ADA Restroom Renovation Construction Plans for Chestnuthill Township Park
This is a construction plan set prepared by Reilly Associates for Chestnuthill Township in Monroe County, Pennsylvania, detailing the renovation of two existing restrooms into ADA-compliant facilities at Chestnuthill Community Center located at 221 Route 715, Brodheadsville, PA 18322. The project involves the complete renovation of existing male and female restrooms, with the women's restroom relocating to the existing men's restroom space and vice versa. Construction work is mandated to occur between August 3, 2026, and September 30, 2026. According to the related advertisement for bids, sealed bids will be received online via PennBid until 3 PM local time on April 29, 2026, with awards to be considered at the Township Board of Supervisors meeting scheduled for May 5, 2026, at 7:00 PM. A non-mandatory pre-bid conference will be held on April 16, 2026, at 9:00 AM at the Chestnuthill Township Municipal Building (271 Route 715, Brodheadsville, PA 18322) with a site visit to follow. The project is a single prime contract with bids submitted on a lump sum basis. Bidding documents are available at no cost on PennBid (www.pennbid.bonfirehub.com).
The plan set specifies detailed renovations including installation of ADA-compliant water closets, relocation of hand lavatories, hand dryers, folding baby changing stations, bathroom partitions, mirrors, and lighting upgrades. Materials include American Standard fixtures (Cadet toilets, Lucerne lavatories, Washbrook urinals), Progress Lighting and Lithonia fixtures, Sherwin Williams paints and epoxy flooring (Resurflo Aqua 3460), stainless steel grab bars and hardware, and FRP wall panels. All construction must comply with the Architectural Barriers Act of 1968, Section 504 of the Rehabilitation Act of 1973, Pennsylvania Act 235, the Americans with Disabilities Act, Pennsylvania Uniform Construction Code, International Building Code 2018, and ICC A117.1-2017. The contractor is responsible for obtaining required township permits, with permit fees waived by the township. Pennsylvania Prevailing Wage requirements apply to this contract, and the project is funded in part by the Department of Conservation and Natural Resources Bureau of Recreation and Conservation Keystone Recreation, Park and Conservation Fund (DCNR Project Number BRC-PRD-30-59) and the Commonwealth of Pennsylvania, Commonwealth Financing Authority.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Project Manual.pdf | ||
| 2-Project Manual.pdf | ||
| 1-AMERICAN LEGION PLANS.pdf | ||
| 1-Project Manual 1 5 2026.pdf | ||
| 2-CHT PICKLEBALL Plan Set 2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION PLANS
for
CHESTNUTHILL TOWNSHIP PARK
ADA RESTROOM RENOVATION
CHESTNUTHILL TOWNSHIP,
MONROE COUNTY, PENNSYLVANIA
APRIL 1, 2026
REILLY ASSOCIATES
CHESTNUTHILL TOWNSHIP
AutoCAD SHX Text
N/F CHESTNUTHILL TOWNSHIP 1802 PG 120 PARCEL NO. 02.3.1.56
AutoCAD SHX Text
%%UUSGS MAP
AutoCAD SHX Text
SCALE: 1" = 2,000'
AutoCAD SHX Text
%%ULOCATION MAP
AutoCAD SHX Text
SCALE: 1" = 500'
AutoCAD SHX Text 1,000
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENGINEER:
AutoCAD SHX Text
49 SOUTH MAIN STREET, STE 200
AutoCAD SHX Text
ENGINEERING / ENVIRONMENTAL / SURVEYING
AutoCAD SHX Text
FAX (570) 654-6880
AutoCAD SHX Text
PITTSTON, PA. 18640
AutoCAD SHX Text
TELEPHONE (570) 654-2473
AutoCAD SHX Text
411 MAIN STREET, STE 102D
AutoCAD SHX Text
FAX (570) 421-7230
AutoCAD SHX Text
STROUDSBURG, PA. 18360
AutoCAD SHX Text
TELEPHONE (570) 421-7320
AutoCAD SHX Text
%%UPITTSTON OFFICE
AutoCAD SHX Text
%%USTROUDSBURG OFFICE
AutoCAD SHX Text %%uINDEX OF DRAWINGS
AutoCAD SHX Text
COVER SHEET AND INDEX
