Text 2'x3' TYPE M INLET
AutoCAD SHX Text 2'x3' TYPE M INLET
AutoCAD SHX Text 2'x4' TYPE M INLET
AutoCAD SHX Text 2'x4' TYPE C INLET
AutoCAD SHX Text
CONC. GUTTER
AutoCAD SHX Text
CORNELL STREET
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
RIGHT-OF-WAY
AutoCAD SHX Text
PHILIP L. & DIANE P. PRICE PIN 23531720919269 601 FRIEDENSBURG RD.
AutoCAD SHX Text
ALISON LYNN BECKER PIN 23532717010243 29 CORNELL ST.
AutoCAD SHX Text
DEBORAH A. SMITH PIN 23532717010262 27 CORNELL ST.
AutoCAD SHX Text
COR BERK HOLDINGS LLC PIN 23531720918244 573 FRIEDENSBURG RD.
AutoCAD SHX Text
ANNEMARIE TYLER PIN 23531720918273 4 ALSACE CT.
AutoCAD SHX Text
TRACI LYNN JOHNSON PIN 23531720918280 6 ALSACE CT.
AutoCAD SHX Text
JOHN P. & MOLLIE L. ZIEMBA PIN 23531720919109 8 ALSACE CT.
AutoCAD SHX Text
JOSEPH A. & MARY ANN GOHEEN PIN 23531720919127 10 ALSACE CT.
AutoCAD SHX Text
ROBERT R. & SHEILA M. SHUMAN PIN 23532717010122 583 MARSHALL AVE.
AutoCAD SHX Text
PROVIDE WATERTIGHT CONNECTION TO EXISTING INLET
AutoCAD SHX Text
PROVIDE WATERTIGHT CONNECTION TO EXISTING INLET
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
ALLEY CONSULTANTS
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVALS:
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SURVEY NOTEBOOK:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAFTED BY:
AutoCAD SHX Text
GREAT
AutoCAD SHX Text
FILE NAME:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ENGINEERS ARCHITECTS PLANNERS SURVEYORS CONSULTANTS
AutoCAD SHX Text
75 COMMERCE DRIVE
AutoCAD SHX Text
PHONE: 610-375-8822
AutoCAD SHX Text
WYOMISSING, PA 19610-1038
AutoCAD SHX Text
C 2026 ALL RIGHTS RESERVED
AutoCAD SHX Text
FAX: 610-375-8977
AutoCAD SHX Text www.greatvalleyconsultants.com
AutoCAD SHX Text 3051-069-D-001
AutoCAD SHX Text
1200 CARSONIA AVENUE, READING, PA 19606
AutoCAD SHX Text
JRM
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text
CORNELL STREET STORM SEWER IMPROVEMENTS
AutoCAD SHX Text
PROPOSED STORM SEWER IMPROVEMENTS PLAN
AutoCAD SHX Text
LOWER ALSACE TOWNSHIP, BERKS COUNTY, PENNSYLVANIA
AutoCAD SHX Text
LOWER ALSACE TOWNSHIP
AutoCAD SHX Text 9/16/26
AutoCAD SHX Text P:\3000\3051 - Lower Alsace Twp\069 - Cornell St Storm Improvements\Proposed Storm Improvements.dwg
AutoCAD SHX Text
EXISTING PROPERTY LINE
AutoCAD SHX Text
EXISTING RIGHT-OF-WAY LINE
AutoCAD SHX Text
EXISTING STORM SEWER
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
EXISTING 10' CONTOURS
AutoCAD SHX Text
EXISTING 2' CONTOURS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED STORM SEWER IMPROVEMENTS PLAN SCALE: 1"=10'
AutoCAD SHX Text 1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED STORM SEWER
AutoCAD SHX Text NOTE: : 1. EXISTING CONDITIONS PER PASDA AERIAL IMAGERY AND LIDAR ELEVATION DATA.EXISTING CONDITIONS PER PASDA AERIAL IMAGERY AND LIDAR ELEVATION DATA.
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
%%UPERMANENT PAVEMENT RESTORATION
AutoCAD SHX Text
SEAL JOINT
AutoCAD SHX Text
WITH PG64-22
AutoCAD SHX Text
(8" MIN. WIDTH)
AutoCAD SHX Text
36" MIN.
AutoCAD SHX Text
1 1/2" MIN. SUPERPAVE ASPHALT
AutoCAD SHX Text
DESIGN, 9.5 MM, PG64-22,
AutoCAD SHX Text
WEARING COURSE, SRL-M
AutoCAD SHX Text
SUPERPAVE ASPHALT
AutoCAD SHX Text
DESIGN, 25.0 MM, 4" DEPTH,
AutoCAD SHX Text
PG64-22, BASE COURSE
AutoCAD SHX Text
EXISTING CURB (TO REMAIN)
AutoCAD SHX Text
EXISTING STREET CONSTRUCTION
AutoCAD SHX Text
RUBBLIZE EXISTING BOTTOM OF CONCRETE CHANNEL TO ALLOW FOR DRAINAGE
AutoCAD SHX Text EXPOSED VERTICAL AND HORIZONTAL SURFACES SHALL BE PREPARED AS PER PUB. 408, SECT. 401.3(f)
AutoCAD SHX Text
COMPACTED 2A MODIFIED AGGREGATE (6" MAX. LIFTS)
AutoCAD SHX Text
12" DIAMETER HDPE-SB
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
%%USAWCUT AND CONCRETE GUTTER REMOVAL
AutoCAD SHX Text
EXISTING CONCRETE CURB
AutoCAD SHX Text
NOTE: : EXISTING CONCRETE CHANNEL TO REMAIN.
AutoCAD SHX Text
EXISTING CONCRETE CHANNEL
AutoCAD SHX Text
REMOVE EXISTING CONCRETE GUTTER
AutoCAD SHX Text
EXISTING CONCRETE CHANNEL (TO REMAIN)
| Sheets and Views |
| D-001 |
File details come from the government source that posted it. Updated .