1_MARKET SURVEY QUESTIONNAIRE_final.pdf
PDF 206 KB Posted
- Attached to
- Natural Gas (City Gas) at Yokota Air Base, Japan
- Solicitation number
- FA520924GASYOKOTA
About this file
This document is a Market Survey Questionnaire for a federal contract opportunity to provide natural gas (City Gas) 24/7 to five supply points at Yokota Air Base in Japan. The key details are:
The projected hourly maximum flow and average annual consumption are provided for each of the five supply points, along with the supply pressure, type of gas, and heat content requirements. The contract period is from April 1, 2025 to March 31, 2030. The questionnaire asks about the vendor's ability to meet standards for yearly load factor, gas resource cost adjustment, excess hourly maximum flow volume charges, minimum orders, compensation fees, and payment terms. It also inquires about inspection, repair, and maintenance requirements under Japanese law, the possibility of multiple suppliers, and compliance with Section 804 of the NDAA. Vendors are asked about the mobilization period and to provide comments on the pricing exhibit. This is a sources sought notice and market research only; it is not a request for proposal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2_atch Draft Exhibit A.pdf | ||
| 3_Statement of Work-draft.pdf | ||
| 2_atch Draft Exhibit A.pdf | ||
| 5_atch 2 - Estimated Consumption 2024.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MARKET SURVEY QUESTIONNAIRE
For Natural Gas at Yokota Air Base
横田基地における都市ガス供給に関する市場調査
This Market Survey is to define the Japanese commercial practice whether it meets U.S. Government Natural Gas requirements. This information will not be used with other contractors or organizations, outside of the U.S.
Government. We greatly appreciate your input.
本市場調査は、在日米軍基地向け都市ガスの供給入札にあたり、日本における商習慣が米軍の要求内容
にどこまで沿うものなのかを見るものです。頂きましたご回答は、米国政府以外他の業者及び団体には
公表・使用されることは一切ございませんので、何卒ご協力の程宜しくお願い申し上げます。
Requirement: The Contractor shall provide all personnel, equipment, tools, materials, supervision and other items and services necessary to provide natural gas, twenty-four (24) hours a day, seven (7) days a week, to five (5) supply points at Yokota Air Base (YAB), indicated on Attachment 1, Supply and Gas Line Connection Points. As YAB is, expending natural gas services to residential, The Contractor shall provide the same service as stated above for residential gas service. The Contractor shall coordinate with General Gas Pipeline Provider (Buyo Gas Co., Ltd.)
and conduct periodic and emergency inspections, on Government-owned gas lines from five (5) supply points listed above to five (5) connection points in accordance with Japanese Gas Business Act (Act No. 51 of March 31, 1954) and all other relevant laws.
要求内容概要:契約業者は、添付書類 1“供給とガス管の接続箇所”に示されている、横田基地の 5 か所
の供給地点に継続的な都市ガスの供給をする。横田基地では住宅へもガス供給を行っており、契約業者
は上記同様に住宅ガス供給を行う。契約業者は、日本のガス事業法に沿って、一般ガス導管事業者(武
陽ガス)と調整し、前述 5 ヶ所の供給地点から 5 ヶ所の接続地点まで米軍所有のガス管の定期的及び緊
急時点検、保守、修理を行う。
Contract Period: 1 Apr 2025 – 31 Mar 2030 契約期間:2025 年 4 月 1 日より 2030 年 3 月 31 日
Supply Point 1:
Projected Hourly Maximum Flow: 1,504 m3/h Projected Average Annual Consumption: 2,303,150m3/yr Supply Pressure at the plant: 0.1 – 1.0 MPa at normal supply temperature of 30 deg C or below Type of gas, Quality of gas/heat content: City Gas 13A, Standard Heat Quality 45 MJ, 10,750 Kcal/m3 (HHV)
供給地点 1: 予定最大時間流量:1,504 m3/h 年間平均予定使用量: 2,303,150m3 プラントにおける供給圧力: 0.1 – 1.0 MPa(通常温度時摂氏 30 度以下) 種類及び熱量: 都市ガス 13A, 標準熱量 45 MJ, 10,750 Kcal/m3 (HHV)
Supply Point 2:
Projected Hourly Maximum Flow: 2,780 m3/h Projected Average Annual Consumption: 5,085,060m3/yr Supply Pressure at the plant: 0.1 – 1.0 MPa at normal supply temperature of 30 deg C or below Type of gas, Quality of gas/heat content: City Gas 13A, Standard Heat Quality 45 MJ, 10,750 Kcal/m3 (HHV)
供給地点 2: 予定最大時間流量:: 2,780 m3/h 年間平均予定使用量: : 5,085,060m3 プラントにおける供給圧力: 0.1 – 1.0 MPa(摂氏 30 度以下通常供給温度時) 種類及び熱量: 都市ガス 13A, 標準熱量 45 MJ, 10,750 Kcal/m3 (HHV)
Supply Point 3:
Projected Hourly Maximum Flow: 7,065m3/h Projected Average Annual Consumption: 20,069,459m3/yr Supply Pressure at the plant: 0.1 – 1.0 MPa at normal supply temperature of 30 deg C or below Type of gas, Quality of gas/heat content: City Gas 13A, Standard Heat Quality 45 MJ, 10,750 Kcal/m3 (HHV)
供給地点 3: 予定最大時間流量:7,065m3/h
年間平均予定使用量: : 20,069,459m3 プラントにおける供給圧力: 0.1 – 1.0 MPa(摂氏 30 度以下通常供給温度時) 種類及び熱量: 都市ガス 13A, 標準熱量 45 MJ, 10,750 Kcal/m3 (HHV)
Supply Point 4:
Projected Hourly Maximum Flow: 127m3/h Projected Average Annual Consumption: 52,838 m3/yr Supply Pressure at the plant: 1.0 – 2.5 KPa and 1KPa – 0.1MPa at normal supply temperature of 30 deg C or below Type of gas, Quality of gas/heat content: City Gas 13A, Standard Heat Quality 45 MJ, 10,750 Kcal/m3 (HHV)
供給地点 4: 予定最大時間流量:127m3/h 年間平均予定使用量: : 52,838 m3/yr プラントにおける供給圧力: : 1.0 – 2.5 KPa 及び 1KPa – 0.1MPa (摂氏 30 度以下通常供給温度時) 種類及び熱量: 都市ガス 13A, 標準熱量 45 MJ, 10,750 Kcal/m3 (HHV)
Supply Point 5:
Projected Hourly Maximum Flow: 131m3/h Projected Average Annual Consumption: 162,000m3/yr Supply Pressure at the plant: 500 – 700 KPa and 1KPa – 0.1MPa at normal supply temperature of 30 deg C or below Type of gas, Quality of gas/heat content: City Gas 13A, Standard Heat Quality 45 MJ, 10,750 Kcal/m3 (HHV)
供給地点 5: 予定最大時間流量:131m3/h 年間平均予定使用量: : 162,000m3 プラントにおける供給圧力: 500 – 700 KPa and 1KPa – 0.1MPa(摂氏 30 度以下通常供給温度時) 種類及び熱量: 都市ガス 13A, 標準熱量 45 MJ, 10,750 Kcal/m3 (HHV)
Area of Performance: Yokota Air Base 供給地点:横田基地
Questions 質問 YES NO Q1. In the draft Statement of Work, the following standards and numbers are based on the conditions of a local General Gas Business (Buyo Gas Co., Ltd is the General Gas Business in this requirement) such as general gas supply conditions and/or optional supply condition. Are you able to offer with the following conditions?
米軍の仕様書(草案)では、下記の項目の基準や数値を当該地域の一般ガス事業者(横田基地においては
武陽ガス)の「一般ガス供給約款」及び「選択約款」等を基に作成をしているが、下記のそれぞれの項目
において入札条件とすることは可能か?
a. [Yearly Load Factor] Standard Yearly Load Factor: 55%
[年間負荷率] 年間負荷率の基準: 55% 可能である 可能でない
If no, what is your standard?
可能でない場合は貴社の基準を教えてください。
b. [Gas Resource Cost Adjustment] Calculation formula and each associated cost (Average Gas Resource Cost, Gas Resource Base, Gas Resource Adjustment Unit Price, etc..) Reference URL: http://www.buyo-gas.co.jp/guidance/rate/rate2-1.html [原料費調整] 原料費調整額の算出方法、及び各価格(平均原料価格、
基準平均原料価格、調整単位料金等)参考URL:http://www.buyo-gas.co.jp/guidance/rate/rate2-1.html
可能である 可能でない
If no, what is your standard? (It is possible if the Government assigns Gas Resource Base, etc.) 可能でな
い場合は貴社の基準を教えてください。(米軍で指定の基準原料価格なら可能等)
c. Excess of Hourly Max Flow Volume Charge: Do you charge a fee for exceeding the contracted Hourly Max Flow Volume?
[最大流量超過補償料] 契約最大流量超過料は課しているか
行っている 行っていない
If yes, what is your standard/conditions?
行っている場合、貴社の基準・条件を教えてください。
Q2. Minimum Order: Do you charge a settlement amount for not ordering the yearly minimum order amount?
引取量: 年間引取量未達精算額を課しているか?
行っている 行っていない
If yes, what is the minimum order amount as a percentage of the yearly contracted usage?
行っている場合、年間引取量は契約年間使用量の何パーセントか教えてください。
Q3. Is there a compensation fee if the contract year usage is exceeded? 契約年数使用
量を超えた場合、補償料はあるのか?