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
LAST REVISED
AutoCAD SHX Text
SITE PLAN / NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. THE PURPOSE OF THIS PLAN IS THE RENOVATION OF 2 EXISTING THE PURPOSE OF THIS PLAN IS THE RENOVATION OF 2 EXISTING RESTROOMS INTO 2 ADA RESTROOMS AND ASSOCIATED IMPROVEMENTS. THIS PROJECT WILL RELOCATE THE WOMEN'S RESTROOM TO THE EXISTING MEN'S RESTROOM AND VICE VERSA. 2. THE PROJECT IS LOCATED AT 221 ROUTE 715, BRODHEADSVILLE, THE PROJECT IS LOCATED AT 221 ROUTE 715, BRODHEADSVILLE, PA 18322. 3. CONTRACTOR SHALL FURNISH ALL MATERIALS, EQUIPMENT AND CONTRACTOR SHALL FURNISH ALL MATERIALS, EQUIPMENT AND LABOR TO CONSTRUCT THE PROJECT AS SHOWN HEREON AS DESCRIBED IN THE CONTRACT DOCUMENTS. 4. AS APPLICABLE, ALL CONSTRUCTION MUST COMPLY WITH THE AS APPLICABLE, ALL CONSTRUCTION MUST COMPLY WITH THE ARCHITECTURAL BARRIERS ACT OF 1968, AND SECTION 504 OF THE REHABILITATION ACT OF 1973; PA ACT 235 OF 1965, AS AMENDED, UNIVERSAL ACCESSIBILITY ACT AND AMERICANS WITH DISABILITY ACT (ADA) OF 1990, AS AMENDED. 5. ALL SIDEWALKS AND RAMPS SHALL BE CONSTRUCTED IN ALL SIDEWALKS AND RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CURRENT ADA REQUIREMENTS. (NO SIDEWALKS OR RAMPS ARE PROPOSED WITH THIS PROJECT.) 6. THE MAXIMUM CROSS SLOPE FOR ALL SIDEWALK AREAS SHALL BE THE MAXIMUM CROSS SLOPE FOR ALL SIDEWALK AREAS SHALL BE 2% AND THE MAXIMUM LONGITUDINAL SLOPE SHALL BE 5% AS MEASURED WITH A 2' LEVEL. TURN AREAS, SUCH AS INTERSECTIONS OF SIDEWALKS, SHALL NOT EXCEED A SLOPE OF 2% IN ANY DIRECTION. (NO SIDEWALKS OR RAMPS ARE (NO SIDEWALKS OR RAMPS ARE PROPOSED WITH THIS PROJECT.) 7. MAXIMUM SLOPE IN ANY DIRECTION AT HANDICAP PARKING AND MAXIMUM SLOPE IN ANY DIRECTION AT HANDICAP PARKING AND AISLES SHALL NOT EXCEED 2%. (NO PARKING LOTS OR PARKING (NO PARKING LOTS OR PARKING (NO PARKING LOTS OR PARKING MODIFICATIONS ARE PROPOSED WITH THIS PROJECT,) 8. ALL CONSTRUCTION MUST COMPLY WITH THE FEDERAL ALL CONSTRUCTION MUST COMPLY WITH THE FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA). 9. A PERMANENT PROJECT SIGN SHALL BE PROVIDED MEETING PA A PERMANENT PROJECT SIGN SHALL BE PROVIDED MEETING PA DCNR SIGN REQUIREMENTS. 10. NO ITEMS IN THIS PROJECT SHALL BE CONSIDERED PROPRIETY. NO ITEMS IN THIS PROJECT SHALL BE CONSIDERED PROPRIETY. ANY ITEM PRESENTED THAT MEETS REFERENCED PRODUCTS SPECIFICATIONS SHALL BE CONSIDERED EQUIVALENT. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXAMINING THE THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXAMINING THE AREAS AND CONDITIONS UNDER WHICH THE PROJECT IS TO BE CONSTRUCTED PRIOR TO THE SUBMISSION OF A BID. SUBMISSION OF A BID SHALL BE CONSTRUED TO MEAN THE CONTRACTOR HAS REVIEWED THE SITE AND IS FAMILIAR WITH CONDITIONS AND CONSTRAINTS OF THE SITE. 12. CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY PERMITS CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY PERMITS AS REQUIRED BY THE TOWNSHIP. THE TOWNSHIP WILL WAIVE THE PERMIT FEES. 13. DCNR PROJECT NUMBER BRC-PRD-30-59 DCNR PROJECT NUMBER BRC-PRD-30-59
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
PO BOX 243, 271 ROUTE 715 BRODHEADSVILLE, PA 18322
AutoCAD SHX Text
PORTION OF BRODHEADSVILLE, PA USGS QUADRANGLE
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
PLAN / NOTES
tel: 570.421.7320 fax: 570.421.7230 www.reillyengineering.com
411 Main Street Suite 102 D, Stroudsburg, PA 18360
AutoCAD SHX Text 48"
AutoCAD SHX Text 30"
AutoCAD SHX Text
ADA STALL
AutoCAD SHX Text 36"
AutoCAD SHX Text 30"
AutoCAD SHX Text
ADA STALL
AutoCAD SHX Text 36"
AutoCAD SHX Text 48"
AutoCAD SHX Text 30"
AutoCAD SHX Text 48"
AutoCAD SHX Text 30"
AutoCAD SHX Text
60" ADA TURNING SPACE
AutoCAD SHX Text
HAND DRIER
AutoCAD SHX Text
HAND DRIER
AutoCAD SHX Text
NOTE C.
AutoCAD SHX Text
FOLDING BABY CHANGING STATION
AutoCAD SHX Text
FOLDING BABY CHANGING STATION
AutoCAD SHX Text
60" ADA TURNING SPACE
AutoCAD SHX Text
NOTE A.
AutoCAD SHX Text
NOTE B.
AutoCAD SHX Text
NOTE D.
AutoCAD SHX Text 36"
AutoCAD SHX Text 36"
AutoCAD SHX Text
KEY SIDE
AutoCAD SHX Text 36"
AutoCAD SHX Text
NOTE O.
AutoCAD SHX Text
KEY SIDE
AutoCAD SHX Text 36"
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text Date:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Project No.
AutoCAD SHX Text
PENNSYLVANIA
AutoCAD SHX Text
CHESTNUTHILL TWP, MONROE COUNTY
AutoCAD SHX Text
ADA RESTROOM RENOVATIONS
AutoCAD SHX Text
CHESTNUTHILL TWP PARK
AutoCAD SHX Text Sheet No.
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text 4/1/2026
AutoCAD SHX Text 08003.16
AutoCAD SHX Text
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
RESTROOM RENOVATIONS
AutoCAD SHX Text PLUMBING/RESTROOM SCHEDULE BATHROOM PARTITIONS: POWDER COATED STEEL BATHROOM PARTITIONS, OVERHEAD BRACED, FLOOR MOUNTED, STAINLESS STEEL HARDWARE, COLOR TO BE : POWDER COATED STEEL BATHROOM PARTITIONS, OVERHEAD BRACED, FLOOR MOUNTED, STAINLESS STEEL HARDWARE, COLOR TO BE SELECTED BY OWNER. TO INCLUDE STAINLESS STEAL GRAB BARS AND STAINLESS STEAL TOILET PAPER DISPENSERS. LAVATORY: AMERICAN STANDARD - LUCERNE WALL-HUNG LAVATORY WITH CONCEALED ARM SUPPORT, 4” CENTERS FOR FAUCET HOLES. PROVIDE AN AMERICAN STANDARD - LUCERNE WALL-HUNG LAVATORY WITH CONCEALED ARM SUPPORT, 4” CENTERS FOR FAUCET HOLES. PROVIDE AN CENTERS FOR FAUCET HOLES. PROVIDE AN ADA COMPLIANT SHROUD AROUND THE LAVATORY PIPING USING 16 GA STAINLESS STEEL OR A PREFORMED FRP SHROUD. MOUNT USING CONCEALED FASTENERS. FAUCET: AMERICAN STANDARD - INNSBROOK SELECTRONIC FAUCET, 0.35 GPM WITH BATTERY POWER, A THERMOSTATIC MIXING CONTROL BOX, GRID AMERICAN STANDARD - INNSBROOK SELECTRONIC FAUCET, 0.35 GPM WITH BATTERY POWER, A THERMOSTATIC MIXING CONTROL BOX, GRID STRAINER DRAIN. PROVIDE TWO REPLACEMENT BATTERIES. URINAL: AMERICAN STANDARD - WASHBROOK FLOWISE UNIVERSAL URINAL : AMERICAN STANDARD - WASHBROOK FLOWISE UNIVERSAL URINAL FLUSH VALVE: AMERICAN STANDARD - ULTIMA SELECTRONIC TOUCHLESS URINAL FLUSH VALVE, PISTON-TYPE, BASE MODEL, BATTERY POWERED, 0.5 GPF. : AMERICAN STANDARD - ULTIMA SELECTRONIC TOUCHLESS URINAL FLUSH VALVE, PISTON-TYPE, BASE MODEL, BATTERY POWERED, 0.5 GPF. PROVIDE ONE REPLACEMENT BATTERY. TOILET: AMERICAN STANDARD - CADET CHAIR HEIGHT ELONGATED PRESSURE-ASSISTED TOILET 1.6 GPF : AMERICAN STANDARD - CADET CHAIR HEIGHT ELONGATED PRESSURE-ASSISTED TOILET 1.6 GPF MIRROR: ASI 0535-2436 24" WIDE X 36" TILTED ADA MIRROR. PROVIDE ONE FOR EACH RESTROOM. : ASI 0535-2436 24" WIDE X 36" TILTED ADA MIRROR. PROVIDE ONE FOR EACH RESTROOM. MIRROR LIGHTS: REPLACE ALL 4 VERTICALLY MOUNTED MIRROR SIDE LIGHTS WITH PROGRESS LIGHTING BARRIL LED 32" BATH BAR LIGHTS. : REPLACE ALL 4 VERTICALLY MOUNTED MIRROR SIDE LIGHTS WITH PROGRESS LIGHTING BARRIL LED 32" BATH BAR LIGHTS. REPLACE ALL 4 VERTICALLY MOUNTED MIRROR SIDE LIGHTS WITH PROGRESS LIGHTING BARRIL LED 32" BATH BAR LIGHTS. CEILING LIGHTS: REPLACE THE ONE SURFACE MOUNTED CEIILNG FIXTURE IN EACH RESTROOM WTH LITHONIA FML4W 48 AL06 8SWWSTD LOW PROFILE : REPLACE THE ONE SURFACE MOUNTED CEIILNG FIXTURE IN EACH RESTROOM WTH LITHONIA FML4W 48 AL06 8SWWSTD LOW PROFILE WRAPAROUND FIXTURE, WITH SELECTABLE LIGHT LUMENS AND COLOR. SET FOR 6000 LUMENS AND 3000K. BATHROOM FANS: REPLACE EXISTING EXHAUST FANS WITH SIMILAR FANS. : REPLACE EXISTING EXHAUST FANS WITH SIMILAR FANS. HAND DRIERS: SIMILAR TO XLERATOR XL-SB. 11.75"(W) x 12.69"(H) x 6.69"(D) : SIMILAR TO XLERATOR XL-SB. 11.75"(W) x 12.69"(H) x 6.69"(D) SIMILAR TO XLERATOR XL-SB. 11.75"(W) x 12.69"(H) x 6.69"(D) FOLDING BABY CHANGING STATION: KOALA KARE KB300-00,36"(L) x 21"(H) x 4"(W) : KOALA KARE KB300-00,36"(L) x 21"(H) x 4"(W) PLUMBING WALL: COVER WITH FRP PANELS, COLOR AND TEXTURE TO BE SELECTED BY OWNER. INSTALL PVC TRIM BETWEEN PANELS AND AT INTERSECTIONS COVER WITH FRP PANELS, COLOR AND TEXTURE TO BE SELECTED BY OWNER. INSTALL PVC TRIM BETWEEN PANELS AND AT INTERSECTIONS WITH OTHER WALLS AND CEILING. REPLACE EXISTING ACCESS PANELS WITH SIMILAR ITEM. ALL OTHER WALLS: REPAINT EXISTING MASONRY WALLS WITH 2 COATS OF SHERWIN WILLIAMS PRO INDUSTRIAL MULTI-SURFACE ACRYLIC IN SEMIGLOSS. : REPAINT EXISTING MASONRY WALLS WITH 2 COATS OF SHERWIN WILLIAMS PRO INDUSTRIAL MULTI-SURFACE ACRYLIC IN SEMIGLOSS. CEILING: REPAINT DRYWALL WITH 2 COATS OF SHERWIN WILLIAMS SUPERPAINT IN SEMIGLOSS. : REPAINT DRYWALL WITH 2 COATS OF SHERWIN WILLIAMS SUPERPAINT IN SEMIGLOSS. FLOORING: EXISTING FLOORING TO BE REMOVED AND REPLACED WITH TEXTURED SLIP RESISTANT EPOXY PAINT WITH DECORATIVE FLAKES, SHERWIN WILLIAMS : EXISTING FLOORING TO BE REMOVED AND REPLACED WITH TEXTURED SLIP RESISTANT EPOXY PAINT WITH DECORATIVE FLAKES, SHERWIN WILLIAMS RESUFLOR AQUA 3460. EPOXY FLOORING SHOULD BE INSTALLED AS PER MANUFACTURE'S APPLICATION INSTRUCTIONS. COVE BASE: INSTALL 4" VINYL COVE BASE ON ALL WALLS. COLOR TO BE SELECTED BY OWNER.: INSTALL 4" VINYL COVE BASE ON ALL WALLS. COLOR TO BE SELECTED BY OWNER.