ある ない
行っている場合、貴社の基準・条件を教えてください。
Q4. Are there any clearing/compensation fees other than Q1c, Q2 and Q3?
Q1c、Q2、Q3 以外の清算・補償料はあるのか?
ある ない
ある場合、貴社の基準・条件を教えてください。
Q5. Payment Terms: Payment discount terms for the U.S. Government are “Contractor will be paid within 30 day after the Government receives a proper invoice. In case of the late payment, the payment will be made with the interest rate established by the U.S. Department of the Treasure.” Are these conditions acceptable?
支払条件:米軍では支払い条件は、 「米軍が正当な請求書を受け取ってから、30 日で支払を行う。その日を超えた後の支払いはアメリカ財務
省の設定した延滞利息に基づき、延滞利息が請求額に上乗せをされて支払われる。」この支払い条件は受
け入れ可能か?
If no, what are your payment conditions (payment due date, date rate interest is accrued, interest rate, etc..)?
可能である 可能でない
可能でない場合は貴社支払い条件(支払期日、延滞利息発生日、利率
等)
Q6. Contract Period: The Government is planning to procure a five-year contract with fixed unit prices. Are these conditions acceptable?
契約期間:米軍では今回の入札では 5 年の契約期間を予定しています。価格は最初に 5 年分の固定単価を
設定。このような契約形態、期間の入札参加は可能か? If yes with conditions, what are the conditions? (e.g. Unit price can be changed during the contract period, contract period cannot be excess for 3 years, etc.)
条件付きで可能の場合、その条件(例: 契約期間において料金単価の
更改ができる、契約期間は3年まで等)
条件付で可能
である(Yes with conditions)
If no, what is the reason and what conditions can you accept?
可能でない場合はその理由及び参加できる条件
Q7. Inspection, Repair and Maintenance: Do the Japanese gas laws stipulate the Contractor’s requirement of inspection, repair and maintenance for the customer’s gas lines? If yes, are the costs for the inspection and maintenance normally included in a gas unit price?
点検・修理・保守:日本の法規では、需要家所有のガス管に、ガス供給契約会社が、定期的、及び
緊急時点検、修理・保守を行うと規定されているか?規定されている場合、その点検や保守の費用
は通常ガス単価に含まれていると考えてよいか?
Comments コメント
規定されてる
規定されてい
ない
含まれている 含まれていな
い
Q8. The Ministry of Economy, Trade and Industry (METI) has a principle of one demand point and one contract.
Will Yokota’s requirement including 5 supply points be considered as “one demand point and one contract”? Or, is it possible for different retailers to supply gas to different supply points? (e.g. Supply Point 1 = Company A, Supply Point 2 = Company B) 経済産業省により 1 需要場所・1 契約の原則となっているが、横田基地の供給地点は 5 箇所あり、これを
1 需要場所・1 契約とみなしますか。また、供給地点によって別の小売りがガスを提供することは可能で
すか。(例:供給地点 1 = A 社、供給地点 2 = B 社)
Q9. Section 804 of the NDAA prohibits contracting officers from entering into a contract with companies that have ties to Russian government authorities or fossil fuel companies operating in Russia and are not less than 50 percent owned by them. Does your company purchase a gas from Russian Company which is more than 50 percent owned by them?
国防権限法第 804 条により、ロシア政府当局やロシアで事業展開する化石燃
料企業とつながりがあり、その所有率が 50%を下回らない企業との契約を禁
じられている。貴社は、ロシア企業が 50%以上出資する会社からガスを購入
していますか。
はい いいえ
Q10. What is an adequate mobilization period to start suppling gas upon notice of award? What kind of procedure do you need to take?
落札決定からガス供給ができるまでの必要な手続き及びその期間を教えてください。
Q11. Attached Exhibit is the form for your offer price. Please let us know if you have any comments on the form.
(e.g. an item, XYZ, should be in the exhibit, etc.)
別紙 1 は、入札額を記入する用紙になります。用紙についてご意見ありましたら、ご記入ください。
(例:OO の項目が必要である等)
Q12. Are you interested in providing offer for this requirement (see page 1&2)?
今回の要求内容(1~2 ページに記載)での、入札参加にご興味はありますか?
ある
ない
Remarks.
その他ご意見等がございましたら、ご記入下さい。
Company Name (会社名): ______________________________________________________________________________
POC Name (担当者): ______________________________________/_________________________________
Telephone (電話番号):_________________________________/_______________________________
E-mail (E メーアドレス): ________________________________________________________________________________
Date (日時): _________________________________
Thank you very much for taking time to fill out this questionnaire.
貴重なお時間を割いて頂き誠にありがとうございました。
市場調査送信先:在日米軍横田基地 第 374 契約中隊 高島宛 E メール:yuri.takashima.jp@us.af.mil
TEL: 042-553-8549
File details come from the government source that posted it. Updated .