AutoCAD SHX Text NOTES: A. EXISTING CLOSET FLANGE TO BE CAPPED. EXISTING CLOSET FLANGE TO BE CAPPED. B. EXISTING CLOSET FLANGE TO BE RELOCATED. EXISTING CLOSET FLANGE TO BE RELOCATED. C. EXISTING URINAL DRAIN TO BE CAPPED. EXISTING URINAL DRAIN TO BE CAPPED. D. HAND LAVS ARE TO BE RELOCATED APPROXIMATELY 7" FROM THE EXISTING LOCATION. HAND LAVS ARE TO BE RELOCATED APPROXIMATELY 7" FROM THE EXISTING LOCATION. E. WATER CLOSETS ARE TO BE ADA COMPLIANT, FLOOR MOUNTED TANK TYPE WITH POWER FLUSH. SEAT HEIGHT SHALL BE 17" - 19" ABOVE THE FLOOR. WATER CLOSETS ARE TO BE ADA COMPLIANT, FLOOR MOUNTED TANK TYPE WITH POWER FLUSH. SEAT HEIGHT SHALL BE 17" - 19" ABOVE THE FLOOR. F. LAVATORY MOUNTING HEIGHT SHALL BE 34" MAX TO RIM. LAVATORY MOUNTING HEIGHT SHALL BE 34" MAX TO RIM. G. ALL WORK SHALL COMPLY WITH THE PA UCC, IBC 2018 AND ICC A117.1-2017. ALL WORK SHALL COMPLY WITH THE PA UCC, IBC 2018 AND ICC A117.1-2017. H. ALL ROUGH PIPING SHALL BE INSTALLED IN A CONCEALED MANNER USING SIMILAR MATERIALS. ALL PLUMBING TO BE CAPPED 1.5" BELOW THE EXISTING ALL ROUGH PIPING SHALL BE INSTALLED IN A CONCEALED MANNER USING SIMILAR MATERIALS. ALL PLUMBING TO BE CAPPED 1.5" BELOW THE EXISTING SURFACE. I. ALL PATCHING OF EXISTING SUBSTRATE SHALL USE SIMILAR MATERIALS, SHALL BE FLUSH AND SMOOTH TO THE EXISTING SURFACE AND SHALL BE ALL PATCHING OF EXISTING SUBSTRATE SHALL USE SIMILAR MATERIALS, SHALL BE FLUSH AND SMOOTH TO THE EXISTING SURFACE AND SHALL BE FINISHED TO THE EXISTING TEXTURE. J. WALLS AND CEILINGS SHOULD BE REPAIRED TO ORIGINAL CONDITION OR BETTER. WALLS AND CEILINGS SHOULD BE REPAIRED TO ORIGINAL CONDITION OR BETTER. K. REPLACE ACCESS PANEL IN PLUMBING WALL. REPLACE ACCESS PANEL IN PLUMBING WALL. L. REPAIR ALL HOLES AND ANY DAMAGE IN PLUMBING WALL. REPAIR ALL HOLES AND ANY DAMAGE IN PLUMBING WALL. M. MIRRORS AND LIGHTING TO BE REPLACED WITH ASI 0535-2436 24" WIDE X 36" TILTED ADA MIRROR. MIRRORS AND LIGHTING TO BE REPLACED WITH ASI 0535-2436 24" WIDE X 36" TILTED ADA MIRROR. N. ENSURE EXISTING HOT WATER HEATERS ARE LOCATED/RELOCATED UNDER HAND LAVS. ENSURE EXISTING HOT WATER HEATERS ARE LOCATED/RELOCATED UNDER HAND LAVS. O. INTERIOR AND EXTERIOR DOORS ARE TO BE REPLACED INCLUDING ALL ASSOCIATED FRAMES AND HARDWARE. CONTRACTOR MAY NEED TO MODIFY AND/OR INTERIOR AND EXTERIOR DOORS ARE TO BE REPLACED INCLUDING ALL ASSOCIATED FRAMES AND HARDWARE. CONTRACTOR MAY NEED TO MODIFY AND/OR PAINT/REPAINT EXISTING TRIM OR OTHER ELEMENTS TO ACCOMMODATE THE NEW FRAMES. ALL MODIFICATIONS SHALL BE AGREED TO BY OWNER PRIOR TO PERFORMING THAT PORTION OF THE WORK. CONTRACTOR IS RESPONSIBLE TO COORDINATE RESETTING THE MAGNETIC LOCK AND ELECTRIFIED STRIKE. P. CONTRACTOR SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING ALL EQUIPMENT AND FURNISHINGS. CONTRACTOR SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING ALL EQUIPMENT AND FURNISHINGS. Q. CONTRACTOR SHOULD BE RESPONSIBLE FOR PROTECTING WORK AREA FROM GENERAL PUBLIC THROUGHOUT ENTIRE DURATION OF CONSTRUCTION. CONTRACTOR SHOULD BE RESPONSIBLE FOR PROTECTING WORK AREA FROM GENERAL PUBLIC THROUGHOUT ENTIRE DURATION OF CONSTRUCTION. R. BATHROOM SIGNS SHALL BE RELOCATED TO INDICATE THE CORRECT ROOM.BATHROOM SIGNS SHALL BE RELOCATED TO INDICATE THE CORRECT ROOM.
AutoCAD SHX Text DOORS: : DOOR FRAMES: PROVIDE 16 GAUGE GALVALUME FRAMES PREPARED/REINFORCED TO RECEIVE THE HARDWARE SPECIFIED. ALL ARE LOCATED IN MASONRY WALLS. INSTALL FRAMES THAT WRAP AROUND THE WALL UNLESS OTHERWISE AGREED TO BY OWNER. PROVIDE 18 GAUGE GALVALUME 6 PANEL DOORS, FOAM INSULATED AND PREPARED/REINFORCED FOR THE HARDWARE SPECIFIED. PRIME DOORS AND FRAMES WITH SHERWIN WILLIAMS S-W PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER B66-1300 SERIES AND TOPCOAT WITH PRO INDUSTRIAL DTM ACRYLIC COATING. . HARDWARE SELECTION FOR EXTERIOR DOORS: LOCKSET: FALCON T581 DANE EXTRA HEAVY DUTY LEVER LOCKSET WITH STOREROOM FUNCTION. STRIKE SHALL BE ELECTRIFIED TO RELEASE WITH THE CURRENT SECURITY SYSTEM SIMILAR TO HES 1500C. CLOSER: NORTON 7500 WITH ADJUSTABLE POWER, SPEED AND BACK CHECK, MOUNTED WITH ARM PARALLEL. HINGES: HAGAR 4.5" X 4.5" NRP BB HINGES, 3 PER LEAF. WEATHER STRIPPING: PEMKO 290 NB SWEEP: PEMKO 29326 NB THRESHOLD: PEMKO 171. A HEAVY-DUTY 1/2" HIGH X 5" WIDE TEXTURE ALUMINUM THAT IS ADA COMPLIANT. SILENCERS: ROCKWOOD 608-RKW HARDWARE SELECTION FOR INTERIOR DOORS: LOCKSET: FALCON T581 DANE EXTRA HEAVY DUTY LEVER LOCKSET WITH STOREROOM FUNCTION. DEADBOLT: FALCON D141 WITH SINGLE KEY CYLINDER. CLOSER: NORTON 7500 WITH ADJUSTABLE POWER, SPEED AND BACK CHECK, MOUNTED WITH ARM PARALLEL. NORTON 7500 WITH ADJUSTABLE POWER, SPEED AND BACK CHECK, MOUNTED WITH ARM PARALLEL. HINGES: HAGAR 4.5" X 4.5" NRP BB HINGES, 3 PER LEAF. HAGAR 4.5" X 4.5" NRP BB HINGES, 3 PER LEAF. SILENCERS: ROCKWOOD 608-RKW ALL HARDWARE: : ALL HARDWARE SHALL BE PROVIDED IN ANY AVAILABLE FINISH TO BE SELECTED BY OWNER. KEY CYLINDER SHALL MATCH EXISTING KEY AND BE KEYED TO EXISTING KEY. A PREAPPROVED "OR EQUAL" WILL BE ALLOWED.
MANUFACTURE SPECIFIED PRODUCTS NOTE: MANUFACTURE SPECIFIED PRODUCTS ARE INTENDED TO INDICATE THE TYPE AND QUALITY OF THE STATED ITEM. A PRE-APPROVED ALTERNATE WILL BE ACCEPTABLE. COLORS AND FINISHES: OWNER SHALL SELECT COLORS AND FINISHES OF ALL MATERIALS FROM ALL AVAILABLE PALETTES WITHOUT ADDITION COST TO OWNER.
9 min
6 min partition
36 min
6" max
42 min m in
7-9 180-230 m ax
LC
12 max
42 min
54 min
39 - 41 m in
(b)
60 min m in
17 max
13½ min
4 max m in
11 min m in
8 min
9 min
(a) elevation
(b) plan m in
25 max
DETAILS
tel: 570.421.7320 fax: 570.421.7230 www.reillyengineering.com
411 Main Street Suite 102 D, Stroudsburg, PA 18360
CHESTNUTHILL TOWNSHIP
PARK RESTROOMS
AutoCAD SHX Text Date:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Project No.
AutoCAD SHX Text
PENNSYLVANIA
AutoCAD SHX Text
CHESTNUTHILL TWP, MONROE COUNTY
AutoCAD SHX Text
ADA RESTROOM RENOVATIONS
AutoCAD SHX Text
CHESTNUTHILL TWP PARK
AutoCAD SHX Text Sheet No.
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text 4/1/2026
AutoCAD SHX Text 08003.16
AutoCAD SHX Text
AutoCAD SHX Text
ADA LAV ELEVATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
ADA HAND DRYER ELEVATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
BABY CHANAGING STATION ELEVATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text 12"
AutoCAD SHX Text 18"
AutoCAD SHX Text PERMANENT SIGN PANTONE COLORS: PMS 287 DARK BLUE PMS 356 DARK GREEN PMS 292 LIGHT BLUE PMS 376 LIGHT GREEN
AutoCAD SHX Text OVERALL SIZE: 12" X 18" FONT SIZE: RANGE FROM .71" TO 1.75" FONT STYLE: AERIAL ORIENTATION: LANDSCAPE BASE MATERIAL: ALUMINUM THICKNESS: .080 SIDES PRINTED: 1 CORNERS: ROUND BASE COLOR: GREEN TEXT COLOR: WHITE BORDER: YES MOUNTING:AT FUNDED PROJECT - ON WALL AT RESTROOM ENTRANCE MOUNTING HOLES: NO OVERLAY: EG VINYL LANGUAGE:STANDARD LANGUAGE FOR SIGN PROVIDED.
AutoCAD SHX Text
NOTE: 1. PERMANENT PROJECT SIGN MUST COMPLY WITH CURRENT DCNR SIGN POLICY.
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
%%UPROPOSED DCNR PERMANENT PROJECT SIGN
AutoCAD SHX Text Funding assistance has been provided by Department of Conservation and Natural Resources Bureau of Recreation and Conservation Keystone Recreation, Park and Conservation Fund and in part by a grant from the Commonwealth of Pennsylvania, Commonwealth Financing Authority
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
ADA STALL GRAB BARS
AutoCAD SHX Text
ADA STALL LAYOUT
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
TOILET PAPER DISPENSER LOCATION ZONE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
ADA STALL TOE CLEARANCE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
URINAL HEIGHT
AutoCAD SHX Text
* PARTITION SUPPORTS ARE ALLOWED IN THIS AREA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 15" min, AutoCAD SHX Text
NO SCALE
KNEE CLEARANCE
| Sheets and Views |
| 01 CV-CHP RESTROOMS |
| 02 SITE PLAN-NOTES |
| 03 DETAILS